Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0032913_Regional Office Historical File Pre 2018
Michael Eirsley, Governor Witham G. Ross Jr., Steretary North Carolina pirlmnr F nvironate.nt and 'Natural Re.suurces Coleen El. Dave:tor Division of Water Quality' April 19, 2008 Mr. Billy Price, Director of Public Works Town of Maiden 113 West Main Street Maiden, NC 28650 Subject: Permit No, WQ0032913 Cansler Circle Wastewater Collection System Extension Catawba County, North Carolina Dear Mr, Price, In accordance with your application received on April 8, 2008, we are forwarding herewith Permit No. WQ0032913, dated April 18, 2008, to the Town of Maiden for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee, Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215,6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite .301 Mooresv NC 28115 Phone. r 704) 663-1699 Fax: (704) 66'3-61)40 Internet www,ncruwaterquality_org Customer Service: 1-877-623-6748 An Equal OpporlunitylAffirmat1ve Action Employer - 510°/6 Recyctedl10% Post Consumer Paper Northcarolii. Aaturally Mr. Price Page2 'April 18, 2008 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Town of Maiden for the construction and operation of approximately 284 linear feet of 8- inch gravity sewer and the discharge of 6,000 gallons per day of collected domestic wastewater into the Town of Maiden existing sewerage system, pursuant to the application received April 8, 2008, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit The sewage and wastewater collected by this system shall be treated in the Town of Maiden VVVVTP (NPDES No. NC0039594) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit, This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714, Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. SinereIy, r Coleen H. Sullins cc; Mooresville Regional Office, Collection System Permit File Scott Bell, Hayes, Seay, Mattern, &Mattern (HSMM) Surface VVater Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1, This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T ,0401 a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L ,0200 or the surface water standards in 15A NCAC 2B .0200, b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented, d Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215,1C. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6, Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A cornplete certification is one where the form is fully executed and the supporting documents are provided as applicable 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities, 8. Failure to abide by the conditions and I mitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9 In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities, 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc., or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report, Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300, Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence, This report shall outline the actions taken or proposed to ensure that the problem does not recur i Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control, Permit issued this the 19th day of Apni, 2008, NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen Hi Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0032913 ' Fast.Track Engineering Certification Permit No. WQ0032913 ' April 18, 2008 OwnerNVQCSNWVIP PE Billy Price, Dir, Of PW Scott Bell Town of Maiden Hayes, Seay, Mattern, & Mattern (HSMM) 113 West main Street 1305 N. Center Street Maiden, NC 28650 Hickory, NC 28601 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minirnum_design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (E] periodically, El weekly, 1] full time) the construction of Cansler Circle, a Catawba County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump ; Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials, North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. USE THE TAB KEY TO MOVE. FROM FIELD TO F 1.. OwnerlPermitte la. Town of Maiden Full Legal Name (company, Application Number: (to be completed by DWQ) unicipality, HOA, utility, etc.) 1 b. Billy Price, Director of Public Works Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) or authorized signing officials lc. The legal entity who will own this system is: ❑ Individual ❑ Federal Municipality ❑ State/County 0 Private Partnership ❑ Corporati ld, 113 West Main Street Mailing Address z z 1 f'. NC State 1 h. (828) 428-5006 Telephone Facsimile 2. Project (Facility) Information: 2a, Cansler Circle Water and Sewer Improvements Brief Project Name (permit will refer to this name) 3. Contact Person: 3a, Scott Bell, Consultant 1 e. Maiden City 1 g. 28650,..... Zip Code 1j, bprice a@mail. E-mail 2b. Catawba 0 Other (spe maiden.nc.us County Where Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (828) 327-2971 Phone Number 3c. sbei)lhsmmcom E-mail 1. Project is New 0 Modification (of an existing permit) If Modification, Permit No.: 2. Owner is Public (skip to Item 8(3)) 2a, If private, applicant will be: ❑ Private (go to Item 2(a)) 2b. If sold, faci 0 Retaining Ownership (i.e. store, church, single office, etc) or 0 Leasing units (lots, townhomes, etc, - skip to item B(3)) ❑ Selling units (lots, townhomes, etc, - go to Item B(26)) 3. Town of Maiden Owner of Wastewater Treatment Facility (WWTF) Treating 4a. Maiden