HomeMy WebLinkAboutNCG150010_Inspection_20210518ROY COOPER Governor DIONNE DELLI-GATTI Secretary BRJAN WRENN Director NORTH CAROLINA Environmental Quality May 18, 2021 Charlotte -Monroe Executive Airport Attention: Peter Cevallos, Airport Manager 3800 Paul J. Helms Drive Monroe, North Carolina 28110 Subject: Compliance Evaluation Inspection Charlotte -Monroe Executive Airport NPDES Certificate of Coverage — NCG150010 Union County, North Carolina Dear Mr. Cevallos, Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection we conducted at the Charlotte -Monroe Airport on May 12, 2021. Please note that in the stormwater inspection report summary we ask that you apply for representative outfall status. The report should be self-explanatory; however, should you have any questions, please do not hesitate to contact me at (704) 663-1699 or by E-mail at jatnes.moore@ncdenr.gov. Sincerely, mes Moore Assistant Regional Engineer Enclosure c: Laserfiche DNorth Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources MQ Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 NearN c,wouw. MpartMit of EnMor-lital Quality 704.663.1699 Compliance Inspection Report Permit: NCG150010 Effective: 09/01/17 Expiration: 08/31/22 Owner: Charlotte -Monroe Executive Airport SOC: Effective: Expiration: Facility: Charlotte -Monroe Executive Airport County: Union 3900 Paul J Helms Dr Region: Mooresville Monroe NC 28110 Contact Person: Peter Cevallos Title: Phone: 704-282-4730 Directions to Facility: System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 05/12/2021 Entry Time 03:15PM Exit Time: 03A5PM Primary Inspector: Lily C Kay Phone: 704-663-1699 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Air Transportation Stormwater Discharge COC Facility Status: 0 Compliant Not Compliant Question Areas: Storm Water (See attachment summary) Pagel of 3 Permit: NCG150010 Owner - Facility: Charlotte -Monroe Executive Airport Inspection Date: 05/12/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: The Stormwater Pollution Prevention Plan (SWPPP) and related documentation was complete including employee training records and monitoring records. The facility appeared well operated and maintained. The permittee needs to apply for representative outfall status. If you have questions, contact me at Lily. Kay@ncdenr.gov or by phone at (704) 235-2137. Page 2 of 3 Permit: NCG150010 Owner - Facility: Charlotte -Monroe Executive Airport Inspection Date: 05/12/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 0 ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? E ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? 0 ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? N ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? 0 ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? 0 ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? 0 ❑ ❑ ❑ # Does the Plan include a BMP summary? 0 ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? 0 ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? 0 ❑ ❑ ❑ # Does the facility provide and document Employee Training? 0 ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? 0 ❑ ❑ ❑ # Is the Plan reviewed and updated annually? 0 ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? 0 ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? 0 ❑ ❑ ❑ Comment: The Stormwater Pollution Prevention Plan (SWPPP) and related documentation was complete including employee training records and monitoring records. The facility appeared well operated and maintained. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? N ❑ ❑ ❑ Comment: Qualitative monitoring records were available and complete. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ ❑ 0 ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ 0 ❑ Comment: Analytical monitorinq is not required because there is no vehicle maintenance on site. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ # Were all outfalls observed during the inspection? N ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ N ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ 0 ❑ Comment: The facility has six outfalls, but only samples the three that are representative of the industrial activity. The permittee needs to applay for respresentative outfall status with the department. No issues were observed with the three outfalls observed. Page 3 of 3