Loading...
HomeMy WebLinkAboutNC0028916_Pretreatment Inspection_20020515ArrA NCDENR North Carolina Department of Environment and Natural Resources Michael F. Easley, Governor May 15, 2002 Roy Maness, Mayor Town of Troy 444 North Main Street Troy, North Carolina SUBJECT: Pretreatment Compliance Inspection Town of Troy WWTP NPDES Permit No. NC0028916 Montgomery County Dear Mr. Walls: William G. Ross Jr., Secretary Gregory J. Thorpe, Ph.D. Acting Director Division of Water Quality Enclosed you will find a copy of the Pretreatment Compliance Inspection Report for the inspection conducted on May 2, 2002. The report indicates that Troy WWTP continues to meet the pretreatment requirements as outlined in 15A NCAC 2H .0904 (b) for Modified Pretreatment Programs. You are commended for your continued success in maintaining your program. As a reminder, every five years the IWS and HWA need to be updated. They are due at the Pretreatment Unit in Raleigh by the month of October 2003. Enclosed with this report is the schedule frequency and sampling plan copied from the N.C. Pretreatment Comprehensive Guide for Modified Pretreatment Programs. The STMP for Modified PT programs was originally designed with 4 consecutive days of monitoring at the WWTP influent and effluent. However, the Division is now strongly recommending one influent and effluent sample each quarter for 4 quarters. The Division presents a one -day HWA training session to instruct POTW pretreatment staff and consultants in developing an HWA. The PT Unit holds them approximately once every two months, usually alternating between the eastern half and western half of the state. Please contact the PT Unit if you wish to attend an HWA workshop. The report is self-explanatory and contains observations and recommendations. If you or your staff have any questions or require clarification, please do not hesitate to contact me at (910) 486-1541. Idl Enclosures: cc: • Dale Lopez Environmental Specialist Pretreatment Compliance Inspection Report LTMP Frequency for STMP for Modified PT Programs Gray Walls, P.E., Town of Troy, Public Works Director DWQ Pretreatment Unit Fayetteville Regional Office 225 Green Street — Suite 714, Fayetteville, North Carolina 28301-5043 Phone: 910-486-1541 1 FAX: 910-486-07071 Internet: www.enr.state.nc.usi ENR An Equal Opportunity 1 Affirmative Action Employer — 50% Recycled 110% Post Consumer Paper NORTH CAROLINA DIVISION OF WATER QUALITY PRETREATMENT COMPLIANCE INSPECTION (PCI) REPORT FAYETTEVILLE REGIONAL OFFICE BACKGROUND INFORMATION 1. Control Authority (POTW) Name: Town of Troy 2. Control Authority Representative: Gray Walls, P.E./Linda Walls 3. Title(s): Public Works Director/Pretreatment Coordinator 4. Last Inspection Date: May 23, 2001 Inspection Type (Circle One): PCI Audit 5. Has Program Completed All Requirements from the Previous Inspection or Program Info Sheet(s)? 6. Is POTW under an Order That Includes Pretreatment Conditions? Order Type And Number: Are Milestone Dates Being Met?Yes / No / PCS CODING Trans.Code Program NPDES Number MM/DD/YY Inspec.Type INt J NI CIO 10 12 18 19 I1 16 05 /02 /02 Ji (DTIA) (TYPI) 7. Current Number of Significant Industrial Users (SIUs)? 8. Current Number of Categorical Industrial Users (CIUs)? 9. Number of SIUs Not Inspected by POTW in the Last Calendar Year? 10. Number of SIUs Not Sampled by POTW in the Last Calendar Year? 11. Enter the Higher Number of 9 or 10. 12. Number of SIUs With No IUP or With an Expired IUP? 13. Number of SIUs In SNC for Either Reporting or Limits Violations During Either of the Last 2 Semi -Annual Periods (Total Number of SIUs in SNC). 14. Number of SIUs in SNC for Reporting During Either of the Last 2 Semi -Annual Periods. 15. Number of SIUs in SNC for Limits Violations During Either of the Last 2 Semi -Annual Periods? 16. Number of SIUs in SNC for Both Reporting and Limits Violations During Either of the Last 2 Semi -Annual Periods? POTW INTERVIEW 17. Since the Last PCI, has the POTW had any NPDES Limits Violations? If Yes, What are the parameters and how are these problems being addressed? TSS weekly in October, and an Aquatic Toxicity failure in October. Both due to temperature inversion. Since the Last PCI, has the POTW had any Problems Related to an Industrial Discharge (Interference, Pass -Through, Blockage, Citizens' Complaints, Increased Sludge Production, 18. Etc.)? If Yes, How Are These Problems Being Addressed? NIAI Inspector Lai (INSP) [Yes / No Yes / No Fac.Type J_il (FACC) 2 0 0 0 0 0 0 0 0 0 SIUS CIUS NOIN NOCM PSNC MSNC SNPS YES NO YES NO 19. Which Industries have been in SNC during either of the Last 2 Semi - Annual Periods? Have any Industries in SNC (During Either of the Last 2 Semi -Annual Periods) not been Published for Public Notice? (May refer to PAR if Excessive SIUs in SNC) SNC for Limits: 0 SNC for Reporting: 0 Not Published: 0 20. Which Industries are on Compliance Schedules or Orders? For all SIUs on an Order, Has a Signed copy of the Order been sent to the Division? 21. Are any Permits or Civil Penalties Currently Under Adjudication? If Yes, Which Ones? None YES NO PRETREATMENT PROGRAM ELEMENTS REVIEW - Please review POTW files and complete the following: Program Element Date of Last Approval Date Next Due, If Applicable Headwork Analysis (HWA) 10/20/98 Industrial Waste Survey (IWS) 10/29/98 Sewer Use Ordinance (SUO) 06/04/97 Enforcement Response Plan (ERP) 11/24/92 Long Term Monitoring Plan (LTMP 10/20/98 22. Is the LTMP Monitoring Being Conducted at Appropriate Locations and Frequencies? IYes / No 23. Should any Pollutants of Concern be Eliminated From or Added to the LTMP? If Yes, which ones? Eliminated: Added: 24. Are Correct Detection Levels being used for all LTMP Monitoring? Yes / IYes 25. Is the LTMP Data Maintained in a Table or Equivalent? IYes / No Is the Table Adequate? INo / No Yes / No INDUSTRIAL USER PERMIT (UP) FILE REVIEW 26. User Name 1. Candor Hosiery 2. Capel 3. 27. IUP Number 0007 0002 28. Does File Contain Current Permit? a. Yes / No Yes/No 29. Permit Expiration Date? 01/01/04 01/01/04 30. Categorical Standard Applied (I.E. 40 CFR 413, Etc.) or N/A N/A N/A 31. Does the File Contain Permit Application Completed Within One Year Prior to Permit Issue Date? Yes / No N o 32. Does the File Contain an Inspection Completed Within Last Calendar Year? 'Yes / No Elo 33. a. Does File Contain A Slug Control Plan? b. If No, is One Needed? (See Inspection Form from POTW) a. Yes b. Yes / INo / No a. Yes/ To b. Yes/ To 34. For 40 CFR 413 And 433 TTO Certifiers, Does The File Contain A • Toxic Organic Management Plan (TOMP)? Yes / No IN/AI Yes/No N/AI 35. a. Does the File Contain Original Permit Review Letter from the Division? b. All Issues Resolved? E b. o Yes a. es No b.Yes / No N/A 36. During the Most Recent Semi -Annual Period, Did the POTW Complete its Sampling as Required by IUP? Yes / No M o 37. Does File Contain POTW Sampling Chain -Of -Custody's? [Yes / No M o 38. During the Most Recent Semi -Annual Period, Did the SIU Complete its Sampling as. Required By IUP? Yes / No N/AI Yes/No N/A 39. Does Sampling Indicate Flow or Production? Influent Influent Consumption Consumption Only On1 Yes oI Yes / No N/A 40. During the Most Recent Semi -Annual Period, Did the POTW Identify All Non -Compliance from Both POTW and SIU Sampling? Yes / No E o 41. a. Was the POTW Notified by SIU (Within 24 Hours) of All Self- Monitoring Violations b. Did Industry Resample Within 30 Days? a.Yes b.IYes / No/ N/A / No/ N/A OM Yes o/ N/A 42. Was the SIU Promptly Notified of any Violations (Per ERP)? No Violations NoViolations Yes/No N/A Yes / No N/A e 43. During the Most Recent Semi -Annual Period, Was the SIU in SNC? 44. During the Most Recent Semi -Annual Period, Was Enforcement Taken as Specified in the POTWs ERP? 45. Does the File Contain Penalty Assessment Notices? 46. Does the File Contain Proof of Penalty Collection? 47. a. Does the File Contain any Current Enforcement orders? b. Is SIU in Compliance with Order? 48. Did the POTW Representative Have Difficulty in Obtaining any of this Requested Information for You? FILE REVIEW COMMENTS PCI SUMMARY AND COMMENTS Yes / No Yes No Yes /No/ ,N/AJ Yes/No N/A] Yes / No N/AI Yes/No Il/A Yes / No N/A4 Yes/No INUA a.Yes / No b.Yes / No N/A Yes/No IN/A1 N/A Yes / INo Yes/To PCI Comments: Please review the enclosed (F.) Sampling STMP Frequency , and (G.) STMP Sampling Plan in preparation for the HWA due in the year 2003. This facility has a well -organized pretreatment program. Files are neat and organized. Requirements: Recommendations: NOD: YES NOV: YES QNCR: YES POTW Rating: NO NO NO Satisfactory ✓ Marginal atisfactory Date:05/15/02 PCI COMPLETED BY: Dale Lopez, Environmental Specialist ClL Uf MODIFIED PROGRAMS Activated Sludge/Aerobic Digester with Land Application STMP Model (continued) F. Sampling: Frequency Sampling Point Withinl Year Before HWA 1- Influent 4 consecutive workdays (Monday -Thursday) 2 - Effluent 4 consecutive workdays (Monday - Thursday) 3 - Activated Sludge Basin Once 4 - Sludge to Disposal. Per Sludge Permit and 503 regulations 5, 6 & 7 -. SIU's Per SIU Permit (Recommended for all POC's once) G. Sampling Plan P.O.C. Pt. 1 Pt. 2 Pt. 3 Pt.4 As .x .x x. x Cd x x x x Cr .'x x x x Cu x x x x Pb x x. x:., x.._ Hg x x x x Mb x x x x Ni: x ' x x x Se x x.. x x._ 7n x x x x Flow x x %solids x BCC x x TSS x x All POC's should be indicated on the sampling plan.. Chaps: LTMP Guidance Filename: STMP model 940607 Revision Date: August 1. 1994 Chapter 4 Appendix C Page 2