Loading...
HomeMy WebLinkAboutWI0600226_DEEMED FILES_20210219Permit Number WI0600226 Program Category Deemed Ground Water Permit Type Injection Deemed Stormwater Drainage Well Primary Reviewer shristi.shrestha Coastal SWRule Permitted Flow Facility Facility Name Fayetteville Honeycutt Road Dollar General Location Address 1022 Honeycutt Rd Fayetteville NC 28314 Owner Owner Name Par 5 Development Group LLC Dates/Events Central Files: APS SWP Permit Tracking Slip Status Active Project Type New Project 2/19/2021 Version 1.00 Permit Classification Individual Permit Contact Affiliation Major/Minor Minor Region Fayetteville County Cumberland Facility Contact Affiliation Owner Type Non-Government Owner Affiliation Jamie S. Encinosa 2075 Juniper Lake Rd West End NC 27376 Scheduled Orig Issue 7/7/2020 App Received Draft Initiated Issuance 6/30/2020 Re g ulated Activities State Stormwater -Infiltration System Outfall Waterbody Name Public Notice Issue 7/7/2020 Re q uested /Received Events Streamlndex Number Current Class Effective 7/7/2020 Expiration Subbasin February 7, 2020 DWR-Aquifer Protection Section 1636 Mail Service Center Raleigh, NC 27699-1636 4Dsit solutions it Land ::u vi ng RE: Well Notification, Fayetteville Honeycutt Road Dollar General, Fayetteville, North Carolina To whom it may concern, We are submitting the notification for stormwater drainage wells for the Fayetteville Honeycutt Road Dollar General. This site contains an underground piped storm water infiltration system to comply with the storm water ordinance. Please contact me if you would like a copy of the site plan. I look forward to working with you on this project. If you have any questions or concerns, please contact me at your earliest convenience. Sincerely, 4D Site Solutions, Inc. Scott Brown, PE sb raw n @ 4d sitesol uti on s _co m Enclosure FEB 1 3 MO office i 910-426-6777 Fax . 910-426-5777 On time, every time.' )Awww.40sitesolutions.c. .. NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES NOTIFICATION FOR STORMWATER DRAINAGE WELLS Stormwater drainage wells are Class 5 injection wells "permitted by rule" and do not require an individual injection well permit when constructed in accordance with the rules of 1 5A NCAC 02C.0200 As described in I5A1VCAC 02C' . 022 7 this applies to rooftop runoff infiltration systems and certain other stormwater infiltration systems implemented as Best Management Practices designed in accordance with State stormwater regulations or an approved local government stormwater program. Additional guidance is available online at hap : por'tal.ncrtenrorrfweblwq/aAsIp pralinjectiun stormwater This notification form shall be submitted within 30 days of a change of status as described in Part D below, Print Clearly or Type Information. Illegible Submittals Will Be Returned As incomplete, DATE_ Febru rl 4 , 20 20 PERMIT NO. IA? 7r 6 ea 12(to be completed by DWR) A. STATUS OF WELL OWNER (choose one) (1) Single Family Residence (2) Business/Organization X (3) Government: State Municipal County Federal as B. WELL OWNER — For single family residences list the property owner(s). For all others, list name of the business, organization, or government agency and person delegated signature authority: Par 5 Development Group. LLC - Jod\ Bland. PE Mailing Address: 2075 Juniper Lake Road City: West End State: NC Zip Code: 27376 Ph#: 910-944-0881 EMAIL: jodv a: par5development.com C. WELL FACILITY (1) Name of Facility: Fa. etteville