Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0030548_Regional Office Historical File Pre 2018
/ Miehael F. Easley, Cf!kij • William G. Ross jr, Secretary' North Carol1nar,eparti1 nt of Environment Mu oral Rcsources Alan W. Kiiimk, P.E.Fiirector Division of Water Quality July 21, 2006 Barry Webb, City Manager City of Belmont 115 North Main Street Belmont, North Carolina 28012 Subject: Permit No. WQ0030548 Belmont Reserve — Phase I City of Belmont Wastewater Collection System Extension Gaston County, North Carolina Dear Mr, Webb: In accordance with your application received on July 17, 2006, we are forwarding herewith Permit No, WQ0030548, dated July 21, 2006, to the City of Belmont for the construction and operation of the subject wastewater collection system extension This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3, which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable: 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1„2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.'6A through §143-2156C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooraville R.egional Office iO Ea.st Centcr Ave,„„ Stine 301 Mooresville, NC 2811:5 1ntemet, wwwmcwaterqualityporg Customer Service', I -877-623-6741S An Equal Opportunity/Affirmative Action Employer --50?t1, Recycledi/10% Post Consumer Paper Phone: (70,4) 663-1699 Fax: (704) 663-6 40 one NtvliCarolina Mr. Barry Webb Page 2 July 21, 2006 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Belmont for the construction and operation of approximately 1,900 linear feet of 8-inch gravity sewer as part of the Belmont reserve — Phase I project, and the discharge of 23,040 gallons per day of collected domestic wastewater into the Town of Cramerton existing sewerage system, pursuant to the application received July 17, 2006, and in conformity with 15A NCAC 2H ,0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Town of Cramerton WWTP (Eagle Road WWTP NPDES No, NC0006033) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unac,ceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following .receipt of this permit. This request must be in the form of a written petition, conforming to Chapter150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714, Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Marcia Allocco at (704) 663-1699. cc: Mooresville Regional Office, Surface Water Protec Franklin Craig, Titan Engineering Group Inc, Surface Water Protection Central Files Marie Dokievic, PERCS Sincerely, for Alan W. Klimek, P.E. TP Permit No, NC0006033) NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTON SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times,. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC .2E_ .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected al least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. fL Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 4, ThisjermtsiaH not be transferabe. n the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State, 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided an the form, A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200, the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215,6C. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities, 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500, 1 Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following; a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable. of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer ine resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed inforrriin is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management t telephone number (800) 3 -t 3 8 or (919) 33-3333. Persons reporting any of the above occurrences shall file a spill report by completing Parti of orm - (or the most current Division ision approved form), within five days following it g first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that, the problem does not recur, Part II of Form - (oar the most current Division an approved fnrrn) can also be completed to show that the Sate was beyond control:. Per issued this the . 1st day of July, 2006. NORTH R LINA ENVIRONMENTAL l'ANAGEM NT COMl llSSION le - Alan ‘Al. Klimek, ..n k , Director' ctor Division of Water Quality By Authority of the Environmental Per if Nurb0030548 dr Comm on Fast Track EngineeringEngineerinq Certification City of Belmont Permit No. WQ003054 July 21, 2006 Complete and submit this form to the permit issuing regional office with the followir3g One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Perrn modifications are required for any changes resulting in non-compliance withths errmt regulations or minimum design criteria, This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a mariner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION -1 Partial [11 Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (11 periodically, El weekly, Ej full time) the construction of Belmont Reserve — Phase I, a Gaston County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H ,0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. CK APPLICATION for GRAVITY S PTJMP STATIONS, AND FORCE MAINS PAGE 3 0 2 0 LLz z 0 —1 z Ix 0 z oi 1 Owner: la, 111 /lief Vi'-E 5(1144-(014 Full Legal Nat e (company, municipality, Hai\ utility, etc.) a kJ Signing Official ame and Title (Please rwiew ISA NC 2H .0206(b) for authorized signing officials') lc The legal entity who will own this systern is. 0 Individual EI Federal iuncipaUty 0 State/County 0 Private Partnership 0 Corporation 0 Other (specify): le. Application Plumber: (to be competed by DWQ) ) 1d. If6 N • M4-evi 56( ect Street Address 1 f N W4/1 Telephone 2. Project (Facility) Information: 2a, Brief Project 3. Contact Pers 3a, 3b, p n: CV-41 othis n 1j, 2 Zip Code E-mail CourttyWhoro Proj e and Affiliation of Someone Wh n Answer Questions About this Application Phone Number 5 gio(1.• 3c. eci reti4-14, E- Is Ldted 1. Project is INew 0 Modification (of an existing permit) If Modification, Permit No,: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le, adding another phase, changing line size/)ength, etc.). Only include the modified information In this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2, Owner is Rt'ublic (skip to Item B(3)) 0 Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) 3. 4a, 5a, 0 Retaining Ownership (i.e. store, church, single office, etc.) or ljj Leasing units (lots, townhomes, etc. - skip to Item B(3)) El Selling units (lots, townhomes, etc. go to Item 8(2b)) Owner Na 0 Owner of Downs 0 Public Utility (Instruction III) El Homeowner Assoc./Developer (Instruction IV) LhAfe-n9 - -roam a er Treatment Facility (AdWTF) Treating WastewaterRom This Project 4b. A/6 000 3 3 The origin of this wastewater is Residential Subdivision El Apartments/Condominiums El Mobile Home Park El School El Restaurant ED Office 5b, 9) 41 5c. VVVVTF Permit No. Receiving Sewer Size Permit Number of Downstream Sewer (if known) (check all that apply): 0 Car Wash 0 Institution El Hospital 0 Church 0 Nursing Home 0 Other (specify): 7, Volumeofwastewaterto be permitted in this project ZS04:0 g n p day 100 % Domestic/Commercial % Industrial % Other (specify): . If the permitted flow Is zero, indicate why: 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line 0 Flow has already been allocated in Pernik No. 0 Rehabilitation or replacement of existing sewer with no new flow expected CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, FORCE MAINS PAGE 4 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(l)(3). 4-ha,..e x 3019 ack40 fet0,t3 10 Summary of 'Sewer Lines to be Perritted (attach additional sheets if necessary) Size (inches) z 1— z Q U ENTER TOTAL LINE LENGTH IN MILES 'j5'4 Length (feet) V idot 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary Location ID Et (self chosen - as shown on Design Flow 0 plans for cross-reference) (MGD) LL z Operational Point Gravity or Force Main (use the pull down menu) 4W / Power Reliability Option (1- duel line feed; 2- permanent generator wiATS; 3- GPM TDH portable generator witelenmetry; 4-wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force m s (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? Mai1Yes © No If no, please reference the pertinent minimum design criteria or regulation and Indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? El Yes 0 No NIA Sedimentation and Erosion Control Plan? 1s 0 No © NiA Stormwater? lkr<s 0 No 0 N/A ''RACK APPLICATION for GEA ITY SEWERS, PL17!M P STATIONS, FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 021'03 (FAST -TRACK SEWER SYSTEMS)°` to collect and record the stream classification data below (attach additional sheets as necessary). This document Is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: Q A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope Qwaterbody; AND, (� © A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. i) 0 Location. ID on Map (self chosen - as shown on map for cross-reference) 1 a. Name of Waterbody 'fhb! l County Waterbody Stream Waterbody asin index Classification Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: J, S NN/NOFFICIA NAME, attest that this application for PROJECT NAME t3etan►nt- Ret5e~ has been reviewed by me and is accurate and complete to the best of my knowledge. i understand that if all required parts of this application are not completed end that if all required supporting documentation and attachments are not included, this application package is subject to being returned es incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $1 0, 000 as well as civil penalties up to $25, viol ion. Signing s'`l `:;gnat 2, Professional Engine is Certification: 2 2b. 2c. 2d, ll ate U6 ! attest that this application for t44- vG has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this materiel end have judged it to be consistent with the proposed design. Note: in accordance with NC General Statutes 143-215, 6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Pro Engineering Firm lam+ 1 W. Address 645444 Telephone Facsirnile L-me ¢ Seal, Signature & Date 15:07 704825''304.9 im RAMERTON PAGE Subje of W Phan vF : tans frorrt-To r of Cratnerton WWTP„ for 23 aiic sJday DES ermit No. 0006033, t serve The Belmont Reserve Subdivision. is its receipt of your request e+r:wustewatz° flow aicetan average tinily flow to the Town of Ctarnerton WWr ese arnowns the Town of Cramerton can treat the 2304 information or if we can be of ins this is.soc 155 North Main Street Cratnerton, NC 28032 704 / 824-433r' TOPOI map pnnted on 04/24/06 from "North Carollna,tpo" and "Untitled tpg" 6104,000W B1003,000' W WGS84 81'02,000' W 3516.000N 35°15 000' z 35°13,000' N 8104.000' W 81°03,000' W WGS84 81°02.000' W MU. Przated fie= TOPOI 02001 Natizzel Ovographk HoIdangs (www repo cam) 3516,000' N 1 4 000' N CIVIL * ENVIRONMENTAL GEOTECHNICAL — LAND PLANNING r�ls e Thee Browder NCD.ENR Main Street Mooresville, NC 28115 RE: Sewer Permit - 8'" sewer exte Belmont, NC. Dear B3roww=der: Si v JUL Reserve Suhdivision Phase It Enclosed you will. find applications 1' r the 8" sewer extensions to serve The Belmont Reserve Subdivision Phase 1 in Belmont, North Carolina, Enclosed are the 2 applications, $400,00 fee, and flow acceptance letter from the Town ofCranrerton, NC. Please contact our office with any questions regarding this application, Thank you, vlr' Franklin S, (;"r 201 WEST SECOND At 1' (¢ENE: (704) 865 -801. , C ASTC NIA, rALC, .28052 i5-5794 FAX: (704) 865-6861 rrr trelrrxt Ctcr ry Non -discharge 1 rrrsit Type Gravity Sewer Extensions xtension Punta atlans,& Pressor Sewer tr1laryReviewer rnarc llocca Pen itted Flow 23040 Fa ility Facility Names 3elmant Reserve ®Ph se Lo ion Address arttediE Ong Issue t tited Ac i fibt 'or} Ostia! App tr civr rt 0721'7/06 Drat' ctr 1 11 1n Centr+l Files AP C P 07,120/06 Pert t Tracking lip trlktl Project Type In review New Project Version Permit Gins, Individual Permit Contact t9 I1 r1t x Nu er Region Moore County Gaston clhtyt C art r tt Affiliation Owner Type GayerCtt11ef1i M Owner Affiliation Barry PO Box 431 Belmont 8a la pal ebb ton NC 28012 tft.ctiv Expiration o