HomeMy WebLinkAboutWQ0016612_Application (FTSE)_19990323MEMO TO: State Review Grouu Division of Water Quality FROM: Ricky Revels f7 Fayetteville Regional Office SUBJECT: Procedure Four (4) March 26. 1999 WQ0016612 Date Campbell University Apartment Site Sewer Extension -Private Campbell University Harnett County State Review Group Review Engineer Danny Wiegand Regional Office Contact Ricky Revels 1) Name of wastewater treatment plant to receive the wastewater: Harnett Co.s Buies Creek WWTP 2) WWTP design capacity 0.5000 MGD 3) NPDES Permit No. NC0030091 Expiration Date: 03/31/2001 4) Compliance Information: Present treatment plant performance for previous 12 months, beginning 1/98-12/98 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: *64.800 GPD domestic X industrial other 6) Volume from previously approved projects not yet tributary to WWTP: -24,000- GPD 7) Regional Recommendations: Approval *X Denial * It is understood that 80/90% letters should go out from Raleigh around June 1999. RR/rr Enclosure • GKEX88/MP COMPLIANCE EVALUATION ANALYSIS REPORT 03/26/1999 PAGE 1 PERMIT--NC0030091 PIPE--001 FACILITY--BUIES CREEK WWTP LOCATION--BUIES CREEK REPORT PERIOD: 9801-9812 LOC---E DESIGN FLOW-- .5000 CLASS--2 REGION/COUNTY--06 HARNETT 50050 00310 00530 00610 31616 50060 TGE6C MONTH Q/MGD BOD RES/TSS NH3+NH4- FEC COLI CHLORINE FTHD24PF LIMIT F .5000 F 98/01 .5202F 98/02 .5455F 98/03 .6101F 98/04 .4981 98/05 .3150 98/06 .2817 98/07 .2706 98/08 .2926 98/09 .4034 98/10 .3932 98/11 .3922 LIMIT NOL 98/12 .3455 AVERAGE MAXIMUM MINIMUM UNIT 30.00 F 30.0 24.34 20.7 7.59 11.8 3.92 13.85 12.4 2.91 11.26 6.9 5.13 10.07 5.5 2.11 13.38 9.4 2.69 15.43 12.7 14.22 11.80 7.3 1.74 6.52 9.9 6.60 4.28 6.9 3.97 13.92 16.5 2.70 NOL NOL NOL 17.32 19.6 2.38 .4056 12.48 1.1888 67.00 .1387 LESSTHAN MGD MG/L 11.6 58.0 2.0 MG/L 00010 TEMP NOL F 200.0 NOL NOL NOL 7.74 3.6 277.419 1 14.22 1.2 270.833 13.66 2.4 178.571 14.92 2.8 183.076 1 18.61 28.4 283.333 20.66 3.6 257.142 24.00 13.6 307.692 1 26.53 1.6 376.923 26.69 5.9 307.142 25.71 5.0 383.333 22.75 2.6 416.666 18.91 NOL NOL NOL NOL 2.0 625.000 17.06 4.67 6.0 322.260 1 20.31 19.00 112000.0 1000.000 1 28.00 .20 LESSTHAN 100.000 1 12.00 MG/L #/100ML UG/L PASS/FAI DEG.0 GKEX88/MP COMPLIANCE EVALUATION ANALYSIS REPORT 03/26/1999 PAGE 2 PERMIT--NC0030091 PIPE--001 FACILITY--BUIES CREEK WWTP LOCATION--BUIES CREEK 00400 00600 00665 MONTH PH TOTAL N PHOS-TOT LIMIT 9.0 6.0 NOL NOL 98/01 6.9-6.5 31.660 1.1300 98/02 6.9-6.6 98/03 6.9-6.7 98/04 6.9-6.1 13.470 1.5400 98/05 6.9-6.5 98/06 7.0-6.6 98/07 7.1-6.7 14.400 2.3600 98/08 6.9-6.6 98/09 7.1-6.6 98/10 7.1-6.7 98/11 7.1-6.5 LIMIT NOL NOL NOL 98/12 7.6-6.7 AVERAGE 19.843 1.6766 MAXIMUM 7.680 31.660 2.3600 MINIMUM 6.100 13.470 1.1300 UNIT SU MG/L MG/L REPORT PERIOD: 9801-9812 LOC---E DESIGN FLOW-- .5000 CLASS--2 REGION/COUNTY--06 HARNETT • State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary Kerr T. Stevens, Director March 23, 1999 Dr. James H. Ellerbe Campbell University Post Office Box 535 Buies Creek, North Carolina 27506 Dear Dr. Ellerbe: AVA NCDENR NORTH CAROLINA DE dIE jilt/ % ENVIRONMENT AND NATU ROES., MAR 2 5 1999 FAYETTEVI LLE REG. OFFICE Subject: Application No. WQ0016612 Campbell University Apartment Site Sewer -Private Harnett County The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on March 17, 1999. This application has been assigned the number listed above. Your project has been assigned to Mr. Danny Wiegand for a detailed engineering review. Should there be any questions concerning your project, the review will contact you with a request for additional information. Be aware that the Division's Regional Office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the division. If you have any questions, please contact Mr. Danny Wiegand at 919/733-5083 ext. 358. If the engineer is unavailable, you may leave a message on their voice mail and they will respond promptly. PLEASE REFER TO THE ABOVE APPLICATION NUMBER WHEN MAKING INQUIRES ON THIS PROJECT. cc:Fayetteville Regional Office, Water Quality Parker & Associates, Inc. P.O. Box 29535, Raleigh, North Carolina 27626-0535 An Equal Opportunity Affirmative Action Employer Sincerely, `.--Mr. Kim H. ColsorfeP.E. Supervisor, Non -Discharge Permitting Unit Telephone 919-733-7015 FAX 919-733-2496 50% recycled/ 10% post -consumer paper RECEIVED WATER QUALITY SECTION MAR 1 71999 Non -Discharge Permitting State of North Carolina Department of Environment, Health, and Natural Resources Division of Environmental Management Non -Discharge Permit Application (THIS FORM MAYBE PHOTOCOPIED FOR USE AS AN ORIGINAL) GRAVITY SEWER EXTENSION PUMP STATIONS, AND PRESSURE SEWERS I. GENERAL INFORMATION: 1. Applicant (corporation, individual, or other ): Campbell University 2. Print Owners or Signing Official's Name and Title (the person who is legally responsible for the facility and its compliance): Dr. James H. Ellerbe (Secretary) 3. Mailing. Address: P.O. Box 535. 501 Dr. McKay Road City: Buies Creek State: NC Zip: 27506 Telephone No.: (910 ) 893-1610 4. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans/specs., letters of flow acceptance, Operational Agreements, etc.): Campbell University Apartment Site 5. Application Date: 3/12/99 7. County where project is located: II. PERMIT INFORMATION: 1. Permit No. (will be completed by DEM): Lk. QJ'(0(0 la 2. Specify whether project is: X new; renewal*; modification. *If renewal, complete only sections I through III and applicant signature (on pg.9). Submit only pgs. 1, 2, 9 (original and 3 copies of each). Engineer signature not required for renewal. N/A 3. If this application is being submitted as a result of a renewal or modification to an existing permit, list the existing permit number and issue date 4. Specify whether the applicant is public or X private. 6. Fec Submitted: $ 400.00 Barnett County revolkR.• ncnc Ain, GRAVITY SEWER EXTENSION & PUMP STATION PAGE 2 (4/91) III. INFORMATION ON WASTEWATER: 1. Nature of Wastewater: 100 % Domestic; % Commercial; Industrial; % Other waste (specify): 2. Please provide a one or two word description specifying the origin of the wastewater, such as school, subdivision, hospital, commercial, industrial, apartments, etc.: Apartments 3. Indicate any parameter (and its concentration) that will be greater than normal domestic levels: None Known 4. If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving wastewater treatment facility? N/A 5. Volume of wastewater generated by this project: 64,800 gallons per day 6. Explanation of how wastewater volume was determined: (9) Buildings x (8) Units x (3)Brms. x (120) GPD x 2.5 = 64,800 GPD Bldg. Unit Brms IV. DESIGN INFORMATION: 1. Brief project description: Private gravity collection sewer services for (9) proposed Apt. buildings and (1) on -site lift station and off site force main delivering to ex. private gravity sewer system. 2. Name of wastewater treatment facility receiving wastewater. Buis Creek WWTF a. Facility permit no.: NC 00 300 91 b. Engineer should provide statement of his evaluation of downstream sewers to accept the wastewater: Ex. downstream gravity sewer main flows dirctly to Bilks Creek WWTF presently operating at approx. 400,000 GPD with max. capacity of 500,000 GPD. Contact Mr. Jay Michaels ORC at 910-893-4252 for more information regarding 17-mq:clad future upgrade. N/A N/A GRAVITY SEWER EXTENSION & PUMP STATION PAGE 3 (4/91) 3. Summary of sewer pipe by diameter size and pipe material. Indicate here whether C factor or N factor is used and circle C or N below: Dia. Length Pipe C or N Min. Max. Minimum Max. Minimum (In.) (Lin. Ft) Material Factor Slope % Slope % Velocity (fps) Vel.(fps) Cover (in) NOTE: The minimum velocity must not be less than 2 fps. For public sewers the minimum diameter is 8 inches. 4. Anchors shall be provided for sewers with slopes greater than 20 %. The anchor spacing shall be as follows: a. 36 feet separation for slopes of 21% to 35%; b. 24 feet separation for slopes of 36% to 50%; c. 16 feet separation for slopes of 50% and greater. For velocities greater than 15 fps, it is strongly recommended that measures be considered which will protect the sewers and manholes from erosion. For velocities greater than 20 fps, erosion control measures must be specified. For any excessive slopes or velocities that will occur in any sewer line segment, what measures have been taken to protect the sewer pipe and manholes? N/A 5. Maximum sewer reach length between manholes: linear feet. N/A 6. This sewer line segment occurs between manhole no. and manhole no. N/A 7. Does the owner/operator have the ability to clean this length? Yes No. N/A 8. Sewer subject to existing or planned traffic bearing loads? Yes No. If yes, what measures are being taken to enable the sewers to withstand the loads? N/A 9. Outside drop manholes are provided where invert separations exceed: feet. N/A 10. Identify (by manhole number) those manholes that have drop connections: 3 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 4 (4/91) 11. Maximum allowable infiltration/exfiltration test rate: Note: Must not exceed 200 GPD/ pipe dia. in./ mile. 12. Minimum separation distances as shown on the plans or addressed in the specifications: a) 100 ft. horizontal separation from wells or other water supplies? X Yes _ No 00 GPD/ pipe dia. in./ mile. b) 12 in. vertical separation from storm sewer or ferrous pipe sanitary sewer specified? X Yes _ No c) 10 ft. horizontal separation from water mains or 18 in. vertical separation (water over sewer) or ferrous pipe specified? X' Yes ,_ No N/A 13. Are manholes subject to flooding? _Yes No N/A 14. If yes, are manhole rim elevations 1 foot above 100-year flood level, _ Yes _ No (100 yearflood elevation should be indicated on plans) N/A 15. Or are manholes watertight and vented 1 foot above the 100-year flood elevation ( shou::1 be shown on plans): _Yes _ No N/A 16. Identify (by manhole number) those manholes that are vented: 17. Does this project involve any stream crossings? _ yes X no. If yes, what precautions or special features have been utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station number where stream crossings are located: 4 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGES of 10 (4/91) V. PUMP STATION INFORMATION 1. Pump Station No.: 1 (A separate sheet V.1 through V.15 should be submitted for each pump station) 2. Name of closest downslope surface waters: East Buies Creek 3. Classification of closest downslope surface waters: WS-4 (as established by the Environmental Management Commission & specified on page 6 of this applic.). 4. If a power failure at this pump station could impact waters classified as WS, SA, B, or SB, describe which of the measures are being implemented to prevent such impact, as required in 15A NCAC 2H .0200: Back-up power supply/portatie generator 5. What size pumps are provided? 68 GPM 6. How many pumps are provided? 2 7. What is the maximum capacity of the pump station? 72,000 GPD 8. What is the design total dynamic head? 59 feet 9. How many pumping cycles will occur at the design flow rate? 10. Check if provided at pump station: Alternate Power Source x Wet Well Vented with Screen Fillets in Wet Well Check Valves and Gate Valves Security Fencing Lockable Wet Well Cover Area Light 110V Electrical Convenience Outlet Flood/Buoyancy Protection x High Water Alarm x Audible and Visual x Auto Dialer 11. Summary of force main (by diameter size and pipe material): Diameter Length Pipe High Low Minimum Maximum Minimum (Inches) (Linear Ft) Material Elevation Elevation Velocity(fps) Vel.(fps) Cover (in) 2.5 938 PVC 183.8 168.8 2 8 48 5 x x x x x x cycles per hour x 12. Are air release valves provided at all high points along the force main (must be provided where the elevation difference exceeds 10 feet)? x yes — no 13. Is pump station subject to flooding? yes x no. If yes, what measures are being taken to protect against flooding? N/A 14. If subject to flooding, specify the 100-year flood elevation: Feet MSL 15. Are there existing or planned pump stations downstream of this station? _ yes x no If yes, the engineer shall evaluate the ability of those pump stations to adequately handle the subiect flnwc. MRR.10.1999 1 37PMry�•�� NV I RO • ENAL _n.a.. ES • 636 Po2.03l 6.2/29 17:47 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 6 (4/91) TO: REGIONAL WATER QUALITY SUPERVISOR Please provide me with the classification of the surface waters identified in number 5 heir and on the attached map segment: 'Name of surface waters: Fos / 8 i t S Crc J C laasifcadon (as established by the Environmenal Management Commission): WS —IC Proposed Classification, if applicable: _.._ NA Signature of regional oftiee personnel: /9//RL4-- Date: S- /0- 9 / INSTRUCTIONS TO ENGINEER In order to determine whether provisions for dual or standby power may be required for the subject facility. the classificadon of the closest downslope surface waters (the surface waters that any overflow from the facility would flow toward) must be determined You are required to submit this form,, with items 1 through 10 completed, to the to Division of Envrtonnumtal t Regional Water Quality Supe visor (nee attach f g). At a tninizaum, you must iacl an SS" by 11" copy of the portion of a 7S minute USOSS Topographic Map which shows the ce ce You must identity the location of die facility and the closest downslope The application may not be submitted undl thisform is ctheomp d)it eluded with the innittedubbmitt 1. 1. Applicant (corporation, individual, or other ): Clucball tmivorsity 2. Name and Complete Address of Engineering Firm: Parker a Aseeciates P.O. Box 58475 nrazc: "a tip: Z7030 Telephone No. (919) 876-7778 taffies) ,(919) 876-6678 (fan) 3. Project Nantes _Caspbeu t)nivexiity iiiment site 4. Pump nation design flow: 64, 800 dam; 45 S. Name of closest downslope surface waters: _ _team cosh 6. County(s) where project and surface waters are located: Earnett Canty 7. Map name and date: cents. t - 1973 rev. 1987 8. North Carolina Professional Engineer's Registration No. 24643 9. Print Name of Engineer Dion J. viventi., P.E. GPM 10. Seal and Signature (specify date): ` 0 CM • 40, ,,` 6of10 DIVISION OF ENVIRONMENTAL MANAGEMENT REGIONAL OFFICES (4/91) Asheville Regional WQ Super. 59 Woodfin Place Asheville, NC 28802 704/251-6208 Avery Buncombe Burke Caldwell Cherokee Clay Graham Haywood Henderson Jackson Macon Madison McDowell Mitchell Polk Rutherford Swain Transylvania Yancy Fayetteville Regional WQ Super. Wachovia Building, Suite 714 Fayetteville, NC 28301 919/486-1541 Anson Moore Bladen Robeson Cumberland Richmond Harnett Sampson Hoke Scotland Montgomery Winston-Salem Regional WQ Super. 8025 North Point Boulevard, Suite 100 Winston-Salem, NC 27106 919/761-2351 Aiamarrce Alleghany Ashe Caswell Davidson Davie Forsyth Guilford Rockingham Randolph Stokes Surry Watauga Wilkes Yadkin Washington Regional WQ Super. P 0 Box 1507 Washington, NC 27889 919/946-6481 Beaufort Jones Berrie Lenoir Camden Martin Chowan Pamlico Craven Pasquotank Currituck Perquimans Dan; Pitt Cates Tyrell Greene Washington Y:etfoni Wayne Myth Mooresville Regional WQ Super. 919 North Main Street Mooresville, NC 28115 704/663-1699 Alexandre Cflbamrs Catawba Gaston Iredell Lincoln Mecklenburg Rowan Stanly Union Cleveland Raleigh Regional WQ Super. 3800 Barrett Dr., Suite 101 Raleigh, NC 27609 919/733-2314 Chatham Durham FAgecombe Franklin Granville Halifax Johnston Lee Nash Northampton Orange Person Vance Wake Warren Wilson Wilmington Region. WQ Super. 