Loading...
HomeMy WebLinkAboutWQ0003271_Compliance Evaluation Inspection_20210415DocuSign Envelope ID: C262791 B-2CAF-4AF1 -9D4B-760FBAD60868 ROY COOPER Governor DIONNE DELLI-GATTI Secretary`uK , S. DANIEL SMITH NORTH CAROLINA Director Environmental Quality April 19, 2021 Travis Dupree, Vice President, Project Management and Engineering Carolina Water Service, Inc. of North Carolina 4944 Parkway Plaza Blvd, Suite 325 Charlotte, North Carolina 28224 SUBJECT: Compliance Inspection Report Hestron Park WWTF Non -discharge Permit No. WQ0003271 Carteret County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Hestron Park WWTF on 4/15/2021. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0003271. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Helen Perez with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at helen.perez@ncdenr.gov. ATTACHMENTS Cc: Stacy Goff — electronic copy Anthony Chilton — electronic copy Uploaded to Laserfiche Sincerely, DocuSigned by: Toµ 'TIn�cl oti for 7F141 E73B6F3456... Morelia Sanchez -King, Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 1 127 CardinaI Drive Extension I Wilmington North Carolina 26405 DocuSign Envelope ID: A246EFEC-8FB8-40A6-A4E2-704BOB6B3AAD Compliance Inspection Report Permit: WQ0003271 Effective: 03/01/19 Expiration: 12/31/23 Owner : Carolina Water Service Inc of North Carolina SOC: Effective: Expiration: Facility: Hestron Park WWTF County: Carteret 216 NC 24 Region: Wilmington Morehead City NC 28557 Contact Person: Stacy A Goff Title: ORC Phone: 252-659-0515 Directions to Facility: System Classifications: WW2, Primary ORC: Stacy Allen Goff Secondary ORC(s): On -Site Representative(s): On -site representative Related Permits: Inspection Date: 04/15/2021 Primary Inspector: Helen I Perez Secondary Inspector(s): Certification: 998882 Stacy A Goff Entry Time 10:OOAM DocuSigned by: 1 D645B4A39694BE_ Phone: 252-808-5955 252-659-0515 Exit Time: 11:OOAM Phone: 910-796-7387 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: High Rate Infiltration Facility Status: Compliant ❑ Not Compliant Question Areas: Treatment Flow Measurement -Effluent Treatment Flow Measurement -Influent Miscellaneous Questions Treatment Flow Measurement -Water Treatment Treatment Barscreen Use Records Treatment Filters Record Keeping Treatment Activated Sludge Treatment Influent Pump Station Treatment Clarifiers Treatment Disinfection End Use -Infiltration Treatment Flow Measurement Treatment Return pumps Standby Power (See attachment summary) Page 1 of 7 DocuSign Envelope ID: A246EFEC-8FB8-4OA6-A4E2-704BOB6B3AAD Permit: WQ0003271 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 04/15/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: A routine compliance inspection of the Hestron Park WWTF was conducted on April 15, 2021. The purpose of the evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit WQ0003271. Stacy Goff, ORC, was present during the inspection. Hestron Park WWTF is a 67,000 gpd permitted extended aeration plant with dual rotary distributor high -rate infiltration areas. The plant averages 12,000 to 15,000 gpd from the neighboring shopping center. Afile review of NDMRs since 2018 shows one violation issued for a BOD exceedance in 2018 and two violations in 2020 for BOD and Ammonia exceedances. A review of GW-59s shows all five wells have exceedances in Total Dissolved Solids which is high in the influent. MW #4 and #5 have had exceedances in nitrates and the Wilmington Regional Office continues to monitor the trends. The facility is compliant with Non -Discharge Permit WQ0003271. Please review the comment sections of the inspection report for more details. Page 2 of 7 DocuSign Envelope ID: A246EFEC-8FB8-4OA6-A4E2-704BOB6B3AAD Permit: WQ0003271 Inspection Date: 04/15/2021 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Type: Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Reuse (Quality) ❑ Single Family Spray, LR ❑ Lagoon Spray, LR ❑ Activated Sludge Spray, LR ❑ Activated Sludge Drip, LR ❑ Activated Sludge Spray, HR ❑ Recycle/Reuse ❑ Single Family Drip ❑ Infiltration System Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑ Comment: No comment. Treatment Influent Pump Station Yes No NA NE Is the pump station free of bypass lines or structures? ❑ ❑ ❑ Is the general housekeeping acceptable? ❑ ❑ ❑ Are all pumps present? ❑ ❑ ❑ Are all pumps operable? ❑ ❑ ❑ Are floats/controls operable? 