Loading...
HomeMy WebLinkAboutWQ0038055_Application (FTSE)_20150929DWR grosiz-71 CVrE SEP 2 9 2015 v w FAYETTEVILLL riLLOU JI l ul rig• FAST -TRACK APPLICATION (FTA 10-14) Division of Water Resources for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS State of North Carolina Department of Environment and Natural Resources Division of Water Resources General — When submitting this application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. For more information, visit the Water Quality Permitting Section's website or; contact the Regional Office serving your county Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation to the appropriate Regional Office (see page 3). A. Cover Letter: ® Include a brief project narrative describing the final design (i.e system and/or pump station to ultimately serve 500 homes, but flow for only 100 homes being requested now). For modifications, clearly explain the reason for the modification (i.e. adding another phase, changing line size, length, etc). B. Application Form (FTA 10-14): ® Submit the completed and appropriately executed Fast -Track (FTA 10-14) Application. Any unauthorized content changes to this form shall result in the application being returned. If necessary for clarity or due to space restrictions, attachment to the application may be made, as long as the attachments are numbered to correspond to the section and item to which they refer. You do not need to submit detailed plans and specifications unless you respond NO to item B(13). ® The Professional Engineer's Certification of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. O The Applicant's Certification of the application shall be signed in accordance with 15A NCAC 02T .0106(b). Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). C. Application Fee: ® Submit a check in the amount of $480 to: North Carolina Department of Environment and Natural Resources (NCDENR). Checks shall be dated within 90 days of application submittal. D. Certificate of Public Convenience and Necessity (For Privately -Owned Public Utilities Only): D Per 15A NCAC 02T .0115(a)(1), provide two copies of the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide two copies of a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. ❑ The project name in the CPCN or letter must match that provided in Item A(2)a of this application. E. Operational Agreements (For Home/Property Owners' Associations and Developers of lots to be sold): Home/Property Owners' Associations ❑ Per 15A NCAC 02T .0115(c), submit the properly executed Operational Agreement (HOA 08-13). ❑ Per 15A NCAC 02T .0115(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. e Developers of lots to be sold ❑ Per 15A NCAC 02T .0115(b), submit the properly executed Operational Agreement (DEV 08-13). Even if the project may be turned over to a municipality upon completion, Form DEV 08-13 is required. INSTRUCTIONS FOR APPLICATION F"1'A 10-14 & St'PPORTING DOCUMENTATION Page I of 6 F. Downstream Sewer, WWTF Capacity and Flow Tracking/Acceptance Form (FTSE 08-13) Submit the completed and appropriately executed Flow Tracking/Acceptance for Sewer Extension Permit (FTSE 08-13) Form for all applications. The applicant (and owners of downstream sewers, pump stations and/or treatment facilities submitting form FTSE 08-13 certifies that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving treatment plant, and that the flow from this project will not cause capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving wastewater treatment plant. e Where the applicant is not the owner of the downstream sewer, submit two copies of form FTSE 08-13 from the owner of the downstream sewer and owner of the WWTF, if different. The flow acceptance indicated in form FTSE 08-13 must not expire prior to permit issuance and must be dated Tess than one year prior to the application date. :- Submittal of this application and form FTSE 08-13 indicates that owner has adequate capacity and will not violate G.S. 143-215.67(a). Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE 08-13. G. Site Map (All Application Packages): ® Submit an 8.5-inch x 11-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area and closest surface waters. Each map must include at a minimum: The location of the sewer line and pump stations and be of reproducible quality. Downstream connection points and the permit number for the receiving sewer (if known) Pump Station Locations and the longitude and latitude for each pump station (if applicable) El Include a street level map showing all relevant project areas. H. Stream Classification (WSCAS 01-15) O Submit the completed and appropriately executed Watershed Classification Attachment form (WSCAS 01-15) if any portion of the sewer system project is within 100 feet of any surface water or wetlands. A variance must be requested for encroachment within required setbacks or buffers pursuant to 15A NCAC 02T .0305(f) I. Environmental Assessments (Projects subject to an Environmental Assessment (EA)): Projects involving an Environmental Assessment per 15A NCAC 01 C .0408, must be submitted for a full technical review and must be submitted to the PERCS Unit on application forms provided by the Division. J. Alternative Sewer Systems ✓ Projects involving low pressure sewer systems, vacuum sewer systems and other alternative sewer systems must be submitted for a full technical review and must be submitted to the PERCS Unit on application forms provided by the Division. K. Flow Direction • Many wastewater treatment systems are entering into agreements for regionalization efforts and emergency treatment capacity. Parts of the system are installed so that the wastewater flow can be directed to more than one treatment facility. If this is the case with the project, please indicate in B(12) and give the permit number of the second facility. L. Certifications — Section C The application must be certified by both the applicant and the design engineer who is a North Carolina Registered Professional Engineer (PE). The applicant signature must match the signing official listed in Item A(1b). The PE should NOT certify the application if he/she is unfamiliar with 15A NCAC Chapter 2T, The Gravity Sewer Minimum Design Criteria (most recent version) and the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (most recent version), as applicable to the project. INSTRUCTIONS FOR APPLICATION FTA 10-14 & SUPPORTING DOCUMENTATION Page 2 of 6 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office Water Quality Section 2090 US Highway 70 Swannanoa, North Carolina 28778 (828) 296-4500 (828) 299-7043 Fax Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office Water Quality Section 225 Green Street Suite 714 Fayetteville, North Carolina 28301-5094 (910) 433-3300 (910) 486-0707 Fax Anson, Bladen, Cumberland, Harnett, Hoke, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland Mooresville Regional Office Water Quality Section 610 E. Center Avenue Mooresville, North Carolina 28115 (704) 663-1699 (704) 663-6040 Fax Alexander, Cabarrus, Catawba, Cleveland, Gaston, Iredell, Lincoln, Mecklenburg, Rowan, Stanly, Union Raleigh Regional Office Water Quality Section 1628 Mail Service Center Raleigh, North Carolina 27699-1628 (919) 791-4200 (919) 788-7159 Fax Chatham, Durham, Edgecombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson Washington Regional Office Water Quality Section 943 Washington Square Mall Washington, North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax Beaufort, Bertie, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office Water Quality Section 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 350-2004 Fax Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pender Winston-Salem Regional Office Water Quality Section 450 W. Hanes Mill Road Suite 300 Winston-Salem, North Carolina 27105 (336) 776-9800 Alamance, Allegheny, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin INSTRUCTIONS FOR APPLICATION FTA 10-14 & SUPPORTING DOCUMENTATION Page 3 of 6 Z 0 1- Q 0 IL Z Z 0 1- Q Ci a a Z 0 1- Q 0 LL Z F- a m USE THE TAB KEY TO MOVE FROM FIELD TO FIELD 1. Owner/Permittee: la. Campbell University Application Number. (to be completed by DWR) a o03S 0 CS - Full Legal Name (company, municipality, HOA, utility, etc.) 1b. Jim Roberts, Vice President for Business & Treasurer Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized signing officials) 1 c. The legal entity who will own this system is: ❑ Individual 0 Federal 0 Municipality 0 State/County ® Private Partnership ❑ Corporation 0 Other (specify): ld. PO Box 97 le. Buies Creek Mailing Address City 1 f. NC lg. 27506 State Zip Code lh. 919-893-1240 1 i. N/A 1j. roberts@campbell.edu Telephone Facsimile E-mail 2. Proiect (Facilitvl Information: 2a. Campbell University — South Residence Hall Brief Project Name (permit will refer to this name) 3. Contact Person: 3a. Roy P. Lorenzen , Senior Project Manager, Stewart Engineering 2b. Harnett County Where Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 919-866-4813 Phone Number 1. Project is ® New 3c. rorenzen@stevwartinc.com E-mail 0 Modification (of an existing permit) If Modification, Permit No.: 2. Owner is ❑ Public (skip to Item 8(3)) ® Private (go to Item 2(a)) 2a. If private, applicant will be: ® Retaining Ownership (i.e. store, church, single office, etc.) or 0 Leasing units (lots, townhomes, etc. - skip to Item 13(3)) 0 Selling units (lots, townhomes, etc. - go it, Item B(2b)) 3. Hamett County Public Utilities 2b. If sold, facilities owned by a (must choose one) ❑ Public Utility (Instruction D) ❑ Homeowner Assoc./Developer (Instruction E) Owner of Wastewater Treatment Facility (VVWTF) Treating Wastewater From This Project 4a. North Hamett Regional Treatment Facility Name of VVWTF 5a. HCDPU Owner of Downstream Sewer 4b. NC0021636 WVTF Permit No. b. 12 I® Gravity 5c. Unknown leceiving Sewer Size p Force Main Permit # of Downstream Sewer (Instruction F) 6. The origin of this wastewater is (check all that apply): ❑ Residential Subdivision ❑ Apartments/Condominiums ❑ Mobile Home Park ® School ❑ Restaurant ❑ Office 0 Retail (Stores, shopping centers) 0 Institution ❑ Hospital 0 Church ❑ Nursing Home 0 Other (specify): 7. Volume of wastewater to be allocated or permitted for this particular project: 23.880 *Do not Include future flows or previously permitted allocations % Domestic/Commercial % Industrial (Attach Description) Other (Attach Description) gallons per day 8. If the permitted flow is zero, indicate why: ❑ Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA 10-14 APPLICATION Page 4 of 6 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use j data in accordance with 15A NCAC 2T .0114 (f). 120 gal/bed/day x 199 beds = 23,880 gal/day 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) New Gravity or Additional 1 Size (inches) Length (feet) Force Main 8 104 Gravity 6 103 Gravity CI W Z 11. Summary of Pump Stations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) Z 0 Pump Station Location ID: (self chosen - as shown on plans/map for reference) •—+ Longitude: Latitude: Z 0 F.. Design Flow Operational Point Power Reliability Option (MGD) GPM �TDH 1 - permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w/MTS 0 U. Z Pump Station Location ID: (self chosen - as shown on plans/map for reference) H 2 Longitude: Latitude: L W Design Flow Power Reliability Option O. (MGD) Operational Point 1 - permanent generator w/ATS; Force Main Size Force Main Length Oi GPM @TDH 2 - portable generator w/MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ❑ Yes ® No If Yes, permit number of 2nd treatment facility : (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Permittina of Puma Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ❑ Yes ❑ No If No, complete and submit the Variance/Altemative Design Request (VADC 10-141 application and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. FTA 10-14 APPLICATION Page 5 of 6 14. Have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erosion Control Plan? Trout Buffer Waiver? Stormwater? ❑ Yes ❑ No ® N/A ® Yes ❑ No ❑ N/A ❑ Yes ❑ No ® N/A ❑ Yes ❑ No ®N/A 15. Does this project include any high priority lines (15A NCAC 02T .0402 (2)) involve aerial lines, siphons, or interference manholes)? These lines will be considered hiseh Priority and must be checked once every six months Check if Yes: ❑ and provide details: 1. Owner/Permittee's Certification: (Signature of Signing Official and Project Name) 1, Jim Roberts attest that this application for Campbell University — South Residence Hall has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all ►equired parts of this application are not completed and that if all requited supporting documentat/on and attachments am not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143- 215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 