Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0032623_Regional Office Historical File Pre 2018
Miehae. F. Easley, Governor William G. Ross .Jr.„ Secretary North Carolina Department of Environment and, Natural Resources Coleien H. Sullins, Director Division of Water Quality January 23, 2008 The Honorable Edgar Murphrey, Mayor City of Kings Mountain 1013 N Piedmont Ave PO Box 429 Kings Mountain, NC 28086 Subject: Permit No, WQ0032623 Ingles Sewer Wastewater Collection System Cleveland County, North Carolina Dear Mr, Murphrey, In accordance with your application received on January 8, 2008, we are forwarding herewith Permit No. VVQ0032623 dated January 23, 2008, for the construction and operation of the subject wastewater collection system extension This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference, Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, \!oi ciIle RcgioriI Office 6111 East Center Ave, Suite 301 Mooresville,. NC 28115 Internet: www,ncrnwalerquality.org Customer Service.' 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper Phone: (704) 663-1699 Fax: (704) 663-6040 Ore. NoottCarolma Naturally PPlirMr, Murphrey Page 2 January 23, 2008 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 1,394 linear feet of 8-inch gravity sewer and the discharge of 5,025 gallons per day of collected domestic wastewater into the City of Kings Mountain's existing sewerage system, pursuant to the application received December 13, 2007 and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of kings Mountain's WWTP (NPDES No. NC0020737) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714, Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely .Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files D. W. Odom, Odom, Hollifield & Assoc. Engineering, Inc, Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERM T This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 21; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein, 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data, The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T 0403; a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L.. .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained, c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time, f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years, h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215,1C 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State, 6 Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7 A copy of the construction record drawings shall be maintained on fie by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C, In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities 10 The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H 0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.: or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report, Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence, This report shall outline the actions taken or proposed to ensure that the problem does not recur, Part II of Form CS-SSO (or the mast current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 23rd day of January 2008i NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION al. 4 77 4,7:73 fir Coleen H Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Nititther WQ0032623 n. Fast Track Engineering Certification Permit No WQ0032623 January 23, 2007 Owner!WQCSIWWTP PE Edgar Murphrey, Mayor D W Odom City of Kings Mountain Odom, Hollifield & Associates Engineerng, Inc. PO Box 429 152 E Main Street Kings Mountain, NC 28086 Forest City, NC 28043 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are re uired for an &Ian es resultin in non-com nce with this ermi re ilations minimu in design criteria, This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. r ENGINEER'S CERTIFICATION Partial LT Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ([1 periodically, El weekly, LI full time) the construction of Ingles Sewer, a Cleveland County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T: the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable, the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable: and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, APPLICA'I0i for GRAVI'T"ia' S RS, P P STATIONS, AND FORCE MAINS PAGE 3 O • 1 b. Edgar O. Murphrey Jr -Mayor 0 lid z z 0 1- .J d d z 0 2 1 c. Signing Official Name and Title (Please revi The legal entity who will own this system is: Q Individual Q Federal Municipality 0 State/County Q Private Partnership © c 1 d, P© Box 429 Mailing Address 1f, NC _..._ . State 1 h, 704-734-0333 Telephone 2. Project (Facility) Information: 2a, Ingles Sewer Brief Project Name (permi 3. Contact Person: 3a, Scott Roach Name and Affiliation of So 3b, 828-247-44 Phone Number 1. Project is New Q Mo 704-734-4619 Facsimile efer tea this name) e 1 e. Kings Mountain City 1 g. 28086 Zip Code 1j. elainelrrcityo E-mail USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! 