WWTP Name of WWTF 5a. Town of Maiden 15b. Owner of Downstream Sewer 'Receiving Sewer Size The origin of this wastewater is (check all that apply): ❑ Residential Subdivision Apartments/Condominiums ❑ Mobile Home Park 0 School ❑ Restaurant ❑ Office owned by a (must choose one) Public Utility (Instruction C) Homeowner Assoc.IDeveloper (Instruction D) astewater From This Project 4b, NC 0039594 Gravity Force Main 0 Retail (Stores 0 Institution ❑ Hospital ❑' Church ❑ Nursing Home Other (specify): Industrial WWTF Permit No. Permit # of Downstrea hopping centers) Sewer (Instruction E) 100 % Domestic/Commercial % Industrial (attach description) (RO: contact your Regional Office Pretreatment staff) % Other (specify): Volume of wastewater to be allocated or permitted for this particular project: 6,i1f30 gallons per day *Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why: O Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No, O Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FT.A 1:?r`ti7 ver2 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). 25 gal/shift/person x 2 shifts/day x 120 persons --r- 6,000 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8 1487 New Gravity or Additional Force Main Gravity 6 11. Summary of Pump Stations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) W Pump Station Location ID (self chosen - as shown on planslmap for reference) Z Design Flow Operational Point Power Reliability Option Z (MGD) GPM @TDH 1 - permanent generator w/ATS; Force Main Size Force Main Length 0 2 - portable generator w/MTS 0 0 Pump Station Location ID (self chosen - as shown on plans/map for reference) 2 Design Flow Power Reliability Option IX (MGD) Operational Point 1 _ permanent generator w/ATS; Force Main Size Force Main Length 0 GPM @TDH 2 - portable generator w/MTS LL Z re Pump Station Location ID (self chosen - as shown on plans/map for reference) LU 0. Design Flow Operational Point 1 _ Power Reliability Option (MGD) permanent generator w/ATS; Force Main Size Force Main Length ai GPM @TDH 2 - portable generator w/MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directedthrected to another treatment facility? Yes No If Yes, permit number of 2nd treatment facility (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? Yes LI No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA12/07_ver2 14, Have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401Certification? E] Yes E No N/A Sedimentation and Erosion Control Plan? El Yes Ei No N/A Stormwater? E Yes El No N/A 15. Does this project include any high priority lines, [see 15A NCAC 02T ,0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: El and provide details 1. Owner/Permittee's Certification: (Signature of Signing Official and Project Name) • 1, Billy Price, Director of Public Works attest that this application for The Town of Maiden, Sewer Infrastructure Improvements has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete, Note: In accordance with North Carolina General Statutes -215.6A and 143-215.68, any person who knowingly makes any false statement, representation, Ica any application shall be guilty of a Class 2 misdemeanor, which may include a tine not to,e1Ce d civil penalties up to $25,000 per violation. ,/ Signing Ocia Sigriature e Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY u) TO OTHER UTILITIES, DESIGN CALCULATIONS ETC, REFER TO 15A NCAC 02T .0305 0 2, Professional Engineer's Certification: (Signature of Design Engineer and Project Name) /, P. Scott Bell _ attest that this application for The Town of Maiden Sewer Infrastructure Improvements has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Mr, P. Scott Bell Professional Engineer Name 2b. Hayes, Seay, Mattern, & Engineering Firm 2c. 1305 N. Center Street Mailing Address 2d, Hickory 2e. NC 2f 28601 City State Zip 2g. 828-327-2971 2h, 828-327-4958 2i. sbell@hsrnm.com Telephone Facsimile E-mail NC PE Seal, Signature & Date FTA 2107_ver2 State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE —10/07) Project Applicant Name: Town of Maiden Project Name for which flow is being requested: Town of Maiden Sewer Lnfrastructure Improvements More than one FTSE-10/07 may be required for a single projec pump stations along the route of the proposed wastewater flow. e owner ofthe WWTP is not responsible lb,- all I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Maiden Wastewater Treatment Plant b. WWTP Facility Permit #: NC 0039594 All flows are in MGD c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated -flows to the facility h. Percent of permitted flow used, II.. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity, MGD Approx. Current Avg. (Firm/Design) Daily Flow, MGD . Certification Statement:. I, Billy Price, Director of Public Works_ certify that, to the hest of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the :route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances„ This analysis has been performed in accordance with local established policies and procedures using the best avaiJb1e dataThis certification applies to those items listed above in Sections 1 and 11 f 1ch 1 41 th4e4bnsih1e party, Signature of this form indicates acceptance of this wastewater flo 0.O0"W ; 081' 14' 30.00' Wtil Name: REEPSVILLE Date: 3/24/2008 Scale: 1 inch equals 1000 feet Map# N3530-W8115f7.5 Location: 035° 35' 55.22" N 081 m '15' 05.83" W Caption: Gensler Circle Sewer Improvements Copyrught CC) 1998, Maptech, Inc. Transmittal Sheet HSMM 1305 North Center Street, Hickory, North Carolina 28601 T 828.327 2971 F 828 327.4958 To: NCDENR Division of Water Quality Mooresville Regional Office 610 E. Center Avenue Mooresville, NC 28115 Date April 7, 2008 RE: Cansler Circle Water and Sewer Improvements Project No. 61065 Phase: We are sending you 2 copies of the following enumerated LlPrints ElSepias LlShop Drawing ESamples IIIBrochures LJCat, Cuts fl ,]Letters ElSpecifications 'cation for Sewers Check #1110 for $480,00 Fast Track A Our Comment: Please let me know if you have any questions. Distribution 1 2. 3 4 5, Transmitted By [-Nail CUPS 0 R'otection For Your ElAction [JCorrections ['General Information DRequest ['Resubmission El HSMM Signature S Name Scott Bell Title Project Manager adrrurst 3 (rev O537 Con i Files: BPS SWP 04/17/08 Permit Number 0032913 Perm t Track ng Shp Program Category Nor Permit Type Gravity Sewer E Extensions Primary '^ calcite de. broredr Permitted Flom 6000 Facility .t Track Status Active Project Type New Project Version Permit CI ssifleati n �, Pump Stations, Pressure Sewsr 1,00 individual Permit Contact Affiliation —Facility Name Majorl` inor Region Cansler Circle Water and Sewer Ira ye rneras Minor Mooresville Location Addre Owner County Catawba Fag" ity Contact Affill do Owner Name Town of Maiden Date /Event rnp Issue Apo Received Draft India Sod 17/08 04/08r08 .Re Waited a otivlti s industrial,'orarerc°irtB,,vrisrav ales N8ste.WatOr tolls tra r tal NUM Waterbody Name Scheduled d Issuance d Owner Type Government m tylttniolpal Owner Affiliation Todd Clark, Manager Towvn POBox 12 Maiden NC 28650 Public Notice Issue Effective 04 17/0 0 1171t 8 ve v n ddilicnrai lMon raatiora requested Additmcai iraforrrgatior received lurnbc r Expiration Current Class Sut hasrn ARCHITECTS ENGINEERS PLANNERS 1305 N CENTER STREET HICKORY, NC 2B603 800-568-7986 TOLL FREE PAY TO THE ORDER OF 0 Banc, N.A. EN` k' FOR it 6/0 HSMM 111© 66-1621531 BRANCH 58CK,2 DATE 20000 19755E16Si DOLLARS Michael F. Easley, Governor VWilliam G Ross Jr., Secretary North Carolina t3epaen t of Environment and Natural Resources Coleen Sullins, Director Division of Water Quality Town of Maiden 113 West Main Street Maiden, North Carolina 28650 Attn: Billy Price, Dir. of Public Works SUBJECT: Cansier Circle Sewer Improvements Permit No, WQ0032913 Wastewater Collection System Extension Final Engineering Certificafion Dear Permit The Division received a final engineering certification for the subject project on July 15, 2008. A full review of the certification materials may or may not be conducted, It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. if you have not received a copy, please contact your consultant immediately to obtain a copy. You are receiving this letter because the Division has you Misted as the responsible party. if this permitted system is no longer owned by you, please complete Form PNQCF-S as this permit is not automatically transferable. Form PN OCF-S can be downloaded from httplyh2o.enr.state.nc usndpuL. dpugpp s htmlirSevv r, If you have any questions concerning this document or the completion of Form PNOCF-S cif necessary), please contact Ms, Dee Browder at the letterhead address or via E-mail at dee,browder@ncmaiLnet. Sincerely, li1.'� obert Krebs ace Water Protection Regional Supervisor Enc..losure cc. Stoll Bell, Hcyes,,Seay, Mattern t?x Mattern Surface Water Protection SecJon Central Files lcerlk o°lion page only) One. North Pretreatment, Emergency Response and Collection Systems Unit Internet http llh2o.enr.nc.sfate.us°ndpu 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal opportunity Action Employer Telephone (919) 733-5063 Fax (919) 733-0059 50% recycled/10% post -consumer paper rack Engineering ertification it No WQ0032913 pril 18, 2008 Owner/WQCS P Billy Price, Dr Of PW Town of Maiden 113 West main Street Maiden, NC 28650 PE Scott Bell Hayes, Seay, Mattern, & Mattern (H 1305 N. Center Street Hickory, NC 28601 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required for any changes resulting in non-compliance with this permitre ulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and ail required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division, iR Se..irh` -goe-tt ENGINEER'S CERTIFICATION LI Partial Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe periodically, E weekly, full time) the construction of Cansier Circle, a Catawba County project for the Permittee, ereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions Transmittal Sheet HSMM 1305 North Center Street, Hickory, North Carolina 28601 7 828.327,2971 F 828 327,4958 To: Mooresville Regional Office Surface Water Protection 610 East Center Avenue Suite 301 Mooresville, NC 28115 Date July 14, 2008 RE: Cansler Cir e Sewer Improvements Project No. 61065 Phase: We are sending you 1 copies of the following enumerated ElPrints LiSepias EiShop Drawing [T]Samples DBrochures EICat, Cuts E Drawings (#G0001, G0002, C(J101, CU1O2, CU103, CU5O1) Engineer's Certification Our Comment: Please contact me wtth any comments. Distribution 1 2. 3 4 ElLetters "'Specifications :rofecffofl For Your DAction DCorrections E General Information EiRequest LjResubmission LI HSMM Transmitted By LiMail Signature E UPS Name P. Scott Bell Li Title Project Manager adm_Irs 13 (rev. 05/07)