0 ❑ ❑ ❑ Are audio and visual alarms available? ❑ ❑ ❑ Are audio and visual alarms operational? ❑ ❑ ❑ # Are SCADA/Telemetry alarms required? ❑ ❑ ❑ Are SCADA/Telemetry available? ❑ ❑ ❑ Are SCADA/Telemetry operational? ❑ ❑ ❑ Comment: The influent DumD station. located in the Darkina lot of the neiahborina shODDina center. is the only pump station in the deemed collection system. Weeks inspections and maintenance are reported on a tablet using Lucity software program. The collection system map is also located on this software. FOG information is mailed out to customers of the shopping center twice a year. All of the Carolina Water Service's pump stations receive a thorough inspection annually b� a third party contractor for any issues. Treatment Flow Measurement -Influent Yes No NA NE Is flowmeter calibrated annually? ❑ ❑ ❑ Is flowmeter operating properly? ❑ ❑ ❑ Does flowmeter monitor continuously? ❑ ❑ ❑ Does flowmeter record flow? ❑ ❑ ❑ Page 3 of 7 DocuSign Envelope ID: A246EFEC-8FB8-4OA6-A4E2-704BOB6B3AAD Permit: WQ0003271 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 04/15/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine Does flowmeter appear to monitor accurately? ❑ ❑ 0 ❑ Comment: Treatment Flow Measurement -Water Use Records Yes No NA NE Is water use metered? ❑ ❑ 0 ❑ Are the daily average values properly calculated? ❑ ❑ 0 ❑ Comment: Treatment Flow Measurement -Effluent Yes No NA NE Is flowmeter calibrated annually? 0 ❑ ❑ ❑ Is flowmeter operating properly? ❑ ❑ ❑ Does flowmeter monitor continuously? 0 ❑ ❑ ❑ Does flowmeter record flow? 0 ❑ ❑ ❑ Does flowmeter appear to monitor accurately? 0 ❑ ❑ ❑ Comment: The flowmeter was calibrated on 08-24-2020 by Clearwater Inc. Standby Power Yes No NA NE Is automatically activated standby power available? ❑ ❑ ❑ Is generator tested weekly by interrupting primary power source? ❑ ❑ ❑ Is generator operable? ❑ ❑ ❑ Does generator have adequate fuel? ❑ ❑ ❑ Comment: The generator was not operable during inspection. The operator stated that a work order had already been issued for repair. In addition to testing the generator, an inspection and preventativ maintenance of the generator is performed annually. Treatment Barscreen / ]r- ]..�.1N Is it free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screenings in compliance? 0 ❑ ❑ ❑ Are the bars spaced properly? ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: The manual bar screen is cleaned daily. Screenings are dumped in the Brandywine Bay WWTF's dumpster for disposal. From the barscreen, the influent flows through the splitter box directly to the aeration basins. There is no EQ tank. Treatment Activated Sludge Yes No NA NE Is the aeration mechanism operable? 0 ❑ ❑ ❑ Is the aeration basin thoroughly mixed? ❑ ❑ ❑ Is the aeration equipment easily accessed? ❑ ❑ ❑ Is Dissolved Oxygen adequate? ❑ ❑ ❑ Are Settleometer results acceptable? ❑ ❑ ❑ Is activated sludge an acceptable color? ❑ ❑ ❑ Page 4 of 7 DocuSign Envelope ID: A246EFEC-8FB8-4OA6-A4E2-704BOB6B3AAD Permit: WQ0003271 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 04/15/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine Comment: Process control of the dual extended aeration basins consists of monitoring DO and a weekly settleometer test. Treatment Clarifiers Yes No NA NE Are the weirs level? 0 ❑ ❑ ❑ Are the weirs free of solids and algae? 0 ❑ ❑ ❑ Is the scum removal system operational? ❑ ❑ ❑ Is the scum removal system accessible? ❑ ❑ ❑ Is the sludge blanket at an acceptable level? ❑ ❑ ❑ Is the effluent from the clarifier free of excessive solids? 0 ❑ ❑ ❑ Comment: No comment. Treatment Return pumps Yes No NA NE Are they in place? 0 ❑ ❑ ❑ Are they operational? 0 ❑ ❑ ❑ Comment: The WAS flows to the aerated sludge holding tank which is pumped and hauled by Aragona Brothers once a month. Treatment Filters Yes No NA NE Is the filter media present? ❑ ❑ ❑ Is the filter media the correct size and type? ❑ ❑ ❑ Is the air scour operational? ❑ ❑ ❑ Is the scouring acceptable? ❑ ❑ ❑ Is the clear well free of excessive solids? ❑ ❑ ❑ Is the mud well free of excessive solids and filter media? ❑ ❑ ❑ Does backwashing frequency appear adequate? 