Loading...
HomeMy WebLinkAboutSW1210503_Soils/Geotechnical Report_20210526 Geotechnical Investigation Hot Springs(Duke Energy- URE GreenSmith) Off Andrews Avenue South Hot Springs, Madison County, North Carolina ECA Project No.V1440 PREPARED BY: SUBMITTED TO: Environmental Corporation of America United RenewableEnergy, LLC 1375 Union Hill Industrial Court, Suite A 5895 Shiloh Road, Suite 104 Alpharetta, GA 30004 Alpharetta, GA 30005 Atlanta, GA -Corporate Headquarters | 1375 Union Hill Industrial Court, Alpharetta,GA 30004 | (770)667-2040| www.eca-usa.com September 9, 2019 United Renewable Energy, LLC 5895 Shiloh Road, Suite 104 Alpharetta, GA 30005 Attention:Mr. Neal Erickson Subject:Report of Geotechnical Investigation Hot Springs(Duke Energy-URE Green Smith) Off Andrews Avenue South Hot Springs, Madison County, North Carolina ECA Project No. V1440 Dear Mr. Erickson: Environmental Corporation of America (ECA) is pleased to submit this report of our geotechnical investigation for the proposed project. Our services were provided as authorized by United Renewable Energy, LLC,via approved proposal dated August 12,2019. This report presents a review of the information provided to us, a description of the site and subsurface conditions, and our recommendations. The appendices contain a Site Location Map, Boring Location Plan, Boring Logs,Laboratory Testing Results, and Laboratoryand Field Electrical Test data. Purpose and Scope of Work The purpose of this exploration was to obtain specific subsurface data at the site and to provide geotechnical related design parameters and construction recommendations for the proposed solar panel farm development. Our scope of work included the following: Eight(8)soil boringsweredrilled to depthsranging from 8to 22feet below ground surface (bgs). Figure 1 shows aSite Location Map. Figure 2 showsthe Boring Location Plan with approximate boring locations.Standard Penetration Tests (SPTs) were conducted to obtain soil samples and SPT N-values, in accordance with ASTM D-1586. The depth to groundwater, if any, was measured in the boringsafter drilling was completed. Atlanta, GA -Corporate Headquarters | 1375 Union Hill Industrial Court, Alpharetta,GA 30004 | (770)667-2040| www.eca-usa.com Mr. Neal Erickson Page 2 Naturalmoisturecontent(WC)tests were performed on a selected numberof N soilsamples in accordancewithASTM D-2216. Unconfined compressive strength (q)index tests were performed using the u pocket penetrometer testor thespring tester test(wheneverpossible). Soil index propertytesting(Liquid limit, plastic limit,plasticity index,-200 sieve and soil classification) were performed on aselectednumber of soil samples in accordancewith ASTM D-4318,ASTM D-1140,and ASTM D-2487. Fieldand laboratoryearthelectrical resistivity (ER) were measured for the existing soilin accordance with ASTM G-57. Analytical soiltesting(pH, sulfatesandchlorides)wasconducted in accordance with wet chemistry methods 9045-D and 9056-A. Thermal conductivity testing of soil and rock were performed in accordance with ASTM D-5334. The soilsampleswere visually classified in accordance with ASTM D-2488 and a boring log was prepared.The soil conditions were evaluated by a registered professional engineer and this geotechnical report was prepared with our recommendations. Wehave recommendeddesign parameters and settlements based on the SPT N-values, lab test results, examination of the soil samples,andour experience with similar soil conditions and structures. Project Information The current project considers the development of a14-acresolar panel farm. We were provided with apreliminary layout of the panel locationswithin the proposed lotprepared by United Renewable Energy anddatedJuly 8, 2019. In general, the proposed site is located within hillyterrain withsurface elevations between 1,400 and 1,600 feet Above MeanSea Level (AMSL) within the solar farm development footprint. The ground surface within the proposed development is mostly grass covered. Atlanta, GA -Corporate Headquarters | 1375 Union Hill Industrial Court, Alpharetta,GA 30004 | (770)667-2040| www.eca-usa.com Mr. Neal Erickson Page 3 Field Drilling Work ndth The fieldwork was conducted between the 22and 27of August of 2019. The borings were located within easily accessible areas.Information obtained from the boringswas used to help us evaluate the subsurface conditions and to assist in formulating foundation recommendations. The site was not staked at the time of our field visit. Borings were markedon theparcelby ECA personnel. Subsurface Soil Conditions(All Borings) The subsurface conditions for the proposed development were explored with eight(8)soil boringsto depthsranging from 8to22feet below ground surface (bgs)anddrilled approximately as shown on Figure 2. Boring B-1: From ground surface to the full depth drilled 12.5feet bgs,soils encountered consistedof loose clayey Sand (SC) andstiff to very stiff plastic sandy Silt with clay(ML) tothe explored depth of 12.5 feet. Auger Refusal was encounteredat 12.5 feet.The N-values are shown on the attached boring log and ranged from 7 to 19blows per foot (bpf). Natural moisture content (WC) measurements were conducted on selected soil samplesand ranged from 22.3% N to 30.0%.Unconfined compressive strengthmeasurementsof 3.0 to 3.5 tons per square foot (tsf) werereported using the pocket penetrometer test withintheupper 10feet. Boring B-2: From ground surface to the full depth drilled16feet bgs,soils encountered consisted of medium dense to very stiff sandy Clay (CL) with trace amounts of rock fragments to an approximate depth of 6feet, underlain by sandy Silt with clay (ML) to anapproximate depth of 13.5 feet, underlain byWeathered Rock fragments manually described as very compact dense silty Sand(SM)to the explored depthof 16feet. Auger Refusal was encounteredat 16feet.The N-values are shown on the attached boring log and ranged from 7 to over 50bpf.Natural moisture content (WC) measurements ranged from 12.3% to 19.1%.An unconfined N compressive strengthmeasurementof 4.5tsfwasreported using the pocket penetrometer at a depth of 6feet. Boring B-3: From ground surface to the full depth drilled 13feet bgs,soils encountered consisted of loose clayey Sand/sandy Clay (SC-CL) to an approximate depth of 3.5 feet, underlain by very stiff to hard sandy Siltwith clay (ML) with trace amounts of rock fragments to the refusaldepth of 13feet.The N-values are shownon the attached boring log and ranged from 9to 34bpf. Natural moisture content(WC) measurements ranged from 21.4% to 21.8%.Unconfined N compressive strengthmeasurementsof 3.0to 4.0tsf werereported using the pocket penetrometer testwithinthe upper6feet. Boring B-4: From ground surface to the fulldepth drilled 12.5feetbgs,soils encountered consistedof soft to hard sandy Silt with clay (ML) with trace amounts of rock fragments to the refusaldepth of 12.5feet.The N-values are shown on theattached boring log and ranged from 4 to 35bpf.Naturalmoisture content (WC) measurements ranged from13.1% to 17.8%. N Atlanta, GA -Corporate Headquarters | 1375 Union Hill Industrial Court, Alpharetta,GA 30004 | (770)667-2040| www.eca-usa.com Mr. Neal Erickson Page 4 Boring B-5: From ground surface to the full depth drilled 16feet bgs,soils encountered consisted of medium dense to very hard sandy Silt with clay (ML) and very stiff gravelly/sandy Clay(CL) to an approximate depth of 13.5 feet, underlain by very compact dense silty Sand(SM) with trace amounts of clay to the refusaldepth of 16feet.The N-values are shownon the attached boring log and ranged from 5to over 50bpf.Natural moisture content (WC) measurements N ranged from 24.9% to 29.7%.An unconfined compressive strengthmeasurement of 2.0tsfwas reported using the pocket penetrometer at a depth of 3.5feet. Boring B-7: From ground surface to the full depth drilled 22feet bgs,soils encountered consisted ofvery stiff sandy Silt with clay (ML) to an approximate depth of 13.5feet, underlain by Weathered Rock fragmentsmanually described as very compact dense silty Gravel (GM)to the refusaldepth of 22feet.The N-values are shownon the attached boring logand ranged from 18 to over 50bpf.Natural moisture content (WC) measurements ranged from 10.2% to 24.2%.An N unconfined compressive strengthmeasurement of 4.5tsfwasreported using the pocket penetrometer at a depth of 3.5feet. Boring B-8:From ground surface to the full depth drilled 8feet bgs,soils encountered consisted of medium dense to very hard sandy Silt with clay (ML).The N-values are shown on the attached boring log and ranged from6to over 50bpf.Anaturalmoisture content (WC) N measurementof 29.2%was reported at 3.5 feet. Boring B-9:From ground surface to the full depth drilled 8.5feet bgs,soils encountered consistedof medium dense sandy Silt with clay (ML)with trace amounts of rock fragments to an approximate depth of 6 feet, underlain by very compact dense silty Sand (SM) to the refusal depth of 8.5feet.The N-values are shown on the attached boring log and ranged from 7to 58 bpf.Anatural moisture content (WC) measurementof 12.7%was reported at 3.5 feet. N The table below presents a summary of the soil testing index properties performed on selected soil samples at differentboring and depthlocations. Sample WCSoil N Boring LLPLPI-200 Sieve No. (%)Classification No. (Depth) ASTM D-2216ASTM D-4318ASTM D-1140ASTM D-2487 B-11(3.5’)30.041261567.0ML B-22(3.5’)19.141182352.1CL B-54(13.5’)11.2NP34.0SM N Q N Q B-73(6’)23.347301771.7ML Notes:WC=Natural moisturecontent(asdeterminedby ECA)LL=liquid limit, PL=plastic N limit, PI=plasticity index, NP=nonplastic soil. Atlanta, GA -Corporate Headquarters | 1375 Union Hill Industrial Court, Alpharetta,GA 30004 | (770)667-2040| www.eca-usa.com Mr. Neal Erickson Page 5 The table below presents the auger refusal depths encountered at the site per boring. Boring No.Auger Refusal Depth(feet) Boring B-112.5 Boring B-216 Boring B-313 BoringB-412.5 Boring B-516 Boring B-722 Boring B-88 Boring B-98.5 Groundwater Level Condition Atthe time of drilling (ATD), agroundwater level wasnot encounteredwithin the depths drilled. Itshould benoted that groundwater level observationsmade within mostlycohesive soils during drilling could be misleading. It should be anticipatedthat thegroundwater level will fluctuate due toseasonal climatic changes during the year. To determine actual groundwater level measurements, groundwaterlevels should be measuredusing observation wells installed for prolonged periods. Foundation Construction Recommendations The subsurface conditions are suitable for supportof the anticipated bearing anduplift loads using a shallow foundation system.Our analysis indicates thatthe existing soilsarecapable of a maximum netallowable soil bearing pressure (q)of 2,500pounds per squarefoot (psf)at a ALL minimum depthof foundation (D) of 2feetbelow existinggrade elevation.Total and differential f settlement should be less than 1-inch and 0.5-inch, respectively.The proposed foundationshould bear within the existing sandy silt with claysoil(ML). A safety factor(SF)of 3,awet soilunit weight () of 115pcf, and a minimum foundation wet width (B) of 3feetwere considered for soil bearing computations.The provided allowablesoil bearing pressureassumes the bottom of excavationis stableand must be proof rolled and observedbefore any concrete placement, as described in our Fill Placement section. As an alternativeto the shallow foundationsystem, the project designer may consider using a deep foundationsystem. Theproposedsolar farm system may also be supported using helical piles. The helical pile system should be installedthru the existingresidualmaterial,down to auger refusal depth and embedded into the existing weathered rock an estimated length of atleast 4feet. Atlanta, GA -Corporate Headquarters | 1375 Union Hill Industrial Court, Alpharetta,GA 30004 | (770)667-2040| www.eca-usa.com Mr. Neal Erickson Page 6 Concrete Foundation Slab-Proposed Containers Before any concrete placement ECA strongly recommends performing asoilundercut approximately 2feetdeepwithin the locationof the proposal concrete slabfoundation. The proposed excavation should be extendedlaterally approximately 1-footoutside the perimeter of the proposed foundationslab.The proposed excavation should be backfilledusing selected material, as described in our Fill Placement Section. For the designoftheproposedconcrete slabfoundation,the structural engineer may consider a modulus of subgradereaction (k)of85pounds per cubic inch (pci), for concrete foundation s slabs constructed over compactedengineered fill. Due to the existence of plastic soils within thearea,we strongly recommend the use of a vapor barrier under aconcrete foundation slab. The purposeof the vapor barrier is to prevent water migration into andthrough the concrete slab.Thepresence of such water may deteriorate the capacity of the steel reinforcementon foundations and slabs. Due to the existingsite topography, the proposed concrete foundation slab would be located near the crest of an existing slope(Boring B-1 location).The projectsite designer may need to consider areasonablefoundation setback distance as described in Figure 4. Soil Site Class Based on our site evaluation and the information provided by the International Building Code (2012), to perform a dynamicanalysis,the clientsdesign engineer should consider that the soils at the site fall underaStiff Soil Profile and Site Class D. Fill Placement Selected materials for fill,unless otherwise specified, should consist of essentially granular material (GM, GP, GM, GC, SW, SP or SM Unified Soil Classification System); A-2-4or better, AASHTO Classification, as approved by the Project Geotechnical Engineer.In-situ soils should not be usedas backfill.These should be free from vegetationand should not contain rocks greater than 6 inches in size. The amount of fill required forthis project depends on the planned final grades. Any fill or backfill required to attain finished grade should be placed in layers not exceeding 8 to 10-inch thick lifts and compacted to not less than 95% of the Modified Proctor Maximum drydensity, as determined by method (ASTM D-1557). Under sidewalks and green areas compactionlevel attained shouldnot be less than 90% of the Modified Proctor Maximum drydensity. The soil moisture content should be close to the optimum moisture content. All required fill should meet the specified compaction criteria. Atlanta, GA -Corporate Headquarters | 1375 Union Hill Industrial Court, Alpharetta,GA 30004 | (770)667-2040| www.eca-usa.com Mr. Neal Erickson Page 7 Field density tests should be conducted at routine intervals as the fill is being placed to verify that adequate compaction is achieved.Prior to placing any new fill, any soft or loose near surface soils should be removed andthe area Proof-Rolled with a heavy vehicle or a heavy compaction roller to confirm that any unsuitable soil conditions have been discovered. Foundation Excavations A groundwater level was not encounteredwithin any of the borings drilled at the site. To avoid softening of the shallow soils exposed at the foundation bearing level, excavations should not be left open for extended periods, prior to placing reinforcing steel and concrete.If rain or freezing weather is expected, excavations should not be completed. Leaving the excavations at least 1- foot above final grade should protect thebearing soils from deterioration. If the excavation must remain open overnightor if rainfall becomes imminent while the bearing soils are exposed, we recommend that a2 to 4-inch thick "mud-mat" of "lean" (2,000 psi) concrete be placed on the bearing soils before the placement of reinforcing steel. Ifthe bearing soils aresoftened by surface water intrusion or exposure, the softened soils must be removed from the foundation excavation bottom immediately prior to placement of concrete. Electrical Resistivity Tests The following tables present a summary of the field and laboratorytesting results as requested by the client. Field Electrical Resistivity Tests ! The field testing was performed in accordance with ASTM G-57 and using a Ground Resistance Tester(AEMC Instrument, Model 4620) with array line with probe spacingsof2, 4, 8, 16, 25, and 40 feet. Two (2) different array lines were tested in the field.Thearray lineswithinthe proposed project area were located inthenorth-southand east-west directions.Thetable belowpresents theresult of thefield resistivity testperformed at the site. Figure 3showstheEarth Resistivity testlines location plan.Thefielddata obtained isshown in AppendixC. FieldEarth Resistivity Test No.Test DateDepth (feet) (Ohms-cm) Ground surface #18/19/201955,814 (east-west) Ground surface #28/19/201957,062 (north-south) Atlanta, GA -Corporate Headquarters | 1375 Union Hill Industrial Court, Alpharetta,GA 30004 | (770)667-2040| www.eca-usa.com Mr. Neal Erickson Page 8 Laboratory Electrical ResistivityTests The table below presents the result of a laboratory electricalresistivitytest performed on soil samplesobtained during drilling operations. The laboratory testswere performed in accordance with ASTM G-57 and usingaSoilResistivity Meter(Tinker & Rasor Instrument, Model SR-2). The laboratory test data obtained is shown inAppendix C. Test No.Sample DepthAverage Resistivity Test Date (Numberof Tests)(feet)(Ohms-cm) #1(4)0-88/29/201944,184 #2(4)0-88/30/201943,301 Analytical Testing Results(pH,Chloride and Sulfate) The table below shows the laboratorytest resultsfor selected soil samples. Chloride(Dry)Sulfate(Dry) Sample No.Boring No.pH mg/kgmg/kg 115.59NDND 285.02NDND 375.10NDND 435.30NDND ND=Not detected. The detailed chemical test report is shownin Appendix D. Thermal Conductivity Test The table below shows the resultsfor the soil thermal resistivitytestperformed on grab soil samples from Borings B-1 and B-3. Reported Soil Thermal Resistivity Sample No.Moisture Content (%) °C·cm/W 113.755.60 215.950.84 317.947.98 419.844.12 The detailed thermal conductivitytestreport is shown in Appendix D. Basis for Recommendations The subsurface conditions encountered at the boring locationsare shown on the Boring Logsin Appendix B. This Boring Logsrepresentour interpretation of the subsurface conditions based on the field logs and visual examination of field samples by an engineer. The lines designating the interface between various strata on the Boring Logsrepresent the approximate interface Atlanta, GA -Corporate Headquarters | 1375 Union Hill Industrial Court, Alpharetta,GA 30004 | (770)667-2040| www.eca-usa.com ! APPENDIX A Figures Atlanta, GA -Corporate Headquarters | 1375 Union Hill Industrial Court, Alpharetta,GA 30004 | (770)667-2040| www.eca-usa.com ! TJUF s N FSUftuMjoft N N ! APPENDIX B Boring Logs Atlanta, GA -Corporate Headquarters | 1375 Union Hill Industrial Court, Alpharetta,GA 30004 | (770)667-2040| www.eca-usa.com ! Project:Hot Springs Environmental Corp of America Log of Boring B-1 1375 Union Hill Industrial Ct. Suite-A Project Location:Hot Springs, NC Alpharetta, GA 30004 Sheet 1 of 1 (770) 667-2040 Project Number:V1440 Date(s) Logged ByChecked By 8/22/2019AXBHAA Drilled DrillingDrill BitTotal Depth HSA2.25 inches12.5 feet bgs MethodSize/Typeof Borehole Drill RigDrillingApproximate CME 45DSI TypeContractorSurface Elevation Groundwater LevelSamplingHammer Not EncounteredSPT140 Lbs hammer, rope and cathead and Date MeasuredMethod(s)Data Borehole Location CuttingsHot Springs, Madison County, North Carolina Backfill MATERIAL DESCRIPTION Depth (feet)Sample NumberSample TypeSampling Resistance, blows/ftSPT N-ValuesRec (%) / RQD (%)Material TypeUSCS SymbolWater Content (%)qu (tsf)qu (tsf)- Spring TesterLL (%)PI (%) 0 Dark brown, loose clayey Sadnd, SC 1trace roots, dry (Top Soil)---- 2-3-47 Yellowish brown, stiff sandy Silt with ML clay, damp 230.03.54115 1-3-69 5 Same as above, very stiff, dampML 3---- 5-8-1119 Same as above, very stiff, dampML 422.33.0-- 6-7-1219 10 Auger Refusal at 12.5 feet End of Boring at 12.5 feet. 15 20 F:\\PROJECT\\2019proj\\V1425 - V1449\\V1440\\All Borings_Hot Springs_V1440.bg4\[ECA Temp.tpl\] Project:Hot Springs Environmental Corp of America Log of Boring B-2 1375 Union Hill Industrial Ct. Suite-A Project Location:Hot Springs, NC Alpharetta, GA 30004 Sheet 1 of 1 (770) 667-2040 Project Number:V1440 Date(s) Logged ByChecked By 8/27/2019AXBHAA Drilled DrillingDrill BitTotal Depth HSA2.25 inches16 feet bgs MethodSize/Typeof Borehole Drill RigDrillingApproximate CME 45DSI TypeContractorSurface Elevation Groundwater LevelSamplingHammer Not EncounteredSPT140 Lbs hammer, rope and cathead and Date MeasuredMethod(s)Data Borehole Location CuttingsHot Springs, Madison County, North Carolina Backfill MATERIAL DESCRIPTION Depth (feet)Sample NumberSample TypeSampling Resistance, blows/ftSPT N-ValuesRec (%) / RQD (%)Material TypeUSCS SymbolWater Content (%)qu (tsf)qu (tsf)- Spring TesterLL (%)PI (%) 0 Yellowish brown/black, medium CL 1dense sandy Clay, damp---- 1-3-47 Same as above, very stiff, damp CL (Broken Sample) 219.1-4123 5-9-1322 5 Yellowish brown/red/grey, very stiff ML 3sandy Silt with clay, damp-4.5-- 7-13-1528 Yellowish brown, very stiff sandy ML Silt with clay and rock fragments, dry 412.3--- 14-14-1529 10 5---- 50/4''50/4'' Yellow, Weathered Rock fragments SM manually described as very compact dense silty Sand, dry 15 Auger Refusal at 16 feet End of Boring at 16 feet. 20 F:\\PROJECT\\2019proj\\V1425 - V1449\\V1440\\All Borings_Hot Springs_V1440.bg4\[ECA Temp.tpl\] Project:Hot Springs Environmental Corp of America Log of Boring B-3 1375 Union Hill Industrial Ct. Suite-A Project Location:Hot Springs, NC Alpharetta, GA 30004 Sheet 1 of 1 (770) 667-2040 Project Number:V1440 Date(s) Logged ByChecked By 8/22/2019AXBHAA Drilled DrillingDrill BitTotal Depth HSA2.25 inches13 feet bgs MethodSize/Typeof Borehole Drill RigDrillingApproximate CME 45DSI TypeContractorSurface Elevation Groundwater LevelSamplingHammer Not EncounteredSPT140 Lbs hammer, rope and cathead and Date MeasuredMethod(s)Data Borehole Location CuttingsHot Springs, Madison County, North Carolina Backfill MATERIAL DESCRIPTION Depth (feet)Sample NumberSample TypeSampling Resistance, blows/ftSPT N-ValuesRec (%) / RQD (%)Material TypeUSCS SymbolWater Content (%)qu (tsf)qu (tsf)- Spring TesterLL (%)PI (%) 0 Dark brown/black, loose clayey SC-CL 1Sand/sandy Clay, dry (Top Soil)-- 2-4-59 Yellowish brown, very stiff sandy ML Silt with clay, damp 221.43.0 4-8-1220 5 Same as above, very stiff, yellowish ML 3brown/red, damp-4.0 4-10-1424 Same as above, hard, with rock ML fragments, damp 421.8- 8-14-2034 10 Auger Refusal at 13 feet End of Boring at 13 feet. 15 20 F:\\PROJECT\\2019proj\\V1425 - V1449\\V1440\\All Borings_Hot Springs_V1440.bg4\[ECA Temp.tpl\] Project:Hot Springs Environmental Corp of America Log of Boring B-4 1375 Union Hill Industrial Ct. Suite-A Project Location:Hot Springs, NC Alpharetta, GA 30004 Sheet 1 of 1 (770) 667-2040 Project Number:V1440 Date(s) Logged ByChecked By 8/27/2019AXBHAA Drilled DrillingDrill BitTotal Depth HSA2.25 inches12.5 feet bgs MethodSize/Typeof Borehole Drill RigDrillingApproximate CME 45DSI TypeContractorSurface Elevation Groundwater LevelSamplingHammer Not EncounteredSPT140 Lbs hammer, rope and cathead and Date MeasuredMethod(s)Data Borehole Location CuttingsHot Springs, Madison County, North Carolina Backfill MATERIAL DESCRIPTION Depth (feet)Sample NumberSample TypeSampling Resistance, blows/ftSPT N-ValuesRec (%) / RQD (%)Material TypeUSCS SymbolWater Content (%)qu (tsf)qu (tsf)- Spring TesterLL (%)PI (%) 0 Dark brown/black, soft sandy Silt ML 1with clay, trace roots, moist (Top - 1-2-24 Soil) Red/yellowish brown, very stiff ML sandy Silt with clay, damp 217.8 3-8-1422 5 Same as above, very stiff, trace ML 3rock fragments, damp- 8-13-1730 Same as above, hard, trace rock ML fragments, damp 413.1 12-13-2235 10 Auger Refusal at 12.5 feet End of Boring at 12.5 feet. 15 20 F:\\PROJECT\\2019proj\\V1425 - V1449\\V1440\\All Borings_Hot Springs_V1440.bg4\[ECA Temp.tpl\] Project:Hot Springs Environmental Corp of America Log of Boring B-5 1375 Union Hill Industrial Ct. Suite-A Project Location:Hot Springs, NC Alpharetta, GA 30004 Sheet 1 of 1 (770) 667-2040 Project Number:V1440 Date(s) Logged ByChecked By 8/27/2019AXBHAA Drilled DrillingDrill BitTotal Depth HSA2.25 inches16 feet bgs MethodSize/Typeof Borehole Drill RigDrillingApproximate CME 45DSI TypeContractorSurface Elevation Groundwater LevelSamplingHammer Not EncounteredSPT140 Lbs hammer, rope and cathead and Date MeasuredMethod(s)Data Borehole Location CuttingsHot Springs, Madison County, North Carolina Backfill MATERIAL DESCRIPTION Depth (feet)Sample NumberSample TypeSampling Resistance, blows/ftSPT N-ValuesRec (%) / RQD (%)Material TypeUSCS SymbolWater Content (%)qu (tsf)qu (tsf)- Spring TesterLL (%)PI (%) 0 Dark brown/black, medium dense ML 1sandy Silt with clay, trace roots, ---- 2-2-35 damp (Top Soil) Red/yellowish brown, stiff sandy Silt ML with clay, damp 229.72.0-- 4-4-59 5 3---- 50/2''50/2'' Same as above, very hard, trace ML rock fragments, damp Red/yellowish brown, very stiff ML sandy Silt with clay and gravels, damp 424.9--- 5-8-2028 10 Light red, very compact dense silty SM 5Sand, trace Clay, damp--NPNP 21-25-50/3''75/9'' 15 Auger Refusal at 16 feet End of Boring at 16 feet. 20 F:\\PROJECT\\2019proj\\V1425 - V1449\\V1440\\All Borings_Hot Springs_V1440.bg4\[ECA Temp.tpl\] Project:Hot Springs Environmental Corp of America Log of Boring B-7 1375 Union Hill Industrial Ct. Suite-A Project Location:Hot Springs, NC Alpharetta, GA 30004 Sheet 1 of 1 (770) 667-2040 Project Number:V1440 Date(s) Logged ByChecked By 8/22/2019AXBHAA Drilled DrillingDrill BitTotal Depth HSA2.25 inches22 feet bgs MethodSize/Typeof Borehole Drill RigDrillingApproximate CME 45DSI TypeContractorSurface Elevation Groundwater LevelSamplingHammer Not EncounteredSPT140 Lbs hammer, rope and cathead and Date MeasuredMethod(s)Data Borehole Location CuttingsHot Springs, Madison County, North Carolina Backfill MATERIAL DESCRIPTION Depth (feet)Sample NumberSample TypeSampling Resistance, blows/ftSPT N-ValuesRec (%) / RQD (%)Material TypeUSCS SymbolWater Content (%)qu (tsf)qu (tsf)- Spring TesterLL (%)PI (%) 0 Dark brown/red, very stiff, sandy ML 1SIlt with clay, dry---- 4-8-1018 Red/yellowish brown, very stiff ML sandy Silt with clay, trace rock 222.64.5-- 17-7-1017 fragments, damp 5 Same as above, very stiff, dampML 3--4717 8-12-1527 Same as above, very stiff, dampML 424.2--- 2-9-1524 10 Red, Weathered Rock fragments GM 5---- 18-50/3''68/8'' manually described as very compact dense silty Gravel, damp 15 Same as above, very compact GM 6dense, dry10.2--- 27-35-4782 20 Auger Refusal at 22 feet End of Boring at 22 feet. F:\\PROJECT\\2019proj\\V1425 - V1449\\V1440\\All Borings_Hot Springs_V1440.bg4\[ECA Temp.tpl\] Project:Hot Springs Environmental Corp of America Log of Boring B-8 1375 Union Hill Industrial Ct. Suite-A Project Location:Hot Springs, NC Alpharetta, GA 30004 Sheet 1 of 1 (770) 667-2040 Project Number:V1440 Date(s) Logged ByChecked By 8/22/2019AXBHAA Drilled DrillingDrill BitTotal Depth HSA2.25 inches8 feet bgs MethodSize/Typeof Borehole Drill RigDrillingApproximate CME 45DSI TypeContractorSurface Elevation Groundwater LevelSamplingHammer Not EncounteredSPT140 Lbs hammer, rope and cathead and Date MeasuredMethod(s)Data Borehole Location CuttingsHot Springs, Madison County, North Carolina Backfill MATERIAL DESCRIPTION Depth (feet)Sample NumberSample TypeSampling Resistance, blows/ftSPT N-ValuesRec (%) / RQD (%)Material TypeUSCS SymbolWater Content (%)qu (tsf)qu (tsf)- Spring TesterLL (%)PI (%) 0 Dark brown/black, medium dense ML 1sandy Silt with clay, damp- 2-3-36 Red/yellowish brown, very stiff ML sandy Silt with clay, damp 229.2 2-10-1525 5 Same as above, very hard, dampML 3- 50/2''50/2'' Auger Refusal at 8 feet End of Boring at 8 feet. 10 15 20 F:\\PROJECT\\2019proj\\V1425 - V1449\\V1440\\All Borings_Hot Springs_V1440.bg4\[ECA Temp.tpl\] Project:Hot Springs Environmental Corp of America Log of Boring B-9 1375 Union Hill Industrial Ct. Suite-A Project Location:Hot Springs, NC Alpharetta, GA 30004 Sheet 1 of 1 (770) 667-2040 Project Number:V1440 Date(s) Logged ByChecked By 8/27/2019AXBHAA Drilled DrillingDrill BitTotal Depth HSA2.25 inches8.5 feet bgs MethodSize/Typeof Borehole Drill RigDrillingApproximate CME 45DSI TypeContractorSurface Elevation Groundwater LevelSamplingHammer Not EncounteredSPT140 Lbs hammer, rope and cathead and Date MeasuredMethod(s)Data Borehole Location CuttingsHot Springs, Madison County, North Carolina Backfill MATERIAL DESCRIPTION Depth (feet)Sample NumberSample TypeSampling Resistance, blows/ftSPT N-ValuesRec (%) / RQD (%)Material TypeUSCS SymbolWater Content (%)qu (tsf)qu (tsf)- Spring TesterLL (%)PI (%) 0 Dark brown/black, medium dense ML 1sandy Silt with clay, damp- 2-3-47 Red/yellowish brown, very stiff ML sandy silt with clay, trace rock 212.7 3-13-1528 fragments, damp (Broken Sample) 5 Light brown, very compact dense SM 3silty Sand, trace clay, trace rock - 6-33-2558 fragments, damp Auger Refusal at 8.5 feet End of Boring at 8.5 feet. 10 15 20 F:\\PROJECT\\2019proj\\V1425 - V1449\\V1440\\All Borings_Hot Springs_V1440.bg4\[ECA Temp.tpl\] Project:Hot Springs Environmental Corp of America Key to Log of Boring 1375 Union Hill Industrial Ct. Suite-A Project Location:Hot Springs, NC Alpharetta, GA 30004 Sheet 1 of 1 (770) 667-2040 Project Number:V1440 MATERIAL DESCRIPTION Depth (feet)Sample NumberSample TypeSampling Resistance, blows/ftSPT N-ValuesRec (%) / RQD (%)Material TypeUSCS SymbolWater Content (%)qu (tsf)qu (tsf)- Spring TesterLL (%)PI (%) 1234567891011121314 COLUMN DESCRIPTIONS 1Depth (feet): Depth in feet below the ground surface.9USCS Symbol: Graphic depiction of the subsurface material 2Sample Number: Sample identification number.encountered. 3Sample Type: Type of soil sample collected at the depth interval10Water Content (%): Water content of the soil sample, expressed as shown.percentage of dry weight of sample. 4Sampling Resistance, blows/ft: Number of blows to advance driven11qu (tsf): Unconfined compression test sampler one foot (or distance shown) beyond seating interval12qu (tsf)- Spring Tester: Unconfined Compression test value from a using the hammer identified on the boring log.spring tester 5SPT N-Values: SPT N-values13LL (%): Liquid Limit, expressed as a water content. 6Rec (%) / RQD (%): Core Recovery (%) and RQD (%)14PI (%): Plasticity Index, expressed as a water content. 7MATERIAL DESCRIPTION: Description of material encountered. May include consistency, moisture, color, and other descriptive text. 8Material Type: Type of material encountered. FIELD AND LABORATORY TEST ABBREVIATIONS CHEM: Chemical tests to assess corrosivityPI: Plasticity Index, percent COMP: Compaction testSA: Sieve analysis (percent passing No. 200 Sieve) CONS: One-dimensional consolidation testUC: Unconfined compressive strength test, Qu, in ksf LL: Liquid Limit, percentWA: Wash sieve (percent passing No. 200 Sieve) MATERIAL GRAPHIC SYMBOLS Lean CLAY, CLAY w/SAND, SANDY CLAY (CL)Clayey SAND (SC) Silty GRAVEL (GM)Clayey SAND to Sandy CLAY (SC-CL) SILT, SILT w/SAND, SANDY SILT (ML)Silty SAND (SM) TYPICAL SAMPLER GRAPHIC SYMBOLSOTHER GRAPHIC SYMBOLS Water level (at time of drilling, ATD) Auger samplerGrab SamplePitcher Sample Water level (after waiting) 2-inch-OD unlined split Bulk SampleHQ Rock Core spoon (SPT) Minor change in material properties within a stratum 3-inch-OD California w/2.5-inch-OD ModifiedShelby Tube (Thin-walled, brass ringsCalifornia w/ brass linersfixed head) Inferred/gradational contact between strata CME SamplerNQ Rock Core ? Queried contact between strata GENERAL NOTES 1: Soil classifications are based on the Unified Soil Classification System. Descriptions and stratum lines are interpretive, and actual lithologic changes may be gradual. Field descriptions may have been modified to reflect results of lab tests. 2: Descriptions on these logs apply only at the specific boring locations and at the time the borings were advanced. They are not warranted to be representative of subsurface conditions at other locations or times. F:\\PROJECT\\2019proj\\V1425 - V1449\\V1440\\All Borings_Hot Springs_V1440.bg4\[ECA Temp.tpl\] ! APPENDIX C ElectricalResistivity Test Results Atlanta, GA -Corporate Headquarters | 1375 Union Hill Industrial Court, Alpharetta,GA 30004 | (770)667-2040| www.eca-usa.com ! APPENDIX C Earth Resistivity Testing Results Environmental Corporation of America (ECA) Site Name: Hot Springs ECA Project No. V1440 Laboratory Electrical Resistivity TestData per ASTM G-57. Sample Depth Resistivity Test#1Meter Reading (R) (feet)(Ohms-cm) #10-834.1944,187 #20-834.1944,187 #30-834.1844,174 #40-834.1944,187 Average Result44,184 Sample Depth Resistivity Test #2Meter Reading (R) (feet)(Ohms-cm) #10-832.1243,308 #20-832.1143,294 #30-832.1243,308 #40-832.1143,294 Average Result43,301 Site Name: Hot Springs ECA Project No. V1440 Field Electrical Resistivity Test Data per ASTM G-57. Test #1 Field Meter Reading Rod Spacing Calculated Resistivity (North-South Line) (feet)(Ohms-cm) (Ohms) 239.3015,052 424.9019,073 822.0033,704 1616.6951,138 2520.3097,186 4015.50118,730 Average Result55,814 Test #2 Field Meter Reading Calculated Resistivity Rod Spacing (North-South Line) (feet)(Ohms-cm) (Ohms) 238.7014,822 427.2020,835 818.1827,852 1622.3068,327 2518.6089,048 4015.86121,488 Average Result57,062 ! APPENDIX D Laboratory TestResults Geotechnical and Analytical Testing Results Atlanta, GA -Corporate Headquarters | 1375 Union Hill Industrial Court, Alpharetta,GA 30004 | (770)667-2040| www.eca-usa.com ! IMELY 1874 Forge Street Tucker, GA 30084 NGINEERING Phone: 770-938-8233 Tested ByIH OIL Fax: 770-923-8973 Date08/29/19 ESTS, LLC www.test-llc.com Checked By Web: Client Pr. #V1.440Lab. PR. #1999-04-1 Pr. NameSolar Farm DevelopmentS. TypeBag Sample ID31379/SS-1Depth/Elev.- LocationB-1 Add. Info- ASTM D 4318/AASHTO T 88, T 89 Standard Test Method for Liquid Limit,Plastic Limit, and Plasticity Index of Soils (Atterberg Limits) LIQUID LIMIT Number of Blows322715 Mass ofWet Sample & Tare, g35.8036.9038.96Oven ID #15/496/610 Mass of Dry Sample & Tare, g32.5033.7035.53Balance ID #139/563 Mass of Tare, g24.2525.8627.65Liquid Limit Device ID #451/569 Moisture Content, %40.0040.8243.53 46 45 44 % 43 ONTENT 42 C E R 41 TU IS O 40 M 39 38 10100 20253040 NUMBER OF BLOWS PLASTIC LIMIT Mass ofWet Sample & Tare, g43.1737.53 Mass of Dry Sample & Tare, g39.9035.22 Mass of Tare, g27.4226.28NOTE:MATERIAL PASSING NO. 40 SIEVE Moisture Content, %26.2025.84WAS USED FOR TEST NATURALMOISTURE Mass ofWet Sample & Tare, g248.30LIQUID LIMIT (LL)41 Mass of Dry Sample & Tare, g228.20PLASTIC LIMIT (PL)26 Mass of Tare, g140.50PLASTICITY INDEX (PI)15 Moisture Content, %22.92LIQUIDITY INDEX (LI)-0.21 Yellowish Brown Sandy Silt DESCRIPTION USCS (ASTM D2487; D2488)MLAASHTO (M 145)NA IMELY 1874 Forge Street Tucker, GA 30084 RI NGINEERING Phone: 770-938-8233 Tested By 08/28/19 OIL Fax: 770-923-8973 Date ESTS, LLC Web:www.test-llc.com Checked By Client Pr. #V1.440 Lab. PR. #1999-04-1 Pr. Name Solar Farm Development S. Type Bag Sample ID 31379/SS-1 Depth/Elev.- Location B-1 Add. Info- ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311; Particle Size Analysis (Split Sieve) MOISTURE CONTENT of TOTAL SAMPLEMOISTURE CONTENT of FINE MATERIAL Mass ofWet Sample & Tare, g 248.3 Mass ofWet Sample & Tare, g 248.30 Mass of Dry Sample & Tare, g 228.2 Mass of Dry Sample & Tare, g 228.20 Mass of Tare, g 140.5 Mass of Tare, g 140.50 Moisture Content, %22.9 Moisture Content, %22.9 TOTALMass ofwet sample 344.3 Mass ofWet Fine Material & Tare, g 100.60 before splitting & tare, g Mass of Tare, g 0.0 Mass of Tare, g 0.00 TOTALMass of dry sample, g 280.1 Mass of Dry Fine Material, g 81.84 100.0 % of Total Sample Passing Split Sieve SIEVE ANALYSIS* COARSEMATERIALFINEMATERIAL Mass of Tare, g0.0Mass of Tare, g0.00 Sieve SizeSample & Tare, g% RETAINED% PASSING 12"COBBLES 0.0100.0 Cumulative% PASSING 3"0.0100.0 Sieve SizeMass retained, g(ofTotal) 2.5"COARSE 0.0100.0#10MEDIUM 0.5699.3 2"GRAVEL 0.0100.0#20SAND 2.7596.6 1.5"0.0100.0#40 8.0890.1 1"0.0100.0#60FINE SAND 14.9581.7 .75"0.0100.0#100 21.4473.8 .5"FINE GRAVEL 0.0100.0#200FINES 27.0067.0 .375"0.0100.0 * - ASTM Definitions of Classification #4COARSE SAND 0.00.0100.0 ** - AASHTO Definitions of Classification NOTE:# 4(4.75mm)Sieve used for splitting sample on fine and coarse material PARTICLE-SIZE ANALYSIS* Oven ID #15/496/610% COBBLES 0.0%MEDIUM Sand 9.2 Balance ID#139/142/700% COARSE Gravel 0.0% FINE Sand 23.1 Sieve Shaker ID #555% FINE Gravel 0.0% FINES 67.0 % COARSE Sand 0.7%TOTAL SAMPLE 100.0 REMARKSPARTICLE-SIZE ANALYSIS** % COBBLES 0.0% COARSE Sand 9.2 % COARSE Gravel (Stone)0.0% FINE Sand 23.1 %MEDIUM Gravel (Stone)0.0% FINES (Silt-Clay)67.0 % FINE Gravel (Stone)0.7%TOTAL SAMPLE 100.0 DESCRIPTION Yellowish Brown Sandy Silt USCS (ASTM D2487; D2488)MLAASHTO (M 145)NA Page 1 of 2 IMELY 1874 Forge StreetTucker, GA 30084 NGINEERING Phone: 770-938-8233 Tested ByRI OIL Fax: 770-923-8973 Date08/28/19 ESTS, LLC Web:www.test-llc.com Checked By Client Pr. #V1.440Lab. PR. #1999-04-1 Pr. NameSolar Farm DevelopmentS.Type Bag 31379/SS-1 Sample IDDepth/Elev.- B-1 LocationAdd. Info- ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311 Standard Test Method forParticle-Size Analysis of Soils and Aggregates (Split Sieve) Particle-SizeAnalysis 12"6"3"2"1".5"#4#8 #10#16#20#30#40#50#60 2.5"1.5".75".25" #100#140#200 .375" 100 90 80 % 70 P 60 A S 50 S I N 40 G 30 20 10 0 10001001010.10.010.001 Grain size in millimeters CoarseFine CoarseMedium Fine Silt or Clay BouldersCobblesGravelSand Fines D NAmm 10 D NAmm 30 D NAmm 60 CuNA CcNA Project's Specific % Passing NA Page 2 of 2 Project's Specific Particle Size,mm NA IMELY 1874 Forge Street Tucker, GA 30084 NGINEERING Phone: 770-938-8233 Tested ByIH OIL Fax: 770-923-8973 Date08/29/19 ESTS, LLC www.test-llc.com Checked By Web: Client Pr. #V1.440Lab. PR. #1999-04-1 Pr. NameSolar Farm DevelopmentS. TypeBag Sample ID31380/SS-2Depth/Elev.- LocationB-2 Add. Info- ASTM D 4318/AASHTO T 88, T 89 Standard Test Method for Liquid Limit,Plastic Limit, and Plasticity Index of Soils (Atterberg Limits) LIQUID LIMIT Number of Blows342620 Mass ofWet Sample & Tare, g39.1537.1532.37Oven ID #15/496/610 Mass of Dry Sample & Tare, g36.2134.0629.27Balance ID #139/563 Mass of Tare, g28.6826.4821.96Liquid Limit Device ID #451/569 Moisture Content, %39.0440.7742.41 45 44 43 % 42 ONTENT 41 C E R 40 TU IS O 39 M 38 37 10100 20253040 NUMBER OF BLOWS PLASTIC LIMIT Mass ofWet Sample & Tare, g44.8934.81 Mass of Dry Sample & Tare, g41.9632.99 Mass of Tare, g25.8422.78NOTE:MATERIAL PASSING NO. 40 SIEVE Moisture Content, %18.1817.83WAS USED FOR TEST NATURALMOISTURE Mass ofWet Sample & Tare, g282.20LIQUID LIMIT (LL)41 Mass of Dry Sample & Tare, g261.00PLASTIC LIMIT (PL)18 Mass of Tare, g139.10PLASTICITY INDEX (PI)23 Moisture Content, %17.39LIQUIDITY INDEX (LI)-0.03 Yellowish Red and Gray Sandy Lean Clay DESCRIPTION USCS (ASTM D2487; D2488)CLAASHTO (M 145)NA IMELY 1874 Forge Street Tucker, GA 30084 RI NGINEERING Phone: 770-938-8233 Tested By 08/28/19 OIL Fax: 770-923-8973 Date ESTS, LLC Web:www.test-llc.com Checked By Client Pr. #V1.440 Lab. PR. #1999-04-1 Pr. Name Solar Farm Development S. Type Bag Sample ID 31380/SS-2 Depth/Elev.- Location B-2 Add. Info- ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311; Particle Size Analysis (Split Sieve) MOISTURE CONTENT of TOTAL SAMPLEMOISTURE CONTENT of FINE MATERIAL Mass ofWet Sample & Tare, g 282.2 Mass ofWet Sample & Tare, g 282.20 Mass of Dry Sample & Tare, g 261.0 Mass of Dry Sample & Tare, g 261.00 Mass of Tare, g 139.1 Mass of Tare, g 139.10 Moisture Content, %17.4 Moisture Content, %17.4 TOTALMass ofwet sample 427.5 Mass ofWet Fine Material & Tare, g 100.20 before splitting & tare, g Mass of Tare, g 0.0 Mass of Tare, g 0.00 TOTALMass of dry sample, g 364.2 Mass of Dry Fine Material, g 85.36 99.8 % of Total Sample Passing Split Sieve SIEVE ANALYSIS* COARSEMATERIALFINEMATERIAL Mass of Tare, g0.0Mass of Tare, g0.00 Sieve SizeSample & Tare, g% RETAINED% PASSING 12"COBBLES 0.0100.0 Cumulative% PASSING 3"0.0100.0 Sieve SizeMass retained, g(ofTotal) 2.5"COARSE 0.0100.0#10MEDIUM 1.2398.3 2"GRAVEL 0.0100.0#20SAND 6.8491.8 1.5"0.0100.0#40 16.0781.0 1"0.0100.0#60FINE SAND 26.6168.7 .75"0.0100.0#100 34.8559.0 .5"FINE GRAVEL 0.0100.0#200FINES 40.8252.1 .375"0.00.0100.0 * - ASTM Definitions of Classification #4COARSE SAND 0.80.299.8 ** - AASHTO Definitions of Classification NOTE:# 4(4.75mm)Sieve used for splitting sample on fine and coarse material PARTICLE-SIZE ANALYSIS* Oven ID #15/496/610% COBBLES 0.0%MEDIUM Sand 17.3 Balance ID#139/142/700% COARSE Gravel 0.0% FINE Sand 28.9 Sieve Shaker ID #555% FINE Gravel 0.2% FINES 52.1 % COARSE Sand 1.4%TOTAL SAMPLE 100.0 REMARKSPARTICLE-SIZE ANALYSIS** % COBBLES 0.0% COARSE Sand 17.3 % COARSE Gravel (Stone)0.0% FINE Sand 28.9 %MEDIUM Gravel (Stone)0.0% FINES (Silt-Clay)52.1 % FINE Gravel (Stone)1.7%TOTAL SAMPLE 100.0 DESCRIPTION Yellowish Red and Gray Sandy Lean Clay USCS (ASTM D2487; D2488)CLAASHTO (M 145)NA Page 1 of 2 IMELY 1874 Forge StreetTucker, GA 30084 NGINEERING Phone: 770-938-8233 Tested ByRI OIL Fax: 770-923-8973 Date08/28/19 ESTS, LLC Web:www.test-llc.com Checked By Client Pr. #V1.440Lab. PR. #1999-04-1 Pr. NameSolar Farm DevelopmentS.Type Bag 31380/SS-2 Sample IDDepth/Elev.- B-2 LocationAdd. Info- ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311 Standard Test Method forParticle-Size Analysis of Soils and Aggregates (Split Sieve) Particle-SizeAnalysis 12"6"3"2"1".5"#4#8 #10#16#20#30#40#50#60 2.5"1.5".75".25" #100#140#200 .375" 100 90 80 % 70 P 60 A S 50 S I N 40 G 30 20 10 0 10001001010.10.010.001 Grain size in millimeters CoarseFine CoarseMedium Fine Silt or Clay BouldersCobblesGravelSand Fines D NAmm 10 D NAmm 30 D NAmm 60 CuNA CcNA Project's Specific % Passing NA Page 2 of 2 Project's Specific Particle Size,mm NA IMELY 1874 Forge StreetTucker, GA 30084 NGINEERING Phone: 770-938-8233 Tested ByIH OIL Fax: 770-923-8973 Date08/29/19 ESTS, LLC Web:www.test-llc.com Checked By 1999-04-1 Client Pr. #V1.440Lab. PR. # Pr. NameSolar Farm DevelopmentS.TypeBag Sample ID31382/SS-4Depth/Elev.- LocationB-56Add. Info- ASTM D 4318 Standard Test Method for Liquid Limit,Plastic Limit, and Plasticity Index of Soils (Atterberg Limits) LIQUID LIMIT Liquid Limit Device ID #56 NOTES: 1. Material appears to be Number of Blows1212 Weight ofWet Sample & Tare, g41.1642.51Nonplastic. (Liquid Limit or Plastic Weight of Dry Soil & Tare, g38.5540.15Limit test could not be performed.) Weight ofTare, g26.6929.332.Material passing No. 40 sievewas Moisture Content, %22.0121.81usedfor test. 58 57 56 55 NONPLASTIC 54 53 52 MOISTURE CONTENT % 51 50 10100 203040 NUMBER OFBLOWS PLASTIC LIMIT Weight ofWet Soil & Tare, g38.8238.23 Weight of Dry Soil & Tare, g36.4036.28 Weight ofTare, g25.2127.40Oven ID Number 15/496/610 Moisture Content, %21.6321.96Balance ID Number 139/563 NATURALMOISTURE Weight ofWet Soil & Tare, g278.80LIQUID LIMIT (LL)NP Weight of Dry Soil & Tare, g264.70PLASTIC LIMIT (PL)NP Weight ofTare, g138.50PLASTICITY INDEX (PI)NP Moisture Content, %11.17LIQUIDITY INDEX (LI)- DESCRIPTIONYellowish Brown Silty Sand with Gravel USCS (ASTM D2487;2488)SMAASHTO (M 145)NA IMELY 1874 Forge Street Tucker, GA 30084 RI NGINEERING Phone: 770-938-8233 Tested By 08/28/19 OIL Fax: 770-923-8973 Date ESTS, LLC Web:www.test-llc.com Checked By Client Pr. #V1.440 Lab. PR. #1999-04-1 Pr. Name Solar Farm Development S. Type Bag Sample ID 31382/SS-4 Depth/Elev.- Location B-56 Add. Info- ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311; Particle Size Analysis (Split Sieve) MOISTURE CONTENT of TOTAL SAMPLEMOISTURE CONTENT of FINE MATERIAL Mass ofWet Sample & Tare, g 278.8 Mass ofWet Sample & Tare, g 278.80 Mass of Dry Sample & Tare, g 264.7 Mass of Dry Sample & Tare, g 264.70 Mass of Tare, g 138.5 Mass of Tare, g 138.50 Moisture Content, %11.2 Moisture Content, %11.2 TOTALMass ofwet sample 294.4 Mass ofWet Fine Material & Tare, g 100.20 before splitting & tare, g Mass of Tare, g 0.0 Mass of Tare, g 0.00 TOTALMass of dry sample, g 264.8 Mass of Dry Fine Material, g 90.13 81.7 % of Total Sample Passing Split Sieve SIEVE ANALYSIS* COARSEMATERIALFINEMATERIAL Mass of Tare, g0.0Mass of Tare, g0.00 Sieve SizeSample & Tare, g% RETAINED% PASSING 12"COBBLES 0.0100.0 Cumulative% PASSING 3"0.0100.0 Sieve SizeMass retained, g(ofTotal) 2.5"COARSE 0.0100.0#10MEDIUM 3.0579.0 2"GRAVEL 0.0100.0#20SAND 4.9377.3 1.5"0.0100.0#40 6.6075.7 1"0.00.0100.0#60FINE SAND 16.8566.4 .75"26.710.189.9#100 39.2146.2 .5"FINE GRAVEL 38.814.785.3#200FINES 52.6634.0 .375"40.515.384.7 * - ASTM Definitions of Classification #4COARSE SAND 48.418.381.7 ** - AASHTO Definitions of Classification NOTE:# 4(4.75mm)Sieve used for splitting sample on fine and coarse material PARTICLE-SIZE ANALYSIS* Oven ID #15/496/610% COBBLES 0.0%MEDIUM Sand 3.2 Balance ID#139/142/700% COARSE Gravel 10.1% FINE Sand 41.8 Sieve Shaker ID #555% FINE Gravel 8.2% FINES 34.0 % COARSE Sand 2.8%TOTAL SAMPLE 100.0 REMARKSPARTICLE-SIZE ANALYSIS** % COBBLES 0.0% COARSE Sand 3.2 % COARSE Gravel (Stone)0.0% FINE Sand 41.8 %MEDIUM Gravel (Stone)15.3% FINES (Silt-Clay)34.0 % FINE Gravel (Stone)5.7%TOTAL SAMPLE 100.0 DESCRIPTION Yellowish Brown Silty Sand with Gravel USCS (ASTM D2487; D2488)SMAASHTO (M 145)NA Page 1 of 2 IMELY 1874 Forge StreetTucker, GA 30084 NGINEERING Phone: 770-938-8233 Tested ByRI OIL Fax: 770-923-8973 Date08/28/19 ESTS, LLC Web:www.test-llc.com Checked By Client Pr. #V1.440Lab. PR. #1999-04-1 Pr. NameSolar Farm DevelopmentS.Type Bag 31382/SS-4 Sample IDDepth/Elev.- B-56 LocationAdd. Info- ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311 Standard Test Method forParticle-Size Analysis of Soils and Aggregates (Split Sieve) Particle-SizeAnalysis 12"6"3"2"1".5"#4#8#10#16#20#30#40#50#60 2.5"1.5".75".25" #100#140#200 .375" 100 90 80 % 70 P 60 A S 50 S I N 40 G 30 20 10 0 10001001010.10.010.001 Grain size in millimeters CoarseFine CoarseMedium Fine Silt or Clay BouldersCobblesGravelSand Fines D NAmm 10 D NAmm 30 D NAmm 60 CuNA CcNA Project's Specific % Passing NA Page 2 of 2 Project's Specific Particle Size,mm NA IMELY 1874 Forge Street Tucker, GA 30084 NGINEERING Phone: 770-938-8233 Tested ByIH OIL Fax: 770-923-8973 Date08/29/19 ESTS, LLC www.test-llc.com Checked By Web: Client Pr. #V1.440Lab. PR. #1999-04-1 Pr. NameSolar Farm DevelopmentS. TypeBag Sample ID31381/SS-3Depth/Elev.- LocationB-7 Add. Info- ASTM D 4318/AASHTO T 88, T 89 Standard Test Method for Liquid Limit,Plastic Limit, and Plasticity Index of Soils (Atterberg Limits) LIQUID LIMIT Number of Blows302116 Mass ofWet Sample & Tare, g37.4135.0936.05Oven ID #15/496/610 Mass of Dry Sample & Tare, g33.5431.3232.24Balance ID #139/563 Mass of Tare, g25.1223.3724.40Liquid Limit Device ID #451/569 Moisture Content, %45.9647.4248.60 50 49 % 48 ONTENT 47 C E R TU 46 IS O M 45 44 10100 20253040 NUMBER OF BLOWS PLASTIC LIMIT Mass ofWet Sample & Tare, g37.0337.22 Mass of Dry Sample & Tare, g34.2334.53 Mass of Tare, g24.8725.54NOTE:MATERIAL PASSING NO. 40 SIEVE Moisture Content, %29.9129.92WAS USED FOR TEST NATURALMOISTURE Mass ofWet Sample & Tare, g291.00LIQUID LIMIT (LL)47 Mass of Dry Sample & Tare, g262.30PLASTIC LIMIT (PL)30 Mass of Tare, g139.00PLASTICITY INDEX (PI)17 Moisture Content, %23.28LIQUIDITY INDEX (LI)-0.40 Red Silt with Sand DESCRIPTION USCS (ASTM D2487; D2488)MLAASHTO (M 145)NA IMELY 1874 Forge Street Tucker, GA 30084 RI NGINEERING Phone: 770-938-8233 Tested By 08/28/19 OIL Fax: 770-923-8973 Date ESTS, LLC Web:www.test-llc.com Checked By Client Pr. #V1.440 Lab. PR. #1999-04-1 Pr. Name Solar Farm Development S. Type Bag Sample ID 31381/SS-3 Depth/Elev.- Location B-7 Add. Info- ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311; Particle Size Analysis (Split Sieve) MOISTURE CONTENT of TOTAL SAMPLEMOISTURE CONTENT of FINE MATERIAL Mass ofWet Sample & Tare, g 291.0 Mass ofWet Sample & Tare, g 291.0 Mass of Dry Sample & Tare, g 262.3 Mass of Dry Sample & Tare, g 262.3 Mass of Tare, g 139.0 Mass of Tare, g 139.0 Moisture Content, %23.3 Moisture Content, %23.3 TOTALMass ofwet sample 503.0 Mass ofWet Fine Material & Tare, g 102.60 before splitting & tare, g Mass of Tare, g 0.0 Mass of Tare, g 0.00 TOTALMass of dry sample, g 408.0 Mass of Dry Fine Material, g 83.23 99.9 % of Total Sample Passing Split Sieve SIEVE ANALYSIS* COARSEMATERIALFINEMATERIAL Mass of Tare, g0.0Mass of Tare, g0.00 Sieve SizeSample & Tare, g% RETAINED% PASSING 12"COBBLES 0.0100.0 Cumulative% PASSING 3"0.0100.0 Sieve SizeMass retained, g(ofTotal) 2.5"COARSE 0.0100.0#10MEDIUM 1.1698.5 2"GRAVEL 0.0100.0#20SAND 4.2694.7 1.5"0.0100.0#40 8.4989.7 1"0.0100.0#60FINE SAND 13.7883.3 .75"0.0100.0#100 18.6577.5 .5"FINE GRAVEL 0.0100.0#200FINES 23.4671.7 .375"0.00.0100.0 * - ASTM Definitions of Classification #4COARSE SAND 0.60.199.9 ** - AASHTO Definitions of Classification NOTE:# 4(4.75mm)Sieve used for splitting sample on fine and coarse material PARTICLE-SIZE ANALYSIS* Oven ID #15/496/610% COBBLES 0.0%MEDIUM Sand 8.8 Balance ID#139/142/700% COARSE Gravel 0.0% FINE Sand 18.0 Sieve Shaker ID #555% FINE Gravel 0.1% FINES 71.7 % COARSE Sand 1.4%TOTAL SAMPLE 100.0 REMARKSPARTICLE-SIZE ANALYSIS** % COBBLES 0.0% COARSE Sand 8.8 % COARSE Gravel (Stone)0.0% FINE Sand 18.0 %MEDIUM Gravel (Stone)0.0% FINES (Silt-Clay)71.7 % FINE Gravel (Stone)1.5%TOTAL SAMPLE 100.0 DESCRIPTION Red Silt with Sand USCS (ASTM D2487; D2488)MLAASHTO (M 145)NA Page 1 of 2 IMELY 1874 Forge StreetTucker, GA 30084 NGINEERING Phone: 770-938-8233 Tested ByRI OIL Fax: 770-923-8973 Date08/28/19 ESTS, LLC Web:www.test-llc.com Checked By Client Pr. #V1.440Lab. PR. #1999-04-1 Pr. NameSolar Farm DevelopmentS.Type Bag 31381/SS-3 Sample IDDepth/Elev.- B-7 LocationAdd. Info- ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311 Standard Test Method forParticle-Size Analysis of Soils and Aggregates (Split Sieve) Particle-SizeAnalysis 12"6"3"2"1".5"#4#8#10#16#20#30#40#50#60 2.5"1.5".75".25" #100#140#200 .375" 100 90 80 % 70 P 60 A S 50 S I N 40 G 30 20 10 0 10001001010.10.010.001 Grain size in millimeters CoarseFine CoarseMedium Fine Silt or Clay BouldersCobblesGravelSand Fines D NAmm 10 D NAmm 30 D NAmm 60 CuNA CcNA Project's Specific % Passing NA Page 2 of 2 Project's Specific Particle Size,mm NA T IMELY 1874ForgeStreetTucker,GA30084 E NGINEERING Phone:770-938-8233 TestedByRI/EB S OIL Fax:770-923-8973 Date08/29/19 T ESTS,LLC Web:www.test-llc.com CheckedBy Client Pr. #V1.440Lab.PR. #1999-04-1 Pr.NameSolarFarmDevelopmentS.TypeRemold SampleID31383/SS-5&SS-6Depth/Elev.- LocationB-1&B-3 Add. Info- ASTMD5334 StandardTestMethodforDeterminationofThermalConductivity/Resistivityof Soiland SoftRock byThermalNeedle Probe Procedure DeterminationofThermalResistivityatRemoldedCondition(at SpecifiedMoistureContentandDensity) NaturalMoistureContentProctorData MassofWet Sample & Tare, g1925.80 MassofDry Sample & Tare, g1671.50MaximumDryDensity,pcf106.60 MassofTare, g334.50OptimumMoistureContent(O.M.C.), %17.70 MoistureContent, %19.0 TESTDATA(Specimen#1) RequestedDifference fromOMC, %-4.0MoistureContent MOLD # Requested%Compaction fromMDD 95.0MassofWet Sample & Tare, g488.20 25 AverageHeightofMold,inch8.000MassofDry Sample & Tare, g440.10 AverageDiameterofMold,inch2.810MassofTare, g89.90 MassofMold, g1042.50MoistureContent, %13.7 Trial #12 MassofMold+ Soil, g2537.80 o Massof Soil, g1495.30Temperature,C25.7625.67 3 Volumeof Soil, ft 0.02871ThermalResistivityReading,rho°C·cm/W55.5455.45 WetDensityofRemolded Soil,pcf114.8 AverageTh.ResistivityReading,rho°C·cm/W55.50 DryDensityofRemolded Soil,pcf101.0CalibrationThermalResistivityReading,rho101.40°C·cm/W o ActualDifference fromOMC, %-4.0CalibrationTemperature,C25.53 Actual % Compaction fromMDD94.7CalibrationThermalResistivityFactor1.0020 Reported SoilThermalResistivity 55.60°C·cm/W o DeterminationofThermalResistivityat OvenDriedCondition(110C) TESTDATA(Specimen#1A) TESTDATA Trial #12 Remarks o Testingwasperformedonremolded(perabove Temperature,C28.3028.07 parameters) specimenafterovendrying. ThermalResistivityReading,rho°C·cm/W142.30143.70 MoistureContentof Specimenis0%. AverageTh.ResistivityReading,rho°C·cm/W143.00 CalibrationThermalResistivityReading,rho101.40°C·cm/W o CalibrationTemperature,C25.53 CalibrationThermalResistivityFactor 1.0020 Reported SoilThermalResistivity 143.28°C·cm/W OvenID #496/610 Description NA BalanceID #563/700 Sensor ID #827 ConductivityMeter ID #826 Calibration Standard #SE2499 USCS(D2487;D2488)NA Calibration Value,rho 101.60°C·cm/WAASHTO(M145)NA T IMELY 1874ForgeStreetTucker,GA30084 E NGINEERING Phone:770-938-8233 TestedByRI/EB S OIL Fax:770-923-8973 Date08/29/19 T ESTS,LLC Web:www.test-llc.com CheckedBy Client Pr. #V1.440Lab.PR. #1999-04-1 Pr.NameSolarFarmDevelopmentS.TypeRemold SampleID31383/SS-5&SS-6Depth/Elev.- LocationB-1&B-3 Add. Info- ASTMD5334 StandardTestMethodforDeterminationofThermalConductivity/Resistivityof Soiland SoftRock byThermalNeedle Probe Procedure DeterminationofThermalResistivityatRemoldedCondition(at SpecifiedMoistureContentandDensity) NaturalMoistureContentProctorData MassofWet Sample & Tare, g1925.80 MassofDry Sample & Tare, g1671.50MaximumDryDensity,pcf106.60 MassofTare, g334.50OptimumMoistureContent(O.M.C.), %17.70 MoistureContent, %19.0 TESTDATA(Specimen#2) RequestedDifference fromOMC, %-2.0MoistureContent MOLD # Requested%Compaction fromMDD 95.0MassofWet Sample & Tare, g507.00 26 AverageHeightofMold,inch8.000MassofDry Sample & Tare, g451.30 AverageDiameterofMold,inch2.810MassofTare, g101.00 MassofMold, g1048.50MoistureContent, %15.9 Trial #12 MassofMold+ Soil, g2572.40 o Massof Soil, g1523.90Temperature,C26.4525.79 3 Volumeof Soil, ft 0.02871ThermalResistivityReading,rho°C·cm/W50.8450.64 WetDensityofRemolded Soil,pcf117.0 AverageTh.ResistivityReading,rho°C·cm/W50.74 DryDensityofRemolded Soil,pcf101.0CalibrationThermalResistivityReading,rho101.40°C·cm/W o ActualDifference fromOMC, %-1.8CalibrationTemperature,C25.53 Actual % Compaction fromMDD94.7CalibrationThermalResistivityFactor1.0020 Reported SoilThermalResistivity 50.84°C·cm/W o DeterminationofThermalResistivityat OvenDriedCondition(110C) TESTDATA(Specimen#2A) TESTDATA Trial #12 Remarks o Temperature,C ThermalResistivityReading,rho°C·cm/W AverageTh.ResistivityReading,rho°C·cm/W CalibrationThermalResistivityReading,rho101.40°C·cm/W o CalibrationTemperature,C25.53 CalibrationThermalResistivityFactor Reported SoilThermalResistivity NA°C·cm/W OvenID #496/610 Description NA BalanceID #563/700 Sensor ID #827 ConductivityMeter ID #826 Calibration Standard #SE2499 USCS(D2487;D2488)NA Calibration Value,rho 101.60°C·cm/WAASHTO(M145)NA T IMELY 1874ForgeStreetTucker,GA30084 E NGINEERING Phone:770-938-8233 TestedByRI/EB S OIL Fax:770-923-8973 Date08/29/19 T ESTS,LLC Web:www.test-llc.com CheckedBy Client Pr. #V1.440Lab.PR. #1999-04-1 Pr.NameSolarFarmDevelopmentS.TypeRemold SampleID31383/SS-5&SS-6Depth/Elev.