HomeMy WebLinkAboutWQ0003271_Compliance Evaluation Inspection_20210415DocuSign Envelope ID: C262791 B-2CAF-4AF1 -9D4B-760FBAD60868
ROY COOPER
Governor
DIONNE DELLI-GATTI
Secretary`uK ,
S. DANIEL SMITH NORTH CAROLINA
Director Environmental Quality
April 19, 2021
Travis Dupree, Vice President, Project Management and Engineering
Carolina Water Service, Inc. of North Carolina
4944 Parkway Plaza Blvd, Suite 325
Charlotte, North Carolina 28224
SUBJECT: Compliance Inspection Report
Hestron Park WWTF
Non -discharge Permit No. WQ0003271
Carteret County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the Hestron Park WWTF on
4/15/2021. This inspection was conducted to verify that the facility is operating in compliance with the
conditions and limitations specified in Non -discharge Permit No. WQ0003271. The findings and
comments noted during this inspection are provided in the enclosed copy of the inspection report
entitled "Compliance Inspection Report". There were no significant issues or findings noted during the
inspection and therefore, a response to this inspection report is not required.
If you should have any questions, please do not hesitate to contact Helen Perez with the Water
Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at
helen.perez@ncdenr.gov.
ATTACHMENTS
Cc: Stacy Goff — electronic copy
Anthony Chilton — electronic copy
Uploaded to Laserfiche
Sincerely,
DocuSigned by:
Toµ 'TIn�cl oti for
7F141 E73B6F3456...
Morelia Sanchez -King, Regional Supervisor
Water Quality Regional Operations Section
Wilmington Regional Office
Division of Water Resources, NCDEQ
North Carolina Department of Environmental Quality I Division of Water Resources
Wilmington Regional Office 1 127 CardinaI Drive Extension I Wilmington North Carolina 26405
DocuSign Envelope ID: A246EFEC-8FB8-40A6-A4E2-704BOB6B3AAD
Compliance Inspection Report
Permit: WQ0003271 Effective: 03/01/19 Expiration: 12/31/23 Owner : Carolina Water Service Inc of North Carolina
SOC: Effective: Expiration: Facility: Hestron Park WWTF
County: Carteret 216 NC 24
Region: Wilmington
Morehead City NC 28557
Contact Person: Stacy A Goff Title: ORC Phone: 252-659-0515
Directions to Facility:
System Classifications: WW2,
Primary ORC: Stacy Allen Goff
Secondary ORC(s):
On -Site Representative(s):
On -site representative
Related Permits:
Inspection Date: 04/15/2021
Primary Inspector: Helen I Perez
Secondary Inspector(s):
Certification: 998882
Stacy A Goff
Entry Time 10:OOAM
DocuSigned by:
1 D645B4A39694BE_
Phone: 252-808-5955
252-659-0515
Exit Time: 11:OOAM
Phone: 910-796-7387
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: High Rate Infiltration
Facility Status: Compliant ❑ Not Compliant
Question Areas:
Treatment Flow Measurement -Effluent Treatment Flow Measurement -Influent Miscellaneous Questions
Treatment Flow Measurement -Water Treatment Treatment Barscreen
Use Records
Treatment Filters Record Keeping Treatment Activated Sludge
Treatment Influent Pump Station Treatment Clarifiers Treatment Disinfection
End Use -Infiltration Treatment Flow Measurement Treatment Return pumps
Standby Power
(See attachment summary)
Page 1 of 7
DocuSign Envelope ID: A246EFEC-8FB8-4OA6-A4E2-704BOB6B3AAD
Permit: WQ0003271 Owner - Facility: Carolina Water Service Inc of North Carolina
Inspection Date: 04/15/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
A routine compliance inspection of the Hestron Park WWTF was conducted on April 15, 2021. The purpose of the evaluation
was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit WQ0003271.
Stacy Goff, ORC, was present during the inspection.
Hestron Park WWTF is a 67,000 gpd permitted extended aeration plant with dual rotary distributor high -rate infiltration areas.