Hone cutt Road Dollar General (2) Physical Address: 1022 Honey cult Road City: Fayetteville State: NC Zip Code: 28314 Facility Location Identified By (check one): j X 1 Attached facilitti site map with ;rropert' boundaries, or [ j Geographic Coordinates: Latitude: Longitude: Reference Datum: _ Position Accuracy: Method of Data Collection: (3) D. WELL STATUS — Indicate the status of the well or well system (choose one): X Proposed Active Inactive Temporarily Abandoned Permanently Abandoned_ E. SIGNATURES — The following section is to be completed as required below or by that person's authorized agent. 15A NCAC 02C .0211(e) requires signatures as follows' L' IC Starmwater Injection Notification Form Revised 81812913) Page 1 (a) (b) (c) (d) (e) for a corporation: by a responsible corporate officer; for a partnership or sole proprietorship: by a general partner or the proprietor, respectively; for a municipality or a state, federal, or other public agency: by either a principal executive officer or ranking publicly elected official; for all others: by the well owner; for any other person authorized to act on behalf of the applicant: documentation shall be submitted with the notification that clearly identifies the person, grants them signature authority, and is signed and dated by the applicant. "1 hereby certify, under penalty of law, that I have personally examined and am familiar with the information submitted in this document and all attachments thereto and that, based on my inquiry of those individuals immediately responsible for obtaining said information, 1 believe that the information is true, accurate and complete 1 am aware that there are significant penalties, including the possibility offznes and imprisonment, for submitting false information. I agree to construct, operate, maintain, repair, and if applicable, abandon the injection well and all related appurtenances in accordance with the 15A NCAC 02C 0201 Rules." t2 `�- Signature 'roperty Owner/Applicant c1r, ti _S r 39 Print or Type Full Name Signature of Authorized Agent, if any Print or 'Type Full Nance Submit one copy of the completed notification package to: DWR — Aquifer Protection Section 1636 Mail Service Center Raleigh, NC 27699-1636 Telephone: 9 l 9-807-6464 I Fax: 919-807-6496 U1C Stormwater Injection Notification Forrn (Revised 8/8/2013) Page 2 u:on suoi}nposa}ssop mmm 'auto} AJana'aWl} uO LLLS-9Ztb-016 xUJ LLL9-9Ztr-OT6 aayio 90M! DN 'allrnallaAP "�Tj aims 'anttp o6eDILO bob OZOZ E 183.E aJnsolou3 woa•suohnlosaiispti uMOJgs 3d 'UMOJB 1103S V� •:)ul suoilnlos ails av 'AlaJa:)UIS 'a3ualUanuoa IsailJea JnoA le aw }:)eluo:) aseaid 'suJaauo:) Jo suollsanb Aue aneq noA 11 -pa(oid slgl uo noA gilts SuljJOM ol pJeMaoj lool I •ueld ails aq} jo Ado:) e mill pinoM noA jl aw pewoo aseaid •aaueulpJO J@IeM wjols aqj gllM Aldwo:) of walsAs uolleJllgul JaleM wjols padld punoJSJapun ue suleiuoa ails sigl'leJauag Jelloa peo�l jjn:)AauOH alllnaUaAe3 aq, Jol sham aSeuleJp Ja;eMUJJois Jol uolle:)llllou alp Suinpgns aJe aM 'uJa:)uo:) Aew 1! LuogM euyaJej g:PoN `alllnaIlaAe3 `jejaua!) Jelloo peoU l}n:)AauOH allinaIlaAe3 `uolle:)13l10N llaM =38 6uRlanuns puel l 6UIJaaU16Ua Iinra suotlnlos @ITS(jv 9E91-669LZ :)N ' Ja;U@D a:)lnJas LIM 9rt4T uoh.aas uoll:)aIoJd Japnbv�-mA%a ©ZOZ `L AJenxlaj I OBud (£IOZ/8/8 POSina-i) nuo3 uoiluOguoN u01133Cul131VAI u¢oIS 0Ifl :SMoIIO3 su saanWals sazmI IZO• JZO DVba.r a NVSI -luau pozrroupnu s,uosiod lugl Sq ro molaq paunbw su palaidwoo