Loading...
HomeMy WebLinkAboutNC0073571_Draft Permit_20210511 .o STATE o;' ROY COOPER ii ' Governor � . DIONNE DELLI-GATT[ ,= ,: Secretary ''-`$ .„ S.DANIEL SMITH NORTH CAROLINA Director Environmental Quality May 11, 2021 Todd Nunn President—Mervyn R.King 7700 US Hwy 158 Stokesdale,N.C. 27357 Subject: DRAFT NPDES PERMIT NC0073571 Countryside Manor WWTP Grade II Biological WPCS [15A NCAC 08G .0302] Guilford County Dear Mr. Nunn: Enclosed with this letter is a copy of the draft permit for your facility. Please review the draft very carefully to ensure thorough understanding of the conditions and requirements it contains. Your permit is among several in the Cape Fear River Basin that the Division has targeted for expedited renewal. This draft contains the following changes from the existing permit: ➢ Facility Classification -The facility's classification was added above the effluent table. ➢ Ammonia Nitrogen (NH3-N) Limits and Monitoring — The current permit requires monitoring weekly for NH3-N with effluent limits in place. In Section A. (1), which corresponds to the 0.015 MGD flow tier,the previous summer ammonia limits were a Daily Maximum of 27 mg/L and a Monthly Average of 5.4 mg/L, while winter limits were a Daily Maximum of 35 mg/L and a Monthly Average of 23.5 mg/L. Recent review by Division staff has noted that 15A NCAC 2B .0404(c) requires that winter waste load allocations for oxygen consuming waste be no less stringent than 2 times the summer waste load limit. To meet this rule requirement,winter limits for NH3-N must be adjusted in the permit.The new Monthly Average winter ammonia limits based on current EPA criteria is adjusted to 10.8 mg/L. In Section A.(2), which corresponds to the 0.030 flow tier, ammonia limits were similarly adjusted. Summer limits were a Daily Maximum of 16.0 mg/L and a Monthly Average of 3.2 mg/L,while winter limits were a Daily Maximum of 35.0 mg/L and Monthly Average of 13.0 mg/L.To meet requirements set forth in 15A NCAC 2B .0404(c),the new ammonia winter limits for section A.(2) are 32 mg/L Daily Maximum and 6.4 mg/L Monthly Average. ➢ Electronic Reporting-The language in section A.(3)has been updated to be consistent with the finalization of federal requirements for electronic reporting. The NPDES standard conditions(Parts II, III, and IV)that are a part of the permit are not included in this draft document(cover, map, and Part I).The conditions are the same as in your _ Q`J/ North Carolina Department of Environmental Quality I Division of Water Resources DE 512 North Salisbury Street 11617 Mail Service Center I Raleigh,North Carolina 27699-1617 an.r.t+it.,n.*\ 919.707.9000 current permit. The latest version is available at https://bit.ly/2BZ4xxx and can be viewed online or downloaded as a PDF file. With this notification,the Division will solicit public comment on this draft permit by publishing a notice in newspapers having circulation in the general Guilford County area, per EPA requirements. Please provide your comments, if any, to me no later than 30 days after receiving this draft permit. Following the 30-day public comment period,the Division will review all pertinent comments and take appropriate action prior to issuing a final permit. If you have questions concerning the draft, please contact me via email at[emily.delduco@ncdenr.gov] or call 919-707-9125. Sincerely, Laff_ .ii(4.(3 Emily DelDuco Environmental Specialist II NPDES Program ec: NPDES files Winston Salem Regional Office Public Water Supply Page 2 of 2 Permit NC0073571 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Dr. Mervyn R. King is hereby authorized to discharge wastewater from a facility located at the Countryside Manor WWTP 7700 U.S. Highway 158 Guilford County to receiving waters designated as Troublesome Creek in subbasin 03-06-01 of the Cape Fear River Basin in accordance with effluent limitations, monitoring requirements, and other conditions set forth in Parts I,II, III and IV hereof. This permit shall become effective This permit and authorization to discharge shall expire at midnight on April 30, 2026. Signed this day S. Daniel Smith, Director Division of Water Resources By Authority of the Environmental Management Commission Page 1 of 7 Permit NC0073571 SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES Permits issued to this facility,whether for operation or discharge are hereby revoked,and as of this issuance,any previously issued permit bearing this number is no longer effective.Therefore,the exclusive authority to operate and discharge from this facility arises under the permit conditions,requirements,terms,and provisions included herein. Dr. Mervyn R. King is hereby authorized to: 1. Continue to operate an existing 0.015 MGD w.'e. .te tment facility with the following components: ' • Bar screen • Aerated equalization tank ti • Aeration tank • Clarifier • Sludge holding tank • Sludge air lifts • Dual blowers • Tablet chlorination with chlorine contact basin • Tablet dechlorination unit • Ultrasonic flow meter • Rock step reaeration • Dual-feed power supply This facility is located near Stokesdale off U.S. Highway 158 at the Countryside Manor WWTP in Guilford County. 2. After receiving an Authorization to Construct from the Division, construct and operate a 0.03 MGD wastewater treatment facility. 3. Discharge from said treatment works via Outfall 001, at the location specified on the attached map into Troublesome Creek [16-6-(0.3)] currently classified WS-III; NSW waters in subbasin 03-06-01 [HUC: 030300020202] of the Cape Fear River Basin. Page 2 of 7 Permit NC0073571 Part I A. (1) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS (0.015 MGD) [15A NCAC 02B.0400 et seq., 15A NCAC 02B.0500 et seq.] Grade II Biological Water Pollution Control System [15A NCAC 08G .0306] Beginning with the permit effective date and lasting until expansion above 0.015 MGD, the Permittee is authorized to discharge treated domestic wastewater from Outfall 001. Such discharges shall be limited and monitored1 by the Permittee as specified below: EFFLUENT MONITORING REQUIREMENTS EFFLUENT CHARACTERISTICS LIMITATIONS Parameter Code Monthly Daily Measurement Sample Sample Average Maximum Frequency Type Location Flow 50050 0.015 MGD Weekly Instantaneous Influent or Effluent BOD,5-day,(20°C) C0310 30.0 mg/L 45.0 mg/L Weekly I Grab Effluent Total Suspended Solids C0530 30.0 mg/L 45.0 mg/L Weekly Grab Effluent NH3 as N—Summer* C0610 5.4 mg/L 27.0 mg/L Weekly Grab Effluent NH3 as N—Winter* C0610 10.8 mg/L 35.0 mg/L + Weekly Grab Effluent Dissolved Oxygen 00300 Daily average>5.0 mg/L Weekly Grab Effluent Fecal Coliform 31616 200/100 ml 400/100 ml Weekly Grab Effluent (geometric mean) Total Residual Chlorine3 50060 28 pg/L 2/Week Grab Effluent Temperature(°C) 00010 Daily Grab Effluent Total Nitrogen(NO2+NO3+TKN) C0600 Quarterly Grab Effluent Total Phosphorus C0655 2.0 mg/L Weekly Grab Effluent pH 00400 >6.0 and<9.0 standard units Weekly Grab Effluent Dissolved Oxygen 00300 Weekly Grab Upstream& Downstream 2 Fecal Coliform Upstream& (geometric mean) 31616 Weekly Grab Downstream 2 Temperature(°C) 00010 Weekly Grab Upstream& Downstream 2 *Summer: April 1 —October 31 *Winter.: November 1 —March 31 Footnotes: 1. The permittee shall submit discharge monitoring reports electronically using the NC DWR's eDMR system [see A.(3)]. 2. Upstream=at least 100 feet upstream from the outfall.Downstream=at NCSR 2103. 3. The Division shall consider all effluent TRC values reported below 50 µg/L to be in compliance with the permit. However,the Permittee shall continue to record and submit all values reported by a North Carolina certified laboratory (including field certified),even if these values fall below 50 µg/L. THERE SHALL BE NO DISCHARGE OF FLOATING SOLIDS OR VISIBLE FOAM IN OTHER THAN TRACE AMOUNTS. Page 3 of 7 Permit NC0073571 A. (2) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS (0.03 MGD) [15A NCAC 02B.0400 et seq., 15A NCAC 02B.0500 et seq.] Grade II Biological Water Pollution Control System [15A NCAC 08G .0306] During the period beginning after expansion above 0.015 MGD and submittal of a signed Engineering Certificate and lasting until expiration, the Permittee is authorized to discharge treated wastewater from Outfall 001. Such discharges shall be limited and monitored' by the Permittee as specified below: EFFLUENT MONITORING REQUIREMENTS EFFLUENT CHARACTERISTICS LIMITATIONS Parameter Code Monthly Daily Measuremen Sample Sample Average Maximum t Frequency Type Location Flow 50050 0.030 MGD Continuous Recording Influent or Effluent BOD,5-day,(20°C) C0310 30.0 mg/L 45.0 mg/L Weekly Composite Effluent Total Suspended Solids C0530 30.0 mg/L 45.0 mg/L Weekly Composite Effluent NH3 as N—Summer* C0610 3.2 mg/L 16.0 mg/L Weekly Composite Effluent NH3 as N—Winter* C0610 6.4 mg/L 32.0 mg/L Weekly Composite Effluent Dissolved Oxygen 00300 Daily average>5.0 mg/L Weekly Grab Effluent Fecal Coliform 31616 200/100 ml 400/100 ml Weekly Grab Effluent (geometric mean) Total Residual Chlorine 3 50060 28 pg/L 2/Week Grab Effluent Temperature(°C) 00010 Daily Grab Effluent Total Nitrogen(NO2+NO3+TKN) C0600 Quarterly Composite Effluent Total Phosphorus C0655 2.0 mg/L Weekly Composite Effluent pH 00400 >6.0 and<9.0 standard units Weekly Grab Effluent Dissolved Oxygen 00300 Weekly Grab Upstream& Downstream 2 Fecal Coliform Upstream& (geometric mean) 31616 Weekly Grab Downstream 2 Temperature(°C) 00010 Weekly Grab Upstream& Downstream 2 *Summer: April 1 —October 31 *Winter: November 1 —March 31 Footnotes: 1. The permittee shall submit discharge monitoring reports electronically using the NC DWR's eDMR system [see A.(3)1. 2. Upstream=at least 100 feet upstream from the outfall.Downstream=at NCSR 2103. 3. The Division shall consider all effluent TRC values reported below 50 µg/L to be in compliance with the permit. However,the Permittee shall continue to record and submit all values reported by a North Carolina certified laboratory (including field certified),even if these values fall below 50 µg/L. THERE SHALL BE NO DISCHARGE OF FLOATING SOLIDS OR VISIBLE FOAM IN OTHER THAN TRACE AMOUNTS. Page 4 of 7 Pei muit NC0073571 A. (3) ' ELECTRONIC REPORTING OF MONITORING REPORTS [NCGS 143-215.1 (b)] Federal regulations require electronic submittal of all discharge monitoring reports(DMRs)and program reports. The final NPDES Electronic Reporting Rule was adopted and became effective on December 21, 2015. NOTE: This special condition supplements or supersedes the following sections within Part II of this permit(Standard Conditions for NPDES Permits): • Section B. Signatory Requirements (11.) • Section D.(2.) Reporting • Section D. (6.) Records Retention • Section E. (5.) Monitoring Reports 1. Reporting Requirements [Supersedes Section D. (2.) and Section E. (5.) (all The permittee shall report discharge monitoring data electronically using the NC DWR's Electronic Discharge Monitoring Report(eDMR) internet application. Monitoring results obtained during the previous month(s) shall be summarized for each month and submitted electronically using eDMR. The eDMR system allows permitted facilities to enter monitoring data and submit DMRs electronically using the internet. The eDMR system may be accessed at: https://deq.nc.gov/about/divisions/water-resources/edmr. If a permittee is unable to use the eDMR system due to a demonstrated hardship or due to the facility being physically located in an area where less than 10 percent of the households have broadband access, then a temporary waiver from the NPDES electronic reporting requirements may be granted and discharge monitoring data may be submitted on paper DMR forms (MR 1, 1.1, 2, 3) or alternative forms approved by the Director. Duplicate signed copies shall be submitted to the following address: NC DEQ/Division of Water Resources/ Water Quality Permitting Section ATTENTION: Central Files 1617 Mail Service Center Raleigh,North Carolina 27699-1617 See"How to Request a Waiver from Electronic Reporting" section below. Regardless of the submission method, the first DMR is due on the last day of the month following the issuance of the permit or in the case of a new facility, on the last day of the month following the commencement of discharge. Starting on December 21, 2025, the permittee must electronically report the following compliance monitoring data and reports, when applicable: • Sewer Overflow/Bypass Event Reports; • Pretreatment Program Annual Reports;and • Clean Water Act(CWA) Section 316(b)Annual Reports. Page 5 of 7 Permit NC0073571 The permittee may seek an electronic reporting waiver from the Division (see "How to Request a Waiver from Electronic Reporting" section below). 2. Electronic Submissions In accordance with 40 CFR 122.41(l)(9), the permittee must identify the initial recipient at the time of each electronic submission. The permittee should use the EPA's website resources to identify the initial recipient for the electronic submission. Initial recipient of electronic NPDES information from NPDES-regulated facilities means the entity (EPA or the state authorized by EPA to implement the NPDES program)that is the designated entity for receiving electronic NPDES data[see 40 CFR 127.2(b)]. EPA plans to establish a website that will also link to the appropriate electronic reporting tool for each type of electronic submission and for each state. Instructions on how to access and use the appropriate electronic reporting tool will be available as well. Information on EPA's NPDES Electronic Reporting Rule is found at: https://www.federalregister.gov/documents/2015/10/22/2015- 24954/national-pollutant-discharge-el i m ination-system-npdes-electronic-reporting-rule Electronic submissions must start by the dates listed in the"Reporting Requirements"section above. 3. How to Request a Waiver from Electronic Reporting The permittee may seek a temporary electronic reporting waiver from the Division. To obtain an electronic reporting waiver, a permittee must first submit an electronic reporting waiver request to the Division. Requests for temporary electronic reporting waivers must be submitted in writing to the Division for written approval at least sixty (60) days prior to the date the facility would be required under this permit to begin submitting monitoring data and reports. The duration of a temporary waiver shall not exceed 5 years and shall thereupon expire. At such time, monitoring data and reports shall be submitted electronically to the Division unless the permittee re-applies for and is granted a new temporary electronic reporting waiver by the Division. Approved electronic reporting waivers are not transferrable. Only permittees with an approved reporting waiver request may submit monitoring data and reports on paper to the Division for the period that the approved reporting waiver request is effective. Information on eDMR and the application for a temporary electronic reporting waiver are found on the following web page: http://deq.nc.gov/about/d ivi lions/water-resources/edmr 4. Signatory Requirements [Supplements Section B. (11.) (b) and Supersedes Section B. (11.) (d)I All eDMRs submitted to the permit issuing authority shall be signed by a person described in Part II, Section B. (11.)(a) or by a duly authorized representative of that person as described in Part II, Section B. (11.)(b). A person, and not a position, must be delegated signatory authority for eDMR reporting purposes. For eDMR submissions, the person signing and submitting the DMR must obtain an eDMR user account and login credentials to access the eDMR system. For more information on North Carolina's eDMR system, registering for eDMR and obtaining an eDMR user account, please visit the following web page: http://deq.nc.gov/about/divisions/water-resources/edmr Page 6 of 7 Permit NC0073571 Certification. Any person submitting an electronic DMR using the state's eDMR system shall make the following certification [40 CFR 122.22]. NO OTHER STATEMENTS OF CERTIFICATION WILL BE ACCEPTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 5. Records Retention ISunnlements Section D. (6.)1 The permittee shall retain records of all Discharge Monitoring Reports, including eDMR submissions. These records or copies shall be maintained for a period of at least 3 years from the date of the report. This period may be extended by request of the Director at any time [40 CFR 122.41]. Page 7 of 7 `hem ' 'r.n v r j Jf ' I/ } {._- - aa.r _=\ ( -. Tt 9 , • 0.. iv(i ' - �� _' r 1+1GI C-�� .�o ,- / 3 . ' •- - 1, ' ) LY-` i r-- \-/-- ) \ \ ; \\ ( , \ ( - --- 1 / . --*---1 ! . II �-q6� ` J \ Ocb '/ •• ' us's(' il 'Iv' .,1' - "IP-A Atfilirt --1 - ,,r Allell_ 11,.tirip- .. . " I. 11111.____ Alt,./111tikl '''').. \_„..--,4,.. �� „ Outfall 001 ;ilk , . Att.„,--41101 Aii--__ii- Atali,4wi,„jr ,,ii . 9cp r.. „--- -__,- , .4. „,,A..4., .. , __- __,—,_ ,3-1.-----------) _:- ,----__....,,c- , , kvvierj, 4,1$114_,,„,..„*„:„ . ‘-"wr44, -_,, , ' .. f ) nci7L f 4rW.4.... / �r \__ US 158 goo 930 \„1 �� it Irgr—- 7~p*.'‘;,S. ti ----.:4.,,,,4 t xma") . ej, __\______________j tivet .:19b- ...too-4--.!%..-4 -.4:::‘,;, IVA-- ---;----,i_,>,..:_,Er iliCa.' ,...ig L._ illijii • ‘ ,0514"--- •.. p 4 rer..._____ ,.., . ..7,_ ___ ,a„____ _ _____,_____..,„........._ . .,...., ____ ,/ .. _,._ ---;--- --77a---1.11#* •,..1 0 1 NP g ---'," 1111111w ______.,_ NOP .4 CI ''''''4 . 4,, .: 0 i,_ _ . !� a -, 0 .0244--"N I_ „,,,/, .... ��I N,,. ,‘ .0 ....v..):00 4 s. .:-----*-- --,.. -41. . ....41A' s:-''3 , , ..,f0.5 /111 Nit. ..4), -----"---:".- Mervyn R. King N A !"�r1•01 1�1- Countryside Manor WWTP i41*h� AMit r/r i NPDES Permit NC0073571 "-Avil li{raj- #41" Facility Location iikaj �16� Receiving Stream:Troublesome Creek Stream Class:WS-Ill; NSW scale not shown # Stream Segment: 16-6-(0.3) Sub-Basin#:03-06-01 ��� River Basin:Cape Fear HUC:0303000202 SCALE 36.244722°, -79.958333e County:Guilford 1:20,000 USGS Quad:Summerfield