Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0032202_Regional Office Historical File Pre 2018 (2)
Miehae F, Easley, Ciovernor William (r ROSS jr., Secretary North Carolina Department 0'1 Environment and Natural Resources (oleen H. Sullins, ()nectar Division of Water Quality October 1, 2007 Mr, Michael Peoples, Town Manager Town of Cramerton 115 North Main Street Cramerton, NC 28012 Subject: Permit No, WQ0032201, Stuarts Landing Wastewater Collection System Extension Gaston County, North Carolina Dear Mr. Peoples, In accordance with your application received on September 10, 2007, we are forwarding herewith Permit No, WQ0032201, dated October 1, 2007, to the Town of Cramerton for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein, This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein, Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215,6A through §143-215,6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, Mooresville Regional Office 61) East Center Ave,, Suite 301. 1\lrev Ile, NC 211.5 Phone: (' 704) 663-1699 Fox: (704) 663-6040 tritemet www,ncrmaterqualitytorg Customer Setvice,, 1-877-62.3-6748 An Equal OpportuMtylAttirmatjve AcIton Employer — 50% Recycled/10'- PostConsumer Paper hCarolina ,aturally Mr Poop Page 2 October 1, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws. Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 1,403 linear feet of 8-inch gravity sewer and the discharge of 18,720 gallons per day of collected domestic wastewater into the Town of Cramerton existing sewerage system, pursuant to the application received October 1, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Iivisions Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Town of Cramerton WWTP (NPDES No, NC0006033) prior to being discharged into the receiving stream, If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding, If you need additional informaton concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, -7 /..)1 ,for Coleen H. Suflins cc: Mooresville Regional Office, Gravity Sewer Permit File Mike Stanforth, Excel Civil & Environmental Associates, PLLC Surface Water Protection Central Files Tom Asenzo, PERCS Pr" NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERM T This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1, This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T ,0403, If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200, b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented, d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shallbe inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time, f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable, 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the Iife of the wastewater collection facilities, Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215,6A through §143-215,6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice- mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number ( -: or (1 733 0. Persons reporting any of the above occurrences shall file a spill report by completing Port I of Form -SS (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form - (or the most current Division approved form can also be completed to show that the SSO was beyond control. Per roit issued this the 1st day of October, 2007. Pern NORTH CAROLINA ENVIRONMENTAL MANAGEIENT COMSSION Coleen I-., Sullins, Director Division of Water Quality By Authority of the Environmental Eilanagernent Commission 'Number WQ0032202 Fast Track Engineering Certification Permit No, WQ0032202 October 1, 2007 Owner/WQCSMIWTP PE Michael Peoples, Town Manger Mike Staanforth Town of Cramerton Excel Civil & Environmental Associates, PLLC 115 North Main Street Po Box 6172 Cramerton, NC 28012 Gastonia, NC 28056 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form, permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shad not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION LI Partial E. Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (0 periodically, El weekly, El full time) the construction of Stuarts Landing, a Gaston County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee s responsible for tracking all partial certifications up until a final certification is received Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions . ST-TRACK APPLICATIONr GRAVIY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 Application Number: USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! (to be completed by DWQ) 1. Owner: la. Town of Cramerton Full Legal Name (company, municipality, HOA, utility, etc.) • lb, Michael Peoples, Town Manager Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) lc, The legal entity who will own this system is: 0 Individual 0 Federal x Municipality 0 State/County 0 Private Partnership 0 Corporation 0 Other (specify): 115 North main Stree Z North Carolina O lh. 704-824-4337 li Telephone Facsimile 2. Project (Facility) Information: 2a. Stuarts Landing Brief Project Name (permit will refer to this name) 3. Contact Person: 3a. Mike Stanforth, Engineer, ECEA 1j. Cramerton 28012 E- 2b, Gaston County Where Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 3b: 704-853-0800 3c. mstanforth©excelengr.com Phone Number E-mail 1. Project is x New 0 Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is x Public (skip to Item B(3)) 0 Private (go to item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) 0 Retaining Ownership (i.e. store, church, single office, etc.) or 0 Public Utility (Instruction III) Z 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) 0 Homeowner Assoc./Developer (Instruction IV) O 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) I— 3. Town of Cramerton Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. Town of Cramerton 4b. NC0006033 Name of WWTF . WWTF Permit No, 5a. Town of Cramerton 5b, !x Gravity 5c. Owner of Downstream Sewer Receiving Sewer Size :0 Force Main Permit Number of Downstream Sewer (if known) . The origin of this wastewater is (check all that apply): 0 Residential Subdivision 0 Car Wash x Apartments/Condominiums 0 Institution 0 Mobile Home Park 0 Hospital 0 School 0 Church 0 Restaurant 0 Nursing Home 0 Office 0 Other (specify): . Volume of wastewater to be allocated for this particular project: 14,025 gallons per day *Do not include previously permitted allocations 100 % Domestic/Commercial % Industrial 8. If the permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected % Other (specify): FTA 02/03 - Rev.. 3 04/05 "T-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H ,0219(1)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2f-1.0219(I)(3). 52 units with approximatelygallons per capita per day unit per day yields gallons p 0. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 ENTER TOTAL LINE LENGTH IN MILES Length (feet) 1,403 0.27 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Gravity or Force Main (use the pull down menu) Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3- plans for cross-reference) (MGD) GPM @ TDH portable generator wltelemetry; 4-wet well storage) Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable?, X Yes El No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? El Yes El No X N/A Sedimentation and Erosion Control Plan? X Yes ill No E] N/A Stormwater? E1Yes LI No X N/A 14. Does this project involve aerial lines or siphons? Check if yes: Li These lines will be considered high priority and must be checked once every six months 15. Does this project have gravity sewer lines designed at minimum slopes? X Be aware that the Division will not accept installed lines more than 10% Flatter than the minimum slope Lines installed outside this tolerance should be corrected prior to submitting the final engineering cetfication FTA 02/03 - Rev. 3 04/05 'K. APPL. CATION STAIIONS, AND FORCE MAINS PAGE 5 1, Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: X A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody: AND, X A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody, Location ID on Map If chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: 1, Michael Peoples, attest that this application for Stuart's Landing Townhomes has been reviewed by me and is accurate and complete to the best of my knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Notes In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor whic may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. la, Signing Official Signature 2, Professional Engineer's Certification: I attest that this application for Stuart's Landing Townhomes has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, 2a, Mike Stanforth Professional Engineer Name 2b. Excel Civil & Environmental Associates, PLLC Engineering Firrn 2c. PO Box 6172 Mailing Address 2d. Gastonia 2e, NC 2f, 28056 City State Zip 2g. 704-853-0800 2h, 704-853-3949 2i. mstanforth@excelengrcom Telephone Facsimile E-mail Seal, Signature & Date FTA 0210,3 - Rev. 3 04/05 Perth uber Q0032202 Program tegory Non/discharge Permit Type Gravity Sewer Extension, Purttip Stations, Pressure Sewer Extensions Primary Reviewer dee.browder Permitted Flow 18720 Central piles:APS SiPIE 1 t0/01 £ii7 Permit Tracking lip' Status Active Version 1.00 Permit Cont Project Type New Project Remit Class Ion Individual Affiliation Facility Name Stuarts Landing Coca Address Owner Owner Name Town of Cramertou at /E eats Orig Issue App Received i 0/01 /07 09/10/07 Regulated Aotivt Apartment complex randamintum; ter ctal lectfe rt ttifait NULL.. atc to Scheduled' Issuance Facility Contac A Region Central County Unknown on Owner Type Government ¢ Municipal Owner Affiliation Michael Peoples 155 N Main St Crar erton Public Notice Issue 1 /01.J07 tEvent l` dditional intorrnat'u quested Additional information received NC 28032 Effect 10/01/07 Expiration waterbody Name e Nurrrbur Current Gass cr basin Southside Constructors Inc P. 0. Box 1006 1.3e!'nnonr,. NVorrh Carolina 28012 70d-82 5-8881 a: PAY TO THE ORDER OF ED Y S'RECPAL SECURITY FEATURES FIDELTY BANK GAS TONA,ND DATE CHECK NO September 7, 2007 18790 *Four hundred eighty dollars and no cents OENR 610 E. CENTER CENTER SUITE 301. MOORESVILLE, NC 28115 SECURITYFEA1U31E-INCLUDEMICRO ARINT63Nc. •VOIDFPANTOGRAPH, ACNE NSCA4NCNERAlCALREACTANT 11'0000 L8 i 90ii' 1:0 5 3 L0 3 58 5i: L 95 1.000 2 6 4E " AMOUNT $**`*****480.00 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen SuIttns, Director Division of Water Quality October 3, 2008 Town of Cramerton 115 North Main Street Cramerton, North Carolina 28012 Attn: Michael Peoples, Town Manager SUBJECT: Stuarts Landing Permit No. WQ0032202 Wastewater Collection System Extension Final Engineering Certification Dear Perrnittee: The Division received a final engineering certification for the subject project on September 29, 2008. A full review of the certification materials may or may not be conducted. It is assumed -that receipt of this certification indicates compliance with all regulations,. design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a copy. You arereceiviing th'is'letter because the Division has you listed as the responsible party„ if this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from htfp://h2o.enr.state,nc.us/ndpu/ndpuapps.htr. l#Sewer. If you have any questions concerning this document or the completion of Form PNOCF-S cif necessary), please contact Ms, Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail,net. 1 Robert Krebs `Surface Water Protection Regional Supervisor Enclosure Mike Stanfodh, Excel Civil & En iron rental Assoc, Surface Water Protection Section Central Files icerttf ati n page as One N oI't. 7 C Pretreatment, Emergency Response and Collection Systems Unit Internet httpJdh2© enr.nc.state.us/ndpu 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Acton Employer Telephone (919) 733-5083 Fax (919)733-0059 595)) recycle f`i w% post -consumer paper rrr . . Fa_st Track Engineering Certification Permit No. WQ0032202 October 1, 2007 Owner/ VVQCSAWITP Michael Peoples, Town Manger Town of Cramerton 115 North Main Street Cramerton, NC 28012 PE Mike Staanforth Excel Civil & Environmental Associates, PLLC Po Box 6172 Gastonia, NC 28056 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater coflection system extension • Supporting design calculations (selected pumps„ system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division, ENGINEER'S CERTIFICATION El Partial tkic4.0-66.- 5-7-fr-Nlr-Darlk , as a duly registered Professionai Engineer in the State of North Carolina, having been authorized to observe (aperiodically: weekly, El full time) the construction of Stuarts Landing, a Gaston County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit, 15A NCAC 2T, the Division &Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, and other supporting materials, North Carolina Professional Engineer's seal: signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, Excel Civil & Environmental Associates, PLLC August 25, 2008 Mrs, Dee Browder NCDENF? — Division of Water Quality 610 East Center Avenue Mooresville, North Carolina 28115 Reference: Sewer Certification Statement Stuart's Landing Townhomes Cramer Mountain Road, Cramerton, NC NCDENR Permit No, WQ0032202 Excel Project No, 26097 625 Huntsman Court Gastonia, NC 28054 Telephone 704,853.0800 Facsimile 704.853.3949 i0 0 '`) 0 000m ENR NIRO Dwo-surtace Wa er Protecon Dear Mrs, Browder: Excel Civil & Environmental Associates, PLLC (Excel) has reviewed the sewer line construction at the above referenced location. Attached is the Fast Track Engineering Certification form as required. The onsite system is comprised of 1,466,7-LF (+/-) of 8" 0 SDR35 PVC sewer main, ten (10) sanitary sewer manholes and other appurtenances, Attached is a copy of the as - built drawing for your records. If you have any additional questions please do not hesitate to contact me at your convenience. Sincerely yours, EXCEL CIVIL & ENVIRONMENTAL ASSOCIATES, PLLC T. Stanf6;th, PE Principal Engineer EXCEL CIVIL & ENVIRONMENTAL ASSOCIATES, PLLC Environmental Assessment * Remechation • Civil Land Development • Geotechnical Evaluation