Loading...
HomeMy WebLinkAboutSW6201202_O&M Agreement_20210507Project Name: Project Location: Faithwill Farms Subdivision Stedman, Cumberland County, North Carolina Cover Page Maintenance records shall be kept on the following BMP(s). This maintenance record shall be kept in a log in a known set location. Any deficient BMP elements noted in the inspection will be corrected, repaired, or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, and the pollutant removal efficiency of the BMP(s). i The BMP(s) on this project include (check all that apply & cc Bioretention Cell Quantity: Dry Detention Basin Quantity: Grassed Swale Quantity: Green Roof Quantity: Infiltration Basin Quantity: Infiltration Trench Quantity: Level Spreader/VFS Quantity: Permeable Pavement Quantity: Proprietary System Quantity: Rainwater Harvesting Quantity: Sand Filter Quantity: Stormwater Wetland Quantity: Wet Detention Basin Quantity: Disconnected Impervious Area Present: User Defined BMP Present: onding O&M tables wil Location(s): Location(s): 2 Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Locations) Locations) Location(s) 0 Location(s) No Location(s) No Location(s) I be added automatically): West Side of Wade -Stedman Rd I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed for each BMP above, and attached O&M tables. I agree to notify NCDENR of any problems with the system or prior to any changes to the system or responsible party. * Responsible Party - Title & Organization: Street address: City, state, zip: Phone number(s): Email: Ben Stout Registered Agent - Stout Land Development, LLC 409 Chicago Drive - Suite 103 Fayetteville, NC 28306 910-779-0019 ben@benstoutconstruction.com Signature: )AKK Date: I t1 , a Notary Public for the State of Noah G Q rn�i�nc� County of W Y1 o Q,�(l Cld do hearby certify that personally appeared before me this day of _ Y 1 2b and jjjjjj1Ir►rr acknowledge tlZp1'�l.(,e �cUW,,6 gf;he Operations and Maintenance Agreement . Witness mZrh ttd fifF81al-§ s . AR t -nG P h P :IPrrI20 FR�ANO Mu nnmmiccinn nYnirac 4/6/2( Grassed Swale Maintenance Requirements Important maintenance procedures: The drainage area of the grassed swale will be carefully managed to reduce the sediment load to the grassed swale. _ After the first-time fertilization to establish the grass in the swale, fertilizer will not be applied to the grassed swale. The grassed swale will be inspected once a quarter. Records of operation and maintenance will be kept in a known set location and will be available upon request. Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately. BMP element: Potential problem: How to remediate the problem: The perimeter of the BMP Areas of bare soil and/or Regrade the soil if necessary to remove the gully, and then plant a erosive gullies have formed. ground cover and water until it is established. Provide lime and a one- time fertilizer application. Vegetation is too short or too Maintain vegetation at a height of approximately six inches. long. The entire length of the Trash/debris is present. Remove the trash/debris. Areas of bare soil and/or Regrade the soil if necessary to remove the gully, and then re -sod (or swale erosive gullies have formed. plant with other appropriate species) and water until established. Provide lime and a one-time fertilizer application. Sediment covers the grass at Remove sediment and dispose in an area that will not impact streams the bottom of the swale. or BMPs. Re -sod if necessary. Vegetation is too short or too Maintain vegetation at a height of approximately six inches. long. The outlet device Clogging has occurred. Clean out the outlet device. Dispose of the sediment off -site. The outlet device is damaged Repair or replace the outlet device. The receiving water Erosion or other signs of Contact the local NC Department of Environment and Natural damage have occurred at the Resources Regional Office. outlet. ORM-EZ 4/6/2l