HomeMy WebLinkAboutNC0028916_Inspection_20030805•s. WA1 . Ifiir E Gray Walls Town of Troy 444 North Main St Troy NC 27371 Michael F. Easley, Governor' William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality August 5, 2003 SUBJECT: July 22, 2003 Compliance Evaluation Inspection - Town of Troy Troy WWTP Permit No: NC0028916 Montgomery County Dear Mr. Walls: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on July 22, 2003. The Compliance Evaluation Inspection was conducted by Belinda S Henson of the Fayetteville Regional Office. The facility was found to be in Compliance with permit NC0028916. The cooperation of Mr. Stephen Jarman, Grade III ORC was appreciated. As a reminder preservation of the Waters of the State can only be acquired through consistent NPDES permit compliance. Please refer to the enclosed inspection report for'additional observations and comments. If you or your staff have any questions, please call me at 910-486-1541. Sincerely, 4. Belinda S Henson Environmental Chemist cc: Stephen Bryan Jarman, ORC Central Files Fayetteville Files AtA Ni f)El dyt NCDENR Division of Water Quality 225 Green Street -Suite 714 Fayetteville, NC 28301-50431 (910)486-1541 Telephone (910)486-0707 Fax Customer Service1 877 623-7748 United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 DI 2': Li3I NC0028916 111 12 1 03/07/22 1 17 Type Inspector Fac Type 18 I 19 I t 20 LJ �J Remarks 21111111IIII111111111111111111111111111111111111166 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ----------------------Reserved---------- -------- 67 I 2 .5 169 70 lJ 1, I 71 t �, tyl 72 1,,, LJ t 731 L 174 751I 111 180 11 Section B: FacilityliData Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Troy WWTP 650 Glen Road Troy NC 27371 Entry Time/Date 10:15 AM 03/07/22 Permit Effective Date 01/02/01 Exit Time/Date 03:00 PM 03/07/22 Permit Expiration Date 04/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Stephen Bryan Jarman/ORC/910-572-5196/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted E Gray `r:alls,444,North Main St Troy NC 27371//910-572-3661/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The contract company Meritech, Inc operated this facility at the time of the inspection. As of August 1, 2003, the Town will begin operation of the wastewater treatment plant. A manual bar screen and a rotameter are used to remove trash and debris at the headworks of the plant. The rotameter operates by an ultrasonic sensor that senses the flow depth and automatically operates. A11 screenings are disposed of through the Uwharrie Environmental Landfill. (cont.) The grit removal system appeared to be Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date ci .wry 4. c Belinda S Henson � � .� • ✓ r��'G1`'' FRO WQ//910-468-1541/910-486-0707 �-5 -b3 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. 3I NPDES NC0028916 11 12 yr/mo/day 03/07/22 117 Inspection Type 18 Lc j (cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) operational. It is operated twice a day. All, grit is .disposed of through the Uwharrie Environmental Landfill. Caustic is added to the influent for pH adjustment. Candor Hosiery is moving some of their operation to the Town of Robbins facility which has caused a decrease in facility influent pH as per staff. The ORC for this facility is Stephen Jarman, Grade III operator and Pat Merritt is the Backup Operator. **AS A REMINDER THE NEW ORC AND BACKUP OPERATOR MUST COMPLETE AN APPLICATION AND SUBMIT TO TECHNICAL TRAINING AND CERTIFICATION UNIT IN RALEIGH AND CC THE FAYETTEVILLE REGIONAL OFFICE.** The influent composite sampler refrigerator temperature was 3.5 degrees Celsius. The acceptable temperature range of samples during storage and for stored sample extracts, is 1.0 to 4.4 degrees Celsius. Ref: Federal Register, July 1, 1995; 40 CFR 136; Table II.' The oxidation ditches appeared to be operating efficiently. The ditches operate in series. An anoxic zone is used to reduce nitrogen and phosphorus. The facility analyzes Mixed Liquor Suspended Solids (MLSS) on.a monthly basis. The most recent results are approximately 3500 mg/L. 1 The clarifiers sludge depths were the following: Clarifier 41: 1 foot with a tank depth of mil feet and Clarifier f2: 1.5 feet with a tank depth of 11 feet. The'facility has completed installation of the UV. system for disinfection and has been on line for approximately one month. The facility continues to add chlorine until the UV system testing has been completed. The UV system has 2 banks with 4 bulbs per bank. The system is self cleaning which injects a soap•cleaner and then wipers are activated. The cleaning occurs every 4 hours. Grease balls are manually removed from the effluent before it reaches the UV system. Grease balls are removed by a net and placed on a tray and disposed of through the county landfill. Plans are to utilize chlorine gas as a backup system for disinfection. Plans are to relocate the effluent flow from the UV system and to directly discharge to the stream and bypass the chlorine contact tank. The effluent appeared to be free of solids. The effluent composite sampler refrigerator temperature was 0.5 degrees Celsius. The tubing was clean and adequately maintained. The effluent flow meter Milltronics OCM III was calibrated July 16, 2003 by facility staff. The digester appeared to be operating adequately. The sludge holding tank appeared to have less than 1 foot in it. A land application event had occurred recently and the contract company Synagro had basically emptied the tank. The facility normally wastes 50-60 inches/week which is approximately 48,000 gallons. Biosolids are land applied under permit # WQ0001240. Two lagoons are located on site. The largest lagoon is used as a equalizing lagoon for high flows. The smaller lagoon is no longer utilized and the Town is in the process of filling it in. The following NPDES permit required parameters are analyzed by facility staff: pH, Temperature, Dissolved Oxygen and Chlorine Residual under field parameter certification # 136. All other required parameters are analyzed by Meritech, Inc. Laboratory records were reviewed for the month February 2003 and compared to Discharge Monitoring Reports (DMR). All records reviewed appeared to be accurate. A compliance evaluation for the period April 2002 through April 2003 did not reveal any monthly violations. The facility should be commended for their continued compliance of their NPDES permit. 3 NPDES NC0028916 11 12 yr/mo/day 03/07/22 117 Inspection Type 18i„i • (cont.) 2 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The ORC log was reviewed and appeared to be adequate. The facility continues progressing with their SCADA system which will further assist with daily operations. rcegivnai FIGI4-•--- _ `� lame of site to be Inspected: To "3 r1 04 I ir'� y Date: - � ��.� �. Inspector: 3eJ.;rin1.a: 5. G/enrsor JPDES #: /1/CrC) 0 '�.$ `I i L, Region: 'ro y e, , Circle the parameter or parameters performed at this site. 'ield certification # (if applicable): 1?) tesidual Chlo r in Settleable Solids p' D Conductivity, Temperatur I. Instrumentation: Does the facility have the equipment necessary to analyze field parameters as circled above? A pH meter A Residual Chlorine meter Yes es•� ;. DO meter t, A Cone for settleable solids Yes No 5. A thermometer or meter that measures temperature. Yes No No 4CCuyyt ET 5 No .04? a o:o 0 No Y5- 5 S 3. Conductivity meter III. Calibration/Analysis: 1. Is the pH meter calibrated with a 2 buffers and checked with a third buffer each day of use? 2. For Total Residual Chlorine, is a check standard :Yei analyzed each day of use? 3. Is the air calibration of the DO meter performed es each day of use? 4. For Settleable Solids, is 1 liter of sample Yes settled for 1 hour? Yes No 5. Is the temperature measuring device calibrated annually against a certified thermometer? 6. For Conductivity, is a calibration standard analyzed each day of use? Yes No No No No No No IV. Documentation: 1. Is the date and time that the sample was collected documented?&e7 No 2. Is the sample site documented? Ye `) No 3. Is the sample collector documented? cYes) No 4. Is the analysis date and time documented? C No 5. Did the analyst sign the documentation? Yes No 6. Is record of calibration documented? qes� No 7. For Settleable,Solids, is sample volume_ and 1 hour time settling time documented? Yes 8. For Temperature, is the annual calibration of the measuring device documented? S' Comments: No Please submit a copy of this completed form to the Laboratory Certification Program. DWQ Lab Certification Chemistry Lab• Courier # 52-01-01 FIELD INSPECTOR CHECKLIST REV: 04/23/2002 Section 0: 54mm2ry or in ings/Cor ments Brief Facility Description: A .84 MGD WWTP consisting of the following: dow equalization.mechanical bar screen, grit removal, dual oxidation ditches, dual secondary clarification, sludge digester, sludge holding, tank, UV di*infection and chloringtion/dechlorination(back-up). FACILITY SITE REVIEW es No N/A 1. Treatment units properly operated and maintained. es No N/A 2. Standby power or other equivalent provision provided. SsP No N/A 3. Adequate alarm system for power or equipment failure available. 