1'. Owner. la. C'it of kings Mautain Full Legal Name (company, municiipaltty, HOA, Iity, Application Number: (to be completed by D v0) NCAC 2H .0206(b) for authorized signing o oration Q Othe . com 2b. Cleveland County Where Project o Can Answer Questions About this Application 3c. 828-247-4498 E-mail tof an eristing permit) If Modification„ Permit No,: specify): ated For modifications, attach a separate sheet clearly explaining the reason for the modification (Le, adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in 7) and B(10-11) that has already been included in the original permit. 2. Owner is 2a. If private, Public (skip to Item B(3)) Q Private (go to item 2(a)) cant will be: 2b.. If sold, facilities owned by a (must choose one) Q Retaining Ownership (i.e, store, church, single office, etc.) or Q Public Utility (Instruction III) • Leasing units (lots, townhomes, etc. - skip to ltrem B(3)) p Selling units (lots, townhomes, etc_ - go to ?tom B(2b)) City of Kings Mountain Q, Homeowner Assoc /Developer (Instruction IV) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. Pilot Creek WWTF Name of WWTF 5a, Cies+ of Kings _Mountain 5b, 8" Gravity 5c. owner of Downstream sewer Receiving Sewer Size 0 Force Main 6 The origin of this wastewater is (check all that apply)„ 0 Residential Subdivision Q Apartments/Condominiums Q Mobile Home Park Q School Q Restaurant Q Office Volume of wastewater to be al 4b. NC0020737 WWTF Permit No.. Permit Number of Downstre: O Car Wash © instiitution O Hospital 0 Church Q Nursing Home Other (specify), Imiles Supermarket is particular project: 5025 gallons per day *Do not include previously permitted allocations 8. if the permitted flow is zero„ indicate why: © Interceptor Line - Flow will be permitted in subsequent permits that connect to this line Q Flow has already been allocated in Pemnit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected % DomesticICommercial % Industrial % other (specify): FRACK APPLICA I ION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9, Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below Values other than that in 15A NCAC 2H .0219(1X 1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H ,0219(1)(3). Gas Station - 125 gpd, Supermarket - 100 employees j 25 gpd, Carwash - 2400 gpd. = 5025 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main (use the pull down menu) 8" C900(DR-18) PVC 1091 Gravity CL350 DIP 303 Gravity ENTER TOTAL LINE LENGTH IN MILES 0 26 11 0 Summary of Pump Stations to be Permitted (attach additional sheets as necessary) 2 0 2 Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3- plans for cross-reference) (MGD) GPM fp TDH portable generator kit/telemetry; 4-wet well storage) NA 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H ,0200 as applicable? Yes El No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/c-ertifications been submitted for approval? Wettand/Stream Crossings - General Permit or 401 Certification? 0 Yes No D N/A Sedimentation and Erosion Control Plan? Yes 0 No D N/A Stormwater? El Yes No I N/A 14 Does this project involve aerial lines or siphons? Check if yes: D These Ones will be considered hiciti priority and must be checked once event SU months 15 Does this project have gravity sewer lines designed at minirnum slopes? Be aware that the Division will not accept installed lines more than 10% flatter than the minimum slope. Lines meta corrected prior to submating the final engineering cerfiTioation h' Id PLICATION for GRAVITY SEWERS, PUMPSTATIONS, AND FORCE MAINS PAGE 5 --'- C. • Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS) to collect and record the stream classification data below (attach additional sheets as necessary), This document is available frorn our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following. A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, 0 A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope vraterbody, Location ID on Map (self chosen - as shown on Name of map for cross-reference) Waterbody la, Waterbody Stream Waterbody County River Basin Index Classification Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: I, Edgar O. Murphrey Jr., attest that this appfication for Imps Sewer has been reviewed by me and is accurate and complete to the best of my knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215,6A and 143- 15.613, any person who knowingly makes any false statement, representation, or certification in any ap sh be guilty ofa Class 2 misdemeanor which may iriclude a fine not to exceed $10,000 7 altie o violation. Si ing "al Si ature 2. professional Engineer's !edification: VAt; 0 ci /.(/ Date attest that this °peke eon for lngles Sewer has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division gukfance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged It to be consistent with the proposed design Note: in accordance with NC General Statutes 143-215.6A and / 43-215,6B, any person who knowingly makes any faise statement representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10000 as well as civil penalties up to $26,000 per 'violation. 2a. David Odom Professional Engineer Name 2b. Odom & Assoc„Engineering, Inc Engineering Fin-n 2c. 152 E. Main Street Mailing Address 2d. Forest Cfty City 2e. N 2f. 28043 ate Zip 2g. 828-247-4495 2h 828-247-4498 2i. davdodomodomengineenng Telephone Facsimile E-mail Seal, S4nattge & Date IopoZone - USGS Waco (NC) Topo Map Page 1 of 1 r 0 0.1 0.3 0.4 0.5 km 0 0.18 t . 7 0.36 0.45 mi 35° 15' 27"N, 81° 22' 52"W (NAD83/WGS84) USGS Waco (NC) Quadrangle Projection is UTM Zone 17 NAD83 Datum G=-0.22 http //www.topozone.corniprint.asp?lat=35.2574&lon=-81.38113&s=258zsize=l&u 6&laye... 1/4/2008 Central Files: APS SWP' 01 /2 108 Permit mbar WQ00 2623 Perm Tracking Slip Program Category Non -discharge Permit Type Fast Track Status Active Project Type New Project Version Permit Classification Gravity Sewer Extension, Pump Stations, Pressure Sewer 1.00 Individual Extensions, Primary Reviewer dee.Crowder Permitted Flow 5025 Facility Facility Name moles Sewer L.uatin Address Owner Owner Name City° of kings 1 fountain Dates/Events it Contact Affillatitn Major/ 'in r Region Minor Mooresville County Cleveland Facility Contact Affiliation Owner Type Government Municipal Owner Affiliation Edgar 101 W Gold at Kings Mountain Murhrey, Jr NC 28086 Scheduled Ong Issue App Received Craft Initlatnd I rrarrca Public Notice Issue Effective 01/22/08 01/08/08 01/.2/08 01/22/08 Regulated Activities rroery Store 1� apt water collection Ouffall Eenuested/Rqceived Events Additional Information requested Additional information received Expire Wterbdy Name Index Nu r rber Curren( Class Sub b s`n TO THE ORDER OF THE CITY ©F KINGS MOUNTAIN GENERAL FUND I UTILITY FUNDS P.O. BOX 429 , KINGS MOUNTAIN, NC 28086 DATE o1/04/2008 PAY EXACTLY 90248 N"D`NR $480* DOLLARS AND * 0 0 * CENTS THIS DISIURSEMENT HAS BEEN APPROVED THE LOCAL GOVERNMENT BUDGET AND FISC 0059? LOu' 1;053, 10 16aI is 00 i LL, 33 28111' Micnael r~: Governel v am G ROSS Jr Se.c.ltary North Carolina rDep.art,ment, JEnylronrnent and Natural Resources .4tig '44,4.03% Nita./ 13, 2008 City of Kings Miountclin Box 429. Kings Mountain, North Carolina 2'8086 „ATTN: Edgar Nilurphrey, tvt.ayor SUBJCT Ingres. Sewer Permit No WQ003.2623. iiiiiaste\sfater Collection System Extension Final Engineering Certification Dear Permititeei Coleen .Sluilns, Director ay.s4on °PA/later Quality The Division received a final engineering certification for the .subject prolect on April 17, 2008s A full review of the certificiation materials may cr may nicit• e conducted„ It is assumed that receipt of this certification indicates compliance with ail regulations, design criteria and the permit, Please be reminded that the Permittiee is responsible for keeping a copy of the final record drawings for the life of the project, if you have not received a copy, 1,Djt-ii:asei contact your consultant immediately to obtain copy. You gre receiving this ietter because the Division has iyou listed as the responsible patty it (hiss permitted systerin is no longer at/tined isoyi ye U e OSe C: ligpiete Form PhicipCiFiiii os the ;us:arr.,' „ automatically tansferable, Form Priritlia°,0E-S can toe downirpoded from 3„ ennstote no (I-42u /ndpicia oos If you have any. questions concerning this document 0( he completion of Form PNOCHS (if necessary), pier:Ise contact Ms. Dee Brot,yi(aer at 1he iet.terhead address or via E.-hi-ait at ideebrowciernicimail,net, Sincerely, 4/2-1-15.x. Robert Krebs .race Water Protection Regioncli Supervisor Enciosure DC1Vid CdOrn, CdOrr, & Associates Engineering Surface Water Protection Sectsiort Central Files (certification page orsiyii One, North Cara na Pretrearrent Emecgency Response and Colleution Systems Unit Ilnternet, ht-tplin2o err nastate U'sincipd 1617 Ma Service Center, Ralesgh, NO 27699-1617 An Equal Opportunity AcFon Employer Tele;Dlnone F919) 733-'3083 Fax (9.19) 7371,0059 recydec1/10',.; post-consumec paper' Prr-Fast Track Enqineerinq Ce0032623 Permit No WOcation January 23, 2007 OwnerANQCSANWTP Edgar Murphrey, Mayor City of Kings Mountain PO Box 429 Kings Mountain, NC 28086 4r4Ir „I; PE UK Odom Odom, Hollifield & Associates Engineering, Inc 152 E Main Street !„,' Forest City, NC 28043 C" Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATIO Partial Final 7\t ( as a duly re4fered Professional Engineer in the State of North Carolina, having been authorized to observe (L1 periodically, LJweekIy, Ej full time) the construction of Ingtes Sewer, a Cleveland County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVtLLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions.