Loading...
HomeMy WebLinkAboutWQ0028843_Application (FTSE)_20070202FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 Z 0 Let igsk tHEIFAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) 7 1. - Owner:', 1a: Town Cftillington Full Legal Name (company, municipality, HOA, utility, etc.) 1b. Tom Taylor, Interim Town Manager Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) 1 c. The legal entity who will own this system is: • Individual ■ Federal ►4 Municipality ■ State/County ■ Private Partnership ■ Corporation IN Other (specify): ld. 106 West Front Street le. Lillington Mailing Address City If. North Carolina lg. 27546 State Zip Code lh. (910) 893-2654 li. (910) 893-3693 1 j. vbwilson@charter.net Telephone Facsimile E-mail 2. Project (Facility) Information: 2a. Duncan Street Sewer Outfall Relocation 2b. Hamett Brief Project Name (permit will refer to this name) County Where Project is Located 3. Contact Person: 3a. Brian Sexton, P.E., Hobbs, Upchurch, & Associates, P.A. Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (910) 692-5616 3c. bsexton©hobbsupchurch.com Phone Number E-mail 1. Project is ■ New ►i4 Modification (of an existing permit) If Modification, Permit No.: WQ0028843 For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is y Public (skip to Item B(3)) • Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) IN Retaining Ownership (i.e. store, church, single office, etc.) or ■ Public Utility (Instruction III) ■ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ■ Homeowner Assoc./Developer (Instruction IV) • Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. Harnett County Public Utilities Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. North Hamett Regional Wastewater Treatment Facility 4b. NC 0021636 IOBBS, 'UPCHURCH ey'ASSOCIATES, P.A. CONSULTING ENGINEERS P.O. BOX 1737, 300 S.W. BROAD STREET SOUTHERN PINES, NC 28388 (910) 692-5616 Exactly Four hundred and no / 100 Dollars PAY TO THE ORDER OF: N. C. DENR NC BB&T Branch Banking and Trust Company 66-1121531 DATE 1/31/2007 VOID AFTER 90 DAYS 5W62Q29 AMOUNT $400.00 Details on back. 8 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: WQ0028843M (to be completed by DWQ) 1 Owner: la. Town of Lillington O lb. Tom Taylor, Interim Town Manager Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) Q 1 c. The legal entity who will own this system is: 2 ❑ Individual ❑ Federal ® Municipality 0 State/County 0 Private Partnership ❑ Corporation 0 Other (specify): • ld. 106 West Front Street le. Lillington LL LL Mailing Address City 1f. North Carolina lg. 27546 State Zip Code - lh. (910) 893-2654 1 i. (910) 893-3693 1j. vbwilson@charter.net ~ Telephone Facsimile E-mail Full Legal Name (company, municipality, HOA, utility, etc.) O 2. Project (Facility) Information: —.11 2a. Duncan Street Sewer Outfall Relocation 2b. Harnett n'CL Brief Project Name (permit will refer to this name) County Where Project is Located < 3. Contact Person: Q 3a. Brian Sexton, P.E., Hobbs, Upchurch, & Associates, P.A. NFORMATION Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (910) 692-5616 3c. bsexton@hobbsupchurch.com Phone Number E-mail 1. Project is ❑ New ® Modification (of an existing permit) If Modification, Permit No.: WQ0028843 For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is ® Public (skip to Item B(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) 0 Retaining Ownership (i.e. store, church, single office, etc.) or 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. Harnett County Public Utilities O Public Utility (Instruction III) ❑ Homeowner Assoc./Developer (Instruction IV) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project a. North Harnett Regional Wastewater Treatment Facility 4b. NC 0021636 Name of WWTF 5a. Harnett County Public Utilities 5b.18" ® Gravity Owner of Downstream Sewer Receiving Sewer Size ❑ Force Main The origin of this wastewater is (check all that apply): ® Residential Subdivision Z Apartments/Condominiums O Mobile Home Park ® School ® Restaurant ® Office Z Car Wash ❑ Institution 0 Hospital ® Church Z Nursing Home O Other (specify): WWTF Permit No. 5c. WQCS00297 Permit Number of Downstream Sewer (if known) 100% Domestic/Commercial Industrial °A° Other (specify): Volume of wastewater to be allocated for this particular project: ZERO gallons per day *Do not include previously permitted allocations 8. If the permitted flow is zero, indicate why: O Interceptor Line - Flow will be permitted in subsequent permits that connect to this Tine 0 Flow has already been allocated in Permit No. ® Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 - Rev. 3 04/05 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(1)(3). N/A 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 21" (PVC — primary pipe size) 24" (Ductile Iron along primary pipe size) 12" ENTER TOTAL LINE LENGTH IN MILES Length (feet) Gravity or Force Main (use the pull down menu) 2,475 Gravity Main 642 Gravity Main 20 Gravity Main 0.594 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) 0 Location ID i- (self chosen - as shown on Design Flow Operational Point plans for cross-reference) (MGD) GPM @ TDH cc 0 Z B. PERMIT Power Reliability Option (1- dual line feed; 2- permanent generator w/ATS; 3- portable generator w/telemetry; 4-wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? Z Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ® Yes ❑ No ❑ N/A Sedimentation and Erosion Control Plan? ® Yes ❑ No ❑ N/A Stormwater? ❑ Yes ❑ No ® N/A 14. Does this project involve aerial lines or siphons? Check if yes: El These lines will be considered hiah orioritv and must be checked once every six months 15. Does this project have gravity sewer lines designed at minimum slopes? Be aware that the Division will not accept installed lines more than 10% flatter than the minimum slope. Lines installed outside this tolerance should be corrected prior to submitting the final engineering certification.. FTA 02/03 - Rev. 3 04/05 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 C. STREAM CLASSIFICATION 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: ❑ A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND ❑ A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on map for cross-reference) 1 2 Name of Waterbody UT to Cape Fear UT to Cape Fear County Harnett Harnett Waterbody Stream Waterbody River Basin Index Classification Cape Fear Cape Fear 18-16.7 18-16.7 Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! WS-IV WS-IV . Applicant's Certification: 1, Tom Taylor, attest that this application for Duncan Street Sewer Outfall Relocation has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation. la. I' d-+�+- �F 30 Jam D 7 Signing Official Signature 2. Professional Engineer's Certification: Date I attest that this application for Duncan Street Sewer Outfall Relocation has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Fred M. Hobbs Professional Engineer Name 2b. Hobbs, Upchurch and Associates, P.A. Engineering Firm 2c. P.O. Box 1737 Mailing Address 2d. Southem Pines 2e. NC 2f. 28388 City State Zip 2g. (910) 692-5616 2h. (910) 692-7342 2i. f.hobbs@hobbsupchurch.com Telephone Facsimile E-mail 4.AaRO ��,-. ASS/p�.'� �► SEAL ' i-2`1-07 Seal, Signature & Date FTA 02/03 - Rev. 3 04/05 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 6 DFSCRIPTION OF PERMIT MODIFICATION This application is a modification to existing Permit No. WQ0028843 and decreases the 24" gravity main originally permitted to a 21" gravity main. This project was bid as a 24" PVC sewer main with the following alternates: 21" ductile iron sewer main, 18" PVC sewer main, and 18" ductile iron sewer main. After bids were received, the Town elected to award the contract for the 18" PVC sewer main due to the substantial cost savings. After award of the contract, a change order was executed to upsize this pipe to a 21" sewer main. Due to pipe materials available at the time of construction, all 21" ductile iron pipe sections were constructed as 24" pipe sections. FTA 02/03 - Rev. 3 04/05 • 1t 0§' .p9" 9�21* ' 9-49" i^f • 11 1111°7 *14f5' • 1 r f . NI i'r t/ • • 11 •-"use-- •-� a +h • • r—"! 'firIt I er`. f..t�:'� .� /• ■11. 1 1 Illlllllll I I f l l I1 ! I l l l l l l rl I I I I I I I I I I I rb�8� �' �b.bd'. �t l l l l l 1 1 1 bs� �' rti.bd" W bi° �' °r9°1-L1IIIIIIIII�N ewa e- Disposal — ivAi5t5r141:0 fj; • rP' fit 1 >t! r -f • • • • *, CO a •r7� , f r • it Dept, Dept q -or 9° W lions s d.do1` i I'f r11 1 1 1 1 1 Name: LILLINGTON Date: 4/1/2005 Scale: 1 inch equals 1000 feet Location: 035° 23' 53.7" N 078° 48' 29.5" W Caption: Town of Lillington-Duncan Street Outfall Replacement Copyright (C) 1997, Maptech, Inc.