Loading...
HomeMy WebLinkAboutSW6210503_Design Calculations (Drawdown)_202105181651 Townsend Estates Drawdown Time Temporary storage volume = Orifice diameter = Area of orifice = Orifice Coefficient (Cd) _ Orifice elevation -- Water elevation --- Driving head (H) _ Discharge (Q) _ Drawdown time = 29491 cf 2 in 1 0.0218 sf 0.60 205.50 ft 207.50 ft 0.67 ft 0.0858 cfs 343793 s 95.5 hr 4_0 days 1651 Drawdown.xls Printed 5/18/2021