4. Sludge disposal procedures appropriate: No N/A a. Disposal of sludge according to regulations j7 No N/A b. State approval for sludge disposal received. No N/A 5. Sufficient sludge disposed of to maintain treatment process equilibrium. &e ~ No N/A 6. The ORC and Backup Operator are officially designated with NCDENR/DWQ Training and Certification Unit. 7e- No N/A 7. Adequate spare parts and supplies inventory maintained. es) No N/A 8. Plant has general safety structures such as rails around or covers over tanks, pits, or wells. No N/A 9. Plant is generally clean, free from open trash areas. 10. Screening: .el No N/A a. Manual • No N/A b. Mechanical Yes 'oD N/A c. Buildup of debris No N/A d. Screenings properly disposed of. 11. Grit Removal: Yes N N/A a. Excessive organic content in the grit chamber Yes 6Is) N/A b. Excessive odors c� No N/A c. Grit properly disposed of. Page 2 12. Primary clarifier:. Yes No a. Excessive gas bubbles Yes No �/A b. Black and odorous wastewater Yes No N/A c. Poor suspended solids 'removed , Yes No N/A d. Excessive buildup of solids in center well of circular clarifier Yes No N/A e. Weirs level Yes No N/A f. Weir blockage Yes No N/A g. Evidence of short circuiting Yes No N/A h. Lack of adequate scum removal Yes No N/A i. Excessive floating sludge Yes No N/A j. Broken sludge scraper. 13. Trickling Filter: Yes No ei a. Trickling filter ponding(indicating clogged media) Yes No N/A b. Leak at center column of trickling filter's distribution arms Yes No `. N/A c. = Uneven distribution of flow 'on trickling filter surface Yes No N/A d. Uneven or discolored growth Yes No N/A e. Excessive sloughing of growth Yes No N/A f Odor Yes No N/A g. Clogging of trickling filter's distribution arm orifices Yes No N/A h. Filter flies, worms,or snails; - - 14. Activated. Sludge Basins/Oxidation Ditches: Yes N/A a. Dead spots Yes No tN/ ' ' b. Failure of surface aerators Yes @' N/A c. Air rising in clumps Yes Eta' N/A d. Dark foam or bad color Yes N/A e. Thick billows of white, sudsy foam Yes No la ff. Air rising unevenly Yes No ( g. Excessive air leaks in compressed air piping. Yes No N/A Yes No N/A Yes No N/A Yes No N/A 15. Stabilization Ponds/Lagoons: a. Excessive weeds including duckweed in stabilization ponds b. Dead fish or aquatic organisms c. Buildup of solids around influent pipe d. Excessive scum on surface. Page 3 Yes (15} N/A Yes o") N/A Yes N/A Yes o N/A Yes N/A Yes 'OE- N/A No N/A Yes N/A Yes J N/A Yes CTo JN/A 16. Secondary Clarifier: Excessive gas bubbles on surface Level overflow weirs Weir blockage Evidence of short circuiting Excessive buildup of solids in center well of circular clarifier Pin floc in overflow Effective scum rake Floating sludge on surface Excessive high sludge blanket Clogged sludge withdrawal ports, on secondary clarifier. 17. Yes No Nit Yes No N/A Yes No N/A Yes No N/A Yes No N/A Yes No N/A Yes No N/A Yes iSO N/A Yes N/A Yes No N/A Yes No N/A Yes No N/A Yes No N/A Yes No N/A No N/A a. b. c. d. e. f. g. h. i. j. Filtration: a. Filter surface clogging b. Short filter run c. Gravel displacement of filter media d. Loss of filter media during backwashing e. Recycled filter backwash water in excess of 5 percent f. Formation of mudballs in filter media. 18. Chlorination Unit: a. Sludge buildup in contact chamber b. Gas bubbles c. Floating scum and/or solids d. Adequate ventilation of chlorine feeding room and storage area e. NIOSH-approved 30 minute air pack f. All standing chlorine cylinders chained in place g. All personnel trained in the use of chlorine h. Proper chlorine feed, storage, and reserve supply. 19. Ultraviolet radiation disinfection present and in use. 20. Yes No N/A Yes No N/A Yes No N/A Yes to N/A Yes N/A Yes No N/A Yes No N/A Dechlorination: a. Proper storage of sulfur dioxide cylinders b. Adequate ventilation of sulfur dioxide feeding room c. Automatic sulfur dioxide feed or feedback control operating properly. 21. Aerobic Digester: a. Excessive foaming in tank b. Noxious odor c. Mechanical aeration failure d. Clogging of diffusers. Page 4 Yes No Yes No N/A Yes N/A Yes N/A Yes e N/A Yes N/A Yes No N/A N/A Yet No N/A Yes No A`' Yes No N/A Yes No N/A Yes No N/A 22. Anaerobic Digester: a. Floating cover tilting b. Gas burner operative 23. Sludge Drying and/or disposal: a. Poor sludge distribution on drying beds b. Vegetation in drying beds c. Dry sludge remaining in drying beds d. Dry sludge stored on site e. Filtrate from sludge drying beds returned to front of plant f. Sludge disposal through county landfill. g. Sludge -land applied. 24. Filter Press: a. High level of solids in filtrate from filter presses or vacuum filters b. Thin filter cake caused by poor dewatering c. Sludge buildup on belts and/or rollers of filter press d. Excessive moisture in belt filter press sludge cake. 25. Polishing Ponds or Tanks: Yes No a. Objectionable odor, excessive foam, floating solids, or oil sheens on Yes No N/A Yes No N/A Y) No N/A Yes . o' N/A Yes No N/A W No N/A Yeg No N/A fes?No N/A Yes �c'e N/A Yes No Yes_.;g6% N/A s No N/A b. c. water surface Solids or scum accumulations in tank or at side of pond Evidence of bypassed polishing ponds or tanks because of low capacity. 26. Plant Effluent: a. Excessive suspended solids, turbidity, foam, grease, scum, color, and other macroscopic particulate matter present b. Potential toxicity (dead fish, dead plant at discharge) c. Outfall discharge line easily accessible. 27. Flow Measurement: Proper placement of flow measurement device Flow meter calibrated Buildup of solids in flume or weir Broken or cracked flume or weir Clogged or broken stilling wells Weir plate edge corroded or damaged Flow measurement error less than 10%. a. b. c. d. e. f. g. Page 5 No N/A C.61,§) No N/A 'e! No N/A Yes No N/A 28. Sampling: a. Sampling and analysis completed on parameters specified by permit b. Composite sample temperatures maintained at 4 degrees Celsius or less (but above freezing) during sampling c. Contract laboratory used for sample analysis d. Effluent composite samples obtained are flow proportional. RECORDKEEPING AND REPORTING e7 No N/A 1. Records and reports maintained as required by permit. es' No N/A 2. All required information available, complete, and current. Ye ' No N/A 3. Records maintained for 3 years and all sludge records maintained for 5 years. es No N/A 4. Analytical results consistent with data reported on DMRs. 5. Sampling and analyses data adequate and include: es ?No N/A a. Dates, times, and location of sampling No N/A b. Name of individual performing sampling No N/A c. Results of analyses and calibration No. N/A d. Dates of analyses es, No N/A e. Name of person performing analyses. 6. Monitoring records adequate and include: Yes No N/A a. Monitoring charts kept for 3 years VD No N/A b. Flowmeter calibration records kept for 3 years. Yes No N/A 7. The pH meter is calibrated daily with two buffers and checked with a third buffer and properly documented. Yes1 No N/A 8. Expiration dates of pH buffers adequate. Yes No N/A 9 All thermometers used in NPDES permit reporting is calibrated annually with an NIST certified thermometer or a traceable thermometer annually and documented. Ye o N/A 10. The following NPDES permit required parameters are analyzed on site: pH, Temperature, Dissolved Oxygen and Chlorine Residual. Page 6 Yes No N/A Yes No Yes No (N/—) No Yes No (Yes No Yes No N/A N/A N/A Yes No Q' e� No N/A Yes No es No N/A Yes) No N/A Yes No N/A 20. Yes No N/A 21. Yes No N/A CY) No N/A Yes . No N/A 24. 11. The NPDES permit required parameter Total Chlorine Residual is analyzed by approved method. 12. BOD incubator temperature maintained at 20 +/- 1 Degrees Celsius and the temperature maintained in a log for every day of operation. 13. Fecal coliform incubator maintained at 44.5 +/- 0.2 Degree Celsius and the temperature maintained in a log for every day of operation. 14. Plant records adequate and include: a. O & M Manual b. "As -built" engineering drawings c. Schedules and dates of equipment maintenance repairs d. Equipment data cards. 15. Permittee is meeting compliance schedule. 16. DMRs complete and include all NPDES permit required parameters. 17. The facility has a permitted flow greater than 5 MGD and is required to operate seven days per week 24 hours a day. 18. ORC visitation logs available and current. 19. ORC certified at a level equal to orgreater than the classification of the wastewater facility. Backup Operator certified at one level less than the classification of the wastewater facility or greater. Current copy of the complete NPDES permit on site. 22. Facility description verified as contained in NPDES permit. 23. Facility analyzes process control parameters for example: MLSS, MCRT, Settleable Solids and others that are applicable. Industrial Waste Surveys (IWS) sent to all possible Significant Industrial Users (SIUs) within the last five years (especially new industries). Revised 7/16/01 by Belinda Henson