HomeMy WebLinkAboutSW6210506_Supplement-EZ Form_20210528SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
1PROJECT INFORMATION
1 1 lProiectName
2 Project Area (ac)
3 Coastal Wetland Area (ac)
4 Surface Water Area (ac)
5 Is this project High or Low Density?
6 Does this project use an off -site SCM?
Cotswold
19.1
0
2.45
No
COMPLIANCE WITH 02H .1003(4) E=E
7
Width of vegetated setbacks provided (feet)
n/a
8
Will the vegetated setback remain vegetated?
1 9
IlfBUA is proposed in the setback, does it meet NCAC 02H.1003(4)(c-d)?
N/A
1 10
1 Is streambank stabilization proposed on this project?
...... . ............
NUMBER AND TYPE OF SCMs: I M
11
Infiltration ystem
12
Bioretention Cell
13
Wet Pond
2
14
Stormwater Wetland
15
Permeable Pavement
16
Sand Filte
17
Rainwater Harvesting (RWH)
18
Green Roof
19
Level Spreader -Filter Strip (LS-FS)
20
Disconnected Impervious Surface (DIS)
21
Treatment Swale
22
Dry Pond
23
StormFilte
24
Silva Cell
I
1 25
113ayfilter
IFilterra
1 26
I
I FORMS LOADED
IDESIGNER CERTIFICATION
27 Name and Title:
28 rganization:
Scott Brown, PE - Vice President
4D Site Solutions, Inc.
29
Street address:
409 Chicago Drive, Suite 112
30
City, State, Zip:
Fayetteville, NC 28306
1 31
JPhone number(s):
910-426-6777
1 32
JEmail:
sbrown(a)4dsitesolutions.com
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that
the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans,
specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here.
Seal
Signature of Designer
Date
WETPOND
[--fl Drainage area number
1 21Minimum required treal
IGENERAL MDC FROM 02H .1050
3
Is the SCM sized to treat the SW from all surfaces at build -out?
Yes
Yes
4
Is the SCM located away from contaminated soils?
Yes
Yes
5
What are the side slopes of the SCM (H:V)?
3:1
3:1
6
Does the SCM have retaining walls, gabion walls or other
engineered side slopes?
No
Yes
7
Are the inlets, outlets, and receiving stream protected from erosion
1 (11 0-yea r storm)?
Yes
Yes
81's
there an overflow or bypass for inflow volume in excess of the
design volume?
Yes
Yes
91What
is the method for clewatering the SCM for maintenance?
Pump (preferred)
Pump (preferred)
10
If applicable , will the SCM be cleaned out after construction?
Yes
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
N/A
N/A
14
Is there an O&M Agreement that complies with General MDC (111)?
I
Yes
Yes
151
Is there an O&M Plan that complies with General MDC (12)?
Yes
Yes
161
Does the SCM follow the device specific MDC?
Yes
Yes
17JWas
the SCM designed by an NC licensed professional?
Yes
Yes
WET POND
MDC FROM 02H.1053 L
18
Sizing method used
SA/DA
SA/DA
19
Has a stage/storage table been provided in the calculations?
Yes
Yes
20
Elevation of the excavated main pool depth (bottom of sediment
removal) (fmsl)
284.50
284.00
21
Elevation of the main pool bottom (top of sediment removal) (fmsl)
285.50
285.00
221
Elevation of the bottom of the vegetated shelf (fmsl)
289.00
289.00
23
Elevation of the permanent pool (fmsl)
289.50
289.50
24
Elevation of the top of the vegetated shelf (fmsl)
290.00
290.00
25
Elevation of the temporary pool (fmsl)
292.09
291.09
26
Surface area of the main permanent pool (square feet)
8648
2186
27
Volume of the main permanent pool (cubic feet)
24933 cf
5140 cf
28
Average depth of the main pool (feet)
3.20 ft
3.21 ft
291Average
depth equation used
Equation 3
Equation 3
30
If using equation 3, main pool perimeter (feet)
407.8 ft
183.8 ft
31
If using equation 3, width of submerged veg. shelf (feet)
3.0 ft
3.0 ft
32
Volume of the forebay (cubic feet)
4407 cf
869 cf
33
Is this 15-20% of the volume in the main pool?
Yes
Yes
34
Clean -out depth for forebay (inches)
12 in
12 in
35
Design volume of SCM (cu ft)
31705 cf
5356 cf
361
Is the outlet an orifice or a weir?
Orifice
Orifice
37
If orifice, orifice diameter (inches)
2.75 in
1.25 in
38
If weir, weir height (inches)
39
If weir, weir length (inches)
40
Drawdown time for the temporary pool (days)
2
2.1
41
Are the inlet(s) and outlet located in a manner that avoids short-
circuiting?
Yes
Yes
421Are
berms or baffles provided to improve the flow path?
No
No
43
Depth of forebay at entrance (inches)
54 in
54 in
44
Depth of forebay at exit (inches)
48 in
48 in
45
Does water flow out of the forebay in a non -erosive manner?
Yes
Yes
46
Width of the vegetated shelf (feet)
6 ft
6 ft
47
Slope of vegetated shelf (H:V)
6:1
6:1
48
Does the orifice drawdown from below the top surface of the
I pe rma ne nt poo I?
Yes
Yes
49
Does the pond minimize impacts to the receiving channel from the 1-
lyr, 24-hr storm?
Yes
Yes
50
Are fountains proposed? (If Y, please provide documentation that
I MDC(9) is met.)
No
No
51
1 Is a trash rack or other device provided to protect the outlet system?
Yes
Yes
52
Are the dam and embankment planted in non -clumping turf grass?
Yes
Yes
53
Species of turf that will be used on the dam and embankment
Centipede
Centipede
54
Has a plantinq plan been provided for the vegetated shelf?
Yes
Yes
,ADDITIONAL
INFORMATION
55
Please use this space to provide any additional information about
ithe wet pond(s):
Wet Pond 1 4:07 PM 5/28/2021
DRAINAGE AREAS
1
Is this a high density project?
Yes
2
If so, number of drainage areas/SCMs
2
3
Does this oroiect h.". 1-.' '4-ih, areas?
No
4
If so. number of 1--, 4-ify drainage areas
0
5
Is all/part of this project subject to previous rule
versions?
No
I FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
1
2
4
Type of SCM
Wet Pond
Wet Pond
5
Total drainage area (sq ft)
591,964
97,762
6
Onsite drainage area (sq ft)
544,255
97,762
7
Offsite drainage area (sq ft)
47,709
8
Total BUA in project (sq ft)
291016 sf
50295 sf
9
New BUA on subdivided lots (subject to
permitting) (sq ft)
148236 sf
32019 sf
10
New BUA not on subdivided lots (subject to
permitting) (sf)
142780 sf
18276 sf
11
Offsite BUA (sq ft)
12
Breakdown of new BUA not on subdivided lots:
Parking (sq ft)
- Sidewalk (sq ft)
Roof (sq ft)
- Roadway (sq ft)
124469 sf
10736 sf
Future (sq ft)
- er, ease spec n e commen ox
below (sq ft)
18311 sf
7540 sf
13
New infiltrating permeable pavement on
subdivided lots (sq ft)
14
New infiltrating permeable pavement not on
subdivided lots (sq ft)
15
Existing BUA that will remain (not subject to
Ipermifting) (sq ft)
16
Existing BUA that is already permitted (sq ft)
17
Existing BUA that will be removed (sq ft)
18
Percent BUA
49%
51%
19
Design sto m (inches)
1.0 in
1.0 in
20
Design volume of SCM (cu ft)
31705 cf
5356 cf
21 Calculation method for design volume —J
JADDITIONAL IN ORMATION 11111111F-
JlPlease use this space to provide any additional information about the
22 drainage area(s):
Simple
Simple
The other BUA listed is for the surface are of the wet pond which is
considered as impervious