Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0031017_Regional Office Historical File Pre 2018 (2)
Michael E. Easley, Governor William 0, Ross Jr., Secretary 'North Carolina .Department of Environment and Natural Resources Alan W. Klimek, F.E. Director Division of Water Quality November 16, 2006 Mr. Gary Hicks, Interim Town Manager Town of Stanley 114 S. Main St Stanley, NC 28164 Subject: Permit No, WQ0031017 Town of Stanley Creekwalk Subdivision Phase II Wastewater Collection System Extension Gaston County, North Carolina Dear Mr, Hicks, In accordance with your application received on October 17, 2006, we are forwarding herewith Permit No, VVQ0031017, dated November 16, 2006, to the Town of Stanley for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application, It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordan.ce with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, Mooresville Regional Office 610 East Center Ave,, Suite 301. Mooresville, NC 2,8115 Phone: (704) 663-.1699 Fax: (704) 663-604(.1 lntemet: www.ncinwaterquality„org Customer Service: 1-877-623-6748 An Equal Opportunity/Aftirmative Actlon Employer —50% Recyclect110% Post Consumer Paper N°17;i5t.h Carolina 7aturally Mf, Hicks Page 2 November 16, 2006 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Town of Stanley for the construction and operation of approximately 1,250 linear feet of 8-inch gravity sewer and the discharge of 15,480 gallons per day of collected domestic wastewater into the Town of Stanley existing sewerage system, pursuant to the application received October 17, 2006, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Mount Holly WWTP (NPDES No, NC0021156) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714, Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, eice_146:7?", for Alan W. Klimek, P.E. cc: Mooresville Regional Office, Surface Water Protection (WWTP Permit No. NC0021156) Frank Craig, Titan Engineering Group Surface Water Protection Central Files Tom Asenzo, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1, This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403, If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B ,0200, b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i,e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f, A general observation of the entire sewer system shall be conducted at least once per year. g, Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C, ,C This permit shall not be transferable. in the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved, 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State, 6, Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C, 9, In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11 Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control, ssued this the 16th day of November, 2006. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission t Number WQ003101.7 Fast Track Engineering Certification Permit No. VVQ0031017 November 16, 2006 Town of Stanley 114 S. Main Street Stanley, NC 28164 Complete and submit this form to the permssuing regional office with the following' • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be dearly identified on the record drawings or in written summary form. Permit modifications ar e uired for an han e e u non-c m nce with this e ulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineers Certification and all required supporting documentation have been received by the Division Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION D Partial Final. as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (E1 periodically, fl weekly, rj full time) the construction of Creekwalk Subdivision Ph II, a Gaston County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit, 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Central Files: APS SWP 11 / 16/i06 Permit Number WQ0031017 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure S Extensions Primary Reviewer dee.browder Permitted Flow 15480 j=acilty Facility Name Creekwalk Subdivision Ph II Location Address er Version Permit Classification A Individual Permit Contact Affiliation Major/Minor Region Minor Mooresville County Gaston Facility Contact Affiliation Owner Name Owner Type Town of Stanley Government - Municipal Dates/Events ©rig Issue App Received 10/17/06 Regulated Activities Subdivision Wastewater collection Gutfall NULL nitiated heduled uance Owner Affiliation Michael McLaurin P© Box 279 Stanley Public Notice Issue NC 28164 Effective Expiration Requested/Received Events Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin CIVI October 4, 2006, Ms Dee Browder NCDEN.R. Division of Water 919 N. .Nlain Street .T1looresvi I le, NC 28151 Dear Ms. Browder: ENGINEERING — LAND PLANNING AND DNA .Enclosed you will find the application for the sewer extensio 1 for the Creelovalk Subdivision (phase Li) in Stanley., NC ((iaston County). The new sewer extension will consist of '1250D-8" sanitary sewer to serve the new subdivision and the sewer wilt he treated in the City of Mt. Hotly WAN/TR Enclosed two applications, flow acceptance letter from the City of Mt, Holly, NC and the $400,00 fee will be submitted with this application. Please contact this office if you have any questions or comments. Sincerely, Franklin S Tn-aig, PE 936 N. M4gIErfl4 STREET, sum- 3," CiASTONIA, N.C. 28054 PONE: (704) 865-80/2 * (704)8655794 FANS (704) 865-6861 131 South f1aun "Strec't # Pest iv)ffact E3rax 4116 1210 774- 2?-2939 * 3 - 2-2931 fax October 5, 20t 6 NCDENR Water Quality Section Pe its and Engineering Unit P.O. Box 29535 Raleigh, NC 27626-5083 Re: Flow Acceptance for the r .vity eckwalk SUk Mount Holly, N.C. Dear ,r egul torn visas .)hest The City of Mount Holly N.C. agrees accept the flow of 15,480 a l ns per day generated from the' r ckw ik Phase II project, to be treated in the City of Mount Holly wastewater treatment facility. Upon completion f construction, inspection, and testing of the sewer line, final rccord drawings and unifications will be forwarded to your office. Sinc er ly es Friday ty Director CK AEPI CATION for GRAVITY SEW S, P J P STATIONS, AND FORCE 'IAI.NS PAGE 3 tL 3a. 3b. 1. Own ta. P�ai C44��� Full Legal Name (company, 1 b. Signing 0 uerctp HC A,. y, etc,) Application Number: (to be completed by Dwq) ial Name and Tit! e (Please review 15A NCAC 2H .02i:•(b) for authorized signing officials! 1c. The legal entity who will own this system is: O Individual 0 Federal unicipality ❑ State/County 0 Private Partnersh 2. Project (Facility) Informre#io 2a. Project Name (permit will refer to this name) 3. Contact Person: Name dA ation of Someone Who 1e p 0 Corporation 0 Other (specify): City E-mail 2b. County Where Project is Located Answer Questions About this Application Phone Number 1, Project is alcreew ❑ Modification (of an existing permit) 3c. E-mail If Modification, Permit No,: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the rnodlfied information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included In the original permit. 2. Owner Public (skip to Item 8(3)) 0 Private (go to Item 2(e)) 2a. If private, applicant will be: 4a. Retaining Ownership (i.e. store, church, single office, etc.) or Leasing units (lots, townhomes, etc. - skip to Item 8(3)) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) Owner of Nam 5a. t$ Owner o Do a 6 �l tewater Treatment Fate '4114, nstream Sewer 5b The origin of this wastewater is (ch E sidential Subdivision ❑ Apartments/Condominiums ❑ Mobile Home Park ❑ School ❑ Restaurant ❑ Office 7. Volume of wast hj y (F) Treating Receiving S k all that apply): © Car Wash © Institution O Hospital ID Church © Nursing Home Other (specify): to be permitted in this project I 2b. If scald,, facilities owned by a (must choose one) ❑ Public Utility (Instruction III) ❑ Homeowner Assoc./Developer (Instruction IV) tewater From This Project 4b. +"GO 1IlSa WVVTF Permit No. 5c e Permit Number of Downstream Sewer (if known) allons per day ( O U °rb Domestic/Commercial % Industrial % Other (specify): If the permitted flow is zero, indicate why: • Interceptor Lone - Flow will be permitted is subsequent permits that connect to this line • Flow has already been allocated in Permit No. Q Rehabilitation or replacement of existing sewer with no new flow expected z Z. 0 z 0 2 0 41. Z m LICATLON for G STATIONS, AND FORCE MAINS PAGE 4 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(IX1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality,, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .9219(IX3). et . Ct44-&0),3 [2,c, 1©. Summary of Sewer Lines 1es to be Permitted (attach additional sheets if necessary) Size (inches) u ENTER TOTAL LINE LENGTH IN MILES Length (feet) 0 ry of Pump Stations to be Permitted (attach additional sheets as necessary) r4 Location ID (self chosen - as shown on Design F plans for cross-reference) (MGD) perationa4 Point GPM @ TDH Gravity or Force Main (use the pull down menu) Power Reliability Gon (1- dual line feed; 2- permanent generator wiATS; 3- portable generator w/telemetry; 4-wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mai (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? [es d No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF P PECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings o General Permit or 401 Certification? © Yes © No E /A Sedimentation and Erosion Control Plan? [fes 0 No 0 N/A Stormwater? ' es 0 No (J N/A CI) 0 CK APPLICATION for GRAWT SEWERS, PIS STATIONS, FORCE MAINS PAGE 5 1, Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: El A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody, AND, 0 A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map If csen - as shewm on Name of map for cross-reference) Waterbody lhtaterbody Stream Waterbody County River Basin Index Classification Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is providedl Applicant's Ce ation: SIINiNl Q FICIAL NAME, attest that this application for' PROJECT NAME t °°��= <. cv ttow• PI tj has been reviewed by me and is accurate and complete to the best of my knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note. In accordance with North Carolina General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10 000 as well es civil penalties up to $25, 000 per violation. Signing CfficialSignature 2. Professional Engineer's Certification: 2a, 2b. zi Date I attest that this application for (t, . RS" i� (l•rhas been reviewed by me and is accurate complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest th to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that i have reviewed this material and have judged it to be consistent with the proposed design, Note: in accordance with NC General Statutes 143-2166A and 143-215,68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation, Professional Encirreer Name Engineering Firm 2c: 11) Address 2d. (O1 City 2g 34)S6C1 G Telephone Facsirriile E-mail Seal, Signature & Date TOPOI map punted on 10/06/06 from "North Carolina,tpo' and "Untjtied.tpg" B1°06.O0O W 81°0S,000 W 810oF.000' W ©' W 81't7 r.C14 ' W 1 ii15 800" W + 884 61'°04,000" Michael F. Easley, Governor 4Vdiiar� G Ross Jr., Secretary, North Carolina Department of Env ronrnent and Natural Resources Coleen Sullins, Director Division of Water Quality August 7, 2008 Town of Stanley 114 S. Main Street Stanley, North Carolina 28164 SUBJECT: Creekwalk Subdivision Phase II Permit No. WQ0031017 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for the subject project on May 15, 2008. A full review of the certification materials may or may not be conducted. It its assumed that receipt of this certification indicates compliance with all regulations, design criteria and theEpermlt.- Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a'copy. You are receiving this letter because the Division has you listed as tt1e responsible party. If this permitted system is no longer owned by you, please complete Form PNCCF-S as this permit is not automatically transferable. Form, P'NJCCF-S can be downloaded from http /,, ' ,enr.stat .r s isindpuf,n puapps.htmi#Sever. if you have any questions concerning this document or the completion of Form PNOCF-S (if necessary), please contact Ms, Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail.net. Sineerely, L)6,/ Robert Krebs Surface Water Protection Regional Supervisor Enclosure Cc: Frank Craig, Titan Design Group Surface Water Protection Se tGc Fives (cer4st'ir ratio n page only) One NorthCa 'oima. Naturally Pretreatment, Emergency Response and Collection Systems Unit Internet httpOm2o.enrnc.state.uslndpu 1617 Mail Service Center, Raleigh, NC 27699-1.617 An Equal Opportunity Action Employer Telephone (919) 733-5083 Fax (919) 733-0059 50`% recycled/10% post -consumer paper Fast Track Engineering Certification Permit No. WQ0031017 November 16, 2006 Town of Stanley 114 S. Main Street Stanley, NC 28164 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with thispermit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial [ Final 'ts .,144 , °vv.." , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to obser� (E periodically, ❑ weekly, El -full time) the construction of Creekwalk Subdivision Ph II, a Gaston County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast --Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. CIVIL SITE — LAND PLANNING — PROJECT May 12., 2008 Ms, Dee Browder NCDENR 610 East Center Ave., Suite 301 Mooresville, NC 28115 ANAGEMENT RE: Final Certification - 8" sewer to serve Creekwaik Subdivision, Phase 2, in Stanley, NC - WQ0031017 and WQ0031017 Modification -(Gaston County) Dear Ms, Browder: Enclosed you will find final certifications and as -built drawings for the 8" sewer extensions to serve Creekwalk Subdivision, Phase 2, in Stanley, North Carolina. Construction of 1.250 "+/- of 8" and 302'+/- Of 8' sewer line have been built in accordance with the approved plans and specifications by NCDENR. and the Town of Stanley, NC. Please contact our office with any questions regarding this final certification. Thank you. 4-14v. • CIA Franklin S. Craig, PE NC DENR MR0 DWQ-Surface Water Protecton Cc: Bob Greback, Town Manager -Town of Stanley 936 N. MARIETTA STREET, SUITE 3, * GASTONIA, N.C. 28054 PHONE: (704) 865-8012 * (704) 865-5794 * FAX: (704) 865-6861