127 Cardinal Drive Extension Wilmington, NC 28405-3045 919/395-3900 Bnut_swick Carteret Columbus D uplin New Hanover Onslow Fender 7 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 8 (4/91) THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL Required Items a. One original and three copies of the completed and appropriately executed application form. b. Three sets of detailed plans and specifications signed and sealed by a North Carolina Professional Engineer. The plans must include a general location map, a plan view of the sewer extension, a profile of the sewer extension, details on the pump station, and must show the proximity of the sewer extension to other utilities and natural features. Specifications may be omitted for delegated authorities. Each sheet of the plans and the first page of the specifications must be signed and sealed. Three copies of the existing permit if a renewal or modification. c. Three copies of all calculations, including pump selection, friction calculations, cycle time, pump curves (including system curves applicable with one pump running, two pumps running, three pumps running, etc.), and evaluation of downstream pump stations. These items must be submitted under the signature and seal of the North Carolina Professional Engineer. d. The appropriate permit processing fee, in accordance with 15A NCAC 2H .0205(c)(5). e. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting the wastewater flow from this project is different from the applicant of the project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow that will be accepted. The letter should be a recent letter and should refer to the project by the same name as that identified on the application and the plans/specifications. f. An Operational Agreement (original and two copies) must be submitted if the sewer extension will be serving single family residences, condominiums, mobile homes, or town houses and if the subject sewer extension is owned by the individual residents, a homeowners association, or a developer. 8 of 10 RECEIVED: 3-12-99; 10:04AM; 9198767778 => CAMPBELL U.PHY.PLANT; 9198767776 PARKER 8 ASSOCIATES 413 643 P13 MAR 12 '99 11:27 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 9 (4/91) Name and Complete Address of Engineering Firm: Parr a Associates P.O. BOX 58475 City: Raleigh Telephone No. (919) 876--77/8 State: NC Zip: _ 27658 Professional Engineer's Certification: I, Dion J. Viveati , attest that this application for Cbe11 University Apt. Site has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this subrnival package may have been developed by other professionals, inclusion of these materials under my signature and seal siiiniEes that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Registration No. Print Name of Engineer Dian J. Viventi Seal and Signature (specify date): Applicant's Certification: I, Dr. James H. Ellerbe University Apts. , site 24643 EAL 4 q aj ..... ••,�N�Ji VNt: � W)-Dfr rge PemUttin9 , attest that this application for 0.mnrkw.11 WAr E�qE D CTION MAR 1 71999 has been reviewed by me and is accurate and complete to the best of my knowledge. I uaikrstand that if all required parts of this application am not completed and that if all required supporting information and attachments are not included, this application package will be returned as incomplete. — Signature 2/ Eilcd,k_ Date 3- I a; 99g ED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION ANMATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 512 NORTH SALISBURY STREET RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: 919/733-5083 9 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 10 (4/91) PERMIT APPLICATION PROCESSING FEES (effective October 1, 1990) CATEGORY NEW APPLICATIONS/ RENEWALS WITHOUT MODIFICATIONS MODIFICATIONS > 1,000,000 GPD Industrial $400 $300 Dornestic/Cooling Water $400 $300 10,001 - 1,000,000 GPD Industrial $400 Domestic/Cooling Water $400 $250 $250 1,001 - 10,000 GPD Industrial $400 $200 Domestic/Cooling Water $400 $200 < or = 1,000 GPD and Single Family Dwelling Sludge < or = 300 Acres Sludge > 300 Acres $240 $120 $400 $400 $250 $250 Sewer Extensions (nondelegated) $400 0 Sewer Extensions (delegated) $200 0 Closed -Loop Recycle or Evaporative $400 $200 NOTE: The Fees for Soil Remediation Projects are the same as for Sludges. Under the Sewer Extension Fee, "delegated to municipalities" applies only to those governmental jurisdictions that have specific delegation review authority, as granted by the Division of Environmental Management. 10 of 10