HomeMy WebLinkAboutWI0700508_DEEMED FILES_20200806Site FT007
Seymour Johnson Air Force Base
UIC Permit
RECEIVED
AUG 06 2020
NCDEQ/DWR
1 Central Office
NC Department of Environmental Quality-Division of Water Resources (DWR)
NOTIFICATION OF INTENT (NOi) TO CONSTRUCT OR OPERATE INJECTION WELLS
The following are "permitted by rule" and do not require an individual permit when constructed in accordance
with the rules of 15A NCAC 02C .0200 (NOTE: This form must be received at least 14 DAYS prior to in jection )
AQUIFER TEST WELLS (15A NCAC 02C .0220 )
These wells are used to inject uncontaminated fluid into an aquifer to determine aquifer hydraulic characteristics.
IN SITU REMEDIATION (15A NCAC 02C .0225 ) or TRACER WELLS (ISA NCAC 02C .0229):
1) Passive Injection S vstems -In-well delivery systems to diffuse injectants into the subsurface. Examples include
ORC socks, iSOC systems, and other gas infusion methods (Note: Injection Event Records (IER) do not need to be
submitted for replacement of each sock used in ORC systems).
2) Small-Scale In jection O perations -Injection wells located within a land surface area not to exceed 10,000
square feet for the purpose of soil or groundwater remediation or tracer tests. An individual permit shall be required
for test or treatment areas exceeding 10,000 square feet.
3) Pilot Tests -Preliminary studies conducted for the purpose of evaluating the technical feasibility of a
remediation strategy in order to develop a full scale remediation plan for future implementation, and where the
surface area of the injection zone wells is located within an area that does not exceed five percent of the land surface
above the known extent of groundwater contamination. An individual permit shall be required to conduct more
than one pilot test on any separate groundwater contaminant plume.
4) Air In jection Wells -Used to inject ambient air to enhance in-situ treatment of soil or groundwater.
5) In-Situ Thermal Wells (IST)-Used to 'heat' contaminated groundwater to enhance remediation.
Print Clearly or Type Information. Illegible Submittals Will Be Returned as Incomplete.
DATE: ____ ___, 20 PERMIT NO. iJf:(J:l{)J':so& (to be filled in by DWR)
NOTE-If this NOi is being submitted as notification of a modification of a previously issued NOI for this site ( e.g.,
different injection wells, plume, additives, etc.) and still meets the deemed permitted by rule criteria, provide the
previously assigned permit tracking number and any needed relevant information to assess and approve injection:
Permit No. WI~ ____________ Issued Date: _________ _
A. WELL TYPE TO BE CONSTRUCTED OR OPERATED
(1)
(2)
(3)
(4)
(5)
(6)
(7)
___ Air Injection Well ....................................... Complete sections B through F, J, M
___ Aquifer Test Well ....................................... Complete sections B through F, J, M
--~Passive Injection System ............................... Complete sections B through F, H-M
~X~ __ Small-Scale Injection Operation ...................... Complete sections B through M
___ Pilot Test.. ............................................... Complete sections B through M
___ Tracer Injection Well ................................... Complete sections B through M
___ In-Situ Thermal (1ST) Well. .......................... Complete sections B through M
B. STATUS OF WELL OWNER: Federal Government
Deemed Permitted GW Remediation NOi Rev. 2-17-2020 Page I
C. WELL OWNER(S) -State name of Business/Agency, and Name and Title of person delegated authority to
sign on behalf of the business or agency:
D.
E.
F.
Name(s): Gary Cox -Environmental Engineer, Restoration Team Robins Installation Supp ort Section
Mailing Address: 380 Robins Parkwav. Building 359
City: Robins Air Force Base State: GA Zip Code:-=3c....clc...=0--=-8-=--8 ____ County: Houston
Day Tele No.: 478-327-9269 Cell No.: 478-542-1335
EMAIL Address: 2arv.cox. L@us.af.mil Fax No.: ___ N~//-=--A~-------
PROPERTY OWNER(S) (if different than well owner/applicant)
Name and Title: ---------------------------------
Company Name ---------------------------------
Mailing Address:---------------------------------
City: _____________ State: __ Zip Code: _______ County: _____ _
Day Tele No.:_____________ Cell No.: ___________ _
EMAIL Address:______________ Fax No.: __________ _
PROJECT CONTACT (Typically Environmental Consulting/Engineering Firm)
Name and Title: ------'P~a=u=l_W~il=so=n~-~P~ro=j=e-=--ct~M=a=na""g""e"'"r __________________ _
Company Name ___ A~E~C-=O~M~-------------------------
Mailing Address: --~1=2 =12~0'-S=h=a=m=r=o~ck~P=laz=a .~S~u=it=e-=l=0~0 ________________ _
City: Omaha State: _J:lli__ Zip Code: 68154 County: Douglas
Day Tele No.: 402-952-2692 Cell No.: 402-681-9390
EMAIL Address: paul.m.wilson@~aecom.com Fax No.: ___________ _
PHYSICAL LOCATION OF WELL SITE
(1) Facility Name & Address: _S~e"---v=m=o~u=r-=J-=o=hn=s~o=n~A=F~B __________________ _
City: ------'G=o=l=d=sb=o=r=o ________ County: Wavn e Zip Code: 27531-2355
___
0
__ __" or _....,3""'5'-0=.3=5=3-=-49"'-0"--"-'N'-----(2) Geographic Coordinates: Latitude**:
Longitude**: D " or __ --=7-=-7....,0 .-=--97~4~1~6~7_W~---
Reference Datum: ________ Accuracy: _______ _
Method of Collection:_G-=--o~oc...g-=l~e -=--M~a=p~s ____________ _
**FOR AIR INJECTION AND AQUIFER TEST WELLS ONLY: A FACILITY SITE MAP WITH PROPERTY
BOUNDARIES MAY BE SUBMITTED IN LIEU OF GEOGRAPHIC COORDINATES.
G. TREATMENT AREA
Land surface area of contaminant plume:---=8=8-=-l _____ square feet
Land surface area ofinj. well network:._-=88=1=---____ square feet(::: 10,000 ft2 for small-scale injections)
Percent of contaminant plume area to be treated: 100 (must be::: 5% of plume for pilot test injections)
Deemed Permitted GW Remediation NOI Rev. 2-17-2020 Page 2
H. INJECTION ZONE MAPS -Attach the following to the notification.
(1) Contaminant plume map(s) with isoconcentration lines that show the horizontal extent of the
contaminant plume in soil and groundwater, existing and proposed monitoring wells, and existing and
proposed injection wells; and
(2) Cross-section(s) to the known or projected depth of contamination that show the horizontal and vertical
extent of the contaminant plume in soil and groundwater, changes in lithology, existing and proposed
monitoring wells, and existing and proposed injection wells.
(3) Potentiometric surface map(s) indicating the rate and direction of groundwater movement, plus existing
and proposed wells.
I. DESCRIPTION OF PROPOSED INJECTION ACTIVITIES AT THE SITE -Provide a brief narrative
regarding the cause of the contamination, and pwpose, scope, goals of the proposed injection activity:
FT007 is a former fire trainin g area where contaminated fuels . waste chemicals, and uncontaminated fuel were
burned. The former fire trainirnr area had an above-!!round storage tank (AST ) with a fuel line that ran to the
trainin l!. pit. Durin g fire training exercises , the pit was filled with water prior to addition of a pp roximatel y 500
gallons of fuel that would be i enited and extinguished. An undernround draina ge s ystem collected li quids and
drained them to an under gr ound oil/water se parator (OWS ). which then discharned to the sanitary sewers stem.
Ozone injection was historicall y compl eted at this site but has not reduced the contaminant concentration below
screenine levels. The ozone injection wells are no longer in use and will not be utilized in association with the
pro posed injections. The purp ose of the in jection activi ty is to accelerate site closure using potassium persulfate
injections. The in jectant material is Provect-OX2 which is an extended release source of potassium persulfate
plus a ferric iron activator. In jections will be com pleted in nine direct push borings (see attached Figure H.3 )
at hot s pots identified near performance wells MW-4 lR. MW-105R. and MW-106. The direct push borin e s will
be advanced to a predetermined de pth (see attached Table ) then retracted 3.5 feet to ex pose the injection interval.
Performance monitorin g will be initiated one month after the in jections and continue quarterly for one vear. If
needed a second injection event will be com pleted followin l.! the initial year of performance monitoring .
J. WELL CONSTRUCTION DATA
(1) No. of injection wells: ---~9 ___ Proposed __ ~O ___ Existing (provide NC Well
Construction Record (GW-1) for each well)
(2) Appx. injection depths (BLS ):-'s=e=e-=a=tt=ac=h=e=d-=T=a=b=le'---'1'-----------------------
(3) For Proposed wells or Existing wells not having GW-ls, provide well construction details for each
injection well in a diagram or table format. A single diagram or line in a table can be used for
multiple wells with the same construction details. Well construction details shall include the
following (indicate if construction is proposed or as-built):
(a) Well type as permanent, Geoprobe/DPT, or subsurface distribution infiltration gallery
(b) Depth below land surface of casing, each grout type and depth, screen, and sand pack
(c) Well contractor name and certification number-Redox-tech-Kyle Baseley,
NC Drilling License 4410-C
Deemed Permitted GW Remediation NO! Rev. 2-17-2020 Page 3
K. INJECTION SUMMARY
NOTE: On fr in iectants a pp roved br the e pidemiolo gv section o{the NC Division o f Public Health, Department
o f Health and Human S ervices can be in jected A pp roved in iectants can be fo und online at
http://deg.nc.gov/abouUdivisions/water-resources/water-resources-permits/wastewater-branch/1:tround-water-
protection/ground-water-approved-injectants . All other substances must be reviewed b1• the DHHS orior to use.
Contact the UIC Pro gram fo r more in fo i[1·ou wish to get a pnroval fo r a di ffe rent additive. However . p lease
note it mav take 3 months or lon ger. Ifno injectants are to be used use NIA.
Injectant.:....: --~P:,..Cr'--"o'-'-v--"'ec=t'-----O=X=2'--____ Total Amt. to be injected (gal)/event._,_: ---=1"'-6"""0c..=3'-'u=1a=ll=o=n~s ___ _
Injectant: Total Amt. to be injected (gal)/event-'-: __________ _
Injectant: Total Amt. to be injected (gal)/event-'---: __________ _
Injectant: Total Amt. to be injected (gal)/event_: __________ _
Injectant: Total Amt. to be injected (gal)/event-'---: __________ _
Total Amt. to be injected (gal/event): 1,603 gallons
No. of separate injection events .... :2 ___ Tota1Amt. to be injected (gal): ___ ~3.~2_0_6~g~a_ll~o_n~s ____ ~
Source of Water (ifapplicable): Potable water will be obtained from the wash rack located at FT007.
L. MONITORING PLAN -Describe below or in separate attachment a monitoring plan to be used to determine
if violations of groundwater quality standards specified in Subchapter 02L result from the injection activity.
Performance monitorim.!. will be completed quarterly starting one month after the completion of in jections to
allow the sodium persulfate to dissi pate. Durin!! the first round of sam pling, prior to purging, field testin g for
sodium persulfate will be conducted. If any persulfate is detected in uroundwater during this test, field parameters
will not be measured. When uroundwater is sam pled with persulfate present it interferes with water quali tv
probes and gi ves false readings. Groundwater sam ples will be anal vzed for VOCs and metals for four quarters.
Monitoring data will be utilized to determine if additional injections are re quired.
M. SIGNATURE OF APPLICANT AND PROPERTY OWNER
Well Owner/A pp licant: "I hereby certifY, under penalty of law, that I am familiar with the information
submitted in this document and all attachments thereto and that, based on my inquiry of those individuals
immediately responsible for obtaining said information, I believe that the information is true, accurate and
complete. I am aware that there are significant penalties, including the possibility of fines and imprisonment,
for submittingfalse information. I agree to construct, operate, maintain, repair, and if applicable, abandon the
injection well and all related appurtenances in accordance with the 15A NCAC 02C 0200 Rules."
~
COX.GARY.G.1277732692 Digitally signed byCOX.GARY.G.ll?7?32692 Gary G. Cox, Environmental Engineer, AFCEC/CZOE Date: 2020.07.30 11:14:5 7 -04'00'
Signature of Applicant Print or Type Full Name and Title
Pro pe rtv Owner (if the pro pe rty is not owned by the Well Owner/Applicant):
"As owner of the property on which the injection well(s) are to be constructed and operated, I hereby consent to
allow the applicant to construct each injection well as outlined in this application and agree that it shall be the
responsibility of the applicant to ensure that the injection well(s) conform to the Well Construction Standards
()5A NCAC 02C .0200)."
Deemed Permitted OW Remediation NOI Rev. 2-17-2020 Page4
"Owner" means any person who holds the fee or other property rights in the well being constructed. A well
is real property and its construction on land shall be deemed to vest ownership in the land owner, in the
absence of contrary agreement in writing.
Signature* of Property Owner (if different from applicant) Print or Type Full Name and Title
* An access agreement between the applicant and property owner may be submitted in lieu of a signature on this form.
Please send 1 (one) hard color copy of this NOi along with a copy on an attached CD or Flash Drive at least
two (2) weeks prior to injection to:
DWR-UIC Program
1636 Mail Service Center
Raleigh, NC 27699-1636
Telephone: (919) 707-9000
Deemed Permitted GW Remediation NOI Rev . 2-17-2020 Page 5
Table 1
J. Well Construction Data -Ff007 Injection Point Summary
Injection Nearest
Design Interval Design 1 Provect-OX2 Design Water Design Slurry
Point ID Monitoring (ft bgs) Mass Mass Mass
Well (lbs) (lbs) (lbs)
IP-1 MW-41 8.5-12 165 1485 1,650
IP-2 MW-41 8.5-12 165 1485 1,650
IP-3 MW-41 8.5-12 165 1485 1,650
IP-4 MW-106 11.5-15 165 1485 1,650
IP-5 MW-106 11.5-15 165 1485 1,650
IP-6 MW-106 11.5-15 165 1485 1,650
IP-7 MW-105R 9-12.5 165 1485 1,650
IP-8 MW-105R 9-12.5 165 1485 1,650
IP-9 MW-105R 9-12.5 165 1485 1,650
Notes:
All injection points will be installed using direct push injection . No permanent or temporary injection wells
will be installed.
Direct push injections will be completed by Well Contractor -Redox-Tech
1 Provect-OX2 is an extended release source of potassium persulfate plus a ferric iron activator.
See the Provect-OX2 attachment for more information.
ft= feet
ID = identification
lbs= pounds
bgs = below ground surface
sevmour Johnson AFB O:IDCS\Proj ects\ENV\Carolina Group PBR\9. SJ TT007\5. Injection Memo?/2712020 Page 1 of 1
A.
B.
C.
D.
E.
F.
G.
H.
SJAFB FT007
DEEMED PERMITTED GROUNDWATER REMEDIATION NOi
NOTES/COMMENTS FOR PERMIT APPLICATION
SECTIONS A THROUGH M
No change
No change
No change
No change
No change
No change
No change
1. The contaminant plume is shown on this figure. The contamination plume
is based on the analytical data from the most recent sampling in October
2019.
2. The cross section is from the Construction Completion Report for Ozone
Injection Remedial Action dated March 2017.
3. The potentiometric surface map and injection areas around monitoring
wells MW-41, MW-105R, and MW-106 are shown on this figure.
Historical contaminant plumes are shown due to the fact that current
concentrations at MW-41R do not exceed screening levels but historical
concentrations do exceed screening levels.
I. No change.
J. Existing ozone injection wells will not be utilized. Therefore, no construction
records for these wells are included. Direct push injection methods will be utilized.
Therefore, no construction records or well information are included. The depth of
injection, location, and quantity of material to be injected are included in Table 1.
K. Total gallons to be injected was calculated from planned pounds of water to be
injected in the approved work plan.
L. No change
M. No change
H.(1) FT007 CONTAMINANT PLUME MAP
TW$1
LEGEND
PLANNED MONITORING WELL
• OZONE INJECTION POINT
• pH ADJUSTMENT AND AIR SPARGE
INJECTION POINT
MONITORING WELL
MONITORING WELL — ABANDONED
PERFORMANCE MONITORING WELL
TREE LINE
VINYL CHLORIDE > 0.03 µg/L (OCTOBER 2019)
µg/L = MICROGRAMS PER LITER
A
A.IW-108
ROW C
MW-4I a �yy_11
MW-41 R43
•IW-12
1W-13 •
ROW B
IW-10r
DISTRIBUTION
PIPING
ROW A
_
r1W-9 ��
� f . — --,�i/ \
rI�V-8 ) •?
MW-1 O5R! POWER POLE/
IW-15 • I `1V--%= J TRANSFORMER
•11A1-7 ,�
• 161-1fi r•IW-3 /
MW-106 •IW A� J
/
■ IW-17•ti=
, � l4iW-4 / -
•IW-5 [`J� /
FORMER FIRE �"
GROUtJDW�A PIT EXCAVATION tY
�OW
e
OZONE AND pH
ADJU,_STMENT--, TRAILER
BUILDING
2100 '
WATER TANK
WASH
RACK
Ca
50 0 50
SCALE IN FEET
SITE FT007 VOCs DETECTED IN GROUNDWATER
SEYMOUR JOHNSON AIR FORCE BASE
June 09, 2020 8:26:59 a.m.
Drawing: ❑:/ DM, Projects\ENACAD/SJAFB\I6170782/38o61/2019\2-1.dwg
`—� DRN. BY: DPG DAM 06/09/20
CH[KD. BY: RF DAM 06/09/20
PROTECT NO. FIG, N0,
16170782 2-1
H.(3) FTOO7 POTENTIOMETRIC SURFACE MAP
and INJECTION_LO.0 .ATIONS
—1 1
TW-1
LEGEND
• PLANNED SODIUM PERSULFATE INJECTION POINT
■ OZONE INJECTION POINT
pH ADJUSTMENT AND AIR SPARGE
• INJECTION POINT
MONITORING WELL
MONITORING WELL — ABANDONED
PERFORMANCE MONITORING WELL
VINYL CHLORIDE ? 0.3 1.1g/L
( NOVEMBER 2015)
TREE LINE
EXCAVATED SOIL
NOTE:
GROUNDWATER ELEVATION DATA 15
FROM OCTOBER 2019
MW-108
AREA
280 S
80.9
•
•
FEE
RO
IP-
41
IP—
IW 12
81
IP—�
MW-106_.0.
80.731p_;•II
AR
31
GRQUNDWA TER
IW 16
W- 7
0
co
IP
1 05F
SIP
A
SQ FEET
Low
DISTRIBUTION
PIPING
ROW B
p/
IW-1 Oi N
■IW-9 \
ROW A
•1W-1
— a
8
AREA IW-2r
--7 288 Sq FEET
• IW-3
•Iw
• IW-5
BUILDING
2100
WATER TANK
•IW-4
OZO 1,E ANC pH
ADJUSTMENT
EQUIPMENT TRAILER 1t
POWER POLE/
TRANSFORMER
- FORMER FIRE
•445-
PIT EXCAVATION Dom'
50
0
50
1
SCALE IN FEET
PLANNED INJECTION POINT LOCATIONS
SEYMOUR JOHNSON AIR FORCE BASE
July 17, 2020 12:54;23 p.m.
Drawing: 0:/0051 Pro]acfs\EN \CAD/5JAF8/ 15170782/38A83/1.dwg
DRN. BY: DPG
C1 K D. BY: KK
DATE 08/28/19
DATE 08/28/19
PROJECT NO.
18170782
FIG. No.1
1
LEGEND:
WEST
A
100
90 -
70 -
60
SILTY SAND (SM)
SANDY CLAY (CL)
STIFF SILTY CLAY (CL) WI SAND
LAMINATIONS
DENSE, FINE SAND (SP) Wl FINE
LAMINATIONS OF CLAY AND ORGANICS
ROCK (CRUSHED STONE)
H.(2) FT007 CROSS SECTION
FILL MATERIAL
SIJRFICIAL
BLACK CREEK
BLACK CREEK CONFINING UNIT
MONITORING WELL SCREEN INTERVAL
-••• WATER TABLE SURFACE
- 60
50 0 50
HORIZONTAL SCALE IN FEET
10 5 0 10
ur--r�—err
VERTICAL SCALE IN FEET
CROSS SECTFON A -A'
SEYMOUR JOHNSON AIR FORCE BASE
December 12. 2014 8:31:06 a.m.
Drawing: T:\SJAFS\15170782\38AA1\f1g3-04.dwg
DRN. BY LLS DATE 12/12/14
CHECD. BY: BSC DAM 12/12/14
PROJECT NO.
16170782
F]G. NO.
3-4