The plant averages 12,000 to 15,000 gpd from the neighboring shopping center. Afile review of NDMRs since 2018 shows
one violation issued for a BOD exceedance in 2018 and two violations in 2020 for BOD and Ammonia exceedances. A review
of GW-59s shows all five wells have exceedances in Total Dissolved Solids which is high in the influent. MW #4 and #5 have
had exceedances in nitrates and the Wilmington Regional Office continues to monitor the trends.
The facility is compliant with Non -Discharge Permit WQ0003271. Please review the comment sections of the inspection
report for more details.
Page 2 of 7
DocuSign Envelope ID: A246EFEC-8FB8-4OA6-A4E2-704BOB6B3AAD
Permit: WQ0003271
Inspection Date: 04/15/2021
Owner - Facility: Carolina Water Service Inc of North Carolina
Inspection Type: Compliance Evaluation Reason for Visit: Routine
Type
Yes No NA NE
Reuse (Quality)
❑
Single Family Spray, LR
❑
Lagoon Spray, LR
❑
Activated Sludge Spray, LR
❑
Activated Sludge Drip, LR
❑
Activated Sludge Spray, HR
❑
Recycle/Reuse
❑
Single Family Drip
❑
Infiltration System
Treatment Yes No NA NE
Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑
Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑
Comment: No comment.
Treatment Influent Pump Station
Yes No NA NE
Is the pump station free of bypass lines or structures?
❑ ❑ ❑
Is the general housekeeping acceptable?
❑ ❑ ❑
Are all pumps present?
❑ ❑ ❑
Are all pumps operable?
❑ ❑ ❑
Are floats/controls operable?
0
❑ ❑ ❑
Are audio and visual alarms available?
❑ ❑ ❑
Are audio and visual alarms operational?
❑ ❑ ❑
# Are SCADA/Telemetry alarms required?
❑ ❑ ❑
Are SCADA/Telemetry available?
❑
❑ ❑
Are SCADA/Telemetry operational?
❑
❑ ❑
Comment: The influent DumD station. located in the Darkina lot of the neiahborina shODDina center. is the
only pump station in the deemed collection system. Weeks inspections and maintenance are
reported on a tablet using Lucity software program. The collection system map is also located
on this software. FOG information is mailed out to customers of the shopping center twice a
year. All of the Carolina Water Service's pump stations receive a thorough inspection annually b�
a third party contractor for any issues.
Treatment Flow Measurement -Influent
Yes No NA NE
Is flowmeter calibrated annually?
❑
❑ ❑
Is flowmeter operating properly?
❑
❑ ❑
Does flowmeter monitor continuously?
❑
❑ ❑
Does flowmeter record flow?
❑
❑ ❑
Page 3 of 7
DocuSign Envelope ID: A246EFEC-8FB8-4OA6-A4E2-704BOB6B3AAD
Permit: WQ0003271 Owner - Facility: Carolina Water Service Inc of North Carolina
Inspection Date: 04/15/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Does flowmeter appear to monitor accurately? ❑ ❑ 0 ❑
Comment:
Treatment Flow Measurement -Water Use Records Yes No NA NE
Is water use metered? ❑ ❑ 0 ❑
Are the daily average values properly calculated? ❑ ❑ 0 ❑
Comment:
Treatment Flow Measurement -Effluent Yes No NA NE
Is flowmeter calibrated annually? 0 ❑ ❑ ❑
Is flowmeter operating properly? ❑ ❑ ❑
Does flowmeter monitor continuously? 0 ❑ ❑ ❑
Does flowmeter record flow? 0 ❑ ❑ ❑
Does flowmeter appear to monitor accurately? 0 ❑ ❑ ❑
Comment: The flowmeter was calibrated on 08-24-2020 by Clearwater Inc.
Standby Power Yes No NA NE
Is automatically activated standby power available? ❑ ❑ ❑
Is generator tested weekly by interrupting primary power source? ❑ ❑ ❑
Is generator operable? ❑ ❑ ❑
Does generator have adequate fuel? ❑ ❑ ❑
Comment: The generator was not operable during inspection. The operator stated that a work order had
already been issued for repair. In addition to testing the generator, an inspection and preventativ
maintenance of the generator is performed annually.
Treatment Barscreen
/ ]r- ]..�.1N
Is it free of excessive debris? 0 ❑ ❑ ❑
Is disposal of screenings in compliance? 0 ❑ ❑ ❑
Are the bars spaced properly? ❑ ❑ ❑
Is the unit in good condition? 0 ❑ ❑ ❑
Comment: The manual bar screen is cleaned daily. Screenings are dumped in the Brandywine Bay
WWTF's dumpster for disposal. From the barscreen, the influent flows through the splitter box
directly to the aeration basins. There is no EQ tank.
Treatment Activated Sludge
Yes No NA NE
Is the aeration mechanism operable?
0
❑ ❑ ❑
Is the aeration basin thoroughly mixed?
❑ ❑ ❑
Is the aeration equipment easily accessed?
❑ ❑ ❑
Is Dissolved Oxygen adequate?
❑
❑ ❑
Are Settleometer results acceptable?
❑
❑ ❑
Is activated sludge an acceptable color?
❑ ❑ ❑
Page 4 of 7
DocuSign Envelope ID: A246EFEC-8FB8-4OA6-A4E2-704BOB6B3AAD
Permit: WQ0003271 Owner - Facility: Carolina Water Service Inc of North Carolina
Inspection Date: 04/15/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Comment: Process control of the dual extended aeration basins consists of monitoring DO and a weekly
settleometer test.
Treatment Clarifiers Yes No NA NE
Are the weirs level? 0 ❑ ❑ ❑
Are the weirs free of solids and algae? 0 ❑ ❑ ❑
Is the scum removal system operational? ❑ ❑ ❑
Is the scum removal system accessible? ❑ ❑ ❑
Is the sludge blanket at an acceptable level? ❑ ❑ ❑
Is the effluent from the clarifier free of excessive solids? 0 ❑ ❑ ❑
Comment: No comment.
Treatment Return pumps Yes No NA NE
Are they in place? 0 ❑ ❑ ❑
Are they operational? 0 ❑ ❑ ❑
Comment: The WAS flows to the aerated sludge holding tank which is pumped and hauled by Aragona
Brothers once a month.
Treatment Filters Yes No NA NE
Is the filter media present? ❑ ❑ ❑
Is the filter media the correct size and type? ❑ ❑ ❑
Is the air scour operational? ❑ ❑ ❑
Is the scouring acceptable? ❑ ❑ ❑
Is the clear well free of excessive solids? ❑ ❑ ❑
Is the mud well free of excessive solids and filter media? ❑ ❑ ❑
Does backwashing frequency appear adequate? 0 ❑ ❑ ❑
Comment: The dual tertiary filters are manually backwashed once a day.
Treatment Disinfection
Yes No NA NE
Is the system working?
❑ ❑ ❑
Do the fecal coliform results indicate proper disinfection?
❑ ❑ ❑
Is there adequate detention time (>=30 minutes)?
❑
❑ ❑
Is the system properly maintained?
❑ ❑ ❑
If gas, does the cylinder storage appear safe?
❑
❑ ❑
Is the fan in the chlorine feed room and storage area operable?
❑
❑ ❑
Is the chlorinator accessible?
❑ ❑ ❑
If tablets, are tablets present?
0
❑ ❑ ❑
Are the tablets the proper size and type?
❑
❑ ❑
Is contact chamber free of sludge, solids, and growth?
❑ ❑ ❑
If UV, are extra UV bulbs available?
❑
❑ 0❑
Page 5 of 7
DocuSign Envelope ID: A246EFEC-8FB8-4OA6-A4E2-704BOB6B3AAD
Permit: WQ0003271 Owner - Facility: Carolina Water Service Inc of North Carolina
Inspection Date: 04/15/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine
If UV, is the UV intensity adequate? ❑ ❑ 0 ❑
# Is it a dual feed system? ❑ ❑ 0 ❑
Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? ❑ ❑ 0 ❑
If yes, then is there a Risk Management Plan on site? ❑ ❑ 0 ❑
If yes, then what is the EPA twelve digit ID Number? (1000- - )
If yes, then when was the RMP last updated?
Comment: Disinfection consists of liquid chlorine and a tablet chlorinator as back-up.
Record Keeping
Yes No NA NE
Is a copy of current permit available?
0
❑ ❑ ❑
Are monitoring reports present: NDMR?
❑
❑ ❑
NDAR?
❑
❑ ❑
Are flow rates less than of permitted flow?
❑ ❑ ❑
Are flow rates less than of permitted flow?
❑ ❑ ❑
Are application rates adhered to?
❑ ❑ ❑
Is GW monitoring being conducted, if required (GW-59s submitted)?
❑ ❑ ❑
Are all samples analyzed for all required parameters?
❑ ❑ ❑
Are there any 2L GW quality violations?
❑ ❑ ❑
Is GW-59A certification form completed for facility?
❑
❑ ❑
Is effluent sampled for same parameters as GW?
❑ ❑ ❑
Do effluent concentrations exceed GW standards?
❑
❑ ❑
Are annual soil reports available?
❑
❑ ❑
# Are PAN records required?
❑
❑ ❑
# Did last soil report indicate a need for lime?
❑
❑ ❑
If so, has it been applied?
❑
❑ ❑
Are operational logs present?
❑ ❑ ❑
Are lab sheets available for review?
❑ ❑ ❑
Do lab sheets support data reported on NDMR?
❑
❑ ❑
Do lab sheets support data reported on GW-59s?
❑
❑ ❑
Are Operational and Maintenance records present?
❑ ❑ ❑
Were Operational and Maintenance records complete?
❑ ❑ ❑
Has permittee been free of public complaints in last 12 months?
❑
❑ ❑
Is a copy of the SOC readily available?
❑
❑ 0❑
No treatment units bypassed since last inspection?
0
❑ ❑ ❑
Comment: Operation and maintenance records consists of daily
check sheets and notes. Field parameters
are recorded on daily logs.
End Use -Infiltration Yes No NA NE
Page 6 of 7
DocuSign Envelope ID: A246EFEC-8FB8-4OA6-A4E2-704BOB6B3AAD
Permit: WQ0003271 Owner - Facility: Carolina Water Service Inc of North Carolina
Inspection Date: 04/15/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine
# Is the application High Rate or Low Rate?
High Rate
Are buffers maintained?
0
❑ ❑ ❑
Are any supply wells within the CB?
❑
❑ ❑
Are any supply wells within 250' of the CB?
❑
❑ ❑
Is municipal water available in the area?
0
❑ ❑ ❑
Are GW monitoring wells required?
0
❑ ❑ ❑
Are GW monitoring wells located properly w/ respect to RB and CB?
0
❑ ❑ ❑
Are GW monitoring wells properly constructed, including screened interval?
❑
❑ ❑
Is a usable green area maintained?
❑
❑ 0 ❑
Is the disposal site acceptable?
0
❑ ❑ ❑
Is the distribution equipment acceptable?
0
❑ ❑ ❑
Is the disposal site free of ponding?
0
❑ ❑ ❑
Is the disposal site free of breakout?
0
❑ ❑ ❑
Are the disposal sites free of solids, algae, etc.?
0
❑ ❑ ❑
Do the records show that the fields are properly maintained?
0
❑ ❑ ❑
Are the disposal sites free of vegetation?
0
❑ ❑ ❑
Do any surface water features appear to be adversely impacted by GW discharge?
❑
❑ 0 ❑
No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.?
0
❑ ❑ ❑
Comment: The rotary distributors were operable and evenly distributing effluent on infiltration fields. One
field is dosed at a time. There are 5 GW monitoring wells, sampled and tested by
Enviromental
One. MW #4 is approximately 40 feet from the edge of field #1 and has had nitrate violations.
These trends are being monitored by the Wilmington Regional Office.
Page 7 of 7