Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0022622_Regional Office Historical File Pre 2018
Michael F, Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality May 16, 2003 David Kraus, City Manager City of Mount Holly 131 South Main Street Mount Holly, NC Subject: Permit No. WQ0022622 City of Mount Holly Southgate Meadow Wastewater Collection System Extension Gaston County Dear Mr. Kraus;. In accordance with your application received March 24, 2003, we are forwarding herewith Permit No. WQ0022622, dated May 16, 2003, to the City of Mount Holly for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and 3) the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215,6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 919 N. Main Street, Mooresville, NC 28115 Internet http://h2o.enr.state,nc,us/ Telephone (704) 663-1699 Fax (704) 663-6040 DENR Customer Service Center An Equal Opportunity Action Employer Telephone 1 800 623-7748 50% recycled/10% post -consumer paper City of Mount Holly Page 2 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Mount Holly for the construction and operation of approximately 460 linear feet of 8-inch gravity sewer to serve a 20 unit townhome development as part of the Southgate Meadows project, and the discharge of 7200 gallons per day of collected domestic wastewater into the City of Mount Holly's existing sewerage system, pursuant to the application received March 24, 2003, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, d. /24c for Alan Klimek, P.E. cc: Gaston County Health Department Mooresville Regional Office, Water Quality Section (VVWTF Permit No. NC0021156) Atlantic Plan Engineering Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data, 3. The wastewater collection facilities shall be properly maintained and operated at ail times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004, and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. in the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and a statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall report by telephone to the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 16th day of May, 2003. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klima, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0022622 05/16/03 Permit Number 1�VE' 0022622 Permit Tracking Slip Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dee.browder Permitted Flow 7200 Facility Facility Name Southgate Meadows Location Address Owner Owner Name City of Mount Holly Da Events Scheduled Orig, Issue App Received Draft initiated Issuance 03/24/03 Regulated Activities Apartment complex Condominium Outfail INUL„L Status Project Type In review New Project Version Permit Contact Affiiiatl.. n. Major/Minor Minor Permit Classification Individual Region Mooresville County Gaston Facility Contact Affiliation Owner Type Government - Municipal Owner Affiliation David Kraus 131 South Main Street Mount Holly NC 28t20 Public Notice Issue Effective Requested/Received Events waterbody Name Stream Index Number Additional information requested Additional information received Expiration Current Class Subbasin FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FO S PAGE USE THE TAB KEY TO MOVE FR 1. Owner: la. City of Mount Holly Full Legal Name (company, municipality, HOA, utility, e Application Number: (to be completed by DWQ) lb. David Kraus, City Manager 0 ning Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) The legal entity who will own this system is: ❑ Individual ❑ Federal Municipality ❑ StatelC©unty ❑ Private Partnership 0 Corporation ❑ Other (specify): 1 d. 131 South Main Street Street Address North Carolina State lh. 1.704) 827-3931 11 704) 822-2933 Telephone Facsimile o 2 Project (Facility) Information: a. 2a. Southgate Meadows ti Brief Project Name (permit will refer to this name) 3, Contact Person, 3a, Richard Franklin, Engineer le. Mount Holly City l g. 28120 Zip Code E-mail 2b. Gaston County Where Project is Lot Name and Affiliation of Someone Who Can AnswerQuestions About this Application 3b. (828) 327-2621 Phone Number 1 Project is N 2.___ Owner is ® Public (skip to 1 2a. It private, applicant will be: Retaining Ownership (i.e. store, church, single office,. etc.) ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) 0 Selling units (lots, townhomes, etc, - go to Item B(2b)) 3. City of Mount Holly Owner of Wastewater Treatment Fa 4a. City of Mount Holly Name of WWTF Q5a, City of Mount Holly Z Owner of Downstream Sewer 3c. atlplan@conninc.corn E-mail permit) If Modification, Permit No,: Private (go to Item 2(a)) 2b. If sold, facilities owned by a (must choose one ❑ Public Utility (Instruction III) Homeowner Assoc,/Developer (Instruction IV TF) Treating Wastewater From This Project 4b. NC0021156 WWTF Permit No. 5b. 88" 5c Receiving Sewer Size Permit Number of The origin of this wastewater is (check all that apply): ❑ Residential Subdivision ► Apartments/Condominiums ❑ Mobile Home Park ❑ School ❑ Restaurant ❑ Office Car Wash ❑ Institution ❑ Hospital El Church El Nursing Home El Other (specify): 7, Volume of wastewater to be permitter[ in this project: 7200 gallons per day 100 % Domestic/Commercial % Industrial % Other (specify): 8. If the permitted flow is zero, indicate why: 0 Interceptor Lie Flow will be permitted is subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected FAST -TRACK APPLICATION f lr RAVITY SEWERS, PUMP STATIONS, AN FORCE MAINS PAGE 2 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). 20 3BD Townhome @ 360 GPD/3BD = 7200 GPD 10. Summary of Sewer Linea to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8" 460 Ift 2 0 0 bb.r " ENTER TOTAL LINE LENGTH IN MILES 0.087 Q Summary of Pump Stations to be Permitted (attach additional sheets Cit Location ID Design Flow 0 (as shown on plans) (MGD) U. Operational Point GPM ia TDH sary) Gravity or Force Main (pull down menu) Gravity Gravity Gravity Gravity Gravity Gravity Gravity Power Reliability Option. (dual line feed, permanent generator w/ATS, portable generator w/autodiaier, wet well storage) 12, Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force CO Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? Yes D No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO CO ES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? WetlandlStream Crossings - General Permit or 401 Certification? D Yes 0 No N/A Sedimentation and Erosion Control Plan? Yes © No © N/A Stormwater? i +l; Yes 0 No 0 N/A FAST -TRACK. ICATION for GRAVITY S S, PUMP STATIONS, AND FORCE+ MAINS PAGE 3 z 0 Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: ►ii A Watershed Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, ►`psi A Watershed Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID Name of Waterbody Stream Waterbody on Map Waterbody County River Basin Index Classification Submit the 8.5" x 11" topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: 1 attest that this application for Southgate Meadows has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if a#required parts of this application are not completed and the ;' if all required supporting documentation and attachments am not included, this application package is subject". trig med as incomplete. Note. In accordance with North Carokna General Statutes 143-215.6A and 143-21 .'.B, any pers'•n o knowingly makes any false statement, representation, or cert'ifrcatkrn in any application shall • guilty of a Cl ° sdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, r t r per violatio la. Signing Official Signature 2. Professional Engineer's Certification: Dale I attest that this applcation for Southgate Meadows has been reviewed by me and is 0 accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting 1— documentation to the best of my knowledge, 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations„ Gravity Sewer Minimum Design Criteria for Gravity Sewers _ adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 as well as civil penalties up to $25, 000 per violation. 2a, Richard .t. Franklin Professional Engineer Name 2b. Atlantic Plan Engineering Engineering Firm 2c. PO BOX 1691 Address 2d. Hickory City 2g. 1628) 327-2621 2h. _(82 &) 327-0931 Telephone Facsimile 2e, NC 2f. 2&603 State Zip 2i. atiplantconninc.com E-mail