Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0031017_Regional Office Historical File Pre 2018
t Michael F. Easley, Governor WI G. Ross Jr„ Secretary North Carolina Department of Env iment and Natural Resources Alan W,Khrnek P,E. Director Division of Water Quality May 30, 2007 Mr. Gary Hicks, Interim Town Manager Town of Stanley P.O. Box 279 Stanley, North Carolina 28164 Subject Permit No, WQ0031017 Modification Town of Stanley Creekwalk Subdivision Phase II Wastewater Collection System Extension Gaston County, North Carolina Dear Mr, Hicks: In accordance with your application received on May 16, 2007, we are forwarding herewith Permit No. WQ0031017, dated May 30, 2007, to the Town of Stanley for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, shall void Permit No. WQ0031017 issued November 16, 2006, and shall be subject to the conditions and limitations as specified therein This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. The modification includes the addition of approximately 302 linear feet of 8-inch gravity sewer. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee, Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable: 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215,6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Phone: 704-663-1699 / Fax 704-663-6040 / Internet: htlp t/h2o enr state.nc:us An Eguat Opportunity/Affirmative Action Employer -- 50°aa© Recycled/10% Post Consumer Paper One NorthCarolina aturally Gary Hicks Pbge 2 May 30, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Town of Stanley for the construction and operation of approximately 302 linear feet of 8- inch gravity sewer as part of the Creekwalk Subdivision Phase II project; with no additional discharge of collected domestic wastewater into the City of Mount Flolly's existing sewerage system, pursuant to the application received May 16, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit also covers the continued construction and operation of approximately 1,250 linear feet of 8-inch gravity sewer to serve 43 three -bedroom residences as part of the Creekwalk Subdivision Phase II project, and the discharge of 15,480 gallons per day of collected domestic wastewater into the City of Mount Holly's existing sewerage system, pursuant to the application received October 17, 2006, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996,, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Mount Holly WWTP (NPDES No, NC0021156) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714 Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Basinger at (704) 663-1699. Sincerely, (1_ for Alan W, Klimek, P.E. cc: Mooresville Regional Office, Surface Water Protection (Fast Track Sewer Ext Files) Franklin Craig, P.E., Titan Design Group, inc. Surface Water Protection Central Files PERCS Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit, 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T 0403: a, The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 21_ .0200 or the surface water standards in 15A NCAC 28 .0200. b, A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week, e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h, Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 28 .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State 6, Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 27; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force ains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B _0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc,; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence, This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 12. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is a unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee, Such variance requests will be evaluated on a case by case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. Pe sued this the 30th day of May, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION fir Alan W. Klimek, RE., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0031017 Modification Fast Track Engineering Certification Permit No, W00031017 Modification May 30, 2007 Gary Hicks, Interim Town Manager Town of Stanley P 0, Box 279 Stanley, NC 28164 Franklin Craig, P.E. Titan Design Group, Inc. 936 N. Marietta Street Gastonia, NC 28054 Complete and submit this form to the permit issuing regional office with the following, One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification, and all required supporting documentation, have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION LI Partial -1 Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (0 periodically, El weekly, LJ full time) the construction of the Creekwalk Subdivision Phase U, Gaston County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NORTH CAROLINA 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, CK APPLI CATION for G s STATIONS, AND FORCE MAINS PAGE 3 0 2 0 LL 0 CL z 0 2 ILJ a. ai 1. Owner: 18. 1 b. Full Leg igning 0 ame and Tit' (Please lc. The legal entity who will ownitils system Is: Individual D Federal ligi/lunicipality 0 St ld. J1S Address State 1h. 0014)763 -1171 70 Telephone Facsimi 2. Project (Facility) Information: 2a. atitic 6:40 1- Application Number: (to be completed by DWQ) 5A NCAC 2H .02 sign ng o eiCounty Ej Private Partner hip El Corporation 0 Other (specify): Brief Project Name (permit wili refer is name) 3. Contact Person: 3a. hit,i S Name and Affiliation of Someon 3b, 00(1 865- -got?, Phone Number tP1 I e q 1j, E-mail un Proiect is Locat Can Answer Questions About this Application 3c. (1-41,-;1&aryie ro, a E-mail 1. Project is 0 New rirkodificatIon (of an existing permit) If Modification, Permit No.: iv,V, For rnodificatIons, attach a separate sheet clearly explaining the reason for the modification (I.e. adding another phase, changing line size/length, etc.). Only include the modified Information in this permit application - do not duplicate project information In B(7) and B(10-11) that has already been Included in the original permit. 2. Owner is agublic (skip to Item B(3)) 2a. If private, applicant will be: 4a. 5a. 6. El Private (go to Item 2(e)) 2b. I id, facilities owned by a (must choose gne) El Retaining Ownership (Le. store, church, single office, etc.) or El Leasing units (lots, townhornes, etc - skip to item B(3)) El Selling units (lots, townhomes, etc. - go to Item B(2b)) Owner of 4 Name El Public Utility (Instruction III) o Homeowner Assoc./Developer (Instruction IV) a ewater Treatment F ci • (VVVVIF) Treating Wastewater From This Project /7/6 /di 4141/1P 4b. NC, tr 05:6 WVVTF Permit No. Owner of stream Sewer The origin of this wastewater is esIdential Subdivision 0 Apartments/Condominiums IJ Mobile Home Park O School El Restaurant o Office 5b. 5c. Receiving Sewer Size Permit Number of (check all that apply): Ej Car Wash 0 Institution El Hospital o o Church Nursing Home O Other (specify): 7, Volume of wastewater to be permitted In this project a" gallons per day 8. If the permitted flow is zero, indicate why: O Interceptor Une Flow will be permitted is subsequent permits that connect to this line aflow has already been allocated in Permit No. tv,e2 OOP 0 /7 O Rehabilitation or replacement of existing sewer with no new flow expected Sewer (if known) Domestic/Comr % Industrial % Other (specify): z z 0 0 z 0 2 0 Z APPLICA I'IO PUMP STATIONS, AND FORCE MAINS PAGE 4 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B.(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that In 15A NCAC 2H .0219(lX 1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC '27699-1817 In accordance with 15A NCAC 2H .0219(IX3). © r 4-(Ice4, pGjr t .c/ Gam° �' ipt_e' / 1/ v 10. Sumrnary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (Inches) P ENTER TOTAL LINE LENGTH IN MILES Length (feet) 3 L ! ev3/of 7 Gravity or Force Main (use the pull down menu) t` 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) /"' Location ID (self chosen - as shown on plans for cross-reference) Design Flow Operational Point Power Reliability Option (1- dual line feed; 2- permanent generator w/ATS; 3- (MGD) GPM + TDH portable generator w/telemetry; 4-wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track. Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) end 15A NCAC 2H .0200 as applicable? [] Yes 0 No If no, please reference the pertinent minimum design criteria or regulation and Indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE II'1PITH YOUR APPLICATION 13, Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? 0 Yes El No [ I/A Sedimentation and Erosion Control Plan? { es © No 0 N/A Stormwater?fes [] No 0N/A ICATION for GRA.'Y T ' SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following, 0 co 0 0 A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody, AND, 0 A Stream Classification is not needed because the design does not depend an wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on map for cross-reference) 1 foal 4* /�+r3 Name of Waterbody Waterbody Stream Waterbody County River Basin Index Classification I/.iikf7 s.) /J5 '. Submit the 8.5" x 11" COLOR topographic map as required In Instruction Vi regardless of whether a classification is provided) Applican#"8 Cet1i�ign. 1,, SIGNING 0�1 NAME attest that this application for PROJECT NAME aet4L if Je J has been reviewed by me and is accurate end complete to the best of my knowledge. l understand that if all required parts of this application are not completed and that if ell required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signing t ifficial gnatu 2. Professlonal Encgineer's Certification: i attest that this application foible' + ' droi has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gratuity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this materiel and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application she be guilty of a Class 2 misdemeanor which may include a fine not to exceed $1 0, 000 es well as civil penalties up to $25 000 per violation. ` 2a. Professional Engineer Name 2b. ti Engineering Firm 2c. 43o /J 74,N 2d. Address 2e. /" G' 2f. MC State Zip 2h.704 5'" '' 21. rI4- J�iA e!