Loading...
HomeMy WebLinkAbout20201874 Ver 1_FAY1012-CHURCH-20210514 COMBINED SET-REV_20210520INDEX OF SHEETS SHEET NO. DESCRIPTION G-01 COVER SHEET G-02 GENERAL NOTES REV. 5/14/21 G-03 SITE ACCESS REV.5/14/21 VX-01 EXISTING CONDITIONS VX-02 EXISTING SITE PLAN CSG-01 SITE & GRADING PLAN CSW-01 PROPOSED SITE PLAN CSW-02 PROPOSED WALL ELEVATION CSW-03 WALL SECTION A CSW-04 WALL SECTION B CSW-05 DETAILS CSW-06 DETAILS CSW-07 DETAILS CSW-08 DETAILS DT-01 DETAILS REV. 5/14/21 CITY OF FAYETTEVILLE 0 C — ST. JOHNS CHURCH DSR NO. 37-08-18-5038-501 STREAM BANK STABILIZATION/ WALL DESIGN DRAWINGS FAYETTEVILLE, NORTH CAROLINA PROJECT LOCATION REVISIONS: VICINTY MAP SCALE: 0 1000 2000 SCALE IN FEET W 0 U SHEET G-01 z C3 Z:IPROJECTSIFAY110121DESIGNIDRAWINGSIProject\BEAVER LAW Et ST. JOHNIb-Sheets\FA Y1012-CHURCH-G02.dgn PROJECT DESCRIPTION THIS PROJECT IS LOCATED AT 230 GREEN STREET IN FAYETTEVILLE, NC. THE PROJECT INVOVLES THE INSTALLATION OF STREAM BANK STABILIZATION STRUCTURES AND PARTIAL RECONSTRUCTION OF THE EXISTING BEAVER LAW PARKING LOT. APPROXIMATELY X.X ACRES OF LAND WILL BE DISTURBED FOR THE CONSTRUCTION OF THE STREAM BANK STABILIZATION AND PARKING LOT RECONSTRUCTION WITHIN THE LIMITS OF CONSTRUCTION SHOWN ON THE PLANS. ALL DISTURBED AREAS WILL BE SODDED OR OTHERWISE STABILIZED AS INDICATED ON THE DRAWINGS. EROSION CONTROL MEASURES WILL BE PLACED WITHIN THE LIMITS OF CONSTRUCTION AT STRATEGIC LOCATIONS TO INHIBIT THE FLOW OF STORMWATER RUNOFF ONTO SITE AND PROHIBIT THE FLOW OF SEDIMENT OFF SITE. EXISTING CONDITIONS SURVEY SITE COORDINATE CONTROL AND EXISTING CONDITIONS SHOWN FROM A TOPOGRAPHIC SURVEY OF THE PROPERTY PERFORMED BY JOYNER KEENY, INC. IN SEPTEMBER AND DECEMBER 2020. SOILS GEOTECHNOLOGIES, INC. COMPLETED A SUBSURFACE INVESTIGATION OF THE SITE IN DECEMBER 2009. THE FOLLOWING IS AN ABBREVIATED SUMMARY OF THE SUBSURFACE CONDTIONS: SOILS ON THE SITE WERE CHARACTERIZED BY THE PRESENCE OF CLEAN FILL MATERIAL TO SILTY AND CLAYEY SANDS EXTENDING TO DEPTHS OF ABOUT 6 FEET BELOW EXISTING GRADE. UNDERLYING THE FILL MATERIALS, SOILS CONSIST OF SILTY AND CLAYEY SANDS TO DEPTHS OF APPROXIMATELY 9.5 TO 12 FEET BELOW GRADE. UNDERLYING THE SANDS, LOW TO MODERATELY PLASTIC CLAYS WHICH EXTENDED TO DEPTHS RANGING FROM ABOUT 24 TO 28 FEET BELOW EXISTING GROUND SURFACE WERE ENCOUNTERED. UNDERLYING THE CLAYS, DENSE CLAYEY SANDS TRANSITIONING INTO HARD TO VERY HARD SILTS AT 28 TO 29 FEET. ONE BORING DID NOT ENCOUNTER THE SANDS AND INSTEAD THE CLAYS TRANSITIONED INTO VERY HARD SILTS AT 28 FEET. ALL BORINGS WERE TERMINATED AT APPROXIMATELY 30 FEET IN HARD TO VERY HARD SILTS. PLANNED SEDIMENTATION AND EROSION CONTROL PRACTICES 1. SEDIMENT FENCE : DESCRIPTION, CONSTRUCTION SPECIFICATIONS, AND MAINTENANCE AS PER DETAIL(S). 2. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE : DESCRIPTION, CONSTRUCTION SPECIFICATIONS, AND MAINTENANCE AS PER DETAIL(S). 3. CONCRETE BLOCK WALL Et RIPRAP EMBANKMENT STABILIZATION: DESCRIPTION, CONSTRUCTION SPECIFICATIONS, AND MAINTENANCE AS PER DETAIL(S). 4. FERTILIZING, SEEDING AND MULCHING : TO BE INSTALLED AS PER TEMPORARY AND PERMANENT SEEDING SPECIFICATIONS. SEE SEEDING SPECIFICATIONS ON THE CONTRACT DOCUMENTS. REFER ALSO TO SECTIONS 6.10 AND 6.11 OF THE NCDENR EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. MAINTENANCE : RESEED AND MULCH AREAS WHERE SEEDING EMERGENCE IS POOR, OR WHERE EROSION OCCURS, AS SOON AS POSSIBLE. DO NOT MOW. PROTECT FROM TRAFFIC AS MUCH AS POSSIBLE. MAINTENANCE PLAN 1. ALL EROSION CONTROL PRACTICES WILL BE CHECKED DAILY FOR STABILITY AND OPERATION AND FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL. ANY NEEDED REPAIRS WILL BE MADE IMMEDIATELY TO MAINTAIN ALL PRACTICES AS DESIGNED. 2. SEDIMENT WILL BE REMOVED FROM SEDIMENT CAPTURING MEASURES WHEN IT BECOMES ABOUT 0.5 FT DEEP. SEDIMENT CAPTURING MEASURES WILL BE REPAIRED AS NECESSARY TO MAINTAIN ADEQUATE BARRIERS AND SEDIMENT STORAGE. 3. ALL UTILITY TRENCHES ARE TO BE PROTECTED FROM WATER INFILTRATION. 4. SPOIL PILES ARE TO BE CONTAINED AT ALL TIMES. 5. ALL SEEDED AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED ACCORDING TO THE SPECIFICATIONS TO MAINTAIN A VIGOROUS, DENSE VEGETATION COVER. IF SEEDING FAILURE OCCURS, THOSE AREAS SHALL BE RESEEDED WITH ANNUAL VEGETATION, SUITABLE FOR THE TIME OF YEAR FOR TEMPORARY STABILIZATION AND PREPARED FOR PERMANENT SEEDING. SEEDING AND MULCHING WILL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATION. EROSION CONTROL REGULATION 1. EROSION AND SEDIMENTATION CONTROL MEASURES SHALL CONFORM TO THE REQUIREMENTS OF THE NORTH CAROLINA ACT OF 1973 AND LOCAL EROSION AND SEDIMENT CONTROL REQUIREMENTS. 2. TEMPORARY AND PERMANENT EROSION CONTROL MEASURES SHALL BE PROVIDED AS SHOWN ON THE PLANS OR AS DIRECTED BY THE ENGINEER. TEMPORARY SEDIMENT CONTROL DEVICES MUST BE INSTALLED TO THE EXTENT POSSIBLE PRIOR TO INITIATION OF GRADING AND EXCAVATION. THE DEVICES MUST BE MAINTAINED AT A MINIMUM OF 50% OF THE ORIGINAL SEDIMENT STORAGE CAPACITY AND MAY NOT BE REMOVED UNTIL THE AREAS THEY SERVE HAVE BEEN STABILIZED. 3. PURSUANT TO G.S. 113A-57(2), THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OR OTHER ADEQUATE EROSION DEVICES OR STRUCTURES. IN ANY EVENT, SLOPES LEFT EXPOSED WILL, WITHIN 21 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY OR PERMANENT GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION. 4. PURSUANT TO G.S. 113A-57(3), PROVISIONS FOR PERMANENT GROUND COVER SUFFICIENT TO RESTRAIN EROSION MUST BE ACCOMPLISHED FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. 5. ALTHOUGH THE GENERAL STATUTES DESCRIBED IN NOTES 3. AND 4. STILL APPLY, EFFECTIVE AUGUST 3, 2011, THE NC DIVISION OF WATER QUALITY NPDES GENERAL PERMIT FOR CONSTRUCTION ACTIVITIES (NGC010000) REQUIRES THAT GROUND STABILIZATION OF DITCHES, PERIMETER AREAS, AND SLOPES 3H:1V OR STEEPER SHALL BE ACHIEVED WITHIN 7 DAYS OF TEMPORARY OR PERMANENT CESSATION OF LAND DISTURBING ACTIVITIES. GROUND STABILIZATION OF ALL OTHER AREAS SHALL BE ACHIEVED WITHIN 14 DAYS OF TEMPORARY OR PERMANENT CESSATION OF LAND DISTURBING ACTIVITIES. CONSTRUCTION SEQUENCE 1. THE CONTRACTOR SHALL NOTIFY THE ENGINEER SEVEN (7) DAYS BEFORE COMMENCING ANY LAND DISTURBING ACTIVITY. INSTALL APPLICABLE EROSION AND SEDIMENT CONTROL MEASURES PRIOR TO THE ONSET OF ANY LAND DISTURBING ACTIVITY. 2. VERIFY ALL APPLICABLE PERMITS AND APPROVED PLANS ARE POSTED ON SITE. 3. PERFORM A WALK THROUGH TO VERIFY THAT ALL EROSION CONTROL DEVICES (ECD'S) AND BEST MANAGEMENT PRACTICES (BMP'S) ARE INSTALLED AS DESIGNED AND ARE FUNCTIONAL. 4. MOBILIZE EQUIPMENT TO WORK ZONE AND UTILIZE CONSTRUCTION ACCESS AREA TO ACCESS PROPOSED WALL LOCATION AND BRING IN MATERIALS TO BUILD WALL. 5. ONCE ON SITE, PERFORM A TOOLBOX SAFETY MEETING WITH ALL ON -SITE PERSONNEL IN ACCORDANCE WITH A SITE SPECIFIC JOB SAFETY ANALYSIS (JSA) 6. BEGIN CLEARING, GRUBBING, AND EARTHWORK AS REQUIRED FOR PIPE CONSTRUCTION. 7. REMOVE RUBBLE AND TREES AS REQUIRED FOR CONSTRUCTION. DISPOSE OFF SITE. 8. AFTER ALL WORK ACTIVITIES ARE CLARIFIED AND UNDERSTOOD, THE FOLLOWING STEPS SHALL BE IMPLEMENTED TO COMPLETE THE WALL CONSTRUCTION PER THE EXECUTION SECTION (PART 3) OF THE PROJECT SPECIFICATIONS. A. INSTALL TEMPORARY WATER DIVERSION STRUCTURE AND PREPARE WORK AREA AT BASE OF SLOPE ONCE THE WORK ZONE IS FREE OF STANDING WATER. B. IDENTIFY BLOCKS NEEDING NOTCHES FOR 4" DRAINPIPES. CORE NOTCHES IN BLOCKS AND SET ASIDE PRIOR PLACING ON WALL. PREPARE PRIOR TO EXCAVATING SLOPE TO MINIMIZE AMOUNT OF TIME EXCAVATED SLOPE IS EXPOSED. C. EXCAVATE TEMPORARY SLOPE TO FACILITATE WALL CONSTRUCTION AS SHOWN IN THE PLANS WITHIN GRADING LIMITS OF THE PROJECT. D. EXCAVATE WALL FOUNDATION SUBGRADE AND RIP RAP KEY IN FRONT OF WALL AND ALLOW OWNERS ENGINEER'S REPRESENTATIVE TO OBSERVE FOUNDATION SUBGRADE CONDITIONS ARE PREPARED IN ACCORDANCE WITH SPECIFICATIONS AND AS ANTICIPATED BY THE DESIGN ENGINEER. E. PLACE NON -WOVEN GEOTEXTILE ON WALL FOUNDATION SUBGRADE AND ON TEMPORARY EXCAVATION SURFACE, SECURING TO THE SLOPE AS NEEDED. F. CONSTRUCT LEVELING PAD. CONTRACTOR TO CONFIRM ALIGNMENT AND GRADE BY MEANS OF SURVEY PRIOR TO LAYOUT OF BOTTOM ROW OF BLOCKS. G. PLACE PRECAST MODULAR BLOCKS AND WALL INFILL PLACEMENT FOLLOWING STEPS IN SECTION 3.04 AND 3.05 OF THE PROJECT SPECIFICATIONS. H. PLACE RIP RAP IN FRONT OF WALL BOCKS AFTER BOTTOM BLOCKS ARE IN PLACE. I. INSTALL NEW 15" CPP PIPE AND AFTER CONSTRUCTION OF THE 3RD ROW OF BLOCKS FORM AND CAST CONCRETE COLLAR AROUND PIPE. J. AFTER WALL IS CONSTRUCTED, INSTALL PERMANENT EROSION CONTROL MEASURES INCLUDING RIP RAP ABOVE TOP OF WALL AS SHOWN ON PLANS. 9. MAINTAIN ALL EROSION CONTROL MEASURES AS NEEDED. 10. CONTRACTOR SHALL INSPECT ALL DEVICES DAILY AND AFTER EVERY RAIN AND SHALL MAINTAIN THE DEVICES ACCORDING TO THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. 11. AFTER DISTURBED AREAS ARE STABILIZED THE CONTRACTOR SHALL REMOVE THE TEMPORARY DEVICES AND PROPERLY DISPOSE OF THE TRAPPED SEDIMENT. CONTRACTOR SHALL INSTALL FINAL DIVERSIONS WITH APPROPRIATE LININGS AS SPECIFIED ON PLANS. CONTRACTOR SHALL STABILIZE THE AREAS DISTURBED DURING THE REMOVAL OPERATION BY PLACING PERMANENT VEGETATION AND/OR RECP OR RIPRAP LININGS IN ALL DISTURBED AREAS TO ESTABLISH FINAL (POST -CONSTRUCTION) STABILIZATION. 12. CONTRACTOR SHALL INSPECT ALL DEVICES DAILY AND AFTER EVERY RAIN AND SHALL MAINTAIN THE DEVICES ACCORDING TO THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. THE FINANCIALLY RESPONSIBLE PARTY OF THE ISSUED EROSION CONTROL PERMIT SHALL PERFORM OR DELEGATE AN AGENT TO PERFORM AN INSPECTION OF THE AREA COVERED BY THE PLAN AFTER EACH PHASE OF THE PLAN HAS BEEN COMPLETED AND AFTER ESTABLISHMENT OF TEMPORARY GROUND COVER IN ACCORDANCE WITH G.S. 113A-57(2). THE PERSON WHO PERFORMS THE INSPECTION SHALL MAINTAIN AND MAKE AVAILABLE A RECORD OF THE INSPECTION AT THE SITE OF THE LAND -DISTURBING ACTIVITY. THE RECORD SHALL SET OUT ANY SIGNIFICANT DEVIATION FROM THE APPROVED EROSION CONTROL PLAN, IDENTIFY ANY MEASURES THAT MAY BE REQUIRED TO CORRECT THE DEVIATION, AND DOCUMENT THE COMPLETION OF THOSE MEASURES. THE RECORD SHALL BE MAINTAINED UNTIL PERMANENT GROUND COVER HAS BEEN ESTABLISHED AS REQUIRED BY THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN. THE INSPECTIONS REQUIRED BY THIS SUBSECTION SHALL BE IN ADDITION TO INSPECTIONS REQUIRED BY G.S. 113A-61.1. EXISTING SITE LEGEND PROPOSED EXISTING UTILITIES LEGEND PROPOSED TEMPORARY EROSION CONTROL LEGEND CURB Et GUTTER COMMUNICATIONS LIMITS OF CONSTRUCTION PERMANENT SS LOC FENCE OVERHEAD CABLE LINE UNDERGROUND CABLE LINE TELEPHONE LINE FIBER OPTIC/TELEPHONE LINE NATURAL GAS SEDIMENT CURB Et GUTTER CATCHING CURB (Et GUTTER) PAVEMENTS OHC SF TU[-� DIVERSION UGC DITCH/SWALE TEMPORARY CONSTRUCTION ENTRANCE INLET PROTECTION _ .. _ .. _ .. _ . T F0 ; :,NI 1 ' %••. :V ' . • �. •- ' G PAVEMENT SAWCUT LINE ASPHALT PAVEMENT NEW CONCRETE PAVEMENT SITE IMPROVEMENTS NATURAL GAS MAIN NATURAL GAS METER POWER/ELECTRIC :169-2 © APPX. BLDG. CB CEtG CONC DB DIP E EA. EL., ELEV. ELEC. EX., EXIST. FES FF FT. HC HYD. INV. L.F., LF MAX. MH MIN. MISC. N N/A NO. APPROXIMATELY BUILDING CATCH CURB CONCRETE DEED DUCTILE EAST, EACH ELEVATION ELECTRIC EXISTING FLARED FINISHED FOOT, HANDICAP HYDRANT INVERT LINEAR MAXIMUM MANHOLE MINIMUM MISCELLANEOUS NORTH, NOT NUMBER TABLE OF STANDARD ABBREVIATIONS = BASIN Et GUTTER BOOK IRON PIPE EASTING END SECTION FLOOR ELEVATION FEET FEET NORTHING APPLICABLE P.G. PAGE P.P POWER POLE R, RAD. RADIUS RCP REINFORCED CONCRETE PIPE REQ'D. REQUIRED R/W RIGHT-OF-WAY SD STORM DRAIN SF SILT FENCE SQ. FT., SF SQUARE FEET SS SANITARY SEWER STA. STATION STD. STANDARD SW SIDEWALK TBC TOP BACK OF CURB TEL. TELEPHONE TRANS. TRANSITION TYP. TYPICAL W/ WITH WV WATER VALVE OVERHEAD ELECTRIC LINE UNDERGROUND ELECTRIC LINE UNKNOWN ELECTIC LINE POWER POLE AREA LIGHT/LUMINAIRE SANITARY SEWER r " : s . v " : s . v " : s - v - OHE UGE UNKE PP a PIPE MANHOLE CLEANOUT STORM DRAINAGE BUILDING/STRUCTURE SIGNS TOPOGRAPHY/GRADING SS COo O CO0 - F 291 STORM PIPE CATCH BASIN, DROP INLET, OPEN -THROAT INLET STORM MANHOLE STORM OUTLET/ENDWALL WATER II 0 -291 SD 0 © SD © GROUND/GRADE CONTOUR (MINOR) GROUND/GRADE CONTOUR (MAJOR) SPOT ELEVATION VEGETATION CB ® ® ni - '0 �300.55' 291 296.9 �\ 8- WATER MAIN FIRE HYDRANT ASSM. VALVE WATER MANHOLE WATER METER w -(>01- O 0 7.;C o W til O TREELINE/WOODSLINE STAND ALONE TREE OR BUSH SOD at SEEDING SCHEDULE: REVEGETATION OF DISTURBED AREAS WILL BE CENTIPEDE SOD, AND AFTER ESTABLISHMENT OF SOD, TROUBLE AREAS REQUIRING REPAIR SHALL BE REPAIRED WITH NEW SOD AS REQUIRED, AND COMPLEMENTED BY OVERSEEDING IN ACCORDANCE WITH SEEDING SPECIFICATIONS BY CITY OF FAYETTEVILLE. TEMPORARY SEEDING, AS REQUIRED, SHALL BE IN ACCORDANCE WITH CITY OF FAYETTEVILLE DETAIL EC-8; SEE DETAIL SHEET DT-01. SEEDBED PREPARATION 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. 2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4. APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPER PHOSPHATE UNIFORMLY AND MIX WITH SOIL (SEE BELOW*). 5. CONTINUE TILLAGE UNTIL A WELL -PULVERIZED, FIRM REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. 6. THE LIME AND FERTILIZER WILL BE WORKED INTO THE TOP 2 TO 4 INCHES OF SOIL PRIOR TO SEEDING. 7. SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACK AFTER SEEDING. 8. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 9. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. IF STAND SHOULD BE OVER 60% DAMAGED, REESTABLISH FOLLOWING ORIGINAL LIME, FERTILIZER AND SEEDING RATES. 10. CONSULT STATE INSPECTOR ON MAINTENANCE TREATMENT AND FERTILIZATION AFTER PERMANENT COVER IS ESTABLISHED. *APPLY: AGRICULTURAL LIMESTONE - 70 Pounds/1000 Square Feet or 1.5 Tons/ACRE FERTILIZER - 850 lbs/ACRE or 20 lbs/1000 Square Feet-10-20-20 SUPER PHOSPHATE - 500 lbs/ACRE - 20% ANALYSIS MULCH - 4000 lbs/ACRE - SMALL GRAIN STRAW ANCHOR - ASPHALT EMULSION AS REQUIRED. GENERAL NOTES 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF FAYETTEVILLE, NC AND THE NORTH CAROLINA DEPARTMENT OF TRANSPORATION UNLESS OTHERWISE NOTED. 2. UNSUITABLE MATERIALS SHALL NOT BE USED AS FILL AND SHALL BE DISPOSED OF OUTSIDE THE PROJECT LIMITS AT THE CONTRACTOR'S EXPENSE. THE CONTRACTOR IS RESPONSIBLE FOR PERMITTING AND FEES FOR DISPOSAL. DRAINAGE DEWATERING: THE CONTRACTOR SHALL AT ALL TIMES PROVIDE AND MAINTAIN AMPLE MEANS AND EQUIPMENT WITH WHICH TO REMOVE AND PROPERLY DISPOSE OF ANY AND ALL WATER ENTERING THE EXCAVATION OR OTHER PARTS OF THE WORK AND KEEP ALL EXCAVATIONS DRY UNTIL SUCH TIME AS PIPE LAYING AND GRADING IS COMPLETED. NO WATER SHALL BE ALLOWED TO RISE AROUND THE PIPE IN UNBACKFILLED TRENCHES NOR SHALL IT BE ALLOWED TO RISE OVER MASONRY UNTIL THE CONCRETE OR MORTAR HAS SET (MINIMUM 24 HOURS). ALL WATER PUMPED OR DRAINED FROM THE WORK SHALL BE DISPOSED OF IN SUCH A MANNER AS TO PREVENT SILTATION AND EROSION TO ADJACENT PROPERTY OR OTHER CONSTRUCTION. UTILITIES 1. ALL PIPE BEDDING SHALL BE CLASS "C" UNLESS OTHERWISE DIRECTED BY THE ENGINEER. 2. ALL STORM DRAINAGE PIPES SHALL BE RCP CLASS III UNLESS OTHERWISE NOTED ON THE PLANS. 3. THE ENGINEER AND THE CONTRACTOR SHALL INSPECT ALL EXISTING PIPES USED IN THE FINAL DRAINAGE SYSTEM AND AGREE ON THE CONDITION OF THE PIPES PRIOR TO CONSTRUCTION. IF DAMAGE OCCURS TO THESE PIPES DURING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF THE PIPE(S). 4. THE CONTRACTOR SHALL CONTACT THE LOCATOR AT 811 OR 1-800-632-4949 BEFORE COMMENCING ANY WORK. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES WHETHER INDICATED ON THE DRAWINGS OR NOT. THE CONTRACTOR WILL ASSURE THE PRESENCE ONSITE OF A REPRESENTATIVE OF THE GAS COMPANY WHEN WORKING IN THE VICINITY OF ANY GAS MAINS. w CPI 1- w w 0 (.11 Li z Z Z w o in J o V a>a.= Zw oIw� w u- < 0 Nr L) w a Z REVISIONS: x N z N �L W O14_z ST. JOHN'S EPISCOPAL CHURCH GENERAL NOTES Et LEGEND G-02 r Z:\PROJECTSIFAY110121DESIGNIDRAWINGSIProject\BEAVER LAW & ST. JOHN1b-Sheets\FA Y1012-LAW-G03.dgn NOTES: 1. ACCESS TO SITE; REPAIR DAMAGE TO ASPHALT UPON COMPLETION OF CONSTRUCTION. 2. EXISTING DROP INLET AND PIPE TO CREEK. SEE DRAWINGS FOR INSTALLATION OF CURB INLET ALONG NEW CURB AND NEW PIPE TO CREEK. 3. ACCESS FOR RAMP DOWN TO CREEK. 4. ACCESS AREA FOR CRANE AND STORAGE OF REDI-ROCK. 5. EXISTING ELECTRIC BOX AND UNDERGROUND ELECTRIC LINE TO LIGHT POLE. AVOID DAMAGE TO THESE FACILITIES DURING CONSTRUCTION OR REMOVE AND REPLACE UPON COMPLETION. 6. TEMPORARY CREEK DIVERSION. 7. INSTALL FENCING OR TEMPORARILY RELOCATE JERSEY BARRIERS TO LIMIT ACCESS TO CONSTRUCTION SITE. 8. TEMPORARY CONSTRUCTION ENTRANCE AT TOP OF RAMP. 9. SEDIMENT FENCE, AS REQUIRED. DO NOT PLACE IN STREAM. 20 GRAPHIC SCALE 0 10 20 40 AS SHOWN ( IN FEET ) 011d REVISIONS: 1- c M N X O N N N Co in -<�a 0 zw NI V cn w 1- wow af= oav) F► ST. JOHN'S EPISCOPAL CHURCH SITE ACCESS AND CONSTRUCTION NOTES G-03 Z:\PROJECTSIFAY110121DESIGNIDRAWINGSIProject\BEAVER LAW & ST. JOHN1b-Sheets\FA Y1012-CHURCH-VX01.dgn 0 1:co ASPHALT PARKING �a- H&V ONTR JK N: 47 Ej 2, 03 ELEVANTI / z/ // // z / —�= -9636, F-I.js/ T Oo o \� 0 oc)s 4c,L i r 0 H&V JK AG N: 474,930 E: 2, 037, 0.1.9 ELEVATION: 81.97 oco co 0 cJ co ract _ (09 cps 00 ti TE: 77.90' 77.84' co \ � co rk Z9 OD EDGE OF "Z 1NATER ti 0t.coc'' o\ o w w 23' co cc cG' �/ ,W;71. 777/ /7. 77 Cb Cv� ASPHALT \ PARKING 44: )417" 00 _ck NNNN NNN H&V CONT JK MAG NAIL # N:475,023.60\ E:2,036, 91.28\ ELEVATION: co c7 co 0 0 c gfie w(o) z\,\ \As (m(cs\ <0))))))34/ 7/0i66)1 (°\/\% �N� \\\\\ N t/ , N 1:11 \t \3\ i ti W c'f NOTE: EXISTING CONDITIONS COMPILED FROM A COMBINATION OF GIS AND AERIAL PHOTOGRAPHY, AND PREVIOUS TOPOGRAPHIC SURVEYS BY OTHERS IN ADDITION TO A LIMITED TOPOGRAPHIC SURVEY PERFORMED BY JOYNER KEENY, PLLC IN SEPTEMBER 2020. \\N"////_/:)(147/(11111/11/1111/11/11/1-/N/1014/1/1// 4/// T.2) ,\ Nc4\\ \\\\\\\\\jn g-p„,h \\\10\in /W\\0\\\I\ 10 GRAPHIC SCALE 0 5 10 20 Liu cc ceJ >- cr u_ sct LI 0 rn oo tN LJ- Lel ST. JOHN'S EPISCOPAL CHURCH EXISTING CONDITIONS :FAYETTEVILLE STORMWATER N11111111rAllpir 0 1 ss I g �_ .: of W / gN FLOW OF C• tb•LYN:»: et r i i i E, r GeoEngineers 4:1 127 WEST CHATHAM STREET CARY, NC 27511 PHONE: 801.307.0217 r ° G may!c !FW ' GRAVEL / © / % / i`O c.) r / to 0 tO .: , /. ..f\---/ 1 Ir • y ■ B-3 8.4 C....) � D �� W K I I I I I I I I I I NOT FOR CONSTRUCTION o ,y Jy 4 83 `\triti RATE:8.5 ` N:77.90 OUT:77.: o \ V: 0 EDGE OF \ WATER O • a .o ` l� DATE: 04/21/2021 PROJECT NO.: FAY1006 SHEET SIZE: ANSI D - 22x34 STATUS: PRELIMINARY DESIGN NOT RELEASED FOR CONSTRUCTION CITY OF FAYETTEVILLE ST JOHN CHURCH DSR NO. 37-08-18-5038-501 STREAM BANK STABILIZATION/ WALL DESIGN DRAWINGS EXISTING SITE PLAN Fi B-2 • ► ASPHALT /' SAl PARKING FOA '♦ � • JERSEY B-2 BARRIER GEND rr WALL B-2 BLANgLEocaion from I co - , GeoTechnologies, Inc., 2017 B-1 4- Boring Location from o SHEET VX-02 S&ME Inc., 2000 GRAPHIC SCALE IN FEET Z:\PROJECTSIFAY110121DESIGNIDRAWINGSIProject\BEAVER LAW & ST. JOHN1b-Sheets\FA Y1012-CHURCH-CSG-01.dgn ASPHALT PARKING �a- H&V 0 JK N: 47 Ej 2, 03 ELEV'AI _:-_, _ -�= _____� 78.6±FG 79.02TC 79.03±FG NTR N: 79.00' V 79.59FG 80.01 TC 78.35±FG oc)s 4c,L H&V •NTRO JK AG ' I #12 N: 474,930.•.3 E: 2, 037, 0.1.9 ELEVATI P : 81.97'' SAWCUT EXIST. PAVEMEN 80.39FG 80.81 TC� ii 777 79 81.9±FG 81.58FG . 82.00TC 79.83±FG ADJUST GRATE 82.8±FG ---6) co 0 ✓ cb �Z EDGE OF "Z c WATER ti �� � ti -(0 \ -� 0• cv cL v c ov co \ 69 f\>f% \ \ \ u)/ ./\/ w co CH BASIN TL DR-3 COF S GRATE=8 HOOD=82.82 TI TO EXIST. 15" ST,QRM PIPE 83.7±FG 84.44FG \—/—c) CO A ASPHALT \ PARKING qsp: s� :„4I", SAWCUT EXIST. H&V CON T PAVEMENT JK MAG NAIL\ # N:475,023.60\ E: 2,036 91.28\ ELEVATION: 85.1±FG ..85.28TC .20FG , . 85.5±FG 20FG cp :. \\\ `c)\ " woinfm-/-- \b7i ,\ jp,64(;) \ F\\\\,„,\ \AI \\ • \ \\6,\ \\Op\\\\\1\\ \\ .0/14»84/ REMOVE AND REPLACE EXISTING ASPHALT PAVEMENT APPROXIMATE LIMIT OF TEMPORARY EXCAVATION APPROXIMATE LIMIT OF TOP OF RIPRAP 10 GRAPHIC SCALE 0 5 10 20 AS SHOWN ( IN FEET ) z w Q [7 z 1- z z 11. w 0 J LiJ Lin w0_ W 0 ,b L z zz N Z O Q_ _ > rn J zw oIw� 0 NLi_ dZ ST. JOHN'S EPISCOPAL CHURCH SITE AND GRADING PLAN CSG-01 X 7 A B-1 PLAN LEGEND B-2 -- Boring Location from GeoTechnologies, Inc B-1 4- Boring Location from S&ME Inc., 2000 2017 PLACE CLASS 2 RIPRAP ON BACKSLOPE (TBD) END OF WALL _ PLACE CLASS 2 RIPRAP AT 1.5H:1V IN FILL AREA 7 15-IN CPP JERSEY BARRIER WALL B-3 ASSUMED CURB LOCATION B-2 CSW-03 PAVEMENT TO BE REPAIRED TO MATCH EXISTING 8z EDGE OF FILL 19' MIN. DISTANCE FROM TOP OF 2:1 SLOPE TO CURB 0L�— 0+6 R 69'-10" EDGE OF WATER 09 �(AT TIME OFSURVEY) SITE PLAN - PROPOSED CONDITIONS 0 i0 20 GRAPHIC SCALE IN FEET APPROX. LIMIT OF TEMPORARY EXCAVATION W_ A EDGE OF PAVEMENT -17 B-4 BACK EXTENT OF WALL END OF WALL PROPOSED ALIGNMENT AND BOTTOM FRONT FACE OF WALL STONE ALTER REVISIONS: z 0 0 U H O ~ Z z Z 0 U PROPOSED SITE PLAN SHEET CSW-01 J 85 80 75 w 70 O w 65 w 60 55 50 _ CSWW--03 CSW---04 90° CORNER CSWW--07 _ P11 P 2 P13 — I R-41T I R-41T I R-41T R-I1T I R-41T I R-41T I16-4IHF R-41T R-00rl R-41T I R-41T I R-41T I R-41T I R-41T I R-41T I R-41T I R-41T I R-41T I R-41T I R-41T I R-41T I R-41T I R-41T R-41T I R-41T I R-41T I R-41T F-CT = I R-41T I R-41M I R-41M 1B-41M I 1B-41M I R-41M I R-41M I R-41M H-41M R-41M R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I 1B-4M R-41M R-41M R-41M R-41M R-41M I R- 1M I R-41M I R-41M I R-41M I R-41 F-CM — I R-41T R-41M R-41M R-41M R-41M R-41M 1B-41M I 1B-41M I 1B-41M Iz-4i Hm R-41M R0HMI R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R41M R41M I R41M I R41M I R41M F-CM — I R-41T I R-41M I R-41M I R-41M I R-41M I R-41M R-41M I R-41M I R-41M I R-41M I R-41M R-41M R-41M R-41M R-41M R-41M R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M R-41M R-41M R- 1M R-41M R-41M R-41M I R-4116111F-C" — R-41T R41M I R-4 M R-4 M R-4 M R-4 M R-41M R-41M R-41M 1B-0M I 1B-0M I R-41M R-4i Hm R41M R-4lHm R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M R-41M I R-41M I R-41M I R-41M I F-CM H-411 R-41M R-41M R-41M I R-41M I R-41M I R-41M I R-41M I R-41M R-41M I R-41M I R-41M I R-41M I R-41M R-41M R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41.F-CM IR-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I 1B-1M I R-41M I R-41M I R-41M L R-41M b-41u" 16-4T10 H4lHrv� R41M I R1"M I R41M I R41M I R-41M I R-41M I R-4161 I R-41M R-41M R-41M R-41M R-41M R-41M R-41M R-41M R-41M R-41M R-41M F-CM ' F-CM R-41M I R-41M I R41M I ^,_41M I, R-0^,".1 I R-41MI 41N'i I H-B1M I R41M I R41M R41M I R41M I R41M I R-41M I R-41M •I • R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M R-41M R-41M R-41M R-41M R-41M R-41M R-41M R-41M R-41 F-CM . F-CM R- 1M I R-41M R-41M R-41M R-44 R-41M R-41M R-41M R-41M I R-41M I R-41M I R-41M R-41M I R-41M I R-41M IR-4,Hm R4lHMI R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M I R-41M R-41M I R-41M I R-F-C! ' F-CM R 1M I R-60M I R-60M I R-60M I R-60M I R-60M I R-60M I P I R-60M I R-60M R-60M I R-60M I R-60M I R-60M I R-60M R-.I R-60M I R-60M R R-60M I R-� M I R-� M I R-i M I R-i M I R-i M I R-� M I R-� M 16- M 1 R-� M R-60M H-60M I R-60M R-60M H41 F-CM . F-CM R-M I - - - - R60M R60M R60M R60 - A R-60M R-60M R-60M R-60M R60M R-60M R-60M R-60M R-60M R-60M R-60M R-60M R-60M R-60M R-60M R-60M R-60M R-60M R-60M R-60M R-60M R-60M R-60M R-60M R- OM R-60M I R-60M R-60M R-60M I F-CM ' F-CB R-60B R-60B I R-60B I R-60B1 P I R-60B I R-60B R-60B R-60B R-60B R-60B R-60B R-60B I R-60B I R-60B R-68: R-60B R-60B R-60B R-60B R-60B R-60B R-60B I R-60B I R-60B I R-60B I R-60B I R-60B R-60B R-60B R-60B R-60B R-60B R-60B I H-41B F-CB 6 — 4 4 15 INCH BLOCK WITH 4 4 4" DRAIN —EXISTING SURFACE 4" DRAIN — Csw-06 CSW-06 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 4" DRAIN CSW-08 CAST -IN -PLACE COLLAR. Csw-06 4" DRAIN CSW-06 0+00 0+05 PROFILE LEGEND: BLOCK SERIES (RETAINING, FREESTANDING, ACCESSORY) BLOCK SIZE (28,41, & 60) R-41 M 0+10 BLOCK TYPE (BOTTOM, MIDDLE, TOP) 0+15 0+20 0+25 0+30 0+35 ELEVATION (FEET) 0+40 90 85 80 75 70 65 60 55 0+45 0+50 0+55 0+60 0+65 0+70 0+75 STATIONING (FEET) 0+80 PROPOSED WALL- ELEVATION 0 6 12 GRAPHIC SCALE IN FEET 0+85 0+90 0+95 SIDE WALL WITH ZERO SETBACK EXISTING SURFACE / / I1v 2H F-CM F-C R-41M F-CM F-CM R-41M F-CM F-CM R-41M F-CM FF R-41M F-CM F-CMI R-41M F-CB R-41HM (TYP.) — .81 R 41HB PROPOSED SIDE WALL -STATION 1+46 0 4 8 1+00 90 85 80 75 70 65 60 55 ELEVATION (FEET) 1+05 1+10 1+15 1+20 1+25 1+30 1+35 85 80 75 70 65 60 55 50 11-441 ELEVATION (FEET) REVISIONS: ti PROPOSED WALL ELEVATION GRAPHIC SCALE IN FEET SHEET CSW-02 • 90 - 85- r EXISTING CURB - -1-1 I`TIl-I Ii-1 17—i i r-r� 80- 75- 65- 60- 55- 50 EXISTING JERSEY WALL I — EXISTING 15" CPP %ATI7L:$:::: WO111 :gill l 2H 84 FIELD CUT • !.�'i � •� ::::Lo_iEXISTING CPP�a��� >�.�_/.`,��`,�/ems/�9 PROPOSED 15" CPP *.�;46) .�%�%�r ��'mm' ter TEMPORARY EXCAVATIONIre. � SLOPE TO BE DETERMINED BY A�4 •��' •��' CAST IN PLACE AT4�e 0��00��o PIPE COLLAR CONTRACTOR. (MAX 1H:1V)^�'�,'f�/'�.,"�� i� it�,49449 "..4" PERFORATED DRAIN�-�r�-��� I•i—�`� r ��� �-. 01 tom, ti ��7� '��'A.411 is PLACE CLASS 2 RIPRAP ON BACKSLOPE DRAINAGE AGGREGATE CSW-06 NON -WOVEN GEOTEXTILE FABRIC CRUSHED STONE LEVELING PAD CSW-06 EXISTING GRADE CSW-08 CSW-05 SETBACK = 9 % 1 SETBACK = 15/" N. CLASS 2 RIPRAP EMBEDMENT SECTION A SCALE: 0 3 6 CSW-02 SCALE IN FEET 90 85 80 75 70 65 60 55 50 ELEVATION (FEET) REVISIONS: z 0 0 0D o� z Z 0 0 WALL SECTION A SHEET CSW-03 • ELEVATION (FEET) 90- 85- 80- 75- 70- 65- 60- 55- 50— DRAINAGE AGGREGATE TEMPORARY EXCAVATION SLOPE TO BE DETERMINED BY CONTRACTOR. (MAX 1H:1V) 2H �1V 4" PERFORATED DRAIN CSW-06 NON -WOVEN GEOTEXTILE FABRIC CRUSHED STONE LEVELING PAD CSW-06 3'-0" PLACE CLASS 2 RIPRAP ON BACKSLOPE CSW-05 SETBACK = 9 %$" EXISTING GRADE CSW-05 SETBACK = 15/" CLASS 2 RIPRAP 3' MIN. -R1=TAT=fTf=lff�lll 111=- I —III —I I —I I-1-11 1 EMBEDMENT III-III-III=IIIIII= SECTION B SCALE: 0 3 6 CSW-02 SCALE IN FEET — 90 —85 —80 —75 —70 —65 60 —55 50 ELEVATION (FEET) loan �= �'.nfinn W IR— �I Q 12 O i�nnnn �1 11116 REVISIONS: z 0 0o U u o' 0 ~ z c z 0 U X- 0 W N C� _on m3 QCC =�zz ulliobcavi 02• QMWJ �Q WALL SECTION B SHEET CSW-04 FIVE DEGREE (5°) SETBACK (STANDARD) 15" (381 MM) 10" (254 MM) DIAMETER KNOB 13 3/" (340 MM) AVAILABLE WITH: • 28" (710 MM) BLOCKS, 41" (1030 MM) BLOCKS, AND 60" (1520 MM) BLOCKS • 28" (710 MM) PC BLOCKS (SHOWN HERE) AND 41" (1030 MM) PC BLOCKS ZERO (0°) SETBACK (SPECIALTY) 133/"(340MM) SETBACK = 1 5/" (41 MM) (5° BATTER ANGLE ON WALL) SETBACK = 0" (0 MM) (0 ° BATTER ANGLE ON WALL) 63/"(171MM) 2" (51 MM) DIAMETER KNOB 41A" (114 MM) AVAILABLE WITH: 133/" (340 MM) • 28" (710 MM) BLOCKS, 41" (1030 MM) BLOCKS, AND 60" (1520 MM) BLOCKS • 28" (710 MM) PC BLOCKS (SHOWN HERE) AND 41" (1030 MM) PC BLOCKS 9" (230 MM) SETBACK BLOCKS 4"(102MM) 0 w ct w U XH Q W � 4X"(114MM) 22%"(578MM) 13 3/" (340 MM) SETBACK = 9 %" (238 MM) (27.5° BATTER ANGLE ON WALL) 10" (254 MM) DIAMETER KNOB AVAILABLE WITH: • 41" (1030 MM) BLOCKS (SHOWN HERE) AND 60" (1520 MM) BLOCKS BLOCK -TO -BLOCK SETBACK OPTIONS SCALE: NOT TO SCALE CSW-05 MOVE BLOCKS FORWARD DURING INSTALLATION TO ENGAGE SHEAR KNOBS (TYPICAL) MOVE BLOCKS FORWARD DURING INSTALLTION TO ENGAGE SHEAR KNOBS (TYPICAL) MOVE BLOCKS FORWARD DURING INSTALLATION TO ENGAGE SHEAR KNOBS (TYPICAL) REVISIONS: 0 N C� j m 3 Q Q Ln oZrN or W J ULnZvls SHEET CSW-05 Owl* ••X.lj'1,�'Z•,a*1•c%j'1...: o o .. •o o ••;#'1, •�a•1••%#'7, ••a+l,�:t�;#'7, ••a+l,•Xa • ;,;.++.Z..�+,x.• ;. ,,��+,x.•�FOOTINe DEPTH, D rys .. ..........`'r•,.y. 'T%•T•3•T•3•T•Y`�?%•T•3-•T•r:a`�?%•T•%•T•rya`�2,3-•T•zr,a`�?%•T•%•T•r�a`�?%•T•%•T•r�Y`t tS E111���111���111���111���111���111���111���11 ���111���111���111���111���111���111���111���111���1111II 11i11111i11111i11111i11111i11111i11111i11111 11111111111111111111111111111111111111111111111111111i1111 ,111 NOTE: 1. PERFORATED WALL DRAIN SHALL EXTEND THE LENGTH OF THE WALL AND BE CAPPED WITH A 4-INCH DIAMETER SOLID END CAP AT EACH TERMINUS. D/2 OR 6" (MINIMUM) STEP FOOTING DETAIL SCALE: NOT TO SCALE PLACE SOLID 4" DRAIN PIPE THROUGH NOTCHED HOLE AND GROUT PIPE IN PLACE CSW-06 j v =1 11=1 1 11—i 11=1 I I=1 III III=IIIIIIIII=III= II-111 111=111=111=111=� CRUSHED STONE FOOTING 1 ON 1 OR FLATTER BOTTOM HALF BLOCK 12" MIN.Fpw EllEMEWEMEMEME -11111 12" MIN. IN FRONT OF BLOCK CONNECT TO PERFORATED WALL DRAIN FIELD INSTALLED WEEP HOLE SCALE NOT TO SCALE CSW-06 111=111=111=11' 4" PERFORATED DRAIN GRAVITY FLOW TO OUTLET AS SHOWN ON PLAN - CONVERT TO SOLID PIPE BEFORE OUTLETING UNDER WALL 12" MIN. IN BACK OF BLOCK ASTM NO. 57 CRUSHED STONE LEVELING PAD ASTM NO. 57 STONE TO EXTEND AT LEAST 12" BEHIND WALL MIRAFI 180N NON -WOVEN GEOTEXTILE FABRIC (OR APPROVED EQUIVALENT) OPEN -GRADED CRUSHED STONE LEVELING PAD r -3 SCALE: NOT TO SCALE CSW-06 NOTCH ±2.5"X5"(64 MM X 127 MM) HOLE IN SIDE OF A REDI-ROCK BLOCK (FIELD CUT) a) w Nano W LtA 0 ?sa REVISIONS: SHEET CSW-06 RECESS POCKET AND LIFTING INSERT MAY BE VISIBLE OPTIONS: FILL WITH TINTED MORTAR OR USE CUSTOM BLOCKS WITHOUT TOP LIFTER IF DESIRED (TYPICAL) SIDE WALL WITH ZERO SETBACK SIDE WALL WITH VERTICAL FACE FREESTANDING CORNER TOP BLOCK (TYPICAL) 0 FREESTANDING CORNER TOP BLOCK (TYPICAL) MULTIPLE ROW INSTALLATION 10" (254 MM) KNOB FULLY ENGAGED WITH THE GROOVE ON THE BLOCK ABOVE (TYPICAL) SPECIAL 9" (230 MM) SETBACK BLOCK WITH 7 1/" (190 MM) KNOBS (TYPICAL) � i10 IIUIIC� I TOP VIEW OF BOTTOM TWO ROWS 90° OUTSIDE CORNER / T SCALE: NOT TO SCALE CSW-07 FRONT FACE OF WALL WITH 9" SETBACK SPECIAL 9" (230 MM) SETBACK BLOCK WITH 7 /" (190 MM) DIAMETER KNOBS (TYPICAL) FRONT FACE OF WALL WITH 9" SETBACK a — CD w CD WO W 3�0 0 Asa CD C'3 REVISIONS: Q Lu QZ "O WU Z J= Ln W �- 2 CY a Z 0U O W N' D jQ�mWobz QQ Li- co co SHEET CSW-07 REMOVE ONLYTHE MINIMUM NUMBER OF BLOCKS REQUIRED TO FIT PIPE THROUGH WALL R-60M MEIN am. PIPE PROTRUDING THROUGH WALL (15" DIAMETER PIPE SHOWN) CONCRETE COLLAR (CAST -IN -PLACE AROUND PIPE) PIPE PROTRUDING THROUGH WALL (15" DIAMETER PIPE SHOWN) R-60M PLAN VIEW CONTROL JOINT CONCRETE COLLAR (CAST -IN -PLACE AROUND PIPE) 36" R-60M NON -WOVEN GEOTEXTILE FABRIC (AASHTO M288 SURVIVABILITY CLASS 1) 360° AROUND PIPE AND BEHIND COLLAR SECTION VIEW CONCRETE COLLAR FOR 15" PIPE DETAIL SCALE: NOT TO SCALE CSW-08 REVISIONS: SHEET CSW-08 z � Z:IPROJECTSIFAY110121DESIGNIDRAWINGSIProject\BEAVER LAW Et ST. JOHNIb-Sheets\FA Y1012-LAW-DT01.dgn 91 ,P I I 9 6" 18" I I 8 3/8„ N ,o ,S P • S PITCH 1 PER FT. M 0,N PITCH 5%8" PER FT. 24" 24" v 24" TYPICAL 24" ROLL -BACK CURB TYPICAL 24" VERTICAL CURB TYPICAL 24" SPILL -OFF CURB 4 1/4" 3" 9 1/4' 13 1/2 '?• d• ,P P 6" 24" q 6" 24" " _ % N e- PITCH 1/8" PER FT. N 0 0 1' „. PITCH 5/8" PER FT. 30" 30" 30" TYPICAL 30" ROLL CURB TYPICAL 30" VERTICAL CURB TYPICAL 30" SPILL -OFF CURB • ENGINEERING DIVISION �1 /' I I 433 HAY ST. 28301 (910) 433-1656 NOTES 1. ALL CURBS CONSTRUCTED OF 3000 PSI CONCRETE. I' http://www.fayettevillenc.gov 2. CONTRACTION JOINTS EVERY 10'; EXPANSION JOINTS EVERY 30'. 3. CURB SHALL BE DEPRESSED AT INTERSECTIONS TO PROVIDE FOR FUTURE ACCESSIBLE RAMPS. 4. TOP 6" OF SUBGRADE BENEATH THE CURB AND GUTTER SHALL 24" AND 30" CURB DETAILS BE COMPACTED TO 100% STANDARD PROCTOR DENSITY. Rev. Date: 16JAN18 Not to Scale Review Date: 01JAN19 S D -1 STD. STEP # 840.66 BACK OF CURB s 0 - N1 �' �- X io i � = Sn 8n 1 r ��� STD. STEP 2 Y = A Y ,.� `� Wir i, # 840.66 • - E• 8" " ' • - ■ D - tN tea':..- - 1 i ■ ■ i� M X END ELEVATION PLAN SECTION J-J WHERE 30" TO 36" PIPE IS USED END ELEVATION SECTION Y-Y E WHERE 42" TO 54" PIPE IS USED - -8" INNEFAIMENIII1 iMi ..--- R A ii III I II M IMMUNE M SECTION Y-Y ` j1; PLAN P. GENERAL NOTES: PLAN 1. MORTAR JOINTS 1/2" 1/8" THICK. FRAME, GRATE, & HOOD 2. 3000 P.S.I. CONCRETE TO BE USED. STD. # 840.038 3. THE POURING OF SLAB TO BE BY FORMING. FLOOR ACCOMPLISHED 4. ALL CATCH BASINS OVER 3'-6" IN DEPTH SHALL BE PROVIDED i ENGINEERING DIVISION WITH STEPS 1' -2" ON CENTERS. 5 433 HAY ST. 28301 5. USE TYPE "E", "F", & "G" GRATE UNLESS OTHERWISE INDICATED. B = (910) 433-1656 http://www.fayettevillenc.gov 6. JUMBO BRICK WILL BE PERMITTED. CONCRETE BRICK OR 4" SOLID 8" = 8- CONCRETE BLOCKS MAY BE USED IN LIEU OF CLAY BRICKS. s 7. FOR 8' -0" IN HEIGHT OR LESS USE 8" WALL OVER 8' -0" IN 1 = = STANDARD BRICK CATCH BASIN HEIGHT USE 12" WALL TO 6' -0" FROM TOP OF WALL, 8" WALL FOR THE UPPER 6' -0". ''3- 0.5' THRU 54" PIPE) ADOPTED FROM NCDOT STANDARD NO. 840.01 8. INVERTS SHALL BE SHAPED TO FORM A SMOOTH, REGULAR SURFACE, . .. PAGE 1 OF 2 SLOPED TO PREVENT SEDIMENTATION. 9. FOR VARIABLE DIMENSIONS, SEE STANDARD DETAIL DR-3.1. ._, _ SECTION X-X Rev. Date: 16JAN18 Not to Scale D IR e 3 Review Date: 01AN19 ELEVATION (FEET) 85 80 75 70 65 60 1f t1f fir1fif l t-, ti • ,! ��1" 1 1 ��t- s-/ 0006666664,..s I.LLI.L1.1.1.1.10I' irei,'i, i'i,'i, i'i,�'i i 1 �at�s.s•at s s a t 1f.�► IIII 0 .1.1.1AA 1A 1-stt t-- t t-L=L L-L L ,.I.I.I.I.1..1.1.1....... 1.1 1.1.1.l.1.1.1.1.1� P 4'I.1.1.1.1.1.I.1.1.I.. •. LIMITS OF EXCAVATION Y1 • • PROPOSED BANK STABILIZATION STRUCTURE. • ♦ • • EXISTING GROUND �•1•!�-•-4p-.-•-•.v.w4pYr•.v.,4,,•. / - s /../. * r. ►.•/.v.-►. 4..1.4►c EXISTING STREAM BANK - TEMPORARY STONE FILL TO PROVIDE EQUIPMENT BASE FOR EXCAVATION. ALL MATERIAL TO BE REMOVED POST CONSTRUCTION. GEOTEXTILE FABRIC / / / / DIVERTED STREAM FLOW TEMPORARY STREAM DIVERSION (SHEET PILE, SAND BAGS, ETC. AT CONTRACTOR'S OPTION). TEMPORARY STREAM DIVERSION DETAIL NOT TO SCALE l NOTES: 1. SUBGRADE AND BASE TO BE COMPACTED TO REQUIREMENTS OF NCDOT ROADWAY DESIGN MANUAL -LATEST EDITION. 2. BITUMINOUS MATERIAL SHALL CONFORM TO THE LATEST LOCAL D.O.T. SPECIFICATIONS. 3. ALL WORKMANSHIP SHALL CONFORM TO THE LATEST LOCAL D.O.T. STANDARDS AND PERFORMANCE SPECIFICATIONS. ASPHALT PAVEMENT SECTION NOT TO SCALE RXXXXXAAAA CXXXXXXXXXXX/ 2.0" SF-9.5A 2-c C Cc C J} 1C`C� n C�J� CCI` 6 COMPACTED SUBGRADE 6" AGGREGATE BASE COURSE SEDIMENT FENCE USE: WILL RETAIN SEDIMENT FROM SMALL DISTURBED AREAS. SEDIMENT FENCE WILL BE PLACED ALONG SLOPES AS SHOWN ON CONSTRUCTION DETAILS. REFER TO SECTION 6.62 OF THE NCDENR EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. SEDIMENT FENCE MAINTENANCE: INSPECT SEDIMENT FENCES DAILY AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. NOTES: 1. USE SEDIMENT FENCE ONLY WHEN DRAINAGE AREA DOES NOT EXCEED 1 /4-ACRE AND NEVER IN AREAS OF CONCENTRATED FLOW. 2. END OF SEDIMENT FENCE NEEDS TO BE TURNED UPHILL. 3. REMOVE SEDIMENT DEEPER THAN 12" AND REPAIR ANY UNDERMINING IMMEDIATELY. 4. PLACE WIRE FENCE 6" BELOW GRADE AND SEDIMENT FABRIC 8" DOWN AND 4" FORWARD ALONG TRENCH BOTOM. BACKFILL AND THOROUGHLY COMPACT TRENCH WITH NCDOT #57 STONE. FOR REPAIRS, REPLACE STONE TO GRADE AND COMPACT AS NEEDED. 5. CONTRACTOR SHALL BE RESPONSIBILE FOR PLACEMENT AND REMOVAL OF FENCE. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING DISTURBED AREAS TO PRE -CONSTRUCTION CONDITION. SEDIMENT FENCE NOT TO SCALE 8' MAX. STANDARD STRENGTH FABRIC WITH WIRE FENCE 6' MAX. EXTRA STRENGTH FABRIC WITHOUT WIRE FENCE I I I SEDIMENT FENCE FABRIC INSTALLED TO SECOND WIRE FROM TOP FRONT VIEW STEEL POST WIRE FENCE SEDIMENT FENCE FABRIC 8" DEPTH x 4" WIDTH BACKFILLED TRENCH EXTEND WIRE FENCE 6" BELOW GRADE MINIMUM 10 GAUGE LINE WIRES (TOP Et BOTTOM) MINIMUM 12-1/2 GAUGE INTERMEDIATE WIRES GRADE GRADE ANCHOR MATERIALS AS DIRECTED BY ENGINEER (NOTE 4) EXTEND FABRIC 8" DOWN AND 4" FORWARD ALONG TRENCH SIDE VIEW TEMPORARY CONSTRUCTION ENTRANCE USE: WILL PROVIDE A BARRIER AREA WHERE VEHICLES CAN DROP THEIR MUD AND SEDIMENT AS WELL AS HELP CONTROL EROSION FROM SURFACE RUNOFF. TO BE LOCATED AS PER THE PLANS AND CONSTRUCTED AS PER DETAIL. REFER TO SECTION 6.06 OF THE NCDENR EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. TEMPORARY CONSTRUCTION ENTRANCE MAINTENANCE: MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING WITH 2 - 3 INCH STONE. INSPECT DAILY, AND AFTER EACH RAINFALL, ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED OR TRACKED ONTO PUBLIC ROADWAYS. DESIGN CRITERIA AGGREGATE SIZE = USE 2-3 INCH WASHED STONE DIMENSION OF GRAVEL PAD THICKNESS = 6 INCHES MINIMUM WIDTH = 25 FT. MINIMUM OR FULL WIDTH AT ACCESS POINTS OF VEHICULAR ENTRANCE AND EXIT AREA, LENGTH = 50 FT. MINIMUM. LOCATION = LOCATE CONSTRUCTION ENTRANCES AND EXITS TO LIMIT SEDIMENT FROM LEAVING THE SITE AND TO PROVIDE FOR MAXIMUM UTILITY BY ALL CONSTRUCTION VEHICLES. AVOID STEEP GRADES AND ENTRANCES AT CURVES IN PUBLIC ROADS. CONTRACTOR SHALL INSTALL ADDITIONAL GRAVEL CONSTRUCTION ENTRANCES NOT INDICATED ON THE PLANS REQUIRED FOR STAGING AND/OR BORROW AREAS AND MAINTAIN AT NO ADDITIONAL EXPENSE TO THE OWNER. CONTRACTOR SHALL SUPPLEMENT AND MAINTAIN GRAVEL CONSTRUCTION ENTRANCES AT HIS EXPENSE UNTIL FINAL ACCEPTANCE. TEMPORARY CONSTRUCTION ENTRANCE NOT TO SCALE GRAVEL ENTRANCE SHALL BE 50 FEET IN LENGTH AND 25 FEET IN WIDTH WITH 20 FOOT RADIUS AT EXISTING ROADWAY FILTER FABRIC 36' MIN 4' 10' 2-3" WASHED STONE GRAVEL CONSTRUCTION ENTRANCE 6" MIN. THICKNESS 1 6" MIN. THICKNESS �\Q'��<1\P o0 •\a 2-3" COURSE , , �F�' AGGREGATE c-,� LUl 011d w 1- co ▪ co w O_ w rn O • Li z 7 w CD N un Lu c J O V a>a.= Zw CD LIJ • Luz CDoa=V N LI_CL Z REVISIONS: X N 4.7 z ST. JOHN'S EPISCOPAL CHURCH DT-01 •