Loading...
HomeMy WebLinkAboutNC0028916_Pretreatment Audit_20090724A711. NCDENR North Carolina Department of Environment and Natural resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director July 24, 2009 Grey Walls Town of Troy 444 North Main Street Troy, North Carolina 27371 SUBJECT: Pretreatment Audit Inspection Report Town of Troy WWTP NPDES Permit No. NC0028916 Montgomery County Dear Mr. Walls: Enclosed you will find a copy of the Pretreatment Compliance Inspection Report for the inspection that was conducted on July 8, 2009 in which Monti Hassan (PERCS Unit), Paul Rawls (DWQ-FRO) and I met with you and Linda Walls (Pretreatment Coordinator for the Town of Troy). Please notice that in the Audit SUMMARY AND COMMENTS section of the report there is a recommendation and three requirements with due dates. The report indicates that Troy WWTP continues to meet the pretreatment requirements as outlined in 15A NCAC 2H .0904 (b) for Modified Pretreatment Programs. You are commended for your continued success in maintaining your program. If you have any questions, please contact me at (910) 433-3312. Sincerely, klDale Lope21.3 Environmental Specialist Enclosures: Pretreatment Audit Inspection Report EPA Water Compliance Inspection Report cc:. PERCS - Pretreatment Unit :FRO 225 Green St., Suite 714, Fayetteville, NC 28301-5043 Phone: 910-433-33001 FAX: 910-486-07071 Customer Service: 1-877-623-6748 Internet: www,ncwaterquality.org An Equal Opportunity 1 Affirmative Action Employer . Dee Freeman Secretary O'o.e . orthCarol7.na GZtuz wly United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code • NPDES yr/mo/day Inspection 1 I NI 2 1 51 31 NC0028916 111 121 09/07/08 1 17 Type Inspector Fac Type 181 GI 191 SI 201 1 I 'II I .I I I I I I I I I I 1166 • Remarks 211 I I I I I I I I I I I I I I I I 1 I I I I I 'I I I I I I I I Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ------Reserved-------- -- 671 3.0 1 69 701 31 71 11 721 N 1 731 1 1 74 75I 1 1 1 1 I 1 180 Section B: Facility Data Name and Location of Facility Inspected. (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Troy WWTP 650 Glen Rd Troy NC 27371 • Entry Time/Date 10:00 AM 09/07/08 Permit Effective Date 04/08/01 Exit Time/Date 03:00 PM 09/07/08 Permit Expiration Date 09/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Joseph Edward Shields/ORC/910-572-3661/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted E. Gray Walls,444 N Main St Troy NC 27371//910-572-7841/9105723663 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Pretreatment Section D: Summary of Findinq/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) an ature(s) of Inspector(s) ) Agency/Office/Phone and Fax Numbers Date ,,,, Dale Lopez FRO WQ//910-433-3300 Ext.712/ &j y /0? - ie - -- ,\:.) Signature of Managemen Q A Reviewer Agency/Office/Phone and Fax Numbers Date . <-44241407D siivq/c, 9f EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 3 NPDES NC0028916 I11 121 yr/mo/day 09/07/08 17 Inspection Type 18ICI (cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Please notice that in the Audit SUMMARY AND COMMENTS section of the report there is a recommendation and three requirements with due dates. The report indicates that Troy WWTP continues to meet the pretreatment requirements as outlined in 15A NCAC 2H .0904 (b) for Modified Pretreatment Programs. Please consider changing the SIU sample location. During the inspection, it appeared that the 24-hour composite sample location would more accurately monitor the SIU wastewater process wastewater if the 24-hour composite sampler were located at the first manhole instead of at the second manhole, as it is presently. The reason is that the second manhole may include both the process wastewater and the domestic wastewater, and the first manhole may not; please first investigate the facility's piping and flow schematic.Requirements: 1. The STMP is due by October 1, 2009. 2 The IWS is due by December 31, 2009. 3 Please send a copy of the adopted SUO to PERCS Unit. You are commended for your continued success in maintaining your program. If you have any questions, please contact me at (910) 433-3312. . Page # 2 NCDENR Fxvwxvwt .no Nuuv.: f+r�gt.+G•s NORTH CAROLINA DIVISION OF WATER QUALITY PRETREATMENT AUDIT REPORT Background Information (Complete prior to audit; review Program Info Database Sheet(s)] 1. Control Authority (POTW) Name: Town of Troy 2. Control Authority Representative(s): Linda Walls 3. Title(s): Pretreatment Coordinator 4. Address of POTW: Mailing 315 North Main Street City Troy, NC Zip Code 27371-3661 Phone Number (910 572-3661 Fax Number (910) 572-3663 E-Mail Iim9750(uiyahoo.com 5. Audit Date 07/08/2009 6. Last Inspection Date: 07/24/2008 Inspection Type:® PCl ❑ Audit 7. Has Program Completed All Requirements from the Previous Inspection or Program Info Sheet(s) ? • ® Yes ❑ No If No, Explain. 8. In the last year has the POTW experienced any NPDES or Sludge Permit compliance problems? ❑ Yes ® No If Yes, Explain. 9. Is POTW under an Order That Includes Pretreatment Conditions? ❑ Yes ® No Order Type and Number: Are Milestone Dates Being Met? ❑ Yes ❑ No ® NA. Parameters Covered Under Order PCS (WENDB)Coding Trans.Code Main Program Permit Number MM/DD/YY Inspec.Type Inspector • Fac. Type LU INICIO I0I2I8I9I1 I6I I07I08I09I IGI IS I I (DTIA) (TYPI) (INSP) (FACC) 10. Current Number of Significant Industrial Users (SIUS)? 1 11. Current Number of Categorical Industrial Users (CIUS)? N/A 12. Number of SIUs Not Inspected by POTW in Last Calendar Year? 0 13. Number of SIUs Not Sampled by POTW in Last Calendar Year? 0 14. Enter Higher Number of 12 or 13 0 15. Number of SIUs in SNC for Either Reporting or Limits Violations During Either of Last 2 0 Semi -Annual Periods (Total Number of SIUs in SNC) SIUS CIUS NOIN PSNC 16. Number of SIUs with No IUP, or with an Expired IUP 17. Number of SIUs in SNC for Reporting During Either of Last 2 Semi -Annual Periods 18. Number of SIUs in SNC for Limits Violations During Either of Last 2 Semi -Annual Periods 19. Number of SIUs in SNC for Both Reporting and Limits Violations During Either of Last 2 Semi -Annual Periods 0 0 0 0 NOCM MSNC 20. Number of SIUs in SNC for Self -Monitoring Requirements that were Not Inspected or Sampled 0 SNIN North Carolina Pretreatment Audit Form Pave. 1 21. PRETREATMENT PROGRAM ELEM ENTS REVIEW- Review POTW files, verify POTW has copy of each Program Element in their File, with all supporting documents and PERCS App oval Letter, and dates consistent with Program Info: Program Element Last Submittal Date In file? Last Approval Date In file Date Next Due, If Applicable Headworks Analysis (HWA) 11 Yes ❑ No 02/18/2009 /i1 Yes ❑ No 01/31/2014 Industrial Waste Survey (IWS) (11/25/2005 ❑ Yes 4 No 02/02/2005 ❑ Yes ❑ No 1 12/31/2009 Sewer Use Ordinance (SUO) 08/07/2008 i4 Yes ❑ No 10/20/2008 ►4 Yes ❑ No Enforcement Response Plan (ERP) 09/04/1992 ❑ Yes ►1 No 11/24/1992 /5 Yes ❑ No Long Term Monitoring Plan ' (LTMP/STMP) ❑ Yes ❑ No 02/18/2009 i1 Yes ❑ No 10/01/2009 Legal Authority (Sewer Use Ordinance-SUO) 22. Do you have any towns and/or areas from which you receive wastewater which are not in your annexed jurisdiction? ['Yes ® No If yes, Please list these towns and/or areas. 23. If yes to #22, Do you have current Interjurisdictional Agreements (IJAs) or other Contracts? E Yes ® No ❑ NA A copy, if not already submitted, should be sent to Division. 24. If yes to #22, Have you had any trouble working with these towns or districts? ❑ Yes ® No ❑ NA If yes, Explain. 25. Date of Last SUO Adoption by Local Council 11/03/08 26. Have you had any problems interpreting or enforcing any part of the SUO? ❑ Yes ® No If yes, Explain. Enforcement (Enforcement Response Plan-ERP) \27. Did you send a copy of the ERP to your industries? ® Yes ❑ No If no, POTW must send copy within 30 days. 28. Have you had any problems interpreting or enforcing any part of the ERP (i.e. any adjudication, improper enforcement, etc? ❑ Yes ® No If yes, Explain. 29. List Industries under a Schedule or Order and Type of Schedule or Order Resources 30. Please Rate the Following: S=Satisfactory M=Marginal U=Unsatisfacto Rating Explanation, if Unsatisfactory Personnel Available for Maintaining POTW's Pretreatment Program S ❑M ❑U Access to POTW Vehicles for Sampling, Inspections, and Emergencies '1 S ❑M ❑U Access to Operable Sampling Equipment IS,❑M ❑U Availability of Funds if Needed for Additional Sampling and/or Analysis ►Z/S ❑M ❑U Reference Materials ZS❑M❑U Staff Training (i.e. Annual and Regional Workshops, Etc.) ►Z1S ❑M ❑U Computer. Equipment (Hardware and Software) 1S ❑M ❑U North Carolina Pretreatment Audit Form PaaP 31. Does the POTW have an adequate data management system to run the pretreatment program? Yes ❑ No Explain Yes or No. Computer spread sheets 32. How does the POTW recover the cost of the Pretreatment Program from their industries? Explain. Surcharges & Laboratory costs Public Perception/ Participation 33. Are there any local issues affecting the pretreatment program (e.g.. odor, plant closing, new or proposed plants)? ❑ Yes ® No if yes, Explain. 34. Has any one from the public ever requested to review pretreatment program files'? ❑ Yes ® No if yes. Explain procedure. If no, 1-low would the request be addressed? 35. Has any industry ever requested that certain information remain confidential from the public? ❑ Yes ® No If yes, Explain procedure for determining whether information qualified for confidential status, as well as procedure for keeping files confidential from public. If no. how would the request be addressed?. As Needed 36. In addition to annual inspection, does the POTW periodically meet with industries to discuss pretreatment? ® Yes ❑ No 37. Is the public notified about changes in the SUO or Local Limits? ❑ Yes ® No 38. Were all industries in SNC published in the last notice? ❑ Yes ❑ No PermittinglIndustrial Waste Survey-IWS) 39a...I-low does the POTVII. become aware anew or changed Users? N/A Customer Base Changes 39b. Once the POTW becomes aware of new or changed Users; how does the POTW determine which industries have the reasonable potential to adversely impact the WWTP and therefore require a new permit or a permit revision? (Who is an SIU?) IWS If it seems likely 40. Does the POTW receive waste from any groundwater remediation projects (petroleum, CERCLA) or landfill leachate? ®Yes No If Yes, How many are there? Please list each site and how it is permitted, if applicable. One Uwharie Env. (permitted, but not as an SIU) 41. Does the POTW accept waste by (mark if applicable) ® Truck Dedicated Pipe ❑ NA 42. If the POTW accepts trucked waste, what controls are placed on this waste? (example. manifests required Pump & Haul designated point 43. How does the POTW allocate its loading to industries? Mark all that apply ❑ Uniform Limits ® Historical Industry Need ❑ By Surcharge ❑ Categorical Limits ❑ Other Explain Other: , samples drawn, 44. Review POTW's copies of current allocation tables for each WWTP. Are there any over allocations? ❑ Yes ® No If yes, What'parameters are over allocated? 45. If yes to #43, What is being done to address the over allocations? (short-term IUPs, HWA to be revised, pollutant study, etc.) 46. Does the POTW keep pollutant loading in reserve for future growth / safety? /Z1 Yes ❑ No If yes, what percentage of each parameter 50% 47. Has the POTW experienced any difficulty in allocation? (for example: adjudication by an industry) ❑ Yes ® No If yes, Explain. 48. How does the POTW decide on which pollutants to limit in the permits? Monitor for? (for example: were only those pollutants listed on the application limited; categorical parameters; NPDES Pollutants of Concern) Pollutants specified or that will affect the plant adversely. 49. How does the POTW decide what the monitoring frequency should be for the various pollutants in industry permits ? Explain. The level of the pollutant , and the LTMP & STMP North Carolina Pretreatment Audit Form Pace.' Permit Compliance 50. Does the POTW currently have or during the past year had any permits under adjudication? ❑ Yes ® No If yes, which industries? What was (will be) the outcome of the adjudication? 51. Demonstrate how the POTW judges compliance. This should include compliance judgment on all violations of limits, reporting requirements, and permit conditions, as well as for SNC. Monthly Surcharges 52. Does the POTW use the Division's model inspection form or equivalent? ® Yes ❑ No Um), does the POTW form include all DWQ data? ❑ Yes ❑ No 53. Were all SIUs evaluated for the need of a slug/spill control plan during their most recent inspections? ® Yes ❑ No If no, Explain. 54. What criteria are used to determine if a slug/spill control plan is needed? The potential for the SIU to affect the POTW 55. What criteria does the POTW use to determine if a submitted slug/spill control plan is adequate? Capel does not need a Slug Control Plan because there is nothing to spill at the SIU 56. How does the POTW decide where the sample point for an SIU should be located? At an effluent point where there is process waste only 57. 1-las the POTW established a procedure to ensure that representative -samples will be taken by the POTW or SIU each time? (example: correct location; proper programming of sampler; clean equipment; swirling the sample bucket uniformly) POTW: ® Yes ❑ No S:IU: ❑ Yes ❑ No If yes, Explain. 58. Who performs sample analysis for the POTW for The POTW takes all of the samples Metals Meritech Conventional Parameters Meritech Organics Meritech 59. Explain the Chain of Custody Procedure used for both in house and commercial lab samples. The POTW collects all samples for the SIU and completes the Chain of Custody forms Long/Short Term Monitoring Plan (L/STMP) and Headworks Analysis (HWA) 60a. Is L/STMP Monitoring Being Conducted at Appropriate Locations and Frequencies? ® YES ❑ NO 60b. Are Correct Detection Levels being used for all L/STMP Monitoring? ® YES ❑ NO • 60c. Is L/STMP Data Maintained in Table or Equivalent? ® YES ❑ NO Is Table Adequate? ® YES ❑ NO 60d. All LTMP effluent data reported on Discharge Monitoring Report (DMR)? ® YES ❑ NO DWQ Inspector, verify yourself! 60e. If NO to any above, list violations 60f. Should any Pollutants of Concern be Eliminated from or Added to L'STMP? ❑ YES NO If yes, which ones? Eliminated: Added: 61. Do you complete your own headworks analysis (HWA) ? ® Yes ❑ No If no, Who completes your HWA? Phone ( ) 62. Do you have plans to revise your HWA in the near future? ❑ Yes ® No If yes, What is the reason for the revision? (markall that apply) ❑Increased average flow ❑NPDES limits change ❑More LTMP data available ❑Resolve over allocation 05 year expiration ❑Other Explain. 63. In general, what is the most limiting criteria of your HWA? ❑Inhibition ❑ Pass Through ❑Sludge Quality 64. Do you see any way to increase your loading in the future (Example: obtaining more land for sludge disposal)? ❑ Yes ® No Explain. Summary 65. Do you plan any significant changes to the pretreatment program or changes to the WWTP that may affect pretreatment? No North Carolina Pretreatment Audit Form Pave d INDUSTRIAL USER PERMIT (IUP) FILE REVIEW (3 IUP FILE REVIEWS OR 1 FILE REVIEW AND 1 IU INSPECTION) 67. IUP Number 0002 68. Does File Contain Current Permit? ►Z/ Yes ❑ No effective 03/18/09 69. Permit Expiration Date January 1, 2014 70. Categorical Standard Applied (I.E. 40 CFR, Etc.) Or N/A N/A 71. Does File Contain Permit Application Completed Within One Year Prior to Permit Issue Date? ►i4 Yes ❑ No 01/02/2009 72. Does File Contain Inspection Completed Within Last Calendar Year? /ZI Yes ❑ No 12/10/2008 73. a. Does File Contain Slug/Spill Control Plan? b. If No, is One Needed? (See Inspection Form from POTW) a. ■Yes ►@No b. •Yes _@No ❑Yes❑No®N/A 74. For 40 CFR 413 and 433 TTO Certification, Does File Contain a Toxic Organic Management Plan (TOMP)? 75. a. Does File Contain Original Permit Review Letter from Division? b. All Issues Resolved? a. _Yes ■No b.®Yes❑No❑N/A 76. During Most Recent Semi -Annual Period, Did POTW Complete its Sampling as Required by IUP, including Flow? i4 Yes ❑ No 77. Does File Contain POTW Sampling Chain -Of -Custody Forms? ►1 Yes ❑ No 78. During Most Recent Semi -Annual Period, Did SIU Complete its Sampling as Required by IUP, including Flow? ®Yes❑No❑N/A 79. During Most Recent Semi -Annual Period, Did S1U submit all reports on time? ElYcs❑No❑N/A 80a. For categorical lUs with Combined Wastestream Formula (CWF), does file include process/dilution flows as Required by IUP? ❑Yes❑NOON/A 80b. For categorical IUs with Production based limits, does file include production rates and/or flows as Required by IUP? ❑Yes❑NoEIN/A 81. During Most Recent Semi -Annual Period, Did POTW Identify All Limits 15 Yes ❑ No Non -Compliance from Both POTW and SIU Sampling? 