HomeMy WebLinkAbout20121049 Ver 1_More Info Requested_20120208Lucas, Annette
From:
Lucas, Annette
Sent:
Friday, February 08, 2013 3:25 PM
To:
Homewood, Sue
Cc:
Lucas, Annette
Subject:
12 -1049 Honda Connector Road
Attachments:
12 -1049 Honda Connector Road.docx
Sue,
Hold bullets attached. Let me know if you think they look OK.
Thanks,
A
Annette M. Lucas, PE
Environmental Engineer
NCDENR I DWQ I Wetlands and Stormwater Branch
1650 Mail Service Center, Raleigh, NC 27699 -1650 (Mail)
512 N. Salisbury St, Raleigh, NC 27604 1 9th Floor (Location & Parcels)
Phone: (919) 807 -6381 1 Fax: (919) 807 -6494 1 Email: Annette. Lucas(CDncdenr.gov
Website: httn: / /t)ortal.ncdenr.org /web /wg/M/ws /401
sA Before printing this email, please consider your budget and the environment.
E -mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to
third parties.
12 -1049 Honda Connector Road
AML comments
February 8, 2013
1. Per GC 3886/3890, this project is required to provide a stormwater management plan to protect
water quality. Please see Appendix A of the General Certification, available at:
http: /Iportal.ncdenr.ore / web /wq /swp /ws /401 /certsandpermits /ecs, and submit a stormwater
management plan that is in accordance with these requirements.
Please provide full -sized plan sheet(s) showing the entire site with its current and proposed
future built upon area. In addition, the plan sheet shall include the storm drainage system,
including every inlet, outlet and conveyance device. Please show how stormwater management
requirements have been met at every proposed outlet location.
3. Please provide a BMP Supplement Form with all required items for every proposed BMP on the
site (see http: / /portal.ncdenr.orit/web /wg /ws /su /bmp- manual). All of the built -upon area for
the site must be treated by a BMP (or BMP treatment train) that removes 85% Total Suspended
Solids. Please note that a dry detention pond does not meet this design standard.