Loading...
HomeMy WebLinkAboutWQ0042014_Regional Office Historical File Pre 2018Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15.A NCAC 02T .0300 -- FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: to be competed by DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: I. Applicant's name: jiyfConover (company, municipality, I-10A, utility, etc.) 2.. Applicant type: Lil Individual El Corporation Federal El State/County El General Partnership El Municipal 3. Signature authority's name: Donald E. Duncan, Jr. per I5A NCAC 02T .0106(b) Title: City Managel 4. Applicant's mailing address: P.O, Box 549 City: Conover State: NC Zip: 28613- 5. Applicant's contact information: Phone number: (828) 464-1191 Email Address: donald.dunca onovernc.gov RECEIVEDINGDENRIDWR WQR(„iS MOO A ES%„/ILLF, E] Privately -Owned Public Utility LI Other 11, PROJECT INFORMATION: 1. Project name: New Wendy's Restaurant 2 Application/Project status: Proposed (New Permit) El Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Catawba 4. Approximate Coordinates (Decimal Degrees): Latitude: 35 729033Longitude: -81.208083' 5. Parcel ID (if applicable): 374206479539 (or Parcel ID to closest downstream sewer) 111. CONSULTANT INFORMATION: 1. Professional Engineer: Alan J. Crees License Number: 027044 Ivlunicipal Engineering Services Company, PA Mailing address: 82.0-13 State Farm Road City: Boone State: NC Zip: 28607- Phone number. (828) 262-1767 Email Address: acreeskinesco.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Northeast Wastewater Treatment Plant Permit Number: NC 0024252 Owner Name: City of Conover V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I. Permit Number(s): WQ 00088 Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS 00088 Owner Name(s): City of Conover FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? Yes 0No N/A 2, If the Applicant is a Developer of lots to be sold, has a Developer's _Operational Agreement_l_FORM: DEV) been attached? Yes ONo N/A 3. If the Appli • a Home/Property OwnersAssociation_has an Operational Agreemen (FORM: HOA) been attached? 0 Yes 0No N/A 4. Origin of wastewater: (check all that apply): 0 Residential Owned 0 Retail (stores, centers, malls) 0 Residential Leased 0 Retail with food preparation/service 0 School / preschool / day care El Medical / dental / veterinary facilities Z Food and drink facilities 0 Church Businesses 1 offices / factories 0 Nursing Home 5. Nature of wastewater DomestielCommercial 100. % Commercial _ % Industrial (See 15A NCAC 02T .0103(20)) > Is there a Pretreatment Program in effect? Has a flow reduction been approved under 15A NCAC 02T .0 I I4(f)? Ej Yes ), If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see NT.0114f)) Restaurant, Single Service Articles Daily Design Flow 20 gal/seat gal/ gali gal/ gal! El Car Wash 0 Hotel and/or Motels rj Swimming Pool /Clubhouse 0 Swimming Pool/Filter Backwash El Other (Explain in Attachtnent) 0 Yes 0 No N gall No. of Units 67 Flow 1,340 GPD GPD Total GPD GPD GPD GPD 1,340 GPD a See 15A NCAC 02T ,0114(b), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas, and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42ALI). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. Wastewater generated by project: 1,340 GPD (per 15A NCAC 02T .0114) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why, LJ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line Li Flow has already been allocated in Permit Number: 0 Rehabilitation or replacement of existing sewer with no new flow expected Z Other (Explain): FORM: ETA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (I'Applicable) 02T,.0305 & IYIDC,(Gravtity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) > Section 1184 111 of the MDC fair Permitting of Gravity Sewers contains infor-rnation related to design cri • Section 111 contains infonnation related to minimum .slopes for gravity sewer(s) • Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains'; COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: . Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4, Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDFI) 5. Summarize the force main to be permitted (for this Pump Station): 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry= 15:.A NCAC 02T ,0305(h)(l)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ), Must be permanent to facility Or if the pump station has an average daily flow less than 15,000,gallons per day: 0 Portable power source with manual activation, quickconnection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or © Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): • It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ lithe portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations" storage capacities and the rotation schedule of the portable power source or pump, including travel tixnefrarnes, shall be provided in the case of a multiple station power outage. FORM: PTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & I5A NCAC 02T .0305(0): 1. Does the project comply with all separations found in 15A NCAC 021..0305(0 & Lgj >•-• I 5A NCAC 02T.0305(0 contains minitnum separations that shall be provided for sewer s : Setback Parameter* Storm sewers and other utilities not listed below (vertical) Water mains (vertical -water over sewer including in benched trenches) mains (horizontal) Reclaimed water lines (vertical - reclaimed over sewer) Reclaimed water lines (horizontal - reclaimed over sewer) **Any private or public water supply' source, including any wells, WS-I waters of Class I or Class unded reservoirs used as a source of drinking, water aters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB ft-orn normal water (or tide elevation) and wetlands (see item IX,2) **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches Any building foundation basement o.e of embankment o Draina systems and interceptor drains An swimmingpools final earth grade(yertica )1 more vertical height Yes 1 INo oration Required 24 inches 18 inches 10 feet 18 inches 2 feet 100 fee 10 feet 5 feet 10 feet 6 inches • I5A NCAC 02T,0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved, ). **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage If noncompliance with 02T,0305( f) or (g), see Section X of this application 2, Does the project comply with separation requirements for wetlands? (50 feet of separation) El Yes El No DA N/A • See the Division's draft separation requirements for situations where separation cannot be meet • No variance is required if the alternative design criteria specified is utilized in design and construction • As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per I 5A NCAC 02B .0200? LI Yes E No N/A • This would include Trout Buffered Streams per J 5A NCAC 2B4O202 4, Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? • Information can be obtained from the 401 & B r Pe El Yes No 5. Does project comply with 15A NCAC 02T0105(c (6) (additional permits/certifications)? Yes Ej No Per I 5A NCAC 021'.0 105(0(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6, Does this project include any sewer collection lines that are deemed "high -priority?" Per I5A NCAC 02T.0402,, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. [I] Yes No EI N/A • Byes, include an attachment with details for each line, including type (aerial line, size, material, and location), High priority lines shall be inspected by the perm ittee or its representative at least once every six -months and inspections documented per l5A NCAC 02T.0403(a)(5) or the permitce's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X, CERTIFIC. TIONS: Does the submitted system comply with 15A NCAC 02T, the Minimun D Criteria for t e Permitting of P 'ta i and Force Mains (latest version], and the Gravity Sewer Minimum Design Critert on) as applicable. Yes E] No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review, Approval of the request is required prior to submittal of the Fast Track Application and supporting documents, 2. Professional Engineer's Certification: re€.6 (Professional Engineer's name from Application Item IBA.) attest that this application for has been reviewed by the and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge, 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Cass 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. \ \\\ CARo North Carolina Professional Engineer's seal, signature, and date: 4/ • " •. 0 I SEP1 27044 3, Applicant's Certification per 15A NCAC 02*F .0106(b): (Signature Authority's name from App 'cation Item 1.3.) attestthat this application for has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. 1 will make no claim against the Division of Water Resources should a condition of this permit be violated, 1 also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete, NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, Date: FORM: ETA 04-16 Page 5 of 5 Pump Pump Station Station (Name or Permit Number) No, Division or YY.Oit-r fris,ou“ State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications tFTSE 10-18) Entity Requesting Allocation: City of Conover Project Name for which flow is being requested: New Wendy's Restaurant Afore than one FTSE may he required Or a single project if the owner of the WWTP is not responsiblefirr all pump stations along the route .of the proposed wastewater flow. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: City of Conover Northeast Wastewater Treatment Plant b. WWTP Facility Permit #: NC0024252 Auto vs are in MGD c. WWTP facility's permitted flow 1.5 d. Estimated obligated flow not yet tributary to the WWTP .323172 e. WWTP facility's actual avg. flow 0,974 f. Total flow for this specific request 0.00134 g. Total actual and obligated flows to the facility 1.2985 h. Percent of pennitted flow used 86.7% If. Complete this section for each pump s ation you are responsible for along the route of this proposed. xvastewater flow. List pump stationsocated between the project connection point and the WWTP: (A) (B) (C) (D)=-(B+C) (E).=(A-D) Design Obligated, Average Approx, Not Yet Total Current Daily Flow" Current Tributary Flow Plus (Firm I pf), Avg. Daily Daily Flow, Obligated Available MG[) How, MGD MGD Flow Capacity*** Capacity, * MGD * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. **Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less. than 2.5, per Section 2,02(A)(4)(c) of the Minimum Design Criteria. '* A Planning Assessment Addendum shall he attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < O. Downstream Facility Name(See Downstream Permit Number: Page 1 of 6 FTSE 10-18 Certification Statement: Donald E. Duncan, Jr. certify to the best, of my knoww'ledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation station of the planned improvements identified in the planning assessment wvhere applicable. This analysis has been perfo teed in accordance with local established policies and procedures using the best available data, This certification applies to those items listed above in Sections 1 and 1 plus all attached planning assessment addendums for which I ,arn the responsible party. Signature of this form certifies that the receiving collection system or treatment ww°i-arks has adequate capacity to transport and treat the proposed new wastewater, Page . cat FTSE 10-1 USES TOPO MAP NEW WENDY'S RESTAURANT SEWER MAIN EXTENSION CONOVER, NC SCALE: 1" = 500' START NEW 8" GRAVITY SEWER MAIN AT EX. SEWER MH END NEW 8" GRAVITY SEWER - MAIN AT NEW SEWER MH. BEGIN 4" GRAVITY SEWER SERVICE NORTHERN DRIVE NORTHWEST - NEW WENDY'S RESTAURANT EX. 8" GRAVITY SEWER MAIN, TYP. EX, GRAVITY SEWER SERVICE NEW GRAVITY SEWER MH, TYP. NEW 685 LF 8" SDR 35 PVC GRAVITY SEWER MAIN NEW 4" GRAVITY SEWER SERVICE NEW SUBDIVIDED PARCEL BOUNDARY EX. SEWER MH STA. 0+00 RIM = 932.59' NEW 8" PVC IN = 927„40'± EX. 8" PVC IN SE = 927.19" EX. 8" PVC OUT =. 927.19` 125 LE NEW 8" SDR 35 PVC GRAVITY SEWER © 5.92% NEW SEWER MH al STA. 1+25.00 RIM =941.00' 8" PVC IN = 935.00' 8" PVC OUT = 934.80' A A. 0'20'57" RT. CHURCH 355 IF NEW 8" SDR 35 PVC GRAVITY SEWER 0 0.75% STREET LEVEL MAP NEW WENDY'S RESTAURANT SEWER MAIN EXTENS NC HWY 16 & NORTHERN CONOVER, NC NEW MH 02 STA. 4+80.05 RIM = 943.25' 8" PVC IN = 937.86' 8" PVC OUT = 937„66' A = 2°54'08"RT. SCALE: 1.,"` 100" DATE: 7/14/2020 .CHKD. BY: AJC PROJECT NUMBER: B 19037.3 r RAWING NO. SLM-1 SHEET NO. 1 OF 1 205 LF NEW 8" SDR 35 PVC GRAVITY SEWER t1.75°, NI W STORMWATER BIORETENTION CELL/ DETENTION POND NEW MH 03 STA. 6+84.55 RIM = 947.50' 4" PVC IN = 9.39.96' 8" PVC OUT = 939.40" E1 = 83°15'21" RT. NEW 4" SDR 35 PVC SEWER SERVICE WENDY'S [AURANT NORTHERN DRIVE NORTHWEST MUNICIPAL ENGINEERING SERVICES COMPANY, P.A. 68 SHIPWASH DRIVE, GARNER, NC 27529 ` PHONE: 919-772-5393 820.8 STATE FARM ROAD, 80ONE, NC 28607 " PHONE: 828.262-1 767 LICENSE NUMBER: C"0281 Ft E 1 V E C r w WQRaS REGONAL, OFFICE PROJECT NARRATIVE New Wendy's Restaurant Sewer Main Extension City of Conover, Catawba County, NC 7-22-19 This Fast -Track Sewer Application is for a total of 685 linear feet of new 8-inch SDR 35 PVC gravity sewer main to extend the existing gravity sewer main for the development of a new Wendy's Restaurant at the corner of NC Highway 16 and Northern Drive Northwest in the City of Conover, NC. The new restaurant will be located on 2.73-acre parcel of land that is being subdivided off a larger parcel that is presently owner by the Tri-County Baptist Church of NC. The 2.73-acre parcel is further divided into approximately 1.05-acres for the Wendy's restaurant development, approximately 1.00 acre for a future commercial development and the remaining 0.68 acres for the stormwater bioretention cell/detention pond for both the Wendy's and future commercial developments. The new 8-inch gravity sewer main will connect to the existing gravity sewer manhole that is located adjacent to the existing church parking lot and is approximately 800 linear feet northwest of the new restaurant building. The new 685 linear feet of 8-inch gravity sewer main will run parallel to the existing church parking lot past the new stormwater bioretention cell/detention pond on the subdivided parcel to the northeast corner of the future commercial development area. Once past the new stormwater bioretention cell/detention pond, the new gravity sewer to serve the future commercial development and the Wendy's development will be a 4-inch service line. Sewage flow will not be routed through the new 8-inch gravity sewer main until it has been tested and certified. The volume of wastewater calculated for comes from a total of 67 seats for customers at the new restaurant building. The new restaurant will generate of total daily wastewater flow of 1,340 gallons per day, based upon a flow rate of 20 gallons per day per seat. LETTER OF TRANS DATE: 9-23-2020 TO: NCDEQ Division of Watei Mooresville Regional Offk 610 E. Center Avenue Mooresville, NC 28115 FROM: Alan J. Crees, PE RE: Fast -Track Sewer System Application for New Wendy's Restaurant Sewer Main Extension, Conover, ANC PROJECT NO.: B19060.3 WE ARE SENDING YOU: TRANSMITTED: ECF'11A, D.1N1^.. ENR/,PW R Fast -Track Sewer S stem Application:" Flow Tracking/Accestance Form FTSE 04-16 $480 Application Fee Check #145067 FOR YOUR USE/FILE FOR REVIEW/COMMENT FOR APPROVAL FOR SIGNATURE AS YOU REQUESTED AS REQUESTED BY: FOR YOUR INFORMATION FOR REMARKS: This permit application is for the extension 685 linear feet of 8" gravity sanitary sewer main or the development of a new Wendy's Restaurant at intersection of NC Highway 16 and Northern Drive NW in the City of Conover, NC. See Project Narrative for furtier details. VIA: 1ST CLASS MAIL ❑ FAX HAND DELIVERED PICK UP Ei COPY: Tige Darner, CFO, FFC Limited Partnership Transmitted from the Boone, NC Office of Municipal Engineering Services Company, P.A. License No. C-0281 820-B State Farm Road — Boone, North Carolina 28607 Phone (828) 262-1767 — Fax (828) 265-2601 — E-mail (general): mescoAbopne.net LETTER OF TRANSMITTAL DATE: 9-29-2020 TO: NCDEQ Division of Water Resources Mooresville Regional Office Attn: Debbie Luckman 610 E. Center Avenue Mooresville, NC 28115 FROM: Alan J. Crees, PE RE: Fast -Track Sewer System Application for New Wendy's Restaurant Sewer Main Extension, Conov r;'��� PROJECT NO.: B19060.3 WE ARE SENDING YOU: ROS -' ON1!.,3::: Copies Date 9-23-20 -22-20 No, -5 -2 Description Original Fast -Track Sewer System Application (FTA 04-16) Original Flow Tracing/Acceptance Form I,FTSE 04-16) TRANSMITTED: FOR YOUR USE/FILE FOR APPROVA AS YOU REQUESTED FOR REVIEW/COMMENT FOR SIGNATURE AS REQUESTED BY: FOR YOUR INFORMATION FOR REMARKS: VIA: , 1ST CLASS MAIL FAX J HAND DELIVERED PICK UP COPY: Tige Darner, CFO, FFC Limited Partnership Transmitted from the Boone, NC Office of Municipal Engineering Services Company, P.A. License No. C-0281 820-B State Farm Road — Boone, North Carolina 28607 Phone (828) 262-1767 — Fax (828) 265-2601 — E-mail (general): mesco(c boone.net