0 ❑ ❑ ❑ Comment: The dual tertiary filters are manually backwashed once a day. Treatment Disinfection Yes No NA NE Is the system working? ❑ ❑ ❑ Do the fecal coliform results indicate proper disinfection? ❑ ❑ ❑ Is there adequate detention time (>=30 minutes)? ❑ ❑ ❑ Is the system properly maintained? ❑ ❑ ❑ If gas, does the cylinder storage appear safe? ❑ ❑ ❑ Is the fan in the chlorine feed room and storage area operable? ❑ ❑ ❑ Is the chlorinator accessible? ❑ ❑ ❑ If tablets, are tablets present? 0 ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ ❑ Is contact chamber free of sludge, solids, and growth? ❑ ❑ ❑ If UV, are extra UV bulbs available? ❑ ❑ 0❑ Page 5 of 7 DocuSign Envelope ID: A246EFEC-8FB8-4OA6-A4E2-704BOB6B3AAD Permit: WQ0003271 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 04/15/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine If UV, is the UV intensity adequate? ❑ ❑ 0 ❑ # Is it a dual feed system? ❑ ❑ 0 ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? ❑ ❑ 0 ❑ If yes, then is there a Risk Management Plan on site? ❑ ❑ 0 ❑ If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: Disinfection consists of liquid chlorine and a tablet chlorinator as back-up. Record Keeping Yes No NA NE Is a copy of current permit available? 0 ❑ ❑ ❑ Are monitoring reports present: NDMR? ❑ ❑ ❑ NDAR? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are application rates adhered to? ❑ ❑ ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? ❑ ❑ ❑ Are all samples analyzed for all required parameters? ❑ ❑ ❑ Are there any 2L GW quality violations? ❑ ❑ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ❑ Is effluent sampled for same parameters as GW? ❑ ❑ ❑ Do effluent concentrations exceed GW standards? ❑ ❑ ❑ Are annual soil reports available? ❑ ❑ ❑ # Are PAN records required? ❑ ❑ ❑ # Did last soil report indicate a need for lime? ❑ ❑ ❑ If so, has it been applied? ❑ ❑ ❑ Are operational logs present? ❑ ❑ ❑ Are lab sheets available for review? ❑ ❑ ❑ Do lab sheets support data reported on NDMR? ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? ❑ ❑ ❑ Are Operational and Maintenance records present? ❑ ❑ ❑ Were Operational and Maintenance records complete? ❑ ❑ ❑ Has permittee been free of public complaints in last 12 months? ❑ ❑ ❑ Is a copy of the SOC readily available? ❑ ❑ 0❑ No treatment units bypassed since last inspection? 0 ❑ ❑ ❑ Comment: Operation and maintenance records consists of daily check sheets and notes. Field parameters are recorded on daily logs. End Use -Infiltration Yes No NA NE Page 6 of 7 DocuSign Envelope ID: A246EFEC-8FB8-4OA6-A4E2-704BOB6B3AAD Permit: WQ0003271 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 04/15/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine # Is the application High Rate or Low Rate? High Rate Are buffers maintained? 0 ❑ ❑ ❑ Are any supply wells within the CB? ❑ ❑ ❑ Are any supply wells within 250' of the CB? ❑ ❑ ❑ Is municipal water available in the area? 0 ❑ ❑ ❑ Are GW monitoring wells required? 0 ❑ ❑ ❑ Are GW monitoring wells located properly w/ respect to RB and CB? 0 ❑ ❑ ❑ Are GW monitoring wells properly constructed, including screened interval? ❑ ❑ ❑ Is a usable green area maintained? ❑ ❑ 0 ❑ Is the disposal site acceptable? 0 ❑ ❑ ❑ Is the distribution equipment acceptable? 0 ❑ ❑ ❑ Is the disposal site free of ponding? 0 ❑ ❑ ❑ Is the disposal site free of breakout? 0 ❑ ❑ ❑ Are the disposal sites free of solids, algae, etc.? 0 ❑ ❑ ❑ Do the records show that the fields are properly maintained? 0 ❑ ❑ ❑ Are the disposal sites free of vegetation? 0 ❑ ❑ ❑ Do any surface water features appear to be adversely impacted by GW discharge? ❑ ❑ 0 ❑ No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.? 0 ❑ ❑ ❑ Comment: The rotary distributors were operable and evenly distributing effluent on infiltration fields. One field is dosed at a time. There are 5 GW monitoring wells, sampled and tested by Enviromental One. MW #4 is approximately 40 feet from the edge of field #1 and has had nitrate violations. These trends are being monitored by the Wilmington Regional Office. Page 7 of 7