HomeMy WebLinkAboutWQCS00202_Annual Report_20210510 2020 Brunswick Regional Water & Sewer, H2GO
Wastewater Collection System
Annual Report
Permittee Brunswick Regional Water and Sewer H2GO RECEIVED
P.O.Box 2230 1 0 2021
Leland,NC 28451
Responsible Person: Keith D,Gore NCDEQ/DWR/NPDES
Collections System Superintendent/ORC
P.O. Box 2230
Leland,NC 28451
(910)279-9568 Cell
(910)371-9949 Office
(910)371-6441 Fax
Permit No.: WQCS00202
Name: Brunswick Regional Water and Sewer H2GO(BRWS)
During the 2020 physical year,Brunswick Regional Water and Sewer H2GO added 13,705 linear feet of
low pressure collection lines. This brings the wastewater collection system total to 42.40 miles of force
main and 112.02 miles of gravity pipe ranging from eight through twelve inch diameter pipe. In addition
to the piping,there are 54 pumping stations that are equipped with standby generators for emergency
power.There are 85 Grinder Pumps that are the direct responsibility of H2GO and 819 Grinder Pumps
that remain the homeowner's responsibility. These grinder pumps collect and lift the wastewater from low
areas to main outfall lines that flow to the Belville Wastewater Treatment Plant and to the Northeast
Regional Wastewater Treatment Plant. The average flow of wastewater generated by the collection
system that is treated at the Belville WWTP is 407,000 gallons per day with an additional 359,100 gallons
per day diverted to the Northeast Regional WWTP. The average flow of wastewater generated by the
collection system that flows directly to the Northeast Regional WWTP is 583,900 gallons per day for a
total of 943,000 gallons per day treated at the Northeast Regional WWTP.
PERFORMANCE
Although there was one reportable sanitary overflow during this reporting period on December 22 2020,
BRWS is aggressively working to upgrade and improve the collection system by following a maintenance
program requiring at least ten percent of the system to be cleaned each year. This year the Collections
Department cleaned 10.3 percent which was 11.51 miles of lines including visual inspection of the
manholes and lines through remote video.Along with the cleaning and inspections, Smoke Testing of the
collection system has been completed along with the sewer modeling of the entire collection system.
Furthermore,a Grease Ordinance has been adopted by BRWS and an Inspection Program has been
implemented which has led the BRWS Maintenance Department to take a "STOP IT NOW"attitude
toward Inflow and Infiltration wholeheartedly. Finally, operational checks of the pump stations,telemetry
and generator backup power are done on a weekly basis.
EDUCATION
My sewer is stopped up! I don't understand why it's not working right!
My toilet won't flush; what's wrong?
In the Wastewater Collections Department, we hear this on a daily basis, however most sewer problems
can be prevented BY THE CUSTOMER. The majority of stop ups are caused by a buildup of grease in the
lines. You can help prevent SSO(Sanitary Sewer Overflow)by reducing the amount of grease and fats
that's put into the wastewater system. Your friends in the Wastewater Collections Department are trying
their best to prevent problems in the wastewater collection system, please help them out by NOT pouring
fats,oils,or greases(FOGs)down the drain. The work we have to do to handle grease and oils in the
collection system makes operating cost go up, and when operating cost go up, so does the cost of living.
PLEASE HELP KEEP COST DOWN BY FOLLOWING THESE SIMPLE GUIDELINES:
➢ DON'T pour FOG from cooking down the drain.
➢ DON'T put anything down the drain that doesn't belong there; paper towels, personal hygiene
products, food scraps(unless you have a garbage disposer), disposable diapers,or any other
foreign objects.
In addition to blockages,INFLOW AND INFILTRATION sometimes causes SSO's during heavy rains.
Missing and broken cleanout caps, broken or improperly set manhole lids, contribute to this problem. Be
observant when you drive and travel around the BRWS district and let us know if you see anything that
doesn't look right. A single broken cleanout can allow up to 4,600 gallons of water to enter the
wastewater system each hour. All this adds to higher treatment cost for BRWS.
NOTIFICATION
A mailing list was developed from customer billing records and each customer was mailed a copy the
Performance Annual Report. A copy of this report can also be found on our website;
http://www.H2GOonline.com/annual-reports.
CERTIFICATION
I certify, under penalty of law, that this report is complete and accurate to the best of my knowledge. I
further certify that this report has been made available to the users or customers of the named system and
that those users have been notified of its availability.
Milton Lane Asst. Director/ORC Keith D, Gore Collection/ORC
516 Village Road 516 Village Road
Leland,NC 28451 Leland,NC 28451