Loading...
HomeMy WebLinkAboutNCS000441_Audit Info Request Response_20210505 Morman, Alaina From: Myers, Sharon A <samyers@ehs.unc.edu> Sent: Wednesday, May 5, 2021 3:37 PM To: Morman, Alaina Cc: Powell, Jeanette; Brennan, Catherine; Hoyt, Sally C; Clarke, Janet L Subject: [External] UNC-Chapel Hill Response to MS4 Permit Compliance Audit Documentation Request Attachments: 2021 Draft UNC SWMP.pdf, EHS Hazmat Spill Response Map.pdf, March 2021-Illicit Discharge Policy.pdf, 2021 UNC-CH IDDE_SOP.pdf, UNC Stormwater Inspection and Maintenance Manual v. 2021-05-03.pdf, UNC-CH Stormwater Performance Criteria-Design Standards-and Procedures.pdf CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Hi Alaina, Please find attached,the documents that you requested in your letter dated April 29, 2021. a. Stormwater Management Plan (SWMP)-attached as 2021 Draft UNC SWMP b. Annual Reports not already submitted through DEQ's online BIMS SWMPA portal-all annual reports previously submitted via online portal c. MS4 Program Organizational chart and associated program responsibilities for staff/positions-included in attached 2021 Draft UNC SWMP (see Part 4.1 and Appendix B) d. MS4 map of outfalls and receiving waters-attached as EHS Hazmat Spill Response Map (shows major and minor outfalls) e. Formal stormwater program implementation agreements with any other entities-NA, no agreements with other entities f. Illicit Discharge Detection and Elimination Program Plan-attached as March 2021 Illicit Discharge Policy and 2021 UNC-CH IDDE SOP g. MS4 Operation and Maintenance Plan-attached as UNC Stormwater Inspection and Maintenance Manual h. Municipal SCM Operation and Maintenance Plan-All UNC-CH SCMs are considered Municipal SCMs, refer to attached UNC Stormwater Inspection and Maintenance Manual i. Post Construction ordinance reference or link-attached as UNC-CH Stormwater Performance Criteria, Design Standards and Procedures UNC-CH's industrial activities (Co-Generation Facility and Hazardous Materials Facility/Service Station) are regulated by two NPDES industrial stormwater permits. Both of these facilities operate under their own Stormwater Pollution Prevention Plans (SWPPPs). We also have a campus-wide Spill Prevention, Control and Countermeasure (SPCC) Plan. If you would like to see the SWPPPs or the SPCC Plan, please let me know and we will provide this documentation to you. 1 Thank you. Sharon Sharon Myers Environmental Compliance Officer UNC-CH EHS Dept. 1120 Estes Dr., CB 1650 Chapel Hill, NC 27599-1650 919-962-9752 2