Loading...
HomeMy WebLinkAboutNC0028916_Lab Certification Inspection_20060626O OP W AT �i9, William G. Ross Jr., Secretary .; ` r North Carolina Department of Environment and Natural Resources 'C Alan W. Klimek, P.E. Director Division of Water Quality 5350 Mr. Joseph Shields Town of Troy WWTP 650 Glen Rd. Troy, NC 27371- June 26, 2006 RECEIVES ... JUL 2 5 2015 DENR - FAYEITEVILLEREGIONAL OFFICE ' SUBJECT: Laboratory Certification Maintenance Inspection Dear Mr. Shields: RECEIVED K•�. {?ent. e5f ENR JUN' 2 7 2006 Winston.S;iem Regional Office - Michael F. Easley, Governor Enclosed is a report for the inspection performed on, June 20, 2006 by Mr. David Livingston. Where deficiencies are cited in this report, a response is required as well as for all lettered comments and/or recommendations. Within thirty days of receipt, please supply this office with a written item for item description of how these deficiencies, comments and/or recommendations were; corrected. If the deficiencies cited in the enclosed report are not corrected, enforcement actions will be recommended. For certification maintenance, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of this report by email, or if you have questions or need additional information please contact us at 919-733- 3908. Enclosure cc: David Livingston Winston-Salem Regional Office Sincerely, James W. Meyer. Laboratory Section Laboratory Section 1623 Mail Service Center; Raleigh, NC 27699-1623 4405 Reedy Creek Road; Raleigh, NC 27607 Phone (919) 733-3908 / FAX (919) 733-2496 / Internet: www.dwglab.org. Nne orthCarolina Naturally An Equal Opportunity/Affirmative Action Employer- 50% Recycled/10% Post Consumer Paper LABORATORY NAME: On -Site Inspection Report Town of Troy WWTP NPDES #NC0028916 ADDRESS: 650 Glen Road Troy, NC 27371 CERTIFICATE NO: #5350 DATE OF INSPECTION: 6/20/2006 TYPE OF INSPECTION: Maintenance Field Inspection EVALUATOR: Mr. David G. Livingston LOCAL PERSON(S) CONTACTED:Mr. Joseph Shields I. INTRODUCTION: This laboratory was inspected to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. II. GENERAL COMMENTS: The laboratory is spacious and well equipped. All facilities and equipment are well maintained. Records are wellkept and most data looked good. Some further quality control procedures need to be implemented. III. DEFICIENCIES, REQUIREMENTS; COMMENTS AND RECOMMENDATIONS: RESIDUAL CHLORINE Note: Plant is UV operatedand just keeping Residual Chlorine as a back up parameter now. (A) COMMENT: -If the laboratory- does analyze for Residual Chlorine, an annual curve must be - established before samples can be analyzed.. REQUIREMENT: The laboratory must do a five point annual curve or a three point curve each analysis day. (B) COMMENT: After the laboratory establishes the annual 'curve verify the "gel" type standard against the,annual curve. REQUIREMENT: Once the annual curve has been establishedanalyze: the "gel" standard to assign the initial value of the :"gel" standard. Each analysis day .the "gel" standard must be checked and found to be within +/- 10% of the initial value. FYI: Since the laboratory is keeping Residual Chlorine as a backup to the UV dechlorination system, the laboratory will still be responsible for analyzing a Performance -Evaluation (PE) sample each year. Before analysis of the PE sample the lab must establish an annual curve._ Page 2 Town of Troy WWTP #5350 pH (C) COMMENT: The laboratory is calibrating the pH meter with 3 buffers, (4, 7, and 10) but does not reread the 7 buffer as a check. REQUIREMENT: After calibration analyze a check buffer. The laboratory must document that the pH 7 buffer is checked after calibration and is within 0.1 pH units of the true value: IV. PAPER TRAIL INVESTIGATION: This consisted of comparing data on DMRs with the values obtained on laboratory bench worksheets. All data reviewed for the months of February, March and., April 2006 indicated no problems in proper transfer of data for reporting purposes. However, in April the laboratory failed to report any.Dissolved Oxygen readings. Revise and resubmit your. April DMR to. the State: Send in the revised April DMR with yourresponse to this report. V. CONCLUSIONS: Correcting the above cited comments by implementingthe requirements and recommendations will help this lab to produce quality data and. meet certification requirements. Please respond to the lettered comments. Report prepared by: David G. Livingston Date: 6/23/06