Loading...
HomeMy WebLinkAboutWQ0039770_Amendment Request_20210526PROTECT NARRATIVE- MODIFICATION Raleigh -Wilmington Investors, LLC previously permitted the sanitary sewer for a single-family neighborhood at 1319 Lt. Congleton Road (WQ0039770, 02/13/18). At final build -out the neighborhood will consist of 170 single family lots and amenities that is served with sanitary sewer outfalls between two (2) existing Cape Fear Public Utility Authority manholes [Sentry Oaks Pump Station (SSA-131) to the north and Intracoastal Watch PS (SSA-115) to the south]. The new owner, Clayton Properties Group, Inc., has since revised a minor portion of the development that has resulted in the need to modify the sanitary sewer network and associated permitting. The revised total flow numbers for each pump station are as follows. Sentry Oaks PS — 113 lots and amenity (41,634 gpd) and Intracoastal PS — 57 lots (20,520 gpd). The previous approved permit included 53 lots (19,080 gpd) to the Intracoastal PS. As a result, this modification only requires permitting an additional 4 lots to satisfy the site changes (1,440 gpd). Also, please note that the previous approved permit included the flow of 56 lots (20,160 gpd) to Sentry Oaks PS which will remain and not be affected by this modification. The total flow for the site, all of which is going to Mckean-Maffit Wastewater Treatment Plant, has not changed. The previously permitted gravity sewer line length was 8,0601f. The site changes have resulted in needing 8,4501f of total gravity sewer; therefore, please find that this modification includes 3901f to make up the difference. High Priority Line: Please find on Plan and Profile Sheet C-5.9 an aerial crossing that is deemed to be high priority between SSMH#7A and SSMH#7B. The crossing is achieved according to CFPUA's requirements for aerial crossings (specifications and details) and is 281f in length by way of a single stick of 8" DIP with piles and bent. I SHEET C-5.8 - ssr�r�#, TO MYRTLE GROVE ROAD I 30 I 29 28 27 26 25 24 I 23 II " I 22 I 21 I 20 19 18 17 16 O — — 15 I I I C 1 SHEET C-5. 1 1 1 , I I I N I I I I I I I I 14 13 I 12 I 11 I 10 I O I \8 I �7 I O O I O I 2 I O I SSMH#43 ISSMH#z T ' SSMH#3 ss ss ass �A--ss_ ss ss SS-.gti #3� ss� LT. CONGLETO _ w_—w w _ w ss (PIZIVAT D �WrnII1 - IIy JIL — SSMH#4 55-' S -= -w �W w W W--W�_ �W-µ-S$_S3SE-1\/"/ ssSS SS___w \ W SSMH#4B w—W� \ SS s Ss�ss SSMH#40A SSMH#41 SSMH#42 9 w I I \ �W ssss ss ssss ss m ssss ss ssssssss� w " 13 / \ 87 88 I 89 90 91 I \ O I \ �W_w�w wow_ w/ � 86 I I I I 92 I 93 I _ w—w—w w w—w w w w—w w w w w w—w_ �" / I I _-- SHEE C-5.5 WET — -- — — DETENTION 102 POND #38 \ 99 \ 3 0 62 61 60 -L -- -- �- -L -I- J-----�-- III ' I \\ WET DETENTION I I 33 1 , I I' 1 '1 CJ► 1 , \ �W� POND #363 I �I /SREET C 5.7 � O 34 i I (/ " �ZSSMSIS 0B\ 114 H ASSM� 55\ _ _ I Ss SSMH#15 \ 5$ ss ss / //�� / / � C � 5 Minn �M ss SSM u\�'�//�`/ � 1 1 0 / 35 ISSMH#5 SS s� M�� ✓/5 /M�— — ssp�� \\ \ / / 113 111 \ /MH#31 SSrym#a0G r \ \ \ M s SSMH#40G SMH 1 37 I I I 84 � 65 I I 56 I L SSMH#30 - - - - 115 / / \ \ O I I1 I 6g 13 I 55 I i I117 s I TssM 2s/ \ 39 I S' MH#21A �, 82 \ 166 O 0 40 1 1 1 1 1 r 81 SSMH#2 164 \ 53 1 123 I I 120 I 119 118 O I I 1 I I I O �' I I I I 124 O I 122 121 O 1 0 O I IF SHEET C-5.10_ 1 II _ 13OI I O 11 _— MH#40E 0' R/ ss \ I I 1 79 I I O 1 0 1 144 I' 55 ss SSMH#22C Ss �® I _ 51 I I 'SSMH#22BI 55—ss s—w—M ROAD D w SSMH#22D I �W_ — — -(PRIVATE 5 w I I 162 _ w 43 I I �I 78 71 �- __� 1 O 1 1 O 50 I 145 11 1I I I 1 11 I , I I 1 ' '1 128 O I 129 I 44 13 " ' I ' _ _ I I 161 1 77 1 II 1 1 �\ I 1 O I126 3 I 49 146 I' I' I 125 I 127 11 SSMH#21 BI I _ _ 11 SSMH#15D 130 I I 1 0 SSMH#20 I O I 147 SSMH#11 I I 48 \ W I SHEET C-5.8 \ ss 40I I —w W wow sSMH#is ss \� /'�'' O --�— I " I 136 SHEET C- ' I TRITON CT. g0 �5o R� (� 15s s ssn #,6^ SHEET C-5.9 5. 133 I SSMH#z O s J — O 95/5 H22 #18 SS�Ss \ _ ssMH#,� < \ \ss \ �/ -_� ' _3\3 \\ SHEET C-5.4#9/ \ \ 135 II I1I II O134 SSMH /6� / \ \157 / , Suess SSMH#23 \SMH#24 2 I / 7// SSMH#8 I I WET DETENTION II POND #1 I l j I 171 I WET DETENTION N I I I POND #2 I I I I I I � I I I I I I ISS4H#7B � SS H#7A i ss� 55 SSMH#6 ss/ 1 EX-SSMH �Q 1� rTQ1 � 1 GRAPHIC SCALE Kw W Call � ym d� 0 50 100 200 400 ��T� SCALE: 1 "=100' 0 N 0 N 0 N o (M V N N (A (M N (O uj w Z) 0 w Z w � U) U ui 00 w 00 a U U w a U a U (n Z 0 a a O g z o z 0 U > W LU w U) w CU � H W V� O Q�N O Q 0 H Z F� 2 0 C� v O LL z F__ z �D N I� "' F>� N J U w � M ` 00 N OHO Z N Q �oU w O w Z N z - - °U Z � � O W � hr--I H O H OrTl M--�i W�U 0 o U o z N0a0 O o- Q z O LL F- 00 0 U � � 9 Z_ O i..iJJw 6i_jL9 d UUaIa oU)000 SEAL \\00111111/ CARG�����''/ ° S/O 9 - 0362 5 mac; °°FNGINE� /s1'10pHER\N \\ 1 06123120 C - 0 • PEI JOB#: 16384.PE SSMH #6 10+00 SS EXISTINGT \ 35' UTILITY EASEMENT SANITARY WET DETENTION SEWER POND #1 FOREBAY ---------------- co \ � 112+0 \ I I s � ss SSMH #7A �L _ I I II SSMH #7B �� / ss ss SW 15+pp / ss 35' UTILITY / ss 1s+ EASEMENT / -- // ss SSMH #8 ` ' ss FOR CROSSING CONTRACTOR SHALL s +00 PROVIDE DIP (SINGLE STICK OF PIPE) — ACCORDING TO CFPUA PILE & BENT / �� ��= ` ss 17+6 -03 DETAIL. SEE DETAILS. — I I / SSMH #9 I / 0°0000 /� N °oo°o°000000 0000. \ N / I I ° I \ ° °°°°°°°°°0°° I I °°° 0000°°00°000 \ � LO J00000\ N ° SEE RIGHT SEWER 1 - PLAN VIEW HORIZONTAL SCALE: 1 "=50' 35 30 25 20 15 10 c u V x LL 6: M O o M z ZZ) PROPOSED + r � m �* �Q EXISTING GRADE (TYP.) < =� (nH�» c'0 00 0 00 � M 7: 0 Z Z 7 IT CONTRACTOR SHALL PROVIDE DIP (SINGLE STICK OF PIPE) ACCORDING TO CFPUA PILE BENT DETAIL (SEE DETAIL) 318 LF OF 8 IN. C-900 PVC (DR 43 LF OF 8 IN. C-900 PVC (DR-18) @ 0.40% 0oo oo �°~ = �2i» U)crzz �U�zz I ; -------- 246 LF OF 8 IN. C 00 VC (D -18) @ 0.40% co N00 = ��2E U)U)Ezz ^^ IN CD _ _ U � cn CIO c c N N Nz_z_ Fllo --zp - N°'~ 2> C-9 127 0 PVC LF O (DR 8 N. 18)@ 0.40% 18) 0.40% N OM N <2E» O28LFFo�100zp 8IN.DIP @0.40% =—NZp U)U)ERzz O O co CO CO M M N 00 T7 Co O N co N N N N N 0')O N N rn N 10+00 11+00 12+00 13+00 14+00 SERVICE NOTE: 1. CONTRACTOR SHALL INSTALL ONE (1) 1-INCH WATER SERVICE PER LOT AND ONE (1) 4-INCH SEWER SERVICE PER LOT. CAPE FEAR PUBLIC UTILITY AUTHORITY STANDARD SEWER NOTES: 1. SEWER GUARDS REQUIRED AT ALL MANHOLES. STAINLESS STEEL SEWER GUARDS REQUIRED AT MANHOLES LOCATED IN TRAFFIC AREAS. 2. WATER AND SEWER SERVICES SHALL BE PERPENDICULAR TO MAIN AND TERMINATE AT R/W LINE. SEWER SERVICES IN CUL-DE-SACS ARE REQUIRED TO BE PERPENDICULAR, OR MUST ORIGINATE IN END OF LINE MANHOLE AND TERMINATE AT RIGHT-OF-WAY LINE. 3. ALL SERVICES TYING INTO DUCTILE IRON MAINS SHALL BE CONSTRUCTED OF CLASS 50, DIP, WITH PROTECTO 401 CERAMIC EPDXY LINING. 4. MINIMUM 10' UTILITIES EASEMENT PROVIDED ALONG THE FRONTAGE OF ALL LOTS AND AS SHOWN FOR NEW DEVELOPMENTS. 5. NO FLEXIBLE COUPLINGS SHALL BE USED. 6. ALL STAINLESS STEEL FASTENERS SHALL BE 316. 7. CLEANOUTS SHALL BE LOCATED A MINIMUM OF 12 FEET FROM ALL PROPERTY CORNERS. WATER METER BOXES ARE TO BE A MINIMUM OF 5 FEET FROM THE PROPERTY CORNER. SEWER 1 - PROFILE VIEW HORIZONTAL SCALE: 1 "=50' VERTICAL SCALE: 1 "=5' 15+00 16+00 UTILITY NOTES: (NCAC 15A.02T.0305 / T1 5A. 1 8C.0906) 1. WATER MAINS SHALL BE LAID SO AS TO PROVIDE A MINIMUM HORIZONTAL SEPARATION OF 10 FEET FROM SEWERS. IF CONDITIONS EXIST SUCH THAT THIS SEPARATION CANNOT BE ACHIEVED, THE WATER MAIN CAN BE INSTALLED AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER, EITHER IN A SEPARATE TRENCH, OR IN THE SAME TRENCH ON A BENCH OF UNDISTURBED EARTH. 2. WHEN CROSSING A WATER MAIN OVER A SEWER, THE WATER MAIN SHALL BE LAID AT LEAST 18 INCHES ABOVE THE SEWER. IF CONDITIONS EXIST SUCH THAT THIS SEPARATION CANNOT BE ACHIEVED, BOTH THE WATER MAIN AND SEWER SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE WITH JOINTS THAT MEET WATER MAIN STANDARDS. THE DUCTILE IRON PIPE SHALL EXTEND 10 FEET ON EACH SIDE OF THE CROSSING WITH A SECTION OF WATER MAIN PIPE CENTERED ON THE CROSSING. 3. CROSSING A WATER MAIN UNDER A SEWER. WHENEVER IT IS NECESSARY FOR A WATER MAIN TO CROSS UNDER A SEWER, BOTH THE WATER MAIN AND THE SEWER SHALL BE CONSTRUCTED OF FERROUS MATERIALS AND WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE POINT OF CROSSING. A SECTION OF WATER MAIN PIPE SHALL BE CENTERED AT THE POINT OF CROSSING. 4. WHERE VERTICAL CLEARANCE IS LESS THAN 24" BETWEEN SANITARY SEWER AND STORM DRAIN, SANITARY SEWER SHALL BE DUCTILE IRON PIPE FOR A MINIMUM OF 10, EITHER SIDE OF CROSSING AND STORM DRAIN SHALL BE RC PIPE. 5. WHERE VERTICAL CLEARANCE IS LESS THAN 18" BETWEEN WATER MAIN AND STORM DRAIN, WATER MAIN SHALL BE DUCTILE IRON PIPE FOR A MINIMUM OF 10' EITHER SIDE OF CROSSING AND STORM DRAIN SHALL BE RC PIPE. 17+00 SEE SHEET C-5.6 50' ROW \ I / / SSMH #16 \\\N SSMH 422 35' UTILITY I \\\ (1) 8" MJ 22.5° BEND EASEMENT \N \ EASEMENT — _j O W 1 00 11+00 12+00 I�? 1 +0°SS / 4,1 SS—�— SS ISS SSA SS—� SS ss +oo ss�/ 22\ SSMH #9 r(,�7 SSMH #10 SSMH #23 +I 00000 I I SSMH #9 oo°° oo o 0000 � SEWER 2 -PLAN VIEW SEWER 3 - PLAN VIEW HORIZONTAL SCALE: 1 "=50' HORIZONTAL SCALE: 1 "=50' 35 35 30 30 25 25 GRADE (TYP.) 20 20 15 15 10 10 N H a D _ O C > `f.. z 5 5 Lr N EXISTING GRADE (TYP.) PROPOSED GRADE I (TYP.) 36" STORM SEWER 24 LF MIN. DIP CENTERED ON STORM DRAIN C-900 PVC (DR-18) 8' 8 IN. 218 LF (TOTAL) OF -00 cli NN �� 22 o �� U)U) O M coN O N O N N �2 �2 e + O I- II O N II II II N Z Z > > >FIL N + C O II II F Z Z 2 II N77 > > U) 1 U) C/) O N N N LO M (q N r N— N 00 00 OR N N N 0) OR O N 10+00 11+00 SEWER 2 - PROFILE VIEW HORIZONTAL SCALE: 1 "=50' VERTICAL SCALE: 1 "=5' 12+00 35 30 25 20 15 10 61 35 25 20 15 10 Lq N PROPOSED GRADE (TYP.) EXISTING GRADE (TYP.) 243 LF L 00 PVC DR 18 0.45% 24" STORM SEWER 2 U) c/)c� O 04 ag>>> _ U) cn N f- N 00 Lr) M N N 00 O N N N 00 N 10+00 11+00 12+00 SEWER 3 - PROFILE VIEW HORIZONTAL SCALE: 1 "=50' VERTICAL SCALE: 1 "=5' 35 30 25 20 15 �r � 102 LO ss�R M co N M M � N II II � n N Z Z O a > > > U) Z Z Z 5 C U O U O # W KmwwMft bd I o 50 10o GRAPHICooSCALE 400 w II More d� SCALE: 1 "=100' F� z 0 > W CU \'0 M--1 U� co c N W o �WLn Q�N z O Q WU 2 0 (h U ^ O u_ Z W z CIA w U � - N 000 Z N Q � o U W W Noy Z z O w I a1 `.. v J H Q � W�U v 40 �Iv�U4Z °o o oo2U2 co V a U O C� o � Q ~ > > Z 00 O o J J 0 J}z0 Z (D (D 10 U Da�noLu WgoJ >Z o > ZZ> O U J J W Q W J > U Q 01_LL2' 0(n000 SEAL \\\\w H 11 i i iiii i .. CAR p�/N \\\� / S1041 e 9 S - 0362 5 � °GIN'; /'s'OpW \\ iNER 06123120 C-5,99 PEI JOB#: 16384.PE iU- n Ox12"x4' (MIN) CLASS 2.5 CCA TREATED BEAM SALT WATER CONTACT 1"0 SST. U-BOLT WITH 3"x3"x1/8" SST. SQ. FLAT WASHER & SST. LOC--NUT r-1/8'x4" NYLON STRAP COMPLETE AROUND PIPE H A SNAP LOCK 401 PROTECTO MANHOLE SEE SECTION A -A CERAMIC LINED DIP SEWER THIS SHEET MAIN (CL 54) SET ON GRADE, AS PER PLANS. PILE AND BENT PLAN NOT TO SCALE NOTES: ES AND PILE DRIVING SHALL CONFORM TO NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES, JANUARY 20OZ SECTIONS 445, 450, 1082-2 & 1084-2. 2. CENTERLINE OF BOLTS TO BE A MINIMUM OF 3" FROM OUTSIDE EDGE OF TIMBER. BOLTS TO BE A MINIMUM OF 3" CENTERLINE TO CENTERLINE. 3. ALL STAINLESS STEEL SHALL BE 316. STAINLESS STRAP TO BE COLD FORMED. 4. PILE SHALL NOT OBSTRUCT FLOW OR CAUSE EROSION OF DITCH/STREAM BANK. 5. MIN. CLASS 54 DIP -ENGINEER MUST DESIGN LOADING. S. DESIGN SHALL BE APPROVED BY CFPUA. SEE SECTION A -A L MANHOLE INSET, THIS SHEET_ — SNAP LOCK 401 PROTECTO CERAMIC LINED DIP SEWER MAIN (CL 54) scr ON GRADE, AS PER PLANS. - I I 8 ■X$XS (MIN.) / / SPACING SET BY < I �r� TREATED PILE 5 PIPE LAYING LENGTH, SALT WATER I NOT TO EXCEED , 5 CONTACT 18' WITHOUT APPROVAL MAX., FROM THE CFPUA���`\� \fit ,x PILE AND BENT SECTION A -A NOT TO SCALE FORCE MAIN PIPE 1"0 SST. U-BOLT WITH 3%3"0/8" SST SQ. FLAT WASHER & SST. LOC-NUT 2' 2'i 1/8'x4" NYLON STRAP COMPLETE AROUND PIPE it II It :;rWASHIER (2) 5/8" STAINLESS I I ( IIt I STEEL BOLTS WITH 2"x2"x1 /8" SST. SO. II II AND LOCK NUTS 2"x12" CLASS 2.5 2"x12"x V (MIN) CLASS CCA TREATED 2.5 CCA TREATED BEAM BEAM SALT SALT WATER CONTACT WATER CONTACT 8'x8'x8' (MIN) GLASS 2.5 CCA TREATED PILE PILE AND BENT SECTION B-B SALT WATER CONTACT NOT TO SCALE 1"0 SST. U-BOLT WITH 3"x3"x1/8" 1.0' MAX. SST. SQ. FLAT WASHER & LOC-NUT " COMPLETE AROUND PIPE 1/8x4" NYLON STRAP 2"x12'x4' (MIN) CLASS W (2) 5/8" STAINLESS STEEL BOLTS WITH 2.5 CCA TREATED BEAM2-x2"x1/8" SST SO. WASHER AND LOCK NUTS SALT WATER CONTACT8'x8'x8' (MIN) CLASS2"x12%4' (MIN) CLASS 2.5 CCA 2.5 CCA TREATED PILETREATED BEAM SALT WATER CONTACT SALT WATER CONTACT PILE AND BENT SECTION A -A INSET NOT TO SCALE PILE AND BENT DETAIL SD-20 NOT TO SCALE TRACER HARE SHALL PENETRATE VALVE BOX APPROXIMATELY 6" BELOW GRADE WITH MIN. 2' EXTRA LENGTH COILED IN THE VALVE BOX TRACER WIRE LOCATOR BOX (1,000' MAX. GATE VALVE TRACER WIRE FORCE MAIN PIPE EXISTING GRADE VALVE BOX DUCTILE IRON TEE FITTING. ATTACH TRACER WIRE USING DUCT TAPE (TYP) ----DUCTILE IRON CROSS ° FITTING (ATTACH TRACER WIRE USING DUCT TAPE) ATTACH TRACER WIRE TO FITTING USING DUCT TAPE (TYP.) 11.�TTRACER WIRE SHALL BE #10 COPPER SOLID CORE COPPER WIRE WITH GAS AND OIL RESISTANT INSULATION. 2. WIRE SHALL BE STRAPPED TO ALL PVC FORCE MAIN PIPING WITH DUCT TAPE AT 12 FOOT INTERVALS ALONG THE PIPE. 3. SECURE WIRE TO ALL TEE AND CROSS FITTINGS WITH DUCT TAPE. 4. ALL SPLICES IN THE WIRE SHALL BE MADE WITH 3M DBR DIRECT BURY SPLICE KIT AN UNDERGROUND RATED, WATERTIGHT, AND APPROVED SPLICE CONNECTOR OR APPROVED EQUAL TRACER WIRE DETAIL SD-21 NOT TO SCALE INSET STORM NOT TO SCALE \ SEWER \�\ i t t � t FORM CRADLE, \ FILL VOID WITH A, 3000 PSI (MIN) CONCRETE a ,. •° $. STORM , SEE INSET f MIN, SEWER \ DIA. OF\ STORM SEWER \ PIPE GATE VALVES REQUIRED ON EITHER SIDE OF THE CROSSING IF TOTAL VERTICAL OFFSET FROM EXISTING PIPE ALIGNMENT IS GREATER THAN 24" 45 BEND I r■rIr rIrrllrrrrlr� ' __ I 1 SANITARY SEWER PIPE 3'MIN. #COVER 8" MIN. 57 STONE BEDDING AS NEEDED TO STABILIZE FOUNDATION NOTE: NO JOINTS ON STORM DRAIN PIPES ARE ALLOWED BETWEEN PIERS UNLESS JOINTS ARE BELL AND SPIGOT COLLAR WITH FABRIC WRAP. STORM SEWER .�- 57 STONE CONCRETE FOOTING/PIER (OR CONC. BLOCK FILLED WITH CONC.) SANITARY SEWER 57 STONE BEDDING AS NEEDED TO STABILIZE FOUNDATION 6" MIN. FROM EDGE OF PIPE THE FOLLOWING MUST BE FOLLOWEr} IN ,]BE CASES OF GRAVITY SEWER UNDER -STORM DRAIN: • A SEPARATION OF LESS THAN 12" BETWEEN STORM DRAIN AND GRAVITY SEWER, STORM DRAIN MUST BE BRIDGED. • A SEPARATION OF 12"TO LESS THAN 24"BETWEEN STORM DRAIN AND GRAVITY SEWER, GRAVITY SEWER CAN BE DIP OR STORM DRAIN CAN BE BRIDGED. (PER DWR REGULATIONS) • A SEPARATION OF 24' OR GREATER BETWEEN STORM DRAIN AND GRAVITY SEWER REQUIRES NO BRIDGING OR DIP. STRUCTURAL BRIDGING DETAIL FOR STORMWATER OVER GRAVITY SEWER INSTALLATIONS WITH LESS THAN 12" SEPARATION NOT TO SCALE 10' MIN. . i--[-10' MIN. V-LOWER THRUST BLOCKS REQUIRED MEG-A-LUGS ON EITHER SIDE OF THE CROSSING THROUGHOUT IF TOTAL VERTICAL OFFSET FROM EXISTING PIPE ALIGNMENT IS GREATER THAN 24' NOTE: USE D.I.P. (CL50 OR BETTER) FORCE MAIN DITCH AND STORM DRAIN CROSSING NOT TO SCALE REV- DESCRIPTION: DATE: 1 ADDED NOTES TO THE STRUCTURAL BRIDGING DETAIL 03111/15 2 Revised Tracer Wire Detail 10120/15 3 Revised Farce Main Ditch and Storm Drain Crossing Detail 02115/16 GENERAL- NOTES: 1. NO EXCAVATED MATERIAL SHALL BE PLACED IN ANY STREAM, DITCH OR DRAINAGE -WAY. 2. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES BEFORE ANY CONSTRUCTION BEGINS. 3. THE CONTRACTOR IS RESPONSIBLE FOR TEMPORARY SEDIMENT AND EROSION CONTROL MEASURES WHILE CONSTRUCTION IS IN PROGRESS. 4. THE CONTRACTOR IS RESPONSIBLE FOR STABILIZATION OF ALL DISTURBED AREAS. 5. THE CONTRACTOR IS RESPONSIBLE FOR LAY DOWN AND STOCKPILE AREAS (TO ARRANGE AND ENSURE COMPLIANCE WITH ALL LOCAL AND STATE REGULATIONS). THE DETAILS SHOWN HEREON SUPERCEDE CFPUA WRITTEN TECHNICAL SPECIFICATIONS VERSIONS 1.00 -1.04 CFPUA SANITARY SEWER STANDARD DETAILS CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NO 2M3 OFFICE: (910)332-6560 Ste ardship. Sustainabildy. Sermce. DATE: 1/9112 SCALE NIA DRAWN BY, CFPUA CHECKED BY: CFPUA PROJECT NO_ SHEET NO: SSD-3 z O W IY Vaa r-� Ili o� W Wo OWN �ZU � o O ~ � V O IL z Why � M_ z to Gri V� U r a �-r a d- \40 �00 Z�v) o o� A� W 'b Z QQ 5 V z �W z o� U% Z O o w� Z w Qwo Q U ZZ A<_0u ZQQV z O Q I" N O LL 00 p g z aW (9° W dZWLu c� W .. a 0 �J LL zwZ.r li1ZZY 4 iL j!23:0 (� r-�W* u Ll UaLLW �rADOU SEAL "�- - 6.5 PEI JOB#: 16384.PE