82. During Most Recent Semi -Annual Period, Did POTW Identify All Reporting Non -Compliance from S1U Sampling? E4 Yes ❑ No 83. a. Was POTW Notified by SIU (Within 24 Hours) of All Self- Monitoring Violations? b. Did Industry Resample and submit results to POTW within 30 Days? c. If applicable; did POTW resample and obtain results within 30 days of becoming aware of SIU limit violations in the POTW's sampling of SIU? a.®Yes❑No❑N/A b.®Yes❑No❑N/A c.®Yes❑No❑N/A 84. During Most Recent Semi -Annual Period, Was SIU in SNC? ❑ Yes /i4 No 85. During Most Recent Semi -Annual Period, Was Enforcement Taken as Specified in POTW's ERP? ❑Yes❑No®N/A 86. Does File Contain Penalty Assessment Notices? ❑Yes❑No®N/A 87. • Does File Contain Proof Of Penalty Collection? ❑Yes❑No®N/A 88. a. Does File Contain Any Current Enforcement Orders? b. Is SIU in Compliance with Order? a.❑Yes❑No®N/A b.❑Yes❑No®N/A 89. Did POTW Representative Have Difficulty in Obtaining Any Requested Information For You? ❑ Yes No North Carolina Pretreatment Audit Form PAOP FILE REVIEW COMMENTS: 1. The PT Coordinator. said that Capel does not need a Slug Control Plan because there is nothing to spill at the SIU. The following are industries that have local permits: • North Carolina Southern Correctional • . North Carolina Correctional • Montgomery School • Uwharrie Landfill • International Automotive Components (IAC), formerly Collins and Aikman North Carolina Pretreatment Audit Form PAOP. Fi INDUSTRY INSPECTION PCS CODING: Trans.Code Main Program Permit Number MM/DD/YY Inspec.Type Inspector Fac. Type LNti INIC10 10 1218 19 I1 16 I 1071081091 Il; I IS I I2 1 (DTIA) (TYPI) (INSP) (FACC) 1. Industry Inspected: Capel, Inc. 2. Industry Address: P.O.Box 826, 831 North Main Street, Troy, NC 27371 3. Type of Industry/Product: Textile 4. Industry Contact: David Wright Title: Dyehouse Manager Phone: (910) 572-7000 Fax: (910) 572-7040 5. Does the POTW Use the Division Model Inspection Form or Equivalent? ® Yes . ❑ No 6. Did the POTW Contact Conduct the Following Parts of the Industrial Inspection Thoroughly? Comments: A. Initial Interview ® Yes ❑ No B. Plant Tour ® Yes ❑ No C. Pretreatment Tour /ZI Yes ❑ No D. Sampling Review ® Yes ❑ No E. Exit Interview ® Yes ❑ No Industrial Inspection Comments: Please consider changing the SIU sample location; but, please first investigate the facility's piping schematic. During the inspection, it appeared that the 24-hour composite sample location would be more accurate in having only the process wastewater and not include the domestic wastewater if it were located at the first manhole instead of at the second manhole, presently the sample point. North Carolina Pretreatment Audit Form Pam... 7 FILE REVIEW COMMENTS: Audit SUMMARY AND COMMENTS: Audit Comments: The files appear to be in good order. Recommendation: 1. Please consider changing the SIU sample location. During the inspection, it appeared that the 24-hour composite sample location would more accurately monitor the SIU wastewater process wastewater if the 24-hour composite sampler were located at the first manhole instead of at the second manhole, as it is presently. The reason is that the second manhole may include both the process wastewater and the domestic wastewater, and the first manhole may not; please first investigate the facility's piping and flow schematic. Requirements: 1. The STMP is due by October 1, 2009. 2 The IWS is due by December 31, 2009 3 Please send a copy of the adopted SUO to PERCS Unit. NOD: ❑ Yes ® No NOV: ❑ Yes ® No QNCR: ❑ Yes ® No POTW Rating: Satisfactory Audit COMPLETED BY: Dale Lopez ( Marginal ❑ Unsatisfactory ❑ ti Hassan (PERCS Unit) DATE: 07/24/2009 North Carolina Pretreatment Audit Form Pnor R