Loading...
HomeMy WebLinkAbout20130273 Ver 1_401 Application_2013031320130273 WT March 15, 2013 Ms. Karen Higgins Division of Water Quality THE 401 /Wetlands Unit 1650 Mail Service Center WOOTEN Raleigh, NC 27699 -1650 COMPANYRe: Pre - Construction Notification Application ENGINEERING Turkey Creek Sewer Replacement Project City of Raleigh, North Carolina P L A N N I N G TWC No. 2466 -BE ARCHITECTURE Dear Ms. Higgins: On behalf of the City of Raleigh, please find enclosed for your review the following items regarding the above referenced project. Please note that we do need written concurrence for 401 approval; however, we are requesting riparian buffer rule approval only. • Pre - Construction Notification Application • USGS maps showing location of project • SCS Soils maps showing location of project • Construction Drawings (reduced scale) showing buffer impact • Buffer Impact Exhibit This project proposes to construct approximately 463 linear feet (LF) of gravity sanitary sewer ranging in size from 8 to 36 -inch diameter. The project corridor begins approximately 350 feet southeast of the intersection of Hwy 70 (Glenwood Ave.) and Lynn Rd. The project corridor generally traverses southwest across Hwy 70 (Glenwood Ave.) and parallels Turkey Creek with the new gravity sewer. There are no stream crossings in this project as all new gravity sewer will parallel Turkey Creek. However, a small portion of the sewer will enter the Zone 2 stream buffer as shown in the attached application package. I trust this information is sufficient for your review; however, if you should have any questions or require additional information, please do not hesitate to contact us. We will provide any additional information or clarification needed immediately. Sincerely, THE WOOTEN COMPANY D %g erg 120 North Boylan Avenue Dustin Rhodes, E.I. 44 AR Raleigh NC 27603 -1423 Enclosures: As stated. A 919 828.0531 cc: Mr. Edward Stempien, P.E. — City of Raleigh, letter only fax 919 834 3589 TWC File NVWN4 A' y r Q `C Office Use Only: Corps action ID no. DWQ project no. Form Version 1.3 Dec 10 2008 Pre - Construction Notification (PCN) Form A. Applicant Information 1. Processing 1 a. Type(s) of approval sought from the Corps: ❑ Section 404 Permit ❑Section 10 Permit 1 b. Specify Nationwide Permit (NWP) number: NWP 12 or General Permit (GP) number: 1 c. Has the NWP or GP number been verified by the Corps? ❑ Yes ® No 1d. Type(s) of approval sought from the DWQ (check all that apply): ❑ 401 Water Quality Certification — Regular ❑ Non -404 Jurisdictional General Permit ❑ 401 Water Quality Certification — Express ® Riparian Buffer Authorization 1 e. Is this notification solely for the record because written approval is not required? For the record only for DWQ 401 Certification: ❑ Yes ® No For the record only for Corps Permit: ❑ Yes ® No 1f. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? If so, attach the acceptance letter from mitigation bank or in -lieu fee program. ❑Yes ® No 1 g. Is the project located in any of NC's twenty coastal counties. If yes, answer 1 h below. ❑ Yes ® No 1 h. Is the project located within a NC DCM Area of Environmental Concern (AEC)? ❑ Yes ❑ No 2. Project Information 2a. Name of project: Turkey Creek Sewer Replacement 2b. County: Wake 2c. Nearest municipality / town: City of Raleigh 2d. Subdivision name: N/A N/A LS W7@ 2e. NCDOT only, T.I.P. or state project no: 3. Owner Information MA 3a. Name(s) on Recorded Deed: City of Raleigh 3b. Deed Book and Page No. N/A - NA 3c. Responsible Party (for LLC if applicable): N/A 3d. Street address: One Exchange Plaza, Suite 620, 219 Fayetteville Street Mall 3e. City, state, zip: Raleigh, NC 27601 3f. Telephone no.: 919 - 996 -4540 3g. Fax no.: 919- 996 -4545 3h. Email address: Edward.Stempien@raleighnc.gov Page 1, of 10 PCN Form — Version 1.3 December 10, 2008 Version 4. Applicant Information (if different from owner) 4a. Applicant is: ❑ Agent ❑ Other, specify: 4b. Name: N/A 4c. Business name (if applicable): 4d. Street address: 4e. City, state, zip: 4f. Telephone no.: 4g. Fax no.: 4h. Email address: 5. Agent/Consultant Information (if applicable) 5a. Name: W. Brian Johnson, P.E. 5b. Business name (if applicable): The Wooten Company 5c. Street address: 120 N. Boylan Ave. 5d. City, state, zip: Raleigh, NC 27603 5e. Telephone no.: 919 -828 -0531 5f. Fax no.: 919 - 834 -3589 5g. Email address: bjohnson ®thewootencompany.com Page 2 of 10 PCN Form — Version 1.3 December 10, 2008 Version B. Project Information and Prior Project History 1. Property Identification 1a. Property identification no. (tax PIN or parcel ID): Linear Project 1 b. Site coordinates (in decimal degrees): Latitude: 35.870056 N Longitude: - 78.722675 W (DD.DDDDDD) (- DD.DDDDDD) 1c. Property size: Linear Project, appoximately 1/3 acres disturbed 2. Surface Waters 2a. Name of nearest body of water (stream, river, etc.) to Turkey Creek proposed project: 2b. Water Quality Classification of nearest receiving water: B; NSW 2c. River basin: Neuse 3. Project Description 3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: The existing conditions include a road crossing and open areas of commercial properties. 3b. List the total estimated acreage of all existing wetlands on the property: There are no existing wetlands on the affected property. 3c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property: Approximately 1,325 LF 3d. Explain the purpose of the proposed project: To improve sewer infrastructure in the Turkey Creek area by installing parallel sewer and abandoning existing sewer. 3e. Describe the overall project in detail, including the type of equipment to be used: The project will construct approximately 463 LF total new DIP gravity sewer line. Approximately 82 LF of 36 -inch DIP gravity sewer, 323 LF of 24 -inch DIP gravity sewer (130 LF being in 48 -inch steel encasement), and 58 LF of 8 -inch DIP gravity sewer will be constructed. The project will abandon existing deteriorated sewer infrastructure and extend existing sewer in two locations. Existing 24 -inch steel pipe gravity sewer will be abandoned and relocated with 24 -inch DIP and 24 -inch DIP in 48 -inch steel encasement. Existing 8 -inch sanitary sewer (on the HWY 70 W side) will be extended and connected to the new relocated sewer. Existing 24 -inch forcemain sewer (on the HWY 70 E side) will be extended and connected to the new 36 -inch gravity sewer. The project will prevent problems associated with the existing deteriorating sewer infrastructure along Turkey Creek. Equipment used will include a track hoe excavator, rubber tire front end loader and trucks. 4. Jurisdictional Determinations 4a. Have jurisdictional wetland or stream determinations by the Corps or State been requested or obtained for this property / project (including all prior phases) in the past? ❑ Yes ® No ❑ Unknown Comments: 4b. If the Corps made the jurisdictional determination, what type of determination was made? ❑ Preliminary ❑ Final 4c. If yes, who delineated the jurisdictional areas? Agency /Consultant Company: Name (if known): Other: 4d. If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation. n/a 5. Project History 5a. Have permits or certifications been requested or obtained for this project (including all prior phases) in the past? Yes ID No El Unknown 5b. If yes, explain in detail according to "help file" instructions. Page 3 of 10 PCN Form — Version 1.3 December 10, 2008 Version 6. Future Project Plans 6a. Is this a phased project? ❑ Yes ® No 6b. If yes, explain. Page 4 of 10 PCN Form — Version 1.3 December 10, 2008 Version C. Proposed Impacts Inventory 1. Impacts Summary 1 a. Which sections were completed below for your project (check all that apply): ❑ Wetlands ❑ Streams - tributaries ® Buffers ❑ Open Waters ❑ Pond Construction 2. Wetland Impacts If there are wetland impacts proposed on the site, then complete this question for each wetland area impacted. 2a. 2b. 2c. 2d. 2e. 2f. Wetland impact Type of jurisdiction number - Type of impact Type of wetland Forested (Corps - 404, 10 Area of impact Permanent (P) or (if known) DWQ - non -404, other) (acres) Temporary W1 ❑ P ❑ T N/A ❑ Yes ❑ Corps ❑ No ❑ DWQ 2g. Total wetland impacts 2h. Comments: 3. Stream Impacts If there are perennial or intermittent stream impacts (including temporary impacts) proposed on the site, then complete this question for all stream sites impacted. 3a. 3b. 3c. 3d. 3e. 3f. 3g. Stream impact Type of impact Stream name Perennial Type of jurisdiction Average Impact number - (PER) ) or (Corps - 404, 10 stream length Permanent (P) or intermittent DWQ - non -404, width (linear Temporary (T) (INT)? other) (feet) feet) S1 ❑ P ❑ T N/A ❑ PER ❑ Corps ❑ INT ❑ DWQ 3h. Total stream and tributary impacts 3i. Comments: 4. Open Water Impacts If there are proposed impacts to lakes, ponds, estuaries, tributaries, sounds, the Atlantic Ocean, or any other open water of the U.S. then individually list all open water impacts below. 4a. 4b. 4c. 4d. 4e. Open water Name of waterbody impact number - (if applicable) Type of impact Waterbody type Area of impact (acres) Permanent (P) or Tem ora 01 ❑P ❑T N/A 4L Total open water impacts 4g. Comments: 5. Pond or Lake Construction If pond or lake construction proposed, then complete the chart below. 5a. 5b. 5c. 5d. 5e. Pond ID Proposed use or purpose of Wetland Impacts (acres) Stream Impacts (feet) Upland (acres) number pond Flooded Filled Excavated Flooded Filled Excavated Flooded P1 N/A 5E Total 5g. Comments: Page 5 of 10 PCN Form - Version 1.3 December 10, 2008 Version 5h. Is a dam high hazard permit required? ❑ Yes ❑ No If yes, permit ID no: 5i. Expected pond surface area (acres): 5j. Size of pond watershed (acres): 5k. Method of construction: 6. Buffer Impacts (for DWO) If project will impact a protected riparian buffer, then complete the chart below. If yes, then individually list all buffer impacts below. If any impacts require mitigation, then you MUST fill out Section D of this form. 6a. ® Neuse ❑ Tar - Pamlico ❑ Other: Project is in which protected basin? ❑ Catawba ❑ Randleman 6b. 6c. 6d. 6e. 6f. 6g. Buffer impact number — Reason for Buffer Zone 1 impact Zone 2 impact Permanent (P) impact Stream name mitigation (square feet) (square feet) or Temporary required? 61 ®P ❑ T Trenching for Gravity Sewer Turkey Creek ❑ Yes ® No 0 1,119 6h. Total buffer impacts 0 1,119 6i. Comments: See Pre - Construction Notification spreadsheets that are attached to this application D. Impact Justification and Mitigation 1. Avoidance and Minimization 1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing project. New gravity sewer installed outside of buffer, where possible. New gravity sewer must intrude into buffer in order to tie back to existing gravity sewer. Ib. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques. Proper erosion control measures will be utilized, including silt fence, rock check dams, silt fence outlets, construction entrances and tree protection fencing. Upon completion of construction through the corridor, the easement will be seeded. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for ❑ Yes ® No impacts to Waters of the U.S. or Waters of the State? 2b. If yes, mitigation is required by (check all that apply): ❑ DWQ ❑ Corps ❑ Mitigation bank 2c. If yes, which mitigation option will be used for this project? ❑ Payment to in -lieu fee program ❑ Permittee Responsible Mitigation 3. Complete if Using a Mitigation Bank WA 3a. Name of Mitigation Bank: 3b. Credits Purchased (attach receipt and letter) Type Quantity Page 6 of 10 PCN Form — Version 1.3 December 10, 2008 Version 3c. Comments: 4. Complete if Making a Payment to In -lieu Fee Program WA 4a. Approval letter from in -lieu fee program is attached. ❑ Yes 4b. Stream mitigation requested: linear feet 4c. If using stream mitigation, stream temperature: ❑ warm ❑ cool ❑cold 4d. Buffer mitigation requested (DWQ only): square feet 4e. Riparian wetland mitigation requested: acres 4f. Non - riparian wetland mitigation requested: acres 4g. Coastal (tidal) wetland mitigation requested: acres 4h. Comments: 5. Complete if Using a Permittee Responsible Mitigation Plan WA 5a. If using a permittee responsible mitigation plan, provide a description of the proposed mitigation plan. 6. Buffer Mitigation (State Regulated Riparian Buffer Rules) — required by DWQ 6a. Will the project result in an impact within a protected riparian buffer that requires buffer mitigation? ❑ Yes ® No 6b. If yes, then identify the square feet of impact to each zone of the riparian buffer that requires mitigation. Calculate the amount of mitigation required. Zone 6c. Reason for impact 6d. Total impact (square feet) Multiplier 6e. Required mitigation (square feet) Zone 1 3 (2 for Catawba) Zone 2 1.5 6f. Total buffer mitigation required: 6g. If buffer mitigation is required, discuss what type of mitigation is proposed (e.g., payment to private mitigation bank, permittee responsible riparian buffer restoration, payment into an approved in -lieu fee fund). 6h. Comments: Page 7 of 10 PCN Form — Version 1.3 December 10, 2008 Version E. Stormwater Management and Diffuse Flow Plan (required by DWO) 1. Diffuse Flow Plan 1 a. Does the project include or is it adjacent to protected riparian buffers identified ®Yes C1 No within one of the NC Riparian Buffer Protection Rules? 1 b. If yes, then is a diffuse flow plan included? If no, explain why. Comments: No impervious area will be created as a result of the project. Erosion ❑ Yes ® No control devices will be used as necessary during construction. 2. Stormwater Management Plan 2a. What is the overall percent imperviousness of this project? 0% 2b. Does this project require a Stormwater Management Plan? ❑ Yes ® No 2c. If this project DOES NOT require a Stormwater Management Plan, explain why: No impervious area is created; the erosion and sedimentation control permit will be the only stormwater discharge permit required. 2d. If this project DOES require a Stormwater Management Plan, then provide a brief, narrative description of the plan: N/A ❑ Certified Local Government 2e. Who will be responsible for the review of the Stormwater Management Plan? ❑ DWO Stormwater Program ❑ DWQ 401 Unit 3. Certified Local Government Stormwater Review WA 3a. In which local government's jurisdiction is this project? ❑ Phase II 3b. Which of the following locally - implemented stormwater management programs ❑ NSW ❑ USMP apply (check all that apply): ❑ Water Supply Watershed ❑ Other: 3c. Has the approved Stormwater Management Plan with proof of approval been FOYes ❑ No attached? 4. DWO Stormwater Program Review WA ❑ Coastal counties 4a. Which of the following state - implemented stormwater management programs apply ❑ HQW ❑ ORW (check all that apply): ❑ Session Law 2006 -246 ❑ Other: 4b. Has the approved Stormwater Management Plan with proof of approval been attached? ❑ Yes ❑ No 5. DWO 401 Unit Stormwater Review WA 5a. Does the Stormwater Management Plan meet the appropriate requirements? ❑ Yes ❑ No 5b. Have all of the 401 Unit submittal requirements been met? ❑ Yes ❑ No Page 8 of 10 PCN Form — Version 1.3 December 10, 2008 Version F. Supplementary Information 1. Environmental Documentation (DWO Requirement) 1 a. Does the project involve an expenditure of public (federal /state/local) funds or the ® Yes ❑ No use of public (federal /state) land? 1 b. If you answered "yes" to the above, does the project require preparation of an environmental document pursuant to the requirements of the National or State ❑ Yes ® No (North Carolina) Environmental Policy Act (NEPA/SEPA)? 1 c. If you answered "yes" to the above, has the document review been finalized by the State Clearing House? (If so, attach a copy of the NEPA or SEPA final approval letter.) ❑ Yes ❑ No Comments: 2. Violations (DWO Requirement) 2a. Is the site in violation of DWQ Wetland Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), DWO Surface Water or Wetland Standards, ❑ Yes ® No or Riparian Buffer Rules (15A NCAC 2B .0200)? 2b. Is this an after- the -fact permit application? ❑ Yes ® No 2c. If you answered "yes" to one or both of the above questions, provide an explanation of the violation(s): 3. Cumulative Impacts (DWO Requirement) 3a. Will this project (based on past and reasonably anticipated future impacts) result in ❑ Yes ® No additional development, which could impact nearby downstream water quality? 3b. If you answered "yes" to the above, submit a qualitative or quantitative cumulative impact analysis in accordance with the most recent DWO policy. If you answered "no," provide a short narrative description. 4. Sewage Disposal (DWO Requirement) 4a. Clearly detail the ultimate treatment methods and disposition (non- discharge or discharge) of wastewater generated from the proposed project, or available capacity of the subject facility. The wastewater will be treated by the City of Raleigh WWTP located on the Neuse River. The City's existing system and treatment facility are adequate to handle the flow from this project since no new wastewater will be generated. Page 9 of 10 PCN Form — Version 1.3 December 10, 2008 Version 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or ❑ Yes ® No habitat? 5b. Have you checked with the USFWS concerning Endangered Species Act ❑Yes ®No impacts? 5c. If yes, indicate the USFWS Feld Office you have contacted. [:1 Raleigh ❑ Asheville 5d. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? Wake County Endangered Species, Threatened Species, and Federal Species of Concern 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as essential fish habitat? ❑ Yes ® No 6b. What data sources did you use to determine whether your site would impact Essential Fish Habitat? Wake County Endangered Species, Threatened Species, and Federal Species of Concern 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation ❑ Yes ® No status (e.g., National Historic Trust designation or properties significant in North Carolina history and archaeology)? 7b. What data sources did you use to determine whether your site would impact historic or archeological resources? NC State Office of Archeology, National Register of Historic Places 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA- designated 100 -year floodplain? ® Yes ❑ No 8b. If yes, explain how project meets FEMA requirements: all piping is below ground; manhole rims located in the 100 -year floodplain are water tight or 2 feet above the floodplain 8c. What source(s) did you use to make the floodplain determination? www.ncfloodmaps.com J. Russell Allen, City Manager City of Raleigh Post Office Box 590 Raleigh, North Carolina 27602 U Applicant/Agent's Printed Name /Applicant/Agent's Signature Date (Agent's signature is valid only if an authorization letter from the applicant is provided.) Page 10 of 10 PCN Form — Version 1.3 December 10, 2008 Version I I LINA — SHEET NUMBER 27 cer Ge82 (Joins sheet i 8 ) Agc2 c 27 C7 9 Cn CBB g r era �ti vY �� N i C r �� �i` Cn z CgB CKB2 Ptil` i APD D CeF e GeB / 1 8) A C ; WY \(eD CCCCe© f AgC2 v „. :` A8C2 t A CgB2 r GeG2 AgGt F r ti .Cef7 CgC 4 t AgC CeB2(� a t l t } to % CgC2 n FgC2 �� to 'o" LL VaB2 °` 9� t r . Ge82 cgC2 .SGT �� gC2 aC2 , Eno2 V f A C2 G88 . (Cg CgC C \i ApO `A s { `r Cg82 CgB - CgB f. fi Wt *tEf . wF p t. Ca F Snc "T t ' CBD, C8C2 ' !E3 `@tiw' CeD C i c r`__.. " eF WY A ' ORBA Gev C4 YVXF Getz ar PDT E_ ,�y O gL2 Z.. Ln EnB2 eF r+ P O .. /r D 7, ~ EEEEE SS G1 CgB2 CeF e i r fn - EnB2 s I C982 ry y °o f EnC2 e WwF .. [IC? 4.; nC2 .. C) \ C¢ C &B2 < UP, i 4 ? e o - `\ GeC A gc, n87 1 ErlU 1\ , \ s' p e'IC2 CgB2 '/` GrB2 GeB S EnC1 EnC2 cgG2 CeF ` nC CAB m O r• CgG CgC AgG2 U� \ ✓ v wF I •� , CRC a M C962 CeF Cep CeF o j CgB2 gC tie V� o CeE> _ APC CeF a " GRCZ y L' ,_ LL � •gC CgC Cp;B2 CgC r r .C8$ GeF WwF AfA i w 1 g Cm r °� Gr?C2 Enti2� , eD7 nC2 �� j CAC } o f} m CgB CeD _ GeF J Ge cec EnD2 " !. _ CeF CgB2 GCRC? <� CgC CgB) } g8 C C:t t t4ttJ1j1 .WmE WkE CgC2 (Joins sheet 37) Also see Sheep °ry �M; l C2 F 'z ° Cg62 Cg Cep Gtov IwF +:C rch °o CBB2 ` Al CgC2 AgC2 AgC2 Cg62 `- i i �CgC2 AgC2 T A CgC2 �E ' C61 qp ,,�- i sn AgB2 v , CF69�� AgC2 A D d'�_ APb AgC2 -- (Joins sheet 38) "E r, �-- Also c' Sheet 27 p See Ouffer rmpac Exhibit -For Close -Up b 11 U 0 ct m Y Q. 0 m m a10 ryN N o, M o a y a QP st Public City of Ralsig Sewer Collection / Extension System s.a...l aw �"a ayww�. e,e... xto„I,s...,,a I Halt LP' pet�e�q Let ro.. Tres.. Tro//¢ f 44- ' NOTES 1. PRIOR TO CONSTRUCTION, LOCATE EX. 16" WATERLINE BOTH HORIZONTALLY AND VERTICALLY AT CROSSING OF PROPOSED 24" SEWER. PROVIDE ENGINEER WITH INFORMATION ON FINDINGS AND NOTIFY ENGINEER OF POTENTIAL CONFLICT. - ProPwfY o/- Ex. EMcMic /helms I `.. ._... 315- ""'"" WS for "_ N/F _Ober*, M,aafa LLC 3R2 Cogg/es Cetus uctle, Co. SILT FENCE The City of Raleigh consents to the connection and extension of TasxsapKSnon srrtvxas: the City's public sewer system as shown on this plan. The material ° '+Ta^'se H I JkJ•T"k, Signal VoWr I Ex. Electric /7raf /le S:'onal Cables J 3'x3'Tiu/Rc S)gnwvewt 2. REMOVE EX. 24" SANITARY SEWER STEEL PIPE THROUGH THE EX. BOX CULVERT FROM NEW 24" PLUG (SOUTH SIDE) TO NEW 24" PLUG (NORTH SIDE). PRIOR SSW •162 1' 215. 21' 04 , - - rc,- 303.86_ 40' PERMANENT Mv. Out- 292.29 - - ITY EASEMENT and consbuctlon methods used for this project shall c mform to the TpxawaTax 24" SANITARY SEWER os ' \ ProPwfy of TO REMOVAL, PUMP OUT WASTEWATER TO EMPTY SEWER. PROPERLY DISPOSE OF EX. SEWER PIPE. NYF J.R. Adams \ Cot IA - Grove Bwton DO: 3166, PC: 0050 on BOY: 1995, PC: 1555 standards and apecMcatlons of the City's Public Utilities Handbook 3 n 3. EX. MANHOLES 119, 120 & 183 TO BE ABANDONED. REMOVE MANHOLE COVERS AND MANHOLES TO 3' BELOW EX. GRADE. BACKFILL REMAINING PORTION OF 310 t.. ....................... . ..._ia ... t N �* 1 310 .; .. E City of Raleigh I .... 1 MANHOLES TO MATCH EX. GRADE. w ra 305: Public Utilities Department Permit # esx roxastxr: ��°k, I I I 4. REPAIR RIP -RAP ALONG CREEK BANK. RIP -RAP SHALL BE REPAIRED WITH EQUAL SIZE /DEPTH TO EXISTING. O y 300 . .... Authod,atlon to Construct 300. Ex T p/ae ' / SroR. ; .... 295 ..... .... ........ ......... ........ Data 295 ........... .. . (/) Q ' ....... .. 5. PROVIDE CONSTRUCTION ENTRANCES ON EACH SIDE OF GLENWOOD AVENUE. / \ GENERAL. NOTES DRILL E%. MANHOLE....... .. .. .- .. SUGGESTED SEQUENCING 1 \ _ 7J r � i.. \♦ � \ 1. LOCTION OF EXISTING UTILITIES SHOWN ON DRAWINGS ARE APPROXIMATE. CONTRACTOR SHALL CONTACT THE UTILITY OWNERS TO LOCATE ALL ELECTRICAL COMMUNICATION, TV CABLES, GAS LINES AND OTHER UTILITIES AT LEAST 48 HOURS PRIOR TO COMMENCING WORK. CONTRACTOR RESPONSIBLE FOR VERIFYING EXACT LOCATION OF THESE EXISTING 290 y1 1. THIS IS A SUGGSTED SEQUENCING PLAN. CONTRACTOR TO UTILITIES. THE COST TO REPAIR THESE FACILITIES IF DAMAGED, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 285.: ...... n...: .. r .... SUBMIT SEQUENCING PLAN TO ENGINEER AND CITY OF Ex. Eberrie/Tro/fic RALEIGH PRIOR TO BEGINNING CONSTRUCTION FOR APPROVAL. S;grwlc,.a 20�ii Pp Q ^ ; q� i� \ 2. EXISTING UTILITY OWNERS INCLUDE. BUT NOT LIMITED TO: 280...: ._ 2. INSTALL SEWER FROM MANHOLE 2 TO MANHOLE 3. EXTEND Topes -30e is LF OF 24 ............. 280 %. ���,,,, - „'� \ 7/� p_ . D TIME WARNER CABLE IV) AT &T ..I.. .. _ .. N H + .. .. 275.. ._ 51, LK UPSIRLAM AND DOWNSTREAM,BUT DO NOT CONNECT TO EXSITING SYSTEM. 3. SET UP TEMPORARY BYPASS PUMPING FORM EX. MANHOLE 162 TO MANHOLE 210. INSTALL REMAINING SEWER: MAKE CONNECTIONS AND DISCONNECTIONS. TEST AND CERTIFY TIO S. ES E NEW SEWER. UPON APPROVAL, RELEASE PLUGS /TEMPORARY BYPASS INTO NEW SEWER. 4. ABANDON EXISTING SEWER AS SHOWN. REMOVE EXISTING 24" STEEL SEWER THROUGH BOX CULVERT AND PROPERTY DISPOSE. 