Loading...
HomeMy WebLinkAboutNC0028916_Inspection_20010627North Carolina Department of Environment and Natural Resources Division of Water Quality Fayetteville Regional Office . Michael F. Easley, Governor • William G. Ross, Jr.; Secretary Kerr T. Stevens, Director The Honorable Roy Maness Mayor, Town of Troy 444 N. Main Street Troy, NC 27371 June 27, 2001 SUBJECT: Compliance Evaluation Inspection Town of Troy Wastewater Treatment Plant NPDES Permit No. NC0028916 Montgomery County Dear Mr. Maness: Enclosed is a copy of the Compliance Evaluation Inspection conducted June 25, 2001. As part of the inspection a tour of the Wastewater Treatment Plant was conducted. All observations and recommendations are in Part D. Summary of Findings/Comments of this inspection report. The cooperation of Mr. Stephen Jarman, Operator in Responsible Charge was appreciated. The objective we should all be striving for is NPDES permit compliance which in turn will provide preservation of our receiving stream for generations to come. AtzprA wiltagysi. NCDENR Please review the attached report. If you or your staff have any questions do not hesitate to contact me at 910-486-1541. Sincerely, Belinda S. Henson Environmental Chemist /bsh Enclosures 225 GREEN STREET _ SUITE 714 / SYSTEL BUILDING / FAYETTEVILLE, NC 28301-5043 PHONE (910) 486-1541 FAX (910) 486-0707 WWW.ENR.STATE.NC.US/ENIL' AN EQUAL OPPORTUNITY / AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/10%. POST CONSUMER PAPER . DENR TOLL FREE HOTLINE: 1-877-623-6748 NPDES COMPLIANCE INSPECTION REPORT North Carolina Division of Water Quality Fayetteville Regional Office Section A. National Data System Coding Transaction Code: N NPDES NO. NC0028916 Date: 010625 Inspection Type: C Inspector: S Facility -Type: 1 Reserved: Facility Evaluation Rating: 4 BI: N QA: N Reserved: Section B: Facility Data Name and Location of Facility Inspected: Town of Troy WWTP Entry Time:.10:00am Permit Effective Date: 010101 Exit Time/Date: 2:00pm/010625 Permit Expiration Date: 040630 Naine(s), Title(s) of On -Site Representative(s): Stephen Jarman (Certified Grade III Operator) - "ORC" . Gray Walls - "Public Works Director/Town Engineer" Phone Number(s): (910) 572-1186 Name, Title and Address of Responsible Official Mr. Roy Maness, Mayor 444 N. Main Street Troy, NC 27371 Contacted: no Section C: Areas Evaluated During Inspection (S = Satisfactory, M = Marginal, U = Unsatisfactory, N = Not Evaluated, N/A =.Not Applicable) cardslRe Ora ;o] w: uen eaSiureeni ecevin ratters:; retreatre pmpuance. o nitnrin per ...00'i audefiati. eUrsposat; Maness Page 3 June 27, 2001 Section D: Summary of Findings/Comments: 1. This facility continues to be operated by the contract company "Water Technology and Controls" for the Town. The Town continues to maintain the facility and incorporate all ongoing projects of improvement. A new backup generator is oiisite and will be operational in the near future. It will operate the entire plant when it is online. A manual bar screen and a rotameter are used to remove trash and debris at the headworks of the plant. The rotameter operates by an ultrasonic sensor which senses the flow depth and automatically operates. All screenings are disposed of through the Uwharrie Environmental Landfill. The grit removal system appeared to be operational. It is turned on twice a day. All grit is disposed of in the Uwharrie Environmental Landfill. Caustic is added to the influent when pH adjustment is needed. The influent composite sampler refrigerator temperature was 3 degrees Celsius, which is adequate for proper preservation of samples. Samples should be maintained at 0 - 4 degrees Celsius. The oxidation ditches appeared to be operating efficiently. The ditches operate in series. An anoxic zone is used to reduce nitrogen and phosphorus. The facility analyzes Mixed Liquor Suspended Solids (MLSS) on a monthly basis. The most recent results are approximately 3500 mg/1, which is a good range for this facility in the summer months and 4000 mg/1 in the winter months as per Mr. Jarman. 8. The clarifiers' sludge depth was approximately two and one half (2 '/2) feet with tank depths of ten (10) feet. Improvements have been made on the clarifiers since the last inspection. New skirts have been installed around the diameter of the circular tanks. Areas on the clarifier walkway appeared to have paint worn from them. These areas should be painted in the near future to eliminate major repairs in the future. 9. Chlorine is .used in disinfection of the effluent. The chlorine contact tank appeared to have a few floatables not excessive. The floatables are skimmed away daily and properly disposed of in a container located beside the tank. The contents of the container are taken to the county landfill for final disposal. 10. The effluent appeared to be free of solids. 11. The effluent outfall could not be visually noted due to vegetative growth. This area should be cleared to maintain access to the outfall. 12. The digester appeared to bd• operating adequately. The sludge holding tank appeared to be approximately 2/3 full with supernatant being decanted at the time of the inspection in preparation for land applying . Biosolids are land applied under permit # WQ0001240 approximately every 18 months by the contract company " Synagro". Maness Page 4 June 27, 2001 13. Two lagoons are located on site. The largest lagoon is used as a equalizing lagoon for high flow periods. The smaller lagoon is no longer utilized. 14. The grounds were neat and clean. 15. The flow meters are calibrated: quarterly by staff and documented. It is advisable that the flow meter calibration document contain the % error before and after calibration in the future by the technician. 16. The effluent refrigerated composite sampler temperature was 2 degrees Celsius which is adequate for proper preservation of samples. The tubing was clean and adequately maintained. 17. The following NPDES permitrequired parameters are analyzed by facility staff: pH, Temperature, Dissolved Oxygen, and Chlorine Residual. All other required parameters are analyzed by "Water Technology and Controls". Laboratory records were reviewed for the months September and October 2000 and compared to Discharge Monitoring Reports (DMR). All records reviewed appeared to be accurate. A compliance evaluation analysis report for the period May 2000 through April 2001 did not reveal any monthly violations. The facility should be commended for their continued compliance of their NPDES permit. 20. The NPDES permit was available upon request. A new NPDES permit was issued effective January 1, 2001. 21. Maintenance and operational records were reviewed. All records reviewed were adequate. 22. The facility is progressing with a new SCADA system which will assist with daily operations and provide 24 hour surveillance. 23. The "Backup Operator" for this facility is Pat Merritt,a Grade II Wastewater Treatment Operator. Name and Signature of Inspector Agency/Office/Telephone Date Belinda Hen n -, .4 Name and Signature of Reviewer DENR/Fayetteville/(910)486-1541 C — 9:7— 01 Agency/Office/Telephone Date Grady Dobson DENR/Fayetteville/(910)486-1541 Action Taken Regulatory Office Use Only Compliance Status Noncompliance _Compliance Date Section D: Summary of Findings/Comments Brief Facility Description: A 0.84 MGD WWTP consisting of a flow equalization lagoon, mechanical bar screen. grit removal. dual oxidation ditches. dual secondary clarification, sludge digester. sludge holding tank, chlorine disinfection. FACILITY SITE REVIEW No N/A 1. " Treatment units properly operated and maintained.. Yes N/A 2. Standby power or other equivalent provision provided. Go in e(c0-(` a r1 s ` 1c � .{- o pl0 n nq1 es �No N/A 3. Adequate alarm system for power or equipment failure available. et- 4. Sludge disposal procedures appropriate: No N/A a. Disposal of sludge according to regulations No N/A b. State approval for sludge disposal received. Yes No N/A 5. All treatment units other than backup units in service. No N/A 6. Sufficient sludge disposed of to maintain treatment process equilibrium. No N/A 7. Adequate number of qualified operators on staff. No N/A 8. Established procedures available for training new employees. es�No N/A 9. Adequate spare parts and supplies inventory maintained. Yes. Nod N/A 10. a. Hydraulic overflows and/or organic overloads experienced Yes N/A b. Untreated bypass discharge occurs during power failure Yes e N/A c. Untreated overflows occurred since last inspection. ' res)No N/A 11. Plant has general safety structures such as rails around or covers over tanks, pits, or wells. No N/A 12. Plant is generally clean, free from open trash areas. s i No N/A es' No N/A Yes L�To N/A es No N/A Yes o N/A Yes o N/A es No N/A 13. Screening: a. Manual b. Mechanical c. Buildup of debris d. Screenings properly disposed of 14. Grit Removal: a. Excessive organic content in the grit chamber b. Excessive odors c. Grit properly disposed of. Page 2 15. Primary clarifier: Yes No N% a. Excessive gas bubbles Yes No N/A b. Black and odorous wastewater Yes No N/A c. Poor suspended solids removed Yes No N/A d. Excessive buildup of solids in center well of circular clarifier Yes No N/A e. Weirs level Yes No N/A f. Weir blockage Yes No N/A g. Evidence of short circuiting Yes No N/A h. Lack of adequate scum removal Yes No N/A i. Excessive floating sludge Yes No N/A j. Broken sludge scraper. 16. Trickling Filter: Yes No N/X a. Trickling filter ponding(indicating clogged media) Yes No N/A b. Leak at center column of trickling filter's distribution arms Yes No N/A c. Uneven distribution of flow on trickling filter surface Yes No N/A d. Uneven or discolored growth Yes No N/A e. Excessive sloughing of growth Yes No N/A f. Odor Yes No N/A g. Clogging of trickling filter's distribution arm orifices Yes No N/A h. Filter flies, worms, or snails. 17. Rotating Biological Contactors (RBC): Yes No N/A) a. Development of white biomass on rotating biological contactor media Yes No N/A b. Excessive sloughing of growth Yes No N/A c. Excessive breakage of rotating disks or shafts in RBC units Yes No N/A d. Excessive breakage of paddles on brush aerators Yes No N/A e. Shaft, bearing, drive gear, or motor failure on disk or brush aerators. 18. Activated Sludge Basins/Oxidation Ditches: Yes No) N/A a. Dead spots Yes N/A b. Failure of surface aerators Yes C N/A c. Air rising in clumps Yes N/A d. Dark foam or bad color Yes N/A e. Thick billows of white, sudsy foam Yes No U 0 f. Air rising unevenly Yes No g. Excessive air leaks in compressed air piping. Yes No Ni'm Yes No N/A Yes No N/A Yes No N/A Yes Yes 0 Yes Yes �a- Yes Cho Yes a:)", Yes Yes Io Yeses} Yes ea Q' Page 3 19. Stabilization Ponds/Lagoons: a. Excessive weeds including duckweed in stabilization ponds b. Dead fish or aquatic organisms c. Buildup of solids around influent pipe d. Excessive scum on surface. 20. Secondary Clarifier: N/A a. Excessive gas bubbles on surface N/A b. Unlevel overflow weirs N/A c. Weir blockage N/A d. Evidence of short circuiting N/A e. Excessive buildup of solids in center well of circular clarifier N/A f Pin floc in overflow N/A g. Ineffective scum rake N/A h. Floating sludge on surface N/A i. Excessive high sludge blanket N/A j. Clogged sludge withdrawal ports on secondary clarifier. 21. Filtration: Yes No /A? a. Filter surface clogging Yes No N/A ' b. Short filter run Yes No N/A c. Gravel displacement of filter media Yes No N/A. d. Loss of filter media during backwashing Yes No N/A e. Recycled filter backwash water in excess of 5 percent Yes No N/A f Formation of mudballs in filter media. Yes N/A Yes e N/A Yes N/A Yes No N/A Yes No N/A Yes No N/A Yes No N/A No N/A 22. Chlorination Unit: a. Sludge buildup in contact chamber b. Gas bubbles c. Floating scum and/or solids d. Adequate ventilation of chlorine feeding room and storage area e. NIOSH-approved 30 minute air pack f. All standing chlorine cylinders chained in place g. All personnel trained in the use of chlorine h. Proper chlorine feed, storage, and reserve supply. Page 4 Yes No ( ' 23. Ultraviolet radiation disinfection present and in use. 24. Dechlorination: Yes No a. Proper storage of sulfur dioxide cylinders Yes No N/A b. Adequate. ventilation of sulfur dioxide feeding room Yes No N/A c. Automatic sulfur dioxide feed or feedback control not operating properly. 25. Aerobic Digester: Yes .) N/A -a. Excessive foaming in tank Yes W N/A b. Noxious odor Yes . c. Mechanical aeration failure Yes .. N/A d. Clogging of diffusers. 26. Anaerobic Digester: Yes No a. Floating cover tilting Yes No N/A b. Gas burner operative Yes No N/A c. Supernatant has a sour odor. 27. Sludge Drying and/or disposal: Yes No a. Poor sludge distribution on drying beds Yes No N/A b. Vegetation in drying beds Yes No N/A c. Dry sludge remaining in drying beds Yes No N/A d. Dry sludge stored on site Yes No N/A e. Filtrate from sludge drying beds returned to front of plant Yes No N/A f. Approved disposal site for the sludge es) No N/A g. Sludge land applied. 28. Filter Press: Yes No a. High level of solids in filtrate from filter presses or vacuum filters Yes No N/A b. Thin filter cake caused by poor dewatering Yes No N/A c. Sludge buildup on belts and/or rollers of filter press Yes No N/A d. Excessive moisture in belt filter press sludge cake. Yes No (NjA Yes No N/A Yes No N/A 29. Polishing Ponds or Tanks: a. Objectionable odor, excessive foam, floating solids, or oil sheens on water surface b. Solids or scum accumulations in tank or at side of pond c. Evidence of bypassed polishing ponds or tanks because of low capacity. Page 5 30. Plant Effluent: Yes N/A a. Excessive suspended solids, turbidity, foam, grease, scum, color, and other macroscopic particulate matter present Yes a N/A b. Potential toxicity (dead fish, dead plant at discharge) Yes T) N/A c. Outfall discharge line easily accessible. No N/A No N/A Yes N/A Yes ITT N/A Yes No ON Yes No `:Yes a0 N/A Yes 0 N/A Yes No N/A No N/A No N/A No N/A . Yes No N/A N/A 31. Flow Measurement: a. Proper placement of flow measurement device b. Flow meter calibrated c. Buildup of solids in flume or weir d. Broken or cracked flume or weir e. Properly functioning magnetic flowmeter f. Clogged or broken stilling wells g. Weir plate edge corroded or damaged h. System capable of measuring maximum flow i Flow measurement error less than 10%. 32. Sampling: a. Sampling and analysis completed on parameters specified by permit b. Samples refrigerated during compositing c. Composite sample temperatures maintained at O. to 4 degrees Celsius during sampling d. Contract laboratory used for sample analysis e. Composite samples obtained are flow proportional. logs el euely 0 'ri'1; Jlt42SS RECORDKEEPING AND REPORTING No N/A 1. Records and reports maintained as required by permit. Yes) No N/A 2. All required information available, complete; and current. esD No N/A 3. Records maintained for 3 years and all sludge records maintained for 5 years. es No N/A 4. Analytical results consistent with data reported on DMRs. No N/A No N/A No N/A No. N/A e 'No N/A 5. Sampling and analyses data adequate and include: a. Dates, times, and location of sampling b. Name of individual performing sampling c. Results of analyses and calibration d. Dates of analyses e. Name of person performing analyses. Yes No N/A s No N/A es No N/A Page 6 6. Monitoring records adequate and include: a. Monitoring charts kept for 3 years b. Flowmeter calibration records kept for 3 years. 7. Laboratory equipment calibration and maintenance records adequate. Yes No T/A} 8. BOD incubator temperature maintained at 20 +/- 1 Degrees Celsius and the temperature maintained in a log for every day of operation. Yes No 0. 9. Fecal coliform incubator maintained at 44.5 +/- 0.2Degrees Celsius and the temperature maintained in a log for every day of operation. No N/A Y' i) No N/A No N/A Yes No Yes No Ye , No N/A es No N/A (No N/A Y s:)No N/A 10. Plant records adequate and include: a. O & M Manual b. "As -built" engineering drawings c. Schedules and dates of equipment maintenance repairs d. Equipment data cards. 11. Permittee is meeting compliance schedule. 12. DMRs complete and include all NPDES permit required parameters. 13. ORC visitation logs available and current. 14. ORC certified at a level equal to or greater than the classification of the wastewater facility. 15. Backup Operator certified at one level less than the classification of the wastewater facility or greater. No N/A 16. Current copy of the complete NPDES permit on site. Yes No N/A 17. Facility description verified as contained in NPDES permit. Revised 7/11/00 by Belinda Henson INSPECTION REPORT NEXT PLANNED • INSPECTED BY: HSB r INSPECTION 'DMR STATUS STATUS / •C C UPDATE OPTION: TRX: 5IF KEY: NC0028916INSCEI SYSMSG: ***.DATA ADDED SUCCESSFULLY *** PERMIT--- NC0028916 FACILITY-- TROY, TOWN -,WWTP , INS TYPE CEI INSPECTION_ DATE 010625 REPORT DATE 010627 COMMENTS: 01062 5 REG/COUNTY-- 06 MONTGOMERY LOC--•TROY, RESPONSE RECEIVED DUE DATE DATE 010627