Loading...
HomeMy WebLinkAboutWQ0041390_Regional Office Historical File Pre 2018ton of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: All items must be completed or the a tion to be completed byUWR) will be returned APPLICANT INFORMATION: I. Applicant's name: Hall Builders, Inc (company, municipality, HO.A, utility, etc.) 2, Applicant type: El Individual Corporation [] General Partnership El Privately -Owned Public Utility Federal E.) State/County LI Municipal Ei Other 3, Signature authority's name: Tommy Hall per 15A ( 0 I 0602) Title: Owner Applicant's mailing address: 315 Tommy James Court City: Kings Mountain State: NC Zip: 28086- 5, Applicant's contact information: Phone number: (704) 730-9696 Email Address: hallbuildersinc@bellsouth.net II. PROJECT INFORMATION: I. Project name: Hall Crossing Phase 5 2. Application/Project. status: Proposed (New Permit) El Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Cleveland 4, Approximate Coordinates (Decimal Degrees): Latitude: 35 2327 Longitude: -81.3618' 5. Parcel ID (if applicable): 61868 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I. Professional Engineer: Johnny Denton PE, PLS Finn: Diamond Engineering, PLLC Mailing address: 440 Old NC 277 Loop Road City: Dallas State: NC Zip: 28034- Phone number: (704) 922-0024 Email Address: johnnydiamond @hormail.com License Number: 23530 IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: Facility Name: City ofKings Mountain Permit Number: NC0020737 Owner Name: City of Kings Mountain V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I. Permit Number(s). WQ, Downstream (Receiving) Sewer Size: inch System Wide Colk.rtiorl System Permit NtimtNE6Ifif qujicable),: WQCS Owner Name(s): FORM: FTA 04-16 Page 1 of 5 Yi. GENERAL REQUIREMENTS if th.e Applicant i.s a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached.? 0 Yes 0No N/A 2, Ifthe Applicant is a Developer of lots to be sold, has a 11.?sysivq:a5..,,clacatittiqrtill1),aartilt,..:Jlt been attached? 0 Yes 4No 0N/A 3. Ifthe Applicant is a flpnglPriipertyOwaicrs' Association; has an Qpjaraticaltat A QyaktrnentIFOR M: II0A) been attached? Ej Yes EDNo N/A 4 Origin of wastewater: (check all that apply): Residential Owned R.esidential Leased 0 School / preschool / day care 0 Food and drink facilities 0 Businesses / offices / factories 0 Retail (stores, centers, malls) Retail with food preparationiservice 0 Medical / dental veterinary facilities 0 Church Nursing Home Ej Car Wash 0 Hotel and/or Motels 0 Swimming Pool /Clubhouse 0 Swimming Pool/Filter Backwash 0 Other (Explain in Attachment) 5, Nature of wastewater 100 % .Domestic/Commercial % Commercial % Industrial (SeS...,15A„.,KAC,._.01E,„0.i s there a Pretreatment Program in effect? 0 Yes 6, Has a flow reduction been approved under 1.5,At - CAC 02T .0 t 1,110? 0 Yes I4 No Ifyes, provide a copyof flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see (QT.( 4 bedroom residential units 1-1.0 0 No Daily Design Flow Lb 480 gallday gal/ gal/ gall gal/ gall No. of Units Flow 7 3360 GPD Total GPD GPD GPD GPD GPD ' GPD a See .5A NCAC 0.2 MI (OW and (02) for caveats to wastewater design flow rates (i,e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined int.". 42A-4), b Per 15A NCAC 02T ,01 14(c), design flow rates for establis.hinents, not identified [in :0211011:11 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data, 8,, Wastewater generated by project: 3360 GPD (per 15A. NC AC 021 .()1. 14) Do not include. future flows or previously permitted allocations If permitted flow is zero, indicate why: Ej Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit Number 0 Rehabilitation or replacement of existing sewer with no new flow expected Other (Explain): FORM: FTA 04-16 e 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA Applicable) - 02T .0305& ewerii: 1, Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 80' 8" 277,08' DIP PVC 6" 120' DIP 6" 99645' PVC Section 11 & III of the MDC for Permitting ofGravity Sewers contains information related to design criteria • Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the NIDC VIII. PUMP STATION DESIGN CRITERIA (if Applicable) — 02T ,0305 & MDC (Pump Stations/Force Mains:I: COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I, Pump station number or name: -)..Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3, Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): 6. Power reliability in accordance with 1 ,NC,AC 02.1- ,O;i05(1)1 ): 0 Standby power source or pump with automatic activation and telemetry. - I.5A NCAC 02T ,0305(h)(1)(B), ▪ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ..-00 Must be permanent to facility Or if the pump station has an average daily .flow less than 15,000 gallons per day: 0 Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or fl Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ▪ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ▪ if the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 X. SETBACKS & SEPARATIONS (02,B .02,00 & 15A NCAC 02T .0305(1)); Does the project comply with all separations found in 15,A NCAC 02T „OAT) > 15A NCAC 02T.0305(f) contains minimumseparations that shall be provided for sewer Setback Parameter* system Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains vertical -water over sewer includingin benched trenches) 18 inches Water mains horizontal Reclaimed water lines vertical - reclaimed over sewer) Reclaimed water lines horizontal - reclaimed over sewer) 10 feet 8 inches 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class 1 or Class 11 im ounded reservoirs used as a source of drinking water "Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item 1X.2)._ **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches An buildingfoundation An basement 00 feet 50 feet 10 feet feet: To slo e of embankment or cuts of 2 feet or more vertical hei ht Drai s and interceptor drains An swimm in u ools Final earth ade (vertica 10 fee zi ee 10 feet 36 inches • NC,AC 02:E0305(A), contains alternatives where separations in 021 ,0305(1) cannot be achieved. )0' **Stream classifications can be identified using the Division's 'NC Surface WiAter COassilications welyita,c, iv if noncompliance with 0-,,j,p391(11,00:2,1„, see Section X of this application No Does the project comply with separation requirements for wetlands? (50 feet of separation) Yes LI No EI NIA See the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction • As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B ,O200? Yes • This would include Trout Buffered Streams per 15A NCAC 211,0202 4. Does the project require coverage'authorization wider a 404 Nationwide or individual permits or 401 Water Quality Certifications? • Information can be obtained from the 401 & BUffer Pertnittiag,pranch No El N/ A Yes EJNo 5.. Does project comply with 15.J.\NCAL011:01.0.5AcAti) (additional pertnitslcertifications)? Yes Ej No Per 1.5A NC,AC 021,0 1,05(00), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCArif 021-.040;2,, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned .parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. E] Yes No NtA. • If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the perm ittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply writh 15.A. NCACO2,r, the Minitnunt Desten Cfitenitt for the Permitting of Pow Stations and Force MainsAlatest version), and the Gravity Sewer Nlittim tun Design Criteria (latest versioo) as applicable? Yes El No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review, Approval of the request is requiredprior to submittal of the Fast Track Application and supporting documents. Professional Engineer's Certification: Jo A D (Professional Engineer's 1, 0 ame from Application11.1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shalt be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T ,0106(b): (Signatuif Authorityname & title from Application Item 1.3.) attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, andlor criminal prosecution, I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE In accordance with General Statutes I 4,;.215. A and 14.;-21,5,61i, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Date: /C) FORM: FTA 04-16 Page 5 of 5 .".stmv ot .North `411"4iiirfa Departilictit low, ii*Olittleffra Ottaiit ilft‘itOtori ‘‘ liter kesourkx, rio‘k' itrar'king - A HAP:: .kotitototr tot„ \ank: Ck.0: VOlk:h tliNi hk...00::„: tOttiAt' 'orctisow tkppitc.:4Sion, Wore nth n one I 1St mav he regnitren pa a n,,I;ac"pr,.,tt.',.,! tht'U 14P not .,a.alantSdnn. Inf ..#;tatiaarp, along !he twth: nt propowd wotewater /tow, orttpletc: tttApOttort of tto \\. p ,pccpti„; „Ind PC1';',011 'rq.111;01,.C4,i 110',A tit thaW,,, 4,1,a,' Ma) (4,0 otActpl,:r,t ttt,tAttior, :r,Ar kcattttitt ',AtAtt:1- tAtttItt— to„ttArt;AAArt,At ttAirt.torA ttAttAttr„N.,', t (ti't Be45©n Creek Ptt 0 Luc 0 21/4\0e5 (DO ocioe is5t9 a I t49 The Firm CApaelt, (design Wm)uii i&luined As the out 11 that can Pc Akilie‘ed %%kit the lartfcsi pewit tAken oni ,er-i.icco " Ocsign tif, forage 1-14'm pump.V 1I flit less than LS Per !"ection :M2( itu Vtinimim 114-,si!Jn Planning Assyssment ‘ddeodnie Aitatici.1 for cAott pump, ,httion nn,:ood betAkcen the project connection !now and 't'nf ‘-‘ NI* vi here au., miattic i\ 1, 0 1)i.M,n,LIvArr, tttt,Att i'Attztwtt: \CR \INhAl tototo,fR-tiv 'ttowfirtett- AIC GQ20 737 -81.3750' 35.25W" 466°°°R'E 67 68 69 70 71 75 KINGS MOUNTAIN QUADRANGLE NORTH CAROLINA - SOUTH CAROLINA 7.5-MINUTE SERIES 76 -a7.z5a© 77 The Na[ional Map USTopo 77 73 74 ,E 1:24 000 KILOMETERS 4. METERS 1000 0 MILF-S 000 5000 FEET JR INTERVAL 20 FEET AN VERTICAL DATUM OF 1988 vdtrced to conform with the -arrt U5 Topo Product Standard, 2011. with this product is draft version 0.6,18 2000 1 10000 74 QUADRANGLE LOCATVON ADA:00HG QUADRANOL 1 Waco 2 Bessemer City 3 Gastonia North 4 Grover 5 Gastonia South 6 Kings Creek 7 Filbert 8 Clover Henry Knob 75 76 ROAD CLASSIFICATION 477 000ME Expressway zww, Local Connector --- Secondary live/ Local Road Ramp •4WD ip Interstate Route ) US Route 0 State Route KINGS MOUNTAIN, NC, SC 2019 -81,2500" 35.1250' September 30, 2019 DEQ Division of Water Resources Mooresville Regional Office 610 E. Center Avenue Mooresville, NC 28115 SUBJECT. Hall Crossing Subdivision Phase 5 o Wh,orn It May Concern: We are proposing to install approximately 350 linear feet of 8' sanitary sewer line and 1120 linear feet of 6" sanitary sewer to serve 7 residential lots. These lots are located in Kings Mountain, NC. and the sewer line will belong to the City of K.nigs Mountain once completed. If you have any questions, you may contact me at 7f14-92240.024. Sincerely, nDenton, PE, PLS and Engineering, PLLC.