HomeMy WebLinkAboutWQ0030387_Regional Office Historical File Pre 2018Michael E. Easley, Governor William 6. Ross Jr„ Secretary North Carolina Department of Environment and Natural Resources Alan W4 Klimek, P.E.. Director Division. of Water Quality June 14, 2006 Mr, Michael McLaurin, Interim Town Manager Town of Stanley PO Box 279 Stanley, NC 20164 Subject: Permit No, WQ0030387 Kelly's Landing Development Town of Stanley Wastewater Collection System Extension Gaston County, North Carolina Dear Mr, McLaurin: In accordance with your application received on May 19, 2006, we are forwarding herewith Permit No, WQ0030387, dated June 14, 2006, to the Town of Stanley for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of the permit and is therefore incorporated therein by reference, Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based an acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules, Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave,, Suite 301 Mooresville, NC 28.115 Internet www,ncwaterqualIty,org Customer Service, I -877-623.-6.748 An Equal Opportunity/Affirmatve Action Employer-50% Recycledi10% Post Consumer. Paper Phone; (704) 663-1699 En; (704) 663-6040 One NorthCa ;WM/ IPPIIFF In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Mr McLaunn Page 2 June 14„ 2006 Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Town of Stanley for the construction and operation of approximately 3,024 linear feet of 8-inch force main as part of the Kelly's Landing Development sewer project, and the discharge of 40,680 gallons per day of collected domestic wastewater into the City of Mt. Holly's existing sewerage system, pursuant to the application received May 19, 2006, and in conformity with 15A NCAC 2H 0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Mt. Holly VVVVTP (NPDES No. NC0021156) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, %), '?- for Alan W. Klimek, RE. cc: Mooresville Regional Office, Surface Water Protection (WVVTP Permit No. NC0021156) Miles Wright, Wright 8, Associates Surface Water Protection Central Files Marie Doklovic, PERCS e. f. 9, h. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of ssuance until rescinded and shall be subject to the following specified conditions and limitations: This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000., as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H ,0227: a, The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented, d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. High -priority sewer lines shall be inspected at least once per every six-month period of time. A general observation of the entire sewer system shall be conducted at least once per year. Inspection and maintenance records shall be maintained for a period of at least three years. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit 15A NCAC 2H ,0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mad messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 88-8 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part 1 of Form C - O (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur, Part Il of Form CS -SS (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the loth day of June„ 2005. NORTH CAROLINA ENVIRONMENTAL ANAGE f r$ for Alan W. kl0fiek, RE, E., Director Division of Water Quality By Authority of the Environmental Management Comm] Ifiv QOO ( ion Fast Track Engineering Certification Town of Stanley Permit No. WQ0030387 June 14, 2006 Complete and submit this form to the permit issuing regional office with the following, One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modJficatiojrereuiredfor any char ges resultin in non-com�liance with this perrnit, re ulations or This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial LI Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (0 periodically, 0 weekly, 0 full time) the construction of the Kelly's Landing Development, Gaston County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H 0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, and other supporting materials. North Carolina Professional Engineer's seal, signature, and date' SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, FAST -TRACK APP ICA 'ION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE NIAINS PAGE 3 0 0 z (.) 0- a. USE THE TAD KEY To MOVE FROM FIELD TO FtEELU 1, Owner 1 a. 'aft Full Legal Name (company, municipality', HOA, utility, etc.) lb., ITV' ck /z r)(\c,. App ication Number: (to be completed by DWQ) Signing Official Name and Title (Please review 15A NCAC 2(1 ,0206(b) for authOnzed signing officials!) lc. The legal entity who will own this system is: 0 Individual, 0 Federal Ei Municipality Ej State/County rj Private Partnership 0 Corporation 0 Other (specify): 1 O, p„ tS le, <)4- ey Mailing Address City if. Noll11\.. 1g, State Zip Code 1 h 70-1 —L17V i Us4 Zij 11,-je 41. cot" ell', Of" - Telephone Facsimile E-mail 2. Project (Facility) information: 2a. 'LQr De 2b. Brief Project Name (perm *I refer to lhis name) 3. Contact Person: 3a. nik, L.), " a " County Where Project is Located Name and Affiliation of S mec e Who Can Answer Questions About this Application 3bi 6 Le) £/ Z?o 3c, /11iie.; Phone Number E-mail 1. Project is New Ej fVlodification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is ryi Public (skip to Item B(3)) 0 Private (go to Item 2(a)) 2a. If private, applicant will be 2b. If sold, facilities owned by a (must choose one) 0 Retaining Ownership (i.e. store, church, single office, etc) or Ej Public Utility (Instruction III) 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) 0 Homeowner Assoc./Developer fin tr bon IV) 0 0 Selling units (lots, townhomes, etc, - go to Item B(2)) C4 rc ,42/' &V / Owner ofli/Vastewater Treatment taciiity (VVVVTF) Treating Wastewater From This Project ..„,,,. ii44/ NI /Xi 4biF N,{C.- 00Z1150 .„„ . Name ofWITF 'VVVVTF Permit No. 5a. --ri),J,. . ,,, 5b. e.J° Gravity i?,o. Z Owner of Downstream Sewer Receiving Sewer Size 0 Force Main ' Permit Number of Downstream Sewer (if known), ........ _ 6, The origin of this wastewater is (check all that app(y), E E3 Residential Subdivision IX 0 Apartm,ents/Condominiums LLI 0 Mobile Home Park CL 0 School Ca El Restaurant 0 Office Ej Car Wash 0 Institution 0 Hospital Church ID Nursing Home 0 Other (specify): % Domestic/Commercial °A Industrial % Other (specify): 7. Volume of wastewater to be allocated for this particular proiect.liacei0 gallons per day *Do not include previously permitted allocations 8. If the permitted low is zero, indicate why. O Interceptor Line - Flow will be permitted in subsequent permits that connect to this ne Ej Flow has already been allocated in Permit No. O Rehabilitation or replacement of existing sewer with no new low expected FTA 02/03 - Rev. 3 04105 FAST -I APPLICA'I°I+C N for GRAVIT7' SEWERS, PI1MP STATIONS, AND FORCE l "IAINS PACE 4 Provide the wastewater flow calculations used In dete wining the permitted flow in accordance with 15A NCAC 2H ,0219(t) for Item B(7) or the design flow for line, or pump station sizing if zero go w in the space below„ Values other than that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data In accordance with 15A NCAC 2H .0219(i0(3), i !2 10 Summary of Sewer Lines to be Permitted (attach addittonal sheets if necessary) Size (inches) Length (feet) z H ENTER TOTAL LINE LENGTH IN MILES V11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) z 0 1— Q 0 LL Z Location ID (self chosen - as shown on plans for cross-reference) Design Flow Operational Point (MGD) GPM t TDH Gravity or Force Main (use the pull down menu) Power Reliability Option (1- dual line feed; 2- permanent generator w1ATS; 3- portable generator wltelemetry; 4-wet well storage) 12, Does the sewer system comply wsth the Minimum Des gn Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? Mt Yes D No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION Yes [] No Yes 0 No Stormwater? 0 'Yes [) No 14. Does this project involve aerial Nines or sophons? Check if yes: 0 These lines -will be considered hiah anohty and must be checked once every sir months 15, Does this project have gravity sewer lines designed at minimum slopes Be aware That the Division will not accept installed lines more than 10% flatter than the mini corrected pnor to submitting the final engineering certification.. Have the following permits/certifications been submitted for approval Wetland/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erasion Control Plan? pe. Lin NiA 0 N/A Ej N/A a d outside this toferar ce shoo FTA 02/03 - Rev. 3 04/05 FAST -TRACK .:ATION for VERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 „ . 0 F— 1., Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following, El] A Stream Classification is not needed because ail parts of the project are at least 100 feet away from any down slope waterbody: AND 1:1 A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody, Location ID on Map (self chosen - as shown on map for cross-reference) Name of Waterbody County Waterbody Stream Waterbody River Basin Index Classification osvNt 1;3 . 454bn 11-1k4- 4 t)IV 5, Stois boy c crek Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1, Applicant's Certification: la. /, SIGNING OFFICIAL NAME, attest that this application for PROJECT NAME has been reviewed by me and is accurate and complete to the best of my knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete„ Note: In accordance with North Carolina Genera/ Statutes143-215.64 and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil pen /ties up to $25.000 per violation. Signing Official Signature 2, Professional Engineer's Certification: 0 6 2a 2b 2c 2d 2a I attest that this application for • has been reviewed by rne and is accurate, complete and consistent with the information in the engineer plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the ,proposed design has been prepared in accordance with the applicable regulations. Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track ,Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and sea/ signifies that I have reviewed this material and have judged it to be consistent with the proposed design:(Vote: In accordance with NC General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as web as civil penalties up to $25,000 per violation, 5 , Professional Engineer Name Engineerfrfg Firm f t Mailing Address Ale 1‘)J1V1 City -2Z,K 2h e 7.6 , Telephone Facsimile 2e. 4/C: 2f, State Zip 2i, 71/04.5 kPS.0,5 E-mail 1 Seal Signature& Date ETA 02103 - Rev. 3 04/05 !Image Courtesy a`the USGS a 4ue 1 ot 1 Back c)'re, r :w km NE of North Carol °5Km Y of mL Terms of Use Privacy Statement http:!/ternaserver.m.kcrasoft.com/Printulluage.aspx?T=2 S=i &Z==1.7&X 17" 4887&W=3... 4/ 0/ 006 CITY ref MQII l+iT` HOLLY Robert Whitt, Mayor Phyllis Harris, Mayor ProTem Jerry Bishop, Councilrnan Jim Hope, Councilman Pat Hubbard, Councilwoman Frank McLean, Councilman David A, Moore, Councilman David Kraus, City Manager 'th Main Street • Post Office Box 406 • Mount Flour, North Carolina 28120 • 704- 327-i931 May 17, 2006 Town of Stanley Michael Mc Laurin, City Manager 11.4 South Main. Street Stanley, North Carolina 28164 RE: Kelly Landing Dear Michael; 704 822 2'I You have requested 40,600 gallons of capacity for water and sewer for the proposed Kelly Landing subdivision. Per our 1993 agreement, the Town of Stanley has reserved the capacity for up to 1,5 millions gallons of water per day and 500,000 gpd of treatment capacity. Currently, Stanley consumes approximately 600,000 gallons of water per day. On a monthly basis, Stanly has reserved the waste treatment capacity of 6,000,000 and has had a peak usage of 5,822,000. While this will allow for the development of Kelly's Landing, Stanley should begin to look at its wastewater usage for future developments. Additionally, the Kelly's Landing application for a permit will require our WWTF permit number, which is NC0021156 and NC0021156-104 for the downstream discharge. if you have any additional questions, please contact me directly. Thank you. vv,rntholly.us Permit Number Central Files: APS SWP 06113106 0030387 Permit Tracking Slip Prograrn Category Status Project Type Non -discharge In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 40680 Facility Facility Name Kelly's Landing Development Location Address Ovine Major/Minor Region Minor Mooresville County Gaston Facility Contact Affiliation Owner Name Owner Type Town of Stanley Government - Municipal Owner Affiliation Michael McLaurin PG Box 279 Stanley Events NC 28164 Orig Issue App Received Draft Initiated 05/19/06 Scheduled Issuance Public Notice Issue Effective Expiration Regulated Activities Reame$ted/Received Events Subdivision Additional 'information requested Wastewater collection Additional information received Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin Michael F. Easley Governor William G Ross Jr . Secretary North Carolina Department of Environment and Natural Resources Coleen Sullins., DIrector Division of Water Quality January 22, 2008 Mike McLaurin.. Int Town Manager Town of Stanley 114 S. Main Street Stanley, North Carolina 28164 SUBJECT: Kelly's Landing Development Permit No. WQ0030387 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for the subject project on December 3, 2007. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a copy. You are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from http;//h2oenr.statenc.usindpLIThdouapps.html#Sewer. If you have any questions concerning this document or the completion of Form PNOCF-S (if necessary)„ please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.trowder@inamaitnet. Sincerely, e Robert Krebs Surface Water Protection Regional Supervisor Enclosure Ca James Magennis Surface Water Protection Section Central Files (certification page only) Please forward to Engineer One North Carohn atitrailij Pretreatment, Emergency Response and Collection Systems Unt Internet httptah2o enr.no..state usindpu 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer Telephone (919) 733-5083 Fax (919) 733-0059 50% recycled/10% post -consumer paper t Track En neerirm celrti a i0t! Town of Stanley Permit No, WQ0030387 June 14, 2OC16 NR MRO DWQ Sus face ater Prot ton Complete and submit this form to the permit issuing regional office with the following_ One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design ulations (selected pumps, system curve, operating point, available storage if portable generators) or stor age greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written su modifications are re aired for n h n s re uI in in non om li 'nee wi h his er*xp minimum design c Perrmit This project shall not be considered complete nor allowed to operate until this Enrtifi ation and all required supporting documentation have been received by the Division. Therefere, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division, ENGINEER'S CERTIFICATION DI Partial (,Final f, „s , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe perrodically, [] weekly„, 0 full time) the construction of the Kelly's Landing Development, Gaston County project for the Permittee hereby state that, to the best of my abilities, tiue.care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200 the Division of Water Quality's{Division) Gravity Sewer Minimum DesignCriteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria:for the Fast -Track, Permitting of Pump Stations and Force Mains adapted June 1 2000 as applicable; and other supporting materials. North Carolina Professional Engi seal, lig ature; and date: The Permittee is responsible for trackin wastewater flow made tributary to the w Engineer's Certification shall be conside .enfdreemerpt actions. SEND THIS FORM & 'SUPPORTING OOCt1MENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESViLLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 ations up until a final certification is revived. Any lection system extension prior to completion of this of the permit and shall subject the Permittee appropriate