- LocationB-1&B-3 Add. Info- ASTMD5334 StandardTestMethodforDeterminationofThermalConductivity/Resistivityof Soiland SoftRock byThermalNeedle Probe Procedure DeterminationofThermalResistivityatRemoldedCondition(at SpecifiedMoistureContentandDensity) NaturalMoistureContentProctorData MassofWet Sample & Tare, g1925.80 MassofDry Sample & Tare, g1671.50MaximumDryDensity,pcf106.60 MassofTare, g334.50OptimumMoistureContent(O.M.C.), %17.70 MoistureContent, %19.0 TESTDATA(Specimen#3) RequestedDifference fromOMC, %0.0MoistureContent MOLD # Requested%Compaction fromMDD 95.0MassofWet Sample & Tare, g511.00 27 AverageHeightofMold,inch8.000MassofDry Sample & Tare, g448.60 AverageDiameterofMold,inch2.810MassofTare, g100.30 MassofMold, g1045.30MoistureContent, %17.9 Trial #12 MassofMold+ Soil, g2594.00 o Massof Soil, g1548.70Temperature,C26.0725.97 3 Volumeof Soil, ft 0.02871ThermalResistivityReading,rho°C·cm/W47.7648.02 WetDensityofRemolded Soil,pcf118.9 AverageTh.ResistivityReading,rho°C·cm/W47.89 DryDensityofRemolded Soil,pcf100.8CalibrationThermalResistivityReading,rho101.40°C·cm/W o ActualDifference fromOMC, %0.2CalibrationTemperature,C25.53 Actual % Compaction fromMDD94.6CalibrationThermalResistivityFactor1.0020 Reported SoilThermalResistivity 47.98°C·cm/W o DeterminationofThermalResistivityat OvenDriedCondition(110C) TESTDATA(Specimen#3A) TESTDATA Trial #12 Remarks o Temperature,C ThermalResistivityReading,rho°C·cm/W AverageTh.ResistivityReading,rho°C·cm/W CalibrationThermalResistivityReading,rho101.40°C·cm/W o CalibrationTemperature,C25.53 CalibrationThermalResistivityFactor Reported SoilThermalResistivity NA°C·cm/W OvenID #496/610 Description NA BalanceID #563/700 Sensor ID #827 ConductivityMeter ID #826 Calibration Standard #SE2499 USCS(D2487;D2488)NA Calibration Value,rho 101.60°C·cm/WAASHTO(M145)NA T IMELY 1874ForgeStreetTucker,GA30084 E NGINEERING Phone:770-938-8233 TestedByRI/EB S OIL Fax:770-923-8973 Date08/29/19 T ESTS,LLC Web:www.test-llc.com CheckedBy Client Pr. #V1.440Lab.PR. #1999-04-1 Pr.NameSolarFarmDevelopmentS.TypeRemold SampleID31383/SS-5&SS-6Depth/Elev.- LocationB-1&B-3 Add. Info- ASTMD5334 StandardTestMethodforDeterminationofThermalConductivity/Resistivityof Soiland SoftRock byThermalNeedle Probe Procedure DeterminationofThermalResistivityatRemoldedCondition(at SpecifiedMoistureContentandDensity) NaturalMoistureContentProctorData MassofWet Sample & Tare, g1925.80 MassofDry Sample & Tare, g1671.50MaximumDryDensity,pcf106.60 MassofTare, g334.50OptimumMoistureContent(O.M.C.), %17.70 MoistureContent, %19.0 TESTDATA(Specimen#4) RequestedDifference fromOMC, %2.0MoistureContent MOLD # Requested%Compaction fromMDD 95.0MassofWet Sample & Tare, g512.20 28 AverageHeightofMold,inch8.000MassofDry Sample & Tare, g442.80 AverageDiameterofMold,inch2.810MassofTare, g93.00 MassofMold, g1048.00MoistureContent, %19.8 Trial #12 MassofMold+ Soil, g2623.00 o Massof Soil, g1575.00Temperature,C26.4526.22 3 Volumeof Soil, ft 0.02871ThermalResistivityReading,rho°C·cm/W43.9744.10 WetDensityofRemolded Soil,pcf120.9 AverageTh.ResistivityReading,rho°C·cm/W44.04 DryDensityofRemolded Soil,pcf100.9CalibrationThermalResistivityReading,rho101.40°C·cm/W o ActualDifference fromOMC, %2.1CalibrationTemperature,C25.53 Actual % Compaction fromMDD94.7CalibrationThermalResistivityFactor1.0020 Reported SoilThermalResistivity 44.12°C·cm/W o DeterminationofThermalResistivityat OvenDriedCondition(110C) TESTDATA(Specimen#4A) TESTDATA Trial #12 Remarks o Temperature,C ThermalResistivityReading,rho°C·cm/W AverageTh.ResistivityReading,rho°C·cm/W CalibrationThermalResistivityReading,rho101.40°C·cm/W o CalibrationTemperature,C25.53 CalibrationThermalResistivityFactor Reported SoilThermalResistivity NA°C·cm/W OvenID #496/610 Description NA BalanceID #563/700 Sensor ID #827 ConductivityMeter ID #826 Calibration Standard #SE2499 USCS(D2487;D2488)NA Calibration Value,rho 101.60°C·cm/WAASHTO(M145)NA T IMELY 1874Forge StreetTucker, GA 30084 E NGINEERING Phone: 770-938-8233 Tested ByRI/EB S OIL Fax:770-923-8973 Date08/29/19 T ESTS,LLC Web:www.test-llc.com Checked By ClientPr. #V1.440Lab. PR. #1999-04-1 Pr.NameSolarFarmDevelopmentS.TypeRemold Sample ID31383/SS-5 & SS-6Depth/Elev.- LocationB-1 & B-3 Add. Info- ASTMD5334 StandardTestMethodforDeterminationofThermalConductivity/Resistivityof Soiland SoftRock byThermalNeedle Probe Procedure SummaryofData Specimen #OvenDried 1234 MoistureContent, %0.0013.7415.9017.9219.84 ThermalResistivity,°C·cm/W143.2855.6050.8447.9844.12 ThermalResistivityDry-OutCurve 150.00 125.00 cm/W * 100.00 C ee r g e D , 75.00 y t ivi t is s e R50.00 l a m r e Th 25.00 0.00 0.02.04.06.08.010.012.014.016.018.020.0 MoistureContent, % Oven ID #496/610 ConductivityMeter ID 826 Balance ID #563/700 Calibration Standard SE2499 Sensor ID # 827 Calibration Value,rho 101.6°C·cm/W IMELY 1874 Forge Street Tucker, GA 30084 NGINEERING Phone: 770-938-8233 Tested By OIL Fax: 770-923-8973 Date ESTS, LLC Web:www.test-llc.com Checked By Client Pr. #Lab. PR. # V1.4401999-04-1 Pr. NameSolar Farm DevelopmentS. TypeBulk (Composite) Sample IDDepth/Elev. 31383/SS-5 & SS-6- LocationB-1 & B-3Add. Info- ASTM D 698 StandardTestMethod for Laboratory Compaction Characteristics of Soil Using 33 Standard Effort (12,400 ft-lbf/ft (600kN-m/m)) DETERMINATION OF TEST PROCEDURE wetdryMOISTURE CONTENT Coarse + FineCoarse 33800.028398.5 Mass of Soil before sieving, g FractionFraction Mass of Wet Sample & Tare, g 1925.837.0 Mass of Mat. Retained on No. 4 sieve, g Mass of Dry Sample & Tare, g 37.037.01671.537.0 Mass of Mat. Retained on 3/8" sieve, g Mass of Tare, g 334.50.0 Mass of Mat. Retained on 3/4" sieve, g Moisture Content, % 19.00.0 Material Retained on No. 4 Sieve, % 0.1 Material Retained on 3/8" Sieve, % B Material Retained on 3/4" Sieve, %Procedure 0.1 Total, %(oversized) TEST DATA 12345798 PointsMold ID Number 6022.06133.06167.06119.04261.8 Mass of Mold and Soil, gMass of Mold, g 3 506.5421.5431.2498.30.0333 Mass of Wet Sample & Tare, g Volume of Mold, ft 466.0379.2382.3441.2318 Mass of Dry Sample & Tare, gHammer ID Number 183.7125.2129.9182.225 Mass of Tare, gNumber of Blows per layer 14.316.719.422.03 Moisture Content, %Number of Layers 317 Mechanical Compactor ID Number 116.5123.9126.1123.0 Wet Density, pcf Method A:Material retained on No. 4 Sieve< 25% 101.9106.2105.7100.7 Dry Density, pcf Method B:Material retained on 3/8" Sieve < 25% Method C:Material retained on 3/4" Sieve < 30% Moisturevs. Dry Density 100% Saturation Curves: (Gs=2.6); (Gs=2.7); (Gs=2.8) 109.0 107.0 REMARKS cf , p 105.0 y it s n e D 103.0 DESCRIPTION y NA Dr 101.0 99.0 USCS (ASTM D2487; D2488) 14.015.016.017.018.019.020.021.022.023.024.0 NA AASHTO M145 Moisture Content, % NA 106.6 Corrected Maximum Dry Density, pcfNA Maximum Dry Density, pcf 17.7 Corrected Optimum Moisture Content, %NA OptimumMoisture Content, %