5. CLEANUP, REPLACE RIP -RAP AND SEED DISTURBED AREAS. NEW 24" SANITARY SEWER VV SSMN OBJ (SEE ABANDONMENT NOTES) Top - 306.19 Mv. M -29OJ2 Mv. M- 287.78 (56'•OtP.) )nv. Out- 286.JJ MANHOLE No .2 BEGIN 4118 STA. 20.00.00 4118.01' 21" MANHOLE NO.2 - tlL184. 37' -2W Ti.:Ir NEW 36" SAN ARY SEWER y skj:,. NEW PERMANENT UTILITY EASEMENT (WIDTI VARIES) of 2g, I-S MANHOLE NO .1 Pr 'y o/ N(FPQ z�)rome Lym, LLC BEGIN STA. W 3p5 lfi / oPSl Space) 4203.53 08 D81 14484, Lynwood Gt0 IOM• 7012, PC: 350 / BUS fff �. / �NWSa Shin r , Zon / / / ✓p / /.,,/_ #K . ' s R�7BM -19 ' PKS %' Tree A-, t) !" SSA#/ •2N) Top -3Y.6D 24" SANITARY SEWER EXTENSION Halt LP' pet�e�q Let ro.. Tres.. Tro//¢ f 44- ' ._ M- 285.503 � - ProPwfY o/- Ex. EMcMic /helms I `.. ._... 315- ""'"" WS for "_ N/F _Ober*, M,aafa LLC 3R2 Cogg/es Cetus uctle, Co. SILT FENCE AILS -\ q3� °±'ryy rryr4y H DE. 21778, PG: 1583 IOM: 1997, PG: 1397 JkJ•T"k, Signal VoWr I Ex. Electric /7raf /le S:'onal Cables J I � ToP-JO#.97 'ssMN •roar 1 ITOP-J06.11 Ex. MANHOLE NO. 182 ij Ex. MANHOLE NO. 143 END STA 20.38.59 F)/ END STA. 10 +72.65 4.15% , 45" 4179.11' 37" !Ex. B" Sbrtitor Sewer' Ex-Wingwap. �: -,I KEY NEW 18" PLUG NwtlwPB '� a.._I ••CREEK SSMH •120 (SEE ABANDONMENT NOTES) Ea. Needwoll�' To -308.90 Ex. 1�" SteelPfpe � x.'-300 � Mv. fC /L)- 282.90 x N /verl _ _ T- x�ypG .,..o .., 6•x8'BP ____�_ _ ^", - {,_- .- _ -' -::. �'.y,� SSW •119 (SEE ABANDONMNT NOTES) -...F. 1PROVIDE 130 LF OF 24" D.I. PIPE Ex. M" Water( (APP /ox. LocafioN >� •� wWy J'x3'7iefr Soxx Vmdt LT WZIL62 (PROTECTED 401 LINED. CAR RIER PIPE IN 130 LF OF 48" STEEL sx3•rrof/ie signor vwI 50 25 0 50 too 150 1 SCALE: I = 50 GLENWOOD AVENUE CROSSING 10.00 11.00 12.00 13.00 Proper N/F J.R. Adams L ot M - Drove Bot, OB: JI66, PC: 0050 BOY' 1995. PC: 1555 24" SANITARY SEWER EXTENSION EWER -' } 44- ' tMANHOLE N0. 3 p .51.20• 51' 3 4 N . ...... ........................ {...... ..._..... ..... ..... ... I OLE N0. 3 BEGIN STA. 30.00.00 320 494.55' 45" AILS -\ q3� °±'ryy rryr4y H SILT FENCE 3'x3'Tiu/Rc S)gnwvewt 1PROVIDE 130 LF OF 24" D.I. PIPE Ex. M" Water( (APP /ox. LocafioN >� •� wWy J'x3'7iefr Soxx Vmdt LT WZIL62 (PROTECTED 401 LINED. CAR RIER PIPE IN 130 LF OF 48" STEEL sx3•rrof/ie signor vwI 50 25 0 50 too 150 1 SCALE: I = 50 GLENWOOD AVENUE CROSSING 10.00 11.00 12.00 13.00 Proper N/F J.R. Adams L ot M - Drove Bot, OB: JI66, PC: 0050 BOY' 1995. PC: 1555 24" SANITARY SEWER EXTENSION t ................. .. ... BuFy _... _................. nF q _ . ...... ........................ {...... ..._..... ..... ..... ... ...... ..._ 320 a AILS -\ q3� °±'ryy rryr4y H o ANHOLE NO 4 ?-a- - NO STA.. 13-71.69, "c ^- SSW •162 1' 215. 21' 04 , - - rc,- 303.86_ 40' PERMANENT Mv. Out- 292.29 - - ITY EASEMENT ..... ..... .:..... 24" SANITARY SEWER os \ ProPwfy of NYF J.R. Adams \ Cot IA - Grove Bwton DO: 3166, PC: 0050 on BOY: 1995, PC: 1555 ..... n III YbNI: V) t:I I T Ut KPLLI H PUNLIG U I ILl I ILJ IID PROGRESS ENERGY 3. THE LIMITS OF DISTURBANCE ARE THE ROAD RIGHTS -OF -WAY AND EASEMENTS (EXISTING, PROPOSED AND TEMPORARY). 4. THE CONTRACTOR SHALL TAKE PRECAUTIONS NOT TO DISTURB EXISTING PROPERTY CORNER MARKERS. PROPERTY CORNERS R/W LINES AND EASEMENTS SHALL BE CLEARLY MARKED FOR CONSTRUCTION LIMITS. ALL DISTURBED PROPERTY CORNERS SHALL BE REPLACED BY A REGISTERED LAND SURVEYOR AT NO ADDITIONAL COST. 5. TEMPORARILY REMOVE MINOR ITEMS AS REQUIRED FOR THE INSTALLATION OF THE UTILITY, MINOR ITEMS SHALL INCLUDE, BUT ARE NOT LIMITED T0, EXISTING SIGNS, MAIL BOXES, AND STORM SEWER PIPES. REINSTALL ITEMS TO THEIR ORIGINAL CONDITION. INCLUDE COST IN THE PER FOOT COST OF THE UTILITY BEING INSTALLED. 6. SUPPORT EXISTING POLES, FENCES, CULVERTS, PAVEMENT, UTILITIES, CURBING AND OTHER STRUCTURES (INCLUDING STORM DRAIN PIPE) DURING CONSTRUCTION. REPAIR DAMAGED ITEMS TO THEIR ORIGINAL CONDITION AT NO ADDITIONAL COST. 7. SUPPORT EXISTING STORM DRAIN PIPES OR REMOVE AND REPLACE. IF REMOVING AND REPLACING, SUBMIT MEANS AND METHOD TO ENGINEER PRIOR TO REMOVAL. B. EXCAVATED MATERIAL SHALL NOT BE PLACED ON THE ROADWAYS AT ANYTIME. 