Loading...
HomeMy WebLinkAbout20210644 Ver 1_NC 208 Wet Pipe Recommendations-REVISED 5-14-21_20210602UT #LAT LONG PIPE STA STATUS CURRENT SIZE EXISTING LENGTH LENGTH TO REPLACE (LFT)LIVE WATER EXTENSION LENGTH (LFT)NOTES 1 35.939978°-82.742829°18+86 Failing- Replace 18"CMP 35 40 Yes Add 5 Replace with 24" HDPE - Extend on Inlet 2 35.940132°-82.742892°19+81 Failing - Replace 24"CMP 30 37 Yes Add 7 Recommend replace with 30" HDPE- Extend on Inlet 3 35.945294 -82.744708 42+75 Good 30"HDPE Yes 4 35.946647°-82.744233°47+87 Failing - Replace 24"CMP 35 40 Yes Add 5 Replace with 24" HDPE - Extend 2.5' on Inlet and 2.5' on Outlet 5 35.947560°-82.744327°50+86 Failing - Replace 18" CMP 35 35 Yes 0 Replace with 24" HDPE 6 35.948221°-82.744935°53+86 Functioning but under sized 2-30"CMP 35 45 Yes Add 10 Hydro recommended replacing with 2-54" w/HW, buried one foot Extend 5' each way 7 35.948503 -82.745396 55+55 Deteriorating - Line 18"CMP 40 Yes Wash out & line 8 35.948939°-82.746116°59+26 Failing - Replace 30"CMP 35 40 Yes Add 5 Hydro recommended replacing with 54" w/HW, buried one foot; Extend inlet 5' and add driveway pipe near inlet 9 35.955500°-82.748704°92+87 Good 18"HDPE Yes 10 35.955821°-82.749000°94+37 Good LARGE ARCH PIPE Yes 11 35.960867°-82.754779°120+30 Good 24"CMP Yes 12 35.965838°-82.753706°140+66 Failing - Replace 24"CMP 35 40 Yes Add 5 Hydro recommended replacing with 30" - Extend 2.5' each way 13 35.966222°-82.753394°142+37 Failing - Replace 24"CMP 25 35 Yes Add 10 Replace with 24" HDPE -Adjust inlet and extend outlet 14 35.969336°-82.752159°154+75 Good 3 - Barrel Box Culvert Yes 15 35.971279°-82.752748°162+32 Good 24" HDPE Yes 16 35.977202°-82.755050°186+50 Good Box Culvert Yes 17 35.978817°-82.756930°196+50 Good Box Culvert Yes 18 35.980909°-82.758777°205+80 Good 60" HDPE Yes Replaced in 2019 19 35.982452°-82.760110°212+79 Good 18"HDPE Yes 20 35.983995°-82.763788°226+52 Deteriorating - Line 18"CMP 35 35 Yes Wash out & line 21 35.984418°-82.764412°229+28 Failing - Replace 30"CMP 30 30 Yes 0 Replace with 36" HDPE - Build Headwall and Tailwall 22 35.986003°-82.766060°236+94 Failing - Replace 18"CMP 30 30 Yes 0 Hydro recommended replacing with 2-24" HDPE - Build Headwall and Tailwall NC 208 CROSSPIPES 23 35.987133°-82.768088°244+22 Good 60"CMP Yes 24 35.987555°-82.778207°277+15 Failing - Replace 18"CMP 35 35 Yes 0 Replace with 18"HDPE 25 35.987699°-82.780726°284+32 Good - But inlet damaged 24"CMP 35 35 Yes 0 Replace with 24" HDPE 26 35.987595°-82.782180°288+69 Good 24"HDPE Yes 47 feet of extension Pipes extended in live water