-' Telephone Facsimile E-mail Seal, Signature & Date 2 NCD Wa P.O.g Unit oar 29535 NC 2762 ttromrsD sarsum y, NC 2 20 822-2939 •''-822.293 has •www.mtholly.us Seed° Flow p for Mo Holly,...C, S' es Friday LTtyiDireenyr TOPOI map prtnted on 05/14/07 from "North Caroffna.tpo" and "Untlfled,tpg" 81°06,000' W 131005.000' W WG584 81°04,000 W 0 4 Bl'04 Perm t Number C10031017 Permit Traleking Stip 0 f25/07' Program Category Non -discharge Status Project Type In review Major modification Permit Type Nom Version Permit Classification Gravity Sewer Exton ion, Pump Stations, Pressure Sew B Individual Extensions Primary Reviewer Permit Contact Affiliation son.basiner Permitted Flow 0 Fci Facility Name Creekwalk Subdivision Ph II Location Address Owner Owner Name Town of Stanley Dates/Events Major/ inor Minor Scheduled Or Issue App Received Draft Initiated Issuance Public Notice isa l 06 0 /16/0I7 Region Mooresville County Gaston Facility Contact Affiliation Owner Type Government - Municipal Owner Affiliation Michael PO Box 279 Stanley Regulated Activities Subdivision Wastewater oollectien Otfall NCR. L Waterbody Name MoLaurin NC d14 Effective Expiration Requested/Received Events Additional information received ;Additional information requested idea Number Current Class ubbasi CML ENGINEERING — LAND PLANNING May 14, 2007 Ms, Dee Browder NCDENR Division of Water t: 610 East Center Ave:, Suite 301 Mooresville., NC 28115 Dear Ms. Browder: MAY littar,"or, Enclosed you will find application for a sewer modification for the Creekwalk Subdivision (Phaseil) in Stanley, NC ((iaston County) The modification will consist of adding 302'-8" sanitary sewer with 0 flow The OriVinal sewer flow was permitted on November 16, 2006 (Permit no WQ0031017) and will be treated in the City of Mt. Holly WWTP. Enclosed two applications, copies of the original flow acceptance letter from the City of Nit: liolly, NC and the $400 00 application fee Please contact this office if you have any questions or comments. Sincerely, v4.4. 5- 04401-. Franklin S. Craig, PIE 6 936 N. MARIETTA STREET, SUITE 3,, * CiASTONIA, N,C 28054 PHONE: (704) 865 -8012 * (704) 865-5794 * :FAK: (704) 865 -6861 Michael F Easiey. Governor William G. Ross jr, Secretary North Carolina Department of Environment and Natural Resources Coieen Sullins, Director Division of Water Quality July 7, 2008 Town of Stanley P.0, Box 279 Stanley, North Carolina 28164 Attn: Gary Hicks, Interim Town Mgr, SUBJECT: Creekwalk Subdivision Phase II Permit No. WQ0031017 .Modification Wastewater Collection System Extension Final Engineering Certification Dear Peri ttee: The Division received a final engineering certification for the subject project on May 15, 2008. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with at regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the fife of the project. If you have not received a copy, please contact your consultant imrnedafey to obtain a copy. You are receiving this letter 'because the. Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from htto://h2o.enr.state.nc,usinaa.u±-Qpuapros.html#Sewer. f you hove any questions concerning this document or the completion of Form Pt\j0CF-S necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@ncmaitnet. 1-10-61. A.1 (Robert Krebs 1,1 Surface Water Protection Regional Supervisor Enclosure c,„„ Franklin Craig, Man Design Group Surface Water Pfoiection Section Central Files (certification pope only) if one NorthCarolina 'aurally Pretreatment, Emergency Response and Collection Systems Unit Internet http,/t2o.enr.n.c.state..usIndpu 16'17 Mail Service Center. Raleigh, NC 276.99-1617 An Equal Opportunity Action Employer Teiephone (919) 733-5.083 Fax (9191 733-0059 50% recycled(10% pcist-consumei paper Fast Track Engineering Certification Permit No, WQ0031017 Modification May 30, 2007 Gary Hicks, interim Town Manager Town of Stanley P 0 Box 279 Staniey, NC 28164 Franklin Craig, P.E. Titan Design Group, Inc, 936 N. Marietta Street Gastonia, NC 28054 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum desi criteria. This project shall not be considered complete nor allowed to operate until this Engineers Certification, and all required supporting documentation, have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION 1111 Partial LEfFinaI , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe al periodically, El weekly, [31bH time) the construction of the Creekwalk Subdivision Phase II, Gaston County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2-1; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials, North Carolina Professional Engineer's seal, signature, and date: Ave SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NORTH CAROLINA 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions,