HomeMy WebLinkAbout20060987 Ver 2_Application_20070426.~~,
~, ,.
.~ .2~,,. ~' c,~
STATE of NORTH CAROLINA s'~~ra,~T~~~ ~~~1 ,`~~'~.
DEPARTMENT OF TRANSPORTATION P~~~ «,,
MICHAEL F. EASLEY LYI~T,,IPPETT
GOVERNOR SECR~ RY
April 23, 2007
Mr. David Baker, NCDOT Regulatory Project Manager ~0~
US Army Corps of Engineers U
151 Patton Avenue, Room 208
Asheville, NC 28801-5006
Subject: 404 and 401 Permit Application Revision/Modification
Action ID No. 2006-32917-345
DW roject No. 060987
SR 1836 -Pot Shoals and Camp Creek Roads -Henderson County
State Project No. 140.045131 (DWQ Minor Permit Fee $200.00)
Dear Mr. Baker:
The North Carolina Department of Transportation (NCDOT) proposes to widen,
grade, drain and pave SR 1836 in Henderson County. The original permit applications
dated June 19, 2006 included twenty-two permitted sites with pipe extensions totaling
302 linear feet. Due to a grade change at Site #10, Station 61 +70, the original length
was inadequate. NCDOT proposes to install an additional 20 linear feet of 24-inch
CMP to gain enough length to stabilize the fill slope.
I have enclosed a revised PCN application (impact table), topographical map and
cross-sectional drawing for the culvert installation (Site 10). The new culvert will remain
perched, as is the existing culvert.
Impacts to Waters of the United States
In order to construct the project in accordance with our current secondary road
standards, it will be necessary to impact waters of the United States in the Broad River
Basin. Specifically, NCDOT is requesting to add 20 linear feet of culvert in an unnamed
tributary to Green River (DWQ Class: B, Tr). Listed below is a revised summary of the
proposed impacts.
u.2
Division 14, District 1
Phone: (828)891-7911 4142 Haywood Road, Mills River, NC 28759 Fax: (828)891-5026
r
Site No.
Station Existing Condition Proposed Condition Net Impacts
Site 1 - 13+80 45' x 30" CMP 60' x 36" CMP w/gabions 15'
Site 2 -16+15 35' x 36" CMP 55' x 48" CMP w/gabions 20'
Site 3 - 21+90 30' x 42" CMP 50' x 48" CMP w/gabions and
rock buttress 20'
Site 4 - 23+90 35' x 18" CMP 55' x 30" CMP w/ gabions 20'
Site 5 - 29+52 35' x 30" CMP 55' x 36" CMP w/gabions 20'
Site 6 - 46+74 30' x 18" CMP 50' x 18" CMP 20'
Site 7 - 52+70 New Alignment -none
existing
120' x 72" CMP w/ headwalls
120'
Site 8 - 53+30 30' x 18" CMP Remove -flows to Site 7 -30'
Site 9 - 54+75 35' x 48" CMP Remove -flows to Site 7 -35'
Site 10 -
61+70 50' x 18" CMP 70' x 24" CMP 20'
Site 11 - 64+35 35'x18"CMP&
55' x 18" Terra Cotta w/ rock
headwall
80' x 36" CMP
45'
Site 12 - 68+72 40' x 18" CMP 70' x 24" CMP 30'
Site 13 - 73+04 35' x 18" CMP 50' x 18" CMP 15'
Site 14 - 79+24 50' x 18" CMP 60' x 24" CMP 10'
Site 15 - 111+42 35' x 24" CMP 50' x 36" CMP 15'
Site 16 -115+05 25' x 15" CMP 40' x 18" CMP 15'
Site 17 - 119+77 30' x 18" CMP 45' x 24" CMP 15'
Site 18 - 161+72 7' H x 15' W RC earth filled
Spandrel Arch
Remove and replace with abridge
-15'
Site 19 - 179+06 40' x 18" CMP 50' x 24" CMP 10'
Site 20 -190+35 18' x 24" Terra Cotta
w/ rock headwalls
Remove and replace with abridge
-18'
Site 21 - 202+49 (2) 50' x 84" x 66" CMP Arch (2) 50' x 87" x 63" CMP Arch 0'
Site 22 - 208+03 35' x 42" CMP 45' x 48" CMP 10'
Total Impact 322 linear feet permanent
Permits Requested
Also by copy of this letter, I am requesting authorization to proceed under
Section 401 of the Clean Water Act from the Division of Water Quality. In addition, I
am asking Mr. McHenry and Mr. Ed Ingle, Roadside Environmental Field Operations
Engineer, to comment directly to me concerning this permit request.
Your earliest consideration for this request would be greatly appreciated. If you
have any questions or need additional information, please contact Mrs. Lori Jones or
me at (828) 891-5026.
Sincerely, ~ ~~ /
i~~ ~_
Mark T. Gibbs, P.E.
District Engineer
Enclosures
cc: Mr. John Hennessy, DWQ, DENR, Raleigh (four copies)
Mr. Mike Parker, DWQ, DENR, Asheville
Mr. David McHenry, Mountain Region Coordinator, NCWRC, Waynesville
Mr. Joel Setzer, P.E., Division Engineer, NCDOT
Mr. Mark Davis, Division Environmental Officer, NCDOT
Mr. Ed Ingle, Roadside Environmental Field Operations Engineer, NCDOT
Mr. Steve Cannon,P.E., Henderson County Maintenance Engineer, NCDOT
File
Individually list all intermittent and perennial stream impacts below:
Stream Impact
Site Number
(indicate on map)
Type of Impact* Length of
Impact
(linear feet)
Stream Name** Average Width
of Stream
Before Im act Perennial or
Intermittent?
(lease specify)
Site #1 Culvert 15 UT to Green River 1 Perennial
Site #2 Culvert 20 UT to Green River 1 Perennial
Site #3 Culvert 20 UT to Green River 1 Intermittent
Site #4 Culvert 20 UT to Green River 1 Perennial
Site #5 Culvert 20 UT to Green River 1 Perennial
Site #6 Culvert 20 UT to Green River 1 Perennial
Site #7 Culvert 120 UT to Green River 4 Perennial
Site #8 Culvert Removal -30 UT to Green River 1 Perennial
Site #9 Culvert Removal -35 UT to Green River 3 Perennial
Site #10 Culvert 20 UT to Green River 1 Perennial
Site #11 Culvert 45 UT to Green River 1 Intermittent
Site #12 Culvert 30 UT to Green River 1 Perennial
Site #13 Culvert 15 UT to Green River 1 Perennial
Site #14 Culvert 10 UT to Green River 1 Perennial
Site #15 Culvert 15 UT to Camp Creek 1 Perennial
Site #16 Culvert 15 UT to Camp Creek 1 Perennial
Site #17 Culvert 15 UT to Camp Creek 1 Intermittent
Site #18 Culvert Removal -15 Camp Creek 5 Perennial
Site #19 Culvert 10 UT to Camp Creek 1 Perennial
Site #20 Culvert Removal -18 Camp Creek 5 Perennial
Site #21 Culvert 0 Camp Creek 3 Perennial
Site #22 Culvert 10 UT to Camp Creek 2 Perennial
* List each impact separately and identify temporary impacts. Impacts include, but are not limited to: culverts and associated rip-rap,
dams (separately list impacts due to both structure and flooding), relocation (include linear feet before and after, and net loss/gain),
stabilization activities (cement wall, rip-rap, crib wall, gabions, etc.), excavation, ditching/straightening, etc. If stream relocation is
proposed, plans and profiles showing the linear footprint for both the original and relocated streams must be included.
** Stream names can be found on USGS topographic maps. If a stream has no name, list as UT (unnamed tributary) to the nearest
downstream named stream into which it flows. USGS maps are available through the USGS at 1-800-358-9616, or online at
www.us~s.QOV. Several Internet sites also allow direct download and printing of USGS maps (e.g., www.topozone.a>m,
www.m~guest.com, etc.).
Cumulative impacts (linear distance in feet) to all streams on site: 322 Linear Feet
N
a
c~
0
A~
W
L
Q
~~w.
V
N
O
N
O
a
M
r
Q
Q
L
d
d
r
~1,
#a ~ f! ~ { ~ .< .. yr .~.
..~
!
~ '^~ ~±: ~' ~ ~' ~: ~ '..~ t 4
~ cy ,~
f ~
~
+~., r
~ `
. ~ j
_
v C ?_
_ ..fi~ ~..:' i s ~' '~ ~~ ~ ~
~
.
~
r~
~ ~
t
~,Y i ~~ }~ry... ~ ~~
.
(MA '(. _
'
r ~- . r
" ~ ,~ ~ 3~. ,.~ ,
~
,~ r.
~ , ~ ~ '4~4 ~ y~ ~L\ i ~ ~ ~ ~~ ~
~. ~...
~
~
~
,
f .,. _., ~ 1
t ~r _
~
~~
- ~t
~ ~'~ r
,~
~,
,
~5 ,
-~'~. dtt~~~ /"
I
~
~ ~ Y )
v'
-.
'~ l} +.
~~"~~~"" V
,y 'j.
~ ~~ • Y
'~ ~~ ~ AL' i ~~
s • a ::
t
~
~~ ~,.
~ S
\~
,~~~~ ~ ~y ~ i, ~
~ 4
~ ~ ~ ~
4 ~ III _•
~_ ~ s
?`r
\. ~ ; ~ _"
f ~ E ~~ ~ ^~Y
:I L V
~
{
r
_ ~~ ~
~ ~~
,~ ~
fi
4
-;
~~ ~ r~
~
/
~
~~~`""` ~"ti;~" ~ - ~
al q j" ~'4"' ' I
.~~ ~ `~~ it .,
t~ ~
! `„~ „~! .
~ +-~
~"+ "'~ My+ ~r
_.
n. ~ •, ~
o~
~
. j,. ,tea.
m
~
U
~
o
N y
Q
N ~
N
M W C
N 'C ~ C~
C N
Z ~
o I
N
#
~ I O
~ I
N I
~ 1
M I
I
N 1
I
~ 1
c ~ I
I U
'a c
J I '~
~ ~ I
I L N
U ~
~ I ~o
V I d ti ~
~ ~ Y o
a
O I :~ 3 ~
`
d I y a C
OZS I
I X ~
U N
X
I m
m _°
° i
a
I r o
cn a
° ~
W I ~ u
, v
rn I
I ~
~
~
R I
I N
O I
I O
Y
O
d
1
I
~
_ w
O
~
h `
V I
I
W
~
~ N
~
00 N
CO
~ E
I
> ~
f0 ~ CEO U
C
l9 N ~~, C O ~ 0 0 O
'
~«' V C
to .O 7 .-.
~
~ in
O
O
~ V c Q
n N
o
ul C ,
~ O
C to O~
.- rn
O) r N ~
C
~ ~ai~a 3 a
.'~'' ~ O d ~ ai
cn rn a x ~- cn