9. ALL BYPASS PUMPS USED DURING CONSTRUCTION SHALL HAVE SOUND ATTENUATING EQUIPMENT TO REDUCE NOISE DISTURBANCE TO NEARBY RESIDENCES. 10. ALL CONSTRUCTION SHALL ADHERE TO THE CITY OF RALEIGH STANDARD SPECIFICATIONS FOR SANITARY SEWER CONSTRUCTION. 11. NO EQUIPMENT SHALL BE ALLOWED IN THE CREEK BED. FOR CONSTRUCTION OR ACCESS PUPOSES. TREE PROTECTION NOTES 1. TREE PROTECTION FENCING SHALL BE PROVIDED ALONG ALL CLEARING /CONSTRUCTION LIMITS OUTSIDE OF R /W. ALL OPEN SPACE, PERIMETER BUFFERS AND OPEN SPACE THAT CONTAIN NATURAL FOREST AREA MUST REMAIN WOODED AND FENCED OFF FROM ACTIVE DEVELOPMENT WITH TREE PROTECTION FENCING. SEE SHEET NO. 10 FOR FENCING DETAIL. 2. TREE PROTECTION FENCING MUST BE INSTALLED AND INSPECTED PRIOR TO ANY GRADING ACTIVITY, INCLUDING THE CLEARING FOR EROSION CONTROL MEASURES. THE INSTALLATION OF TREE PROTECTION FENCING SHALL BE THE FIRST CONSTRUCTION ACTIVITY THAT OCCURS IN THE FIELD. 3. TREE PROTECTION FENCING SHALL BE MAINTAINED ON SITE UNTIL ALL WORK IS COMPLETED. 8" SANITARY SEWER EXTENSION 30.00 31.00 z U F ovli c¢ Q V z W Z d U y ot~qu x w & OFC Or Ld - 0C r2j Gi OOFa - °r oLL rn 9 � to u Z U ¢ cq W try U t' t++ I$y N y } I cc H Z~ F Q z a � v DESIGNED BY: WBJ DRAWN BY: EBM CHECKED BY: WEU PROJECT NO.: 2488 -BE DATE: FEBRUARY 2013 SCALE: HORZ.: 1•.50' VERT.: P.5' s1EET 2 OF 4 24" SANITARY SEWER EXTENSION t ................. .. ... .................................. ............................... ... _ .... ............................... _................... , ... .. __.._. _... _................. nF q _ . ...... ........................ {...... ..._..... ..... ..... ... ...... ..._ 320 a 320 N N............... i...... ....................... 315 ............._ .................... ...... ......... : ............ ............ .....:,.............. ................._............V .. .......... .......... .......... ..... .... ..... .... ......... .............i....... ........ d. ..... ..... ..... .........1......_....._ .. .._..__....................... ..... ..... .:..... ..... ..... ..........; 315 on ..... .. ...... ..... n 310 t.. ....................... . ..._ia ... t N �* 1 310 .; .. E I .... 1 ra 305: ��°k, 100 YR FLOOD EL -299 e 305 300 . .... . 300. Ex T p/ae ' / SroR. ; .... 295 ..... .... ........ ......... ........ .................... ....... 295 ........... .. . ,.__ ' ....... .. ;___ .._..CORE DRILL E%. MANHOLE....... .. .. .- .. REBULD E% INVERT ...... .... 290 ` ... E 2,' Swx(wy 290 y1 285.: ...... n...: .. r .... 285 280...: ._ .......... ; .._._.38.59 LF OF 24 ............. 280 PIPE 01.06% ..I.. .. _ .. N H + .. .. 275.. ._ i _.__:: :. . _..:_ ._ : ::. ,_.._ W _ .. _ 275. ; _.. _... 20.00 21.00 8" SANITARY SEWER EXTENSION 30.00 31.00 z U F ovli c¢ Q V z W Z d U y ot~qu x w & OFC Or Ld - 0C r2j Gi OOFa - °r oLL rn 9 � to u Z U ¢ cq W try U t' t++ I$y N y } I cc H Z~ F Q z a � v DESIGNED BY: WBJ DRAWN BY: EBM CHECKED BY: WEU PROJECT NO.: 2488 -BE DATE: FEBRUARY 2013 SCALE: HORZ.: 1•.50' VERT.: P.5' s1EET 2 OF 4 Turkey 4 1254 L�5 r 295 T URKE Y C _._ -" SANITARY SEWER CREEK. (WIDTH VARIES) %tree N 0. 1 ,i f 3'i5 E TYPE �'�. 8 � FA. 10 +00. -' R P y )3108 "Id 9 2 e _ 40 _; pp Zone— 3�/ .�� 'x o ,� •` ' -- Q 8 " Map le ROW 2 NL S _ on e o r Z PKS .� 10 Tree -BM # 199 10 " Oak �' 6" Tree NL S Creek Sewer Replacemen+ Buffer J:rn p a cfs Exh 1 bi+ v) . _r , 1, ,_� J, Inv. In 29 �. 39 �, v �, o - Inv. Out 291.29 Out= 291.29 _ NEW r CPED _ 1. s s Woods ., o 0 s us e -- � � 24 PLUG - -- Ex. win 9 well F Q ' SSMH # 143 eu e NEW o Top = 308.46 �- r. 24 PLUG k In v. C (C/L> =29 7.66 y NL S h. r E _ _ — NI ,310 _ .. ' s NEW 24" MAC ----- Q) � --� LUG o 31 ' ENC • ,� o MANHOLE NO. 3 9?, I _ .... . NEW a� S TA . 12 +51. 29 , o� p E -E 162° 51' 35" UTILIT As halt LP Parking L o t E NEW L IBS 10" Tree _ _ MANHOLE NO 3