1 a. a AAA Signir Official Signature q �+jzol5 Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY U) TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T .0305 Z 0 Q2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) ▪ 1, Roy P. Lorenzen ,attest that this application for Campbell University — South Residence Hall has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other - supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed WIJdesign has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity L Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that i have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or ce►tification in any application shell be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 as well as civil penalties up to $25, 000 per violation. V 2a. Roy P. Lorenzen Professional Engineer Name 2b. Stewart Engineering Firm 2c. 421 Fayetteville Street, Suite 400 Mailing Address 2d. Raleigh City 2g. 919-886-4813 2h. 919-380-8750 Telephone Facsimile 2e. NC 2f. 27601 State Zip 2i. riorenzengstewartinc.com E-mail FTA 10-14 APPLICATION Page 6 of 6 4r Iti f1 NC PE Seal, Signature & Date State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE 06-13) Project Applicant Name: Campbell University Project Name for which flow is being requested: South Residence Hall — 23,880gpd More than one FTSE may he required for a single project if the owner of the WWTP is not responsible for ull pump stations along the route of the proposed wastewater flow I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: North Harnett Regional WWTP b. WWTP Facility Permit #: NC0021636 c. WWTP facility's permitted flow Fuquay Varina Allocated Flow Lillington Allocated Flow Angier Allocated Flow d. Estimated obligated flow not yet tributary to the WWTP FV Obligated Flow NYT Lillington Obligated Flow NYT HC Obligated Flow NYT Angier Obligated Flow NYT e. WWTP facility's actual avg. Clow FV Actual Flow Lillington Actual Flow HC Actual Flow Angier Actual Flow f. Total flow for this specific request g. Total actual and obligated flows to the facility FV Actual Avg. + Obligated Flow Lillington Actual Avg. + Obligated Flow HC Actual Avg. + Obligated Flow+ Request Angier Actual + Obligated Flow h. Percent of permitted flow used *North Harnett WWTP is being evaluated by NCDENR- DWR for planned future expansion. All flows are in MGD 5.600 MGD 2.60 MGD 1.20 MGD 1.008 MGD 1.199 MGD 0.836 MGD 0.101 MGD 0.221 MGD 0.041 MGD 4.302 MGD 1.269 MGD 0.637MGD 1.918 MGD 0.478 MGD 0.024 MGD 5.538 MGD 2.118 MGD 0.738 MGD 2.163 MGD 0.519 MGD 98.89% (Overall) Page 1 of 6 FTSF 06-1 3 I1. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated. Average Daily Approx. Not Yet Total Current Firm Flow** Current Avg. Tributary Flow Plus Pump Station Capacity,* (Firni / pf), Daily Flow. Daily Flow. Obligated Available (Name or Number) MGD MGD MGD MGD Flow Capacity*** SLS #10B 2.304 0.921 0.563 0.091 0.654 0.267 HCDPU Regional 14.4 SLS # 120 (10 000eom) 5.76 2.22 1.014 3.250 2.511 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < O. III. Certification Statement: I Steve Ward — Director of Public Utilities certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form inc ates acceptance of this wastewater flow. ? it Signing Ofircial Signature Date Page 2 of 6 FTS E 06-13 STEWART LETTER OF TRANSMITTAL TO rnipcsim ip sEP2sze- �wR FROM. i tVILLE REGION, NCDENR-DWQ Colie Crosby 225 Green Street Suite 714 STEWART Fayetteville, NC 28301 (919) 866-4796 DATE SENT VIA 09/24/2015 Mail Delivery PROJECT NUMBER PROJECT NAME C15001 Campbell University - South Residence Hall COPIES DATE DESCRIPTION 2 - Cover Letter 2 - Signed Application Form 2 - Site Maps (USGS Topographic / Street Level map) 1 - Check in the amount of $480 2 - Flow Tracking Acceptance Form For approval For review & comment C Returned for corrections EFor your use Approved as submitted E Returned after review E As requested Approved as noted C Resubmit copies for approval COMMENTS Please find the enclosed submittal package for the above referenced sewer service line addition for the Campbell University- South Residence Hall project. Please let me know if you need any additional information or have any questions. Thank you, SIG Colie Crosby Received By: 421 FAYETTEVILLE STREET MALL SUITE 400 RALEIGH, NC T 919.380.8750 27601 F 919.380.8752 STEWART September 24, 2015 Division of Water Resources Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301 NCDENR Division of Water Resources - Sewer Fast Track Application Campbell University - South Residence Hall The Campbell University South Residence Hall site is located approximately 1,200 linear feet east of the intersection of US 421 / NC 27 and Leslie Campbell Avenue along Leslie Campbell Avenue. The project is proposing an approximate 150 linear feet of 6" P.V.C. gravity sewer service from the proposed South Residence Hall building. There is an estimated 23,880 gal/day increase in flow to the existing system provided by the proposed residence hall. These values are based on 120 gal/bed/day, (from NCDENR 2T rules) for the proposed 199 beds. These services will tie into the Sanitary Sewer piping completed as part of the Early Utility Relocation Package under the Permit #WQ0037030, Campbell University Water and Sewer Utility Relocation Wastewater Collection System Extension Permit, August 6, 2015. The existing system flow will be carried downstream by a 12" Harnett County Department of Public Utilities permitted sewer and treated at the North Harnett Regional Sewer Plant. If you have any questions, feel free to contact me at your convenience. Sincerely, Colie Crosby 421 Fayetteville Street, Suite 400 Raleigh, NC 27601 P: 919-866-4796 Email: ccrosby@stewartinc.com STRONGER BY DESIGN 421 FAYETTEVILLE ST. SUITE 400 RALEIGH, NC T 919.380.8750 27601 F 919.380.8752 Z 0 i— Q cc 0 Z Z 0 lh 0_ J a a Z 0 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD 1. Owner/Permittee: la. Campbell University Full Legal Name (company, municipality, HOA, utility, etc.) Application Number: (to be completed by DWR) CEIVEtt)) SEP 2 12015 FAYETTEVI!_I_E RFGf(1NI (:3; 3oi 1 b. Jim Roberts, Vice President for Business & Treasurer Signing Official Name and Title (Please review 15A NCAC 27 .0106 (b) for authorized signing officials) 1 c. The legal entity who will own this system is: ❑ Individual ❑ Federal ❑ Municipality ❑ State/County ® Private Partnership ❑ Corporation ['Other (specify): ld. PO Box 97 Mailing Address City 1 f. NC lg. 27506 le. Buies Creek State 919-893-1240 Zip Code 1 i. N/A 1j. roberts@campbell.edu Telephone Facsimile 2. Project (Facility) Information: 2a. Campbell University — South Residence Hall Brief Project Name (permit will refer to this name) 3. Contact Person: 3a. Roy P. Lorenzen , Senior Project Manager, Stewart Engineering E-mail 2b. Hamett County Where Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 919-866-4813 3c. rlorenzen@stewartinc.com Phone Number E-mail 1. Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No.: 2. Owner is ❑ Public (skip to Item B(3)) ® Private (go to Item 2(a)) 2a. If private, applicant will be: ® Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. Hamett County Public Utilities 2b. If sold facilities owned by a (must choose one) ❑ Public Utility (Instruction D) ❑ Homeowner Assoc./Developer (Instruction E) I_ OFFICE STEWART ENGINEERING, INC. OPERATING ACCOUNT 421 FAYETTEVILLE ST. SUITE 400 RALEIGH, NC 27601 (919) 380-8750 PAY Four Hundred Eighty and 00/100 Dollars TO NCDENR c/o ENR Building 217 West Jones Street Raleigh, NC 27603 PNC BANK, N.A.-- 15-3-540 Account #: Stewart CHECK DATE 14050 September 9, 2015 AMOUNT 480.00 5/ttifelfrt Details on back. 8 FTA 10-14 APPLICATION Page 4 of Central Files: APS _ SWP 10/2/2015 Permit Number WQ0038055 ° Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer trent.allen Coastal SWRuIe Permitted Flow 23,880 Facility Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name Campbell Unibersity - South Residence Hall Location Address Owner Major/Minor Region Minor Fayetteville County Harnett Facility Contact Affiliation Owner Name Campbell University Inc Dates/Events Owner Type Non -Government Owner Affiliation Jim Roberts PO Box 97 Buies Creek NC 27506 Orig Issue 10/2/2015 Scheduled App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 9/29/2015 10/2/2015 10/2/2015 Regulated Activities Requested /Received Events Wastewater collection Additional information requested Additional information received Outfall Waterbody Name Streamlndex Number Current Class Subbasin ,. „ B � 22 • wf — ta 6,3 § • !