Loading...
HomeMy WebLinkAboutNC0032077_authorization to construct_20090624ATA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary June 24, 2009 Mr. Charles Smithwick, District Manager Contentnea Metropolitan Sewerage District P.O. Box 477 Grifton, North Carolina 28530 SUBJECT: Authorization to Construct A to C No. 032077A01 Contentnea Metropolitan Sewerage District Contentnea MSD WWTP WWTP Improvements Project No. E-SRL-T-08-0077 Pitt County Dear Mr. Smithwick: A letter of request for an Authorization to Construct was received June 13, 2008, by the Division of Water Quality (Division), and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of modifications to the existing 2.85 MGD Wastewater Treatment Plant, with discharge of treated wastewater into Contentnea Creek in the Neuse River Basin. This authorization results in no increase in design or permitted capacity and is awarded for the construction of the following specific modifications: Improvements to the CMSD WWTP including: a new mechanically cleaned bar screen and a manually cleaned bar screen to handle a peak flow of 7.125 mgd; a new grit removal system to handle a peak flow of 7.125 mgd with one (1) 250 gpm grit pump; a new Parshall Flume with influent metering; a new influent splitter box; conversion of the effluent pump station to serve as the filter lift pump station and to handle a peak flow of 7.125 mgd; four (4) new 2,030 gpm filter feed pumps; four (4) new tertiary denitrification filtration system units with two (2) 3,040 gpm backwash pumps, two (2) new 570 gpm mudwell pumps, three (3) new 100 Hp backwash aeration blowers; a new three (3) bank UV disinfection system designed to treat a peak flow of 7.125 mgd with one bank out of service; a new post aeration system with a 10 Hp high speed aerator; and 2,020 LF of 36- inch effluent outfall discharge line, in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 FAX: 919-807-6492 \ Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity \ Affirmative Action Employer NorthCarolina Naturally Mr. Charles Smithwick June 24, 2009 Page 2 This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NC0032077 issued January 23, 2007, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0032077. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the Division. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by the Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Washington Regional Office, telephone number (252) 946-6481, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the approved plans and specifications. Mail the Certification to: Construction Grants & Loans, DWQ/DENR, 1633 Mail Service Center, Raleigh, NC 27699-1633. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of T13A:8G.0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III and IV facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of T15A:8G.0202. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times, Mr. Charles Smithwick June 24, 2009 Page 3 and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. You are reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act, and when applicable, the North Carolina Dam Safety Act. In addition, the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Prior to entering into any contract(s) for construction, the recipient must have obtained all applicable permits from the State. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. One (1) set of approved plans and specifications is being forwarded to you. If you have any questions or need additional information, please contact Seth Robertson, P.E. at telephone number (919) 715-6206. Sincerely, rC-oleen H. Sullins MM:sr cc: Charles W. Davis, P.E. - The Wooten Company, 120 N. Boylan Ave., Raleigh, NC 27603 Pitt County Health Department DWQ Washington Regional Office, Surface Water Protection Technical Assistance and Certification Unit Point Source Branch, NPDES Program Michelle McKay, E.I. SRL File