aq of sl uol;oas Rurm01103 aril — Sa2IfILVN9IS.11 -pauopuugy uuuod pouopuugV Xluuiodmol, anrIouul anlJod pasodoad X :(auo osoogo) uza;sXs Mann Jo [lam arl;Io smuts arll aluoipuI — SfIjLV.LS ZZdM V :u0t1301100 uluQ3o PoulaY�I ioumoo� uo.1. :urn473Q aoua.ralag :Qprnlouo7 :3pnliju7 :SQluurpmoD olrldur2oa0 [ 10 sal.Ivpunoq a oa q;im clutu a;!s tliaul pagae�` X :(Quo 3133go) gig pagijuapl uotIu30-1 /,jrlto723 (£) bI £8Z :apoD diZ JN :ale1S alpnau3. u j puoZl Uno auoH ZZOI :ssarppv Isotssgd (Z) Iu.zau;)D XL'IIoQ Puo?I }ono auoH allln343 u,I :,i4!jImAjo auruN (I) AZI7I3V3 7I21M 'O uroa �uaur olanapsru po :-I VWH I880-tb6-016 :#ud 9L£LZ :apoo d1Z pug lsaA1 :4 puo2l alu7 ra Iunf SLOZ :ssaippV 5uTI? W 'Ltd PuL'ig ApOf - D'TI noaO ;uaul OJOA3a S JVd :"41aog1nu om1mois palu�alop uosrad puv /iou35u luauuuano.2 do `uouuzruugio `ssauisnq aqj Io auruu Isll °s.raq{o IIu .103 •(s)aaunno f4jodoid oql Isll saouaplsai (Buret abuts .zo3 — 2I3NA* IuzQPad ,ilunoD IudtorrmW NUTS :Iuauru;)AOD (£) ?,• X uo';ez'ue2la0/ssauisng (Z) aouapiSa21 XIIIUu,I al.&TrS (i) (auo asooga) HaNMO 'I'IgM 30 SfI LV.LS v (,dMQ Xq pazaiduroa aq ol) 'ON .LIL1IN3d OZ OZ r -` mugad :3 T v" alalduloaul sv pauaulam ag llul vlvllnugnS olglfalll 'uozlvzu rofuj ad f'L ro fltvalJ luzjd .,Aolaq Q l.svd uz pa4!aosap sv sninis fo a8ungo v fo S'dvp O f- uzr/lt^1 pall!wgns aq llvgs ru rof uozlva ylou sirl .ralvnvu cols uotlaa• uzlo r mf1sav1bn1q94t1ffi5 -duapou •lvl.ro ll: llq lv auyuo algv1ivnv sr aouvpzn2 IvuorizppV •urv-&6.rd aalvnaru rots luawu raao2 lvool paao rddv uv ao suozlvin8a r [alvnaru.rols alvls glzM aauvp roaav uz pau�rsap saazlov td luaura2vuvN wag sv paluauraldurz srualsrds uozlv[llfuz lalvmuuols .raglo uzvl.raa puv vwals,,Cs uozlv4lyuz ffoum dolfoo r of sai1ddv szrll ZZZO- J,70 3vDAr Y SI uz pagyosap sy 'OOZO' DZO DYDt- of -i fo saln.r aril gl!A aouvpd000v uz palon4moo uallA pwiadNana uopoaful lvnpztizpuz uv agnbaa lou op puv „a1w dq pallzuuad, slla K uozloalur S- ssvlD a.1v sllaaa a2vuzv.sp ralvAwdOls S`I'I31M aOVNIVH(t H:I LVAc1I^ ols Hod NOI.LV31AILON cu "L v iNL k--L'tv LI'NL LYVIXU MANd dU .LNAAIZlddHG VNI'IO'dVD HI'dON Z a5ed (£l OZ/8/8 pos-31d) uuo3 u0117309[;oN uoiloaful JOILAAuuotS DIfl 96t,9-L08-6I6 :Xu3 I t79t,9-L08-6I6 :auolldoloL 9£9I-669LZ ON `u-5!3jB-d 13luaD aainuas IILw 9£9I uollaaS uoilaaloadaajlnbd—?IMQ of 30goud uollvogpou palajdwoo aql jo Xdoo auo IlwgnS OmVK fln3 ad,f,L io luuj due;►';uaN'V pazfioglnV jo ain;uatS auiell Ifni ad f,L ao ;u►ad ;uea1lddVpau.ap ,Cuado.j jrp amugu2jS ., waing OOZO D-0 DVDVV V91 OW VA' aouvpd000v ut saouvuajmddv palvlad 11v puv plans uo11 alur atlj uopuvqv `ajgvolpddv fi puv ,nvdar u.lvlu.vw 'aimado jon4,vuoo of aad8v I •uoyvuuofup aslvf 81qnrusgns [of `ivawuosudurr puv sau ff fo dj!lpglssod aqj 8uppnjoui `sop�lvuad 1uvoyiuSu a ry adagj jvgj amtw urn I -alaldtuoo puv aimnoov `an4 sl uoilvtu rofur ap, Ivzl; atalpaq I `uoz�vur.roful pzvs 8uruivlgo Hof algpsuodsa r rflalvrpaururr slvnppnrpul asogj fo Qinbu.i dw uo posvq Ivgl puv olaiagl sluauapovlly jpv puv lualunoop silgj ut pan urgns uoilvwdofur aqj rljlaa rvtjturvf lav puv pauttuvxa dllvuostad aavq 11vg1 `Mvp fo ,, zjvuad spun `dfy.iao dgaiaq I„ wuailddu oql iq palup puu poals si pine `ri4uowu a'Wais utaq; sluut `uosaad aqj saguuapi Xlrualo WIT uoiluagRou aq1 gpim pauiutgns oq Ilugs uoPuluatunoop :Iuuailddu aql jo 31ugaq uo jou of pazuogjnu uoszad .tatpo Xuu jo3 (a) `.Joumo Ilam atp ,iq : s taglo IIu to3 (P) `Iuiog�o pa�aala �lailgnd gui}Itzut zo t33g3o OAgnoