Loading...
HomeMy WebLinkAboutNC0025445_Randleman Pretreatment Audit Report_20210602ROY COOPER Governor DIONNE DELLI-GATTI Secretary S. DANIEL SMITH Director Ms. Lisa Osthues Pretreatment Coordinator City of Randleman 168 Nathan Dudley Road Clinton, North Carolina 28328 NORTH CAROLINA Environmental Quality June 2, 2021 SUBJECT: Pretreatment Audit Inspection (PAI) City of Randleman NPDES# NC0025445 Randolph County Dear Ms. Osthues: On May 13, 2021 a Pretreatment Audit Inspection (PAI) was performed by Jim Gonsiewski of the Winston-Salem Regional office. Ms. Lisa Osthues, pretreatment coordinator for the City of Randleman, was present. The purpose of this inspection was to determine the effectiveness of the pretreatment program, which included: a detailed file review, review of the POTW plant performance, sampling, and compliance judgement program, and adherence to the enforcement response plan (ERP). Additionally, an inspection of the Deep River Dyeing facility was conducted in conjunction with an inspection by the City of Randleman. Background This is a 1.745 MGD permitted facility. The City has one (1) Significant Industrial User (SIU) which is non -categorical. The publicly owned treatment works (POTW) was non -compliant for BOD in April 2020 due to a tertiary filter failure. The repairs were made and the POTW returned to compliance. Pretreatment Program Element Review The Headworks Analysis (HWA) was submitted on May 19, 2017. The HWA was approved on August 16, 2017. The next HWA is due on June 1, 2022. The Industrial Waste Survey (IWS) was submitted on March 2, 2018. The IWS was approved on May 25, 2018. The next IWS is due on February 28, 2023. The Sewer Use Ordinance (SUO) was approved on February 4, 2013. TM D_EQ� North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1 450 West Hanes Mill Road. Suite 300 I Winston-Salem, North Carolina 27105 336.776.9800 The Enforcement Response Plan (ERP) was approved on August 11, 2020. LTMP File Review The Long Term Monitoring Plan (LTMP) was approved on October 10, 2011 and is being conducted at the proper locations and frequencies. Industrial User Permit (IUP) File Review A review of the file for Deep River Dyeing (#0004) revealed that the monitoring data was well organized and compliant. The slug control plan for Deep River Dyeing 00004) was in good order. Action Items No other action items were noted. The pretreatment program is considered satisfactory. Ms. Osthues maintains an excellent program. If you have any questions please contact Jim Gonsiewski or me at (336) 776-9800. Sincerely, E—OP. yDocu8llgn.d b`y: t�JMItr 146649E226C94EA... Lon T. Snider Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ — WSRO Enclosure: PAI Report cc: PERCS Unit — Mike Montebello (Electronic Copy) Michael Glass — City of Randleman (Electronic Copy) WSRO Electronic Files Laserfiche Files GQE Os40M1ntlM 01 YvrwMOUI w.0 North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 West Hanes Mill Road, Suite 300 I Winston-Salem, North Carolina 27105 336.776.9800 NC• NORTH CAROLINA DIVISION OF WATER RESOURCES PRETREATMENT AUDIT REPORT Water Resources ENVIRONMENTAL DUALITY Background Information [Complete prior to audit; review Program Info Database Sheet(s)] 1. Control Authority (POTW) Name: City of Randleman 2. Control Authority Representative(s): Lisa Osthues and Michael Glass 3. Title(s): Contracting Pretreatment Consultant / ORC 4. Address of POTW: Mailing 204 South Main Street City Randleman, NC Zip Code 27317 Phone Number (336) 498-2254 Fax Number E-Mail wwtracitvofrandleman.com, lisaopretreatAgmail.com 5. Audit Date 05/ 13 /2021 6. Last Inspection Date: 12/ 17 / 2019 Inspection Type: ® PCI ❑ Audit 7. Has Program Completed All Requirements from the Previous Inspection and Program Info Sheet(s) ? ® Yes ❑ No If No, Explain. 8. In the last year has the POTW experienced any NPDES or Sludge Permit compliance problems? ® Yes ❑ No If Yes, Explain. Non -compliant for BOD in April 2020 due to a tertiary filter failure. Repairs made and returned to compliance. 9. Is POTW under an Order That Includes Pretreatment Conditions? ❑ Yes ® No Order Type and Number: Are Milestone Dates Being Met? El Yes ❑ No ❑ NA Parameters Covered Under Order ICIS Coding Main Program Permit Number INICIOI0I2 15 14 14 15 1 10. Current Number of Significant Industrial Users (SIUs)? 11. Number of SIUs with No IUP; or with an Expired IUP? 12. Number of SIUs Not Inspected by POTW in Last Calendar Year? 13. Number of SIUs Not Sampled by POTW in Last Calendar Year? MM/DD/YY 05 11'i 121 1 14. Number of SIUs in SNC for Limits Violations During Either of Last 2 Semi -Annual Periods? 15. Number of SIUs in SNC for Reporting During Either of Last 2 Semi -Annual Periods? 16. Number of SIUs in SNC with Pretreatment Schedule? 1 0 0 0 0 0 0 17. Number of SIUs on Schedules? 0 18. Current Number of Categorical Industrial Users (CIUs)? 19. Number of CIUs in SNC? 0 NA NC DWR Pretreatment Audit Form Revised: December 2016 Page 1 20. PRETREATMENT PROGRAM ELEMENTS REVIEW- Review POTW files, verify POTW has copy of each Program Element in their File, complete with all supporting documents and PERCS Approval Letter, and dates consistent with Program Info: Program Element Last Submittal Date In file? Last Approval Date In file Date Next Due, If Applicable 06/01/2022 Headworks Analysis (HWA) 05/19/2017 Yes ❑ No 08/16/2017 ►1 Yes ❑ No Industrial Waste Survey (IWS) 03/02/2018 /1 Yes ❑ No 05/25/2018 /1 Yes ❑ No 02/28/2023 Sewer Use Ordinance (SUO) 01/03/2013 ►1 Yes ❑ No 02/04/2013 /1 Yes ❑ No NA Enforcement Response Plan (ERP) 05/15/2020 /1 Yes ❑ No 08/11/2020 ►1 Yes ❑ No NA Long Term Monitoring Plan (LTMP) 09/16/2011 // Yes ❑ No 10/10/2011 /1 Yes ❑ No NA Legal Authority (Sewer Use Ordinance-SUO) 21. Do you have any towns and/or areas from which you receive wastewater which are not in your annexed jurisdiction? ❑ Yes ® No If yes, Please list these towns and/or areas. 22, If yes to #21, Do you have current Interjurisdictional Agreements (IJAs) or other Contracts? ❑ Yes ❑ No ® NA A copy, if not already submitted, should be sent to Division. 23. If yes to #21, Have you had any trouble working with these towns or districts? ❑ Yes ❑ No ® NA If yes, Explain. 24. Date of Last SUO Adoption by Local Council 02/05/2013 25. Have you had any problems interpreting or enforcing any part of the SUO? ❑ Yes ® No If yes, Explain. Enforcement (Enforcement Response Plan-ERP) 26. Did you send a copy of the ERP to your industries? ® Yes ❑ No Emailed updated copy to industry 5/11/2021 If no, POTW must send copy within 30 days. 27. Have you had any problems interpreting or enforcing any part of the ERP (i.e. any adjudication, improper enforcement, etc? ['Yes ® No If yes, Explain. Note to discuss hard copy 'wet signature' issue 28. List Industries under a Schedule or Order and Type of Schedule or Order NA Resources 29. Please Rate the Following: S=Satisfactory M=Marginal U=Unsatisfacto Rating Explanation, if Unsatisfactory Personnel Available for Maintaining POTW's Pretreatment Program IS ❑M ❑U Access to POTW Vehicles for Sampling, Inspections, and Emergencies /1S ❑M ❑U Access to Operable Sampling Equipment POTW has portable sampler and Industry has its own. ►1S ❑M ❑U Availability of Funds if Needed for Additional Sampling and/or Analysis ►1S ❑M ❑U Reference Materials S ❑M ❑U Staff Training (i.e. Annual and Regional Workshops, Etc.) ►1S ❑M ❑U Computer Equipment (Hardware and Software) ►1S ❑M ❑U NC DWR Pretreatment Audit Form Revised: December 2016 Page 2 30. Does the POTW have an adequate data management system to run the pretreatment program? ® Yes ❑ No Explain Yes or No. Excel spreadsheets and other Microsoft form products. 31. How does the POTW recover the cost of the Pretreatment Program from their industries? Explain. BOD and COD surcharges for overages. Public Perception/ Participation 32. Are there any local issues affecting the pretreatment program (e.g.. odor, plant closing, new or proposed plants)? ❑ Yes ® No If yes, Explain. 33. Has any one from the public ever requested to review pretreatment program files? ❑ Yes ® No If yes, Explain procedure. If no, how would the request be addressed? Make appointment and allow to copy public records. 34. Has any industry ever requested that certain information remain confidential from the public? ❑ Yes ® No If yes, Explain procedure for determining whether information qualified for confidential status, as well as procedure for keeping files confidential from public. If no how would the request be addressed? See Section 7 of SUO on Confidential Information. Would need to comply with requirements in ordinance if private entity. 35. In addition to annual inspection, does the POTW periodically meet with industries to discuss pretreatment? ® Yes ❑ No ORC stops by occasionally to check on discharge and during sampling twice a year, and Industry and Consultant speak on the phone or communicate by email. 36. Is the public notified about changes in the SUO or Local Limits? ® Yes ❑ No Would be included as an agenda item for Board meeting and also included in minutes. 37. Were all industries in SNC published in the last notice? ❑ Yes ❑ No NA — none in SNC Permitting (Industrial Waste Survey-IWS) 38. How does the POTW become aware of new or changed Users? • City Hall • Prior year Industrial Waste Surveys • The North Carolina Manufacturers Register • The Randleman Chamber of Commerce (http://randlemanchamber.com/list/) • The ORC is in close contact with the Water Production Supervisor and the Collection Systems Supervisor. Potential impacts are relayed as found. • The ORC conducts grease trap inspections. Inspections are not limited to existing traps/filters, but also include new and expanding or changing businesses/industries. • The Better Business Bureau 39. Once the POTW becomes aware of new or changed Users, how does the POTW determine which industries have the reasonable potential to adversely impact the WWTP and therefore require a new permit or a permit revision? (Who is an SIU?) • Water/sewer records — review flow volumes • Make contact with business and request to complete IWS short form as needed • Determine POCs • Test as needed — pollutant scan • Review process • Follow with long form as needed 40. Does the POTW receive waste from any groundwater remediation projects (petroleum, CERCLA) or landfill leachate? ❑Yes No If Yes, How many are there? Please list each site and how it is permitted, if applicable. 41. Does the POTW accept waste by (mark if applicable) ❑ Truck ['Dedicated Pipe ® NA 42. If the POTW accepts trucked waste, what controls are placed on this waste? (example. designated point, samples drawn, manifests required) NA 43. How does the POTW allocate its loading to industries? Mark all that apply ❑ Uniform Limits ® Historical Industry Need ❑ By Surcharge ❑ Categorical Limits ['Other Explain Other: NC DWR Pretreatment Audit Form Revised: December 2016 Pace 3 44. Review POTW's copies of current allocation tables for each WWTP. Are there any over allocations? ® Yes ❑ No If yes, what parameters are over allocated? There is a theoretical overallocation for silver due to the use of the chronic silver stream standard by the state. 45. If yes to #44, What is being done to address the over allocations? (short-term IUPs, HWA to be revised, pollutant study, etc.) NCDEQ has not required programs to update LTMP plans but has begun enforcing the chronic standard for HWA. There are no silver dischargers to this plant. Silver has been added to LTMP informally to collect data. City has requested that their contract lab test to at least 0.002 mg/L for future analyses. City is participating the NCPC silver workgroup to discuss this issue with NCDEQ as this is a statewide issue for many programs/plants. City has completed the silver survey for the NCPC. City will monitor its single industry for silver in second half of 2021. 46. Does the POTW keep pollutant loading in reserve for future growth / safety? ® Yes ❑ No If yes, what percentage of each parameter Actually not necessary at this time, but will do this and determine as needed 47. Has the POTW experienced any difficulty in allocation? (for example: adjudication by an industry) ❑ Yes ® No If yes, Explain. 48. How does the POTW decide on which pollutants to limit in the permits? Monitor for? (for example: were only those pollutants listed on the application limited; categorical parameters; NPDES Pollutants of Concern) POCs for NPDES; pollutant scans; IWS Long form; type of industry also considered; categorical determined; changes to process for IUP renewals 49. How does the POTW decide what the monitoring frequency should be for the various pollutants in industry permits? Explain. POTW still conducts 2 times annually to address POCs for plant. Frequency for industry is based on numerous factors including, but not limited to, volume of discharge, typical load of discharge, types of pollutants (e.g. primary or additional), potential to impact POTW, available loading at POTW. Permit Compliance 50. Does the POTW currently have or during the past year had any permits under adjudication? ❑ Yes ® No If yes, which industries? What was (will be) the outcome of the adjudication? 51. Demonstrate how the POTW judges compliance. This should include compliance judgment on all violations of limits, reporting requirements, and permit conditions, as well as for SNC. Compliance judgement spreadsheet is used for all pollutant judgement. Postmarks for reports are now used for reporting timeframe compliance. Annual inspections are used to determine compliance with other permit conditions. 52. Does the POTW use the Division's model inspection form or equivalent? ® Yes ❑ No If no, does the POTW form include all Division data? ❑ Yes ❑ No 53. Were all SIUs evaluated for the need of a slug/spill control plan during their most recent inspections? ® Yes ❑ No If no, Explain. 54. What criteria are used to determine if a slug/spill control plan is needed? In general, we require all SIUs to have a slug/spill plan. 55. What criteria does the POTW use to determine if a submitted slug/spill control plan is adequate? Must have chemical/product control, contact information to alert emergency personnel and POTW, training requirements, post spill procedures. 56. How does the POTW decide where the sample point for an SIU should be located? Current SIU sampling point already in place. Future points would be determined by attempting to obtain representative samples, free from side streams, post all pretreatment, accessible safely. 57. Has the POTW established a procedure to ensure that representative samples will be taken by the POTW or SIU each time? (example: correct location; proper programming of sampler; clean equipment; swirling the sample bucket uniformly) POTW: ® Yes ❑ No SIU: ® Yes ❑ No If yes, Explain. SIUs samples are collected by a certified contract laboratory using the industry's approved sampler. POTW samples are collected by City personnel only following required sampling procedures and submitted to a contract laboratory using chains of custody and proper preservation. 58. Who performs sample analysis for the POTW for Metals Meritech Conventional Parameters Meritech Organics Meritech NC DWR Pretreatment Audit Form Revised: December 2016 Page 4 59. Explain the Chain of Custody Procedure used for both in house and commercial lab samples. Meritech chain of custody forms are used for both POTW and industry sampling. POTW conducted testing is recorded on POTW form. Long/Short Term Monitoring Plan (L/STMP) and Headworks Analysis (HWA) 60a. Is LTMP/STMP Monitoring Being Conducted at Appropriate Locations and Frequencies? ® YES ❑ NO 60b. Are Correct Detection Levels being used for all LTMP/STMP Monitoring? ® YES ❑ NO NOTE: When POTW changed to new lab, some issues with TSS detection levels. These have been addressed with the lab. If other detection levels are not met, request lab repeat testing where possible or determine if it is matrix interference. Note that this LTMP plan is older an lists an incorrect detection level for TSS. The lowest detection level possible for TSS per the NC lab branch is 2.5 mg/L. Older LTMP plans have it listed at 2. 60c. Is LTMP/STMP Data Maintained in Table or Equivalent? ® YES ❑ NO Is Table Adequate? ❑ YES ❑ NO 60d. All LTMP/STMP effluent data on Discharge Monitoring Report (DMR)? ® YES ❑ NO Division Inspector, verify yourself! 60e. If NO to any above, list violations 60f. Should any Pollutants of Concern be Eliminated from or Added to LTMP/STMP? ® YES ❑ NO If yes, which ones? Eliminated: Added: Silver 61. Do you complete your own headworks analysis (HWA) ? ® Yes ❑ No If no, who completes your HWA? Phone ( ) -- 62. Do you have plans to revise your HWA in the near future? ® Yes ❑ No If yes, what is the reason for the revision? (mark all that apply) ❑Increased average flow ❑NPDES limits change ®More LTMP data available ❑Resolve over allocation ❑5 year expiration ®Other Explain. Will have silver data available soon. Also, one industry has left the City. The City also applied for its NPDES permit renewal and once received, the POTW has 180 days to update the Headworks analysis. 63. In general, what is the most limiting criteria of your HWA? ❑Inhibition ® Pass Through ❑Sludge Quality 64. Do you see any way to increase your loading in the future (Example: obtaining more land for sludge disposal)? ❑ Yes ❑ No Explain. This is not necessary at this time with only one SIU. Summary 65. Do you plan any significant changes to the pretreatment program or changes to the WWTP that may affect pretreatment? None planned. NC DWR Pretreatment Audit Form Revised: December 2016 Page 5 INDUSTRIAL USER PERMIT (IUP) FILE REVIEW (3 IUP FILE REVIEWS AND 1 IU IN 66. User Name 1. Deep River Dyeing 2. NA 3. NA 67. IUP Number 0004 68. Does File Contain Current Permit? // Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No 69. Permit Expiration Date 12/31/21 70. Categorical Standard Applied (I.E. 40 CFR, Etc.) Or N/A NA 71. Does File Contain Permit Application Completed Within One Year Prior to Permit Issue Date? Completed 7/20/2016; permit renewed January 1, 2017. Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No 72. Does File Contain Inspection Completed Within Last Calendar Year? Inspected 12/10/2020 /1 Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No 73. a. Does File Contain Slug/Spill Control Plan? b. If No, is One Needed? (See Inspection Form from POTW) a. r Yes ■ No b. ■Yes •No a. ■ Yes ■ No b. ■Yes •No a. ■ Yes ■ No b. •Yes ■No 74. For 40 CFR 413 and 433 TTO Certification, Does File Contain a Toxic Organic Management Plan (TOMP)? ❑Yes❑NoEN/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A 75. a. Does File Contain Original Permit Review Letter from Division? b. All Issues Resolved? a. ►1Yes ■No b.❑Yes❑No❑N/A a. ■Yes ■No b.❑Yes❑No❑N/A a. •Yes ■No b.❑Yes❑No❑N/A 76. During Most Recent Semi -Annual Period, Did POTW Complete its Sampling as Required by IUP, including Flow? ►1 Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No 77. Does File Contain POTW Sampling Chain -Of -Custody Forms? Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No 78. During Most Recent Semi -Annual Period, Did SIU Complete its Sampling as Required by IUP, including Flow? ®Yes❑No❑N/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A 79. During Most Recent Semi -Annual Period, Did SIU submit all reports on time? ®Yes❑No❑N/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A 80a. For categorical IUs with Combined Wastestream Formula (CWF), does file include process/dilution flows as Required by IUP? ❑Yes❑NoON/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A 80b. For categorical IUs with Production based limits, does file include production rates and/or flows as Required by IUP? ❑Yes❑No®N/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A 81. During Most Recent Semi -Annual Period, Did POTW Identify All Limits Non -Compliance from Both POTW and SIU Sampling? ❑ Yes ❑ No None ❑ Yes ❑ No ❑ Yes ❑ No 82. During Most Recent Semi -Annual Period, Did POTW Identify All Reporting Non -Compliance from SIU Sampling? ❑Yes❑NoEN/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A 83. a. Was POTW Notified by SIU (Within 24 Hours) of All Self- Monitoring Violations? b. Did Industry Resample and submit results to POTW within 30 Days? c. If applicable, did POTW resample and obtain results within 30 days of becoming aware of SIU limit violations in the POTW's sampling of SIU? a.❑Yes❑NoEN/A b.❑Yes❑NoEN/A c.❑Yes❑NoEN/A a.❑Yes❑No❑N/A b.❑Yes❑No❑N/A c.❑Yes❑No❑N/A a.❑Yes❑No❑N/A b.❑Yes❑No❑N/A c.❑Yes❑No❑N/A 84. During Most Recent Semi -Annual Period, Was SIU in SNC? ❑ Yes /1 No ❑ Yes ❑ No ❑ Yes ❑ No 85. During Most Recent Semi -Annual Period, Was Enforcement Taken as Specified in POTW's ERP (NOVs, Penalties, timing, etc.)? ❑Yes❑No:N/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A 86. Does File Contain Penalty Assessment Notices? ❑Yes❑No®N/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A 87. Does File Contain Proof Of Penalty Collection? ❑Yes❑NoCAN/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A 88. a. Does File Contain Any Current Enforcement Orders? b. Is SIU in Compliance with Order? a.❑Yes❑NoEN/A b.❑Yes❑NoEN/A a.❑Yes❑No❑N/A b.❑Yes❑No❑N/A a.❑Yes❑No❑N/A b.❑Yes❑No❑N/A 89. Did POTW Representative Have Difficulty in Obtaining Any Requested Information For You? ❑ Yes // No II Yes ❑ No ❑ Yes ❑ No FILE REVIEW COMMENTS: Well organized files. All requested information was easily accessible. NC DWR Pretreatment Audit Form Revised: December 2016 Page 6 INDUSTRY INSPECTION ICIS CODING: Main Program Permit Number MM/DD/YY INICI0101 1 1 1 1 I 1051131211 1. Industry Inspected: Deep River Dyeing 2. Industry Address: 225 Poplar Street. Randleman, NC 27317 3. Type of Industry/Product: Textile dyeing 4. Industry Contact: Jake Marsh Title: Owner Phone: 336-498-4181 Fax: 336-498-7252 5. Does the POTW Use the Division Model Inspection Form or Equivalent? ® Yes ❑ No 6. Did the POTW Contact Conduct the Following Parts of the Industrial Inspection Thoroughly? Comments: A. Initial Interview ® Yes ❑ No B. Plant Tour ® Yes ❑ No C. Pretreatment Tour ® Yes ❑ No D. Sampling Review ® Yes ❑ No E. Exit Interview ® Yes ❑ No Industrial Inspection Comments: Met with the plant manager, Nate Marsh. Deep River Dyeing begane operations at the facility in 1973. Currently the plant has three shifts a day and operates four days a week. 55 people work at the facility at this time. The facility dyes fabrics for various uses. There are 19 dyeing machines at the facility of which two are obsolete and no longer used. The pretreatment process consists of lint screens, flow equalization with bubble defusers, and ozone treatment for BOD, COD, and color removal. The facility was very well run amd maintained. Audit SUMMARY AND COMMENTS: Audit Comments: A very well run program. Requirements: None Recommendations: None NOD: ❑ Yes ® No NOV: El Yes ® No QNCR: El Yes ® No POTW Rating: Satisfactory Marginal ❑ Unsatisfactory El Audit COMPLETED BY: Jim Gonsiewski DATE: 05/28/2021 Michael Montebello - PERCS and Winston-Salem Regional Office NC DWR Pretreatment Audit Form Revised: December 2016 Page 7 United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code 1 I� I 2[ NPDES yr/mo/day Inspection Type Inspector Fac I 3 I NC0025445 111 121 21/05/13 117 18 n 191 S I 201 Type 211111 1 1 1 I I III I II I I I II I I I I I 1 1 I I I 1 III III I II l i 166 Inspection Work Days 671 I Facility Self -Monitoring 701LJ � Evaluation Rating I 71 B1 I tyI 72 QA 12,j 731 I I I Reserved 174 71 I I I 1 1 I 1 _180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Randleman WWTP 3475 Applewood Rd Randleman NC 27317 Entry Time/Date 10:OOAM 21/05/13 Permit Effective Date 17/08/01 Exit Time/Date 12:45PM 21/05/13 Permit Expiration Date 21/08/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Garry Michael Glass/ORC/336-498-2254/ Other Facility Data Name, Address of Responsible Official/tle/Phone and Fax Number Contacted Nick Holcomb,204 S Main St Randleman NC 27317181411336-495-7500/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Records/Reports Pretreatment Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Jim J Gonsiewski of Inspector(s) Agency/Office/Phone and Fax Numbers Date Docuaronedby: DWR/Division of Water Quality/336 776 9704/ 5/28/2021 po.. C- C t e.Aki c Et97689F179D46F... Signature of Managemento a Revinedewer Agency/Office/Phone and Fax Numbers Date L..o# 'C. SMlcr 6/2/2021 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 NPDES yr/mo/day Inspection Type 31 NC0025445 111 121 21 /05/13 117 18 LG.] 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The Pretreatment Audit Inspection (PAI) was conducted on May 13, 2021. As part of the inspection, the SIU Deep River Dyeing was also inspected. The POTW was found to be in compliance with a very well run pretreatment program. Page# 2 Permit: NC0025445 Inspection Date: 05/13/2021 Owner - Facility: Randleman VWVTP Inspection Type: Pretreatment Audit Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑III application? Is the facility as described in the permit? •❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ E ❑ Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? •❑ ❑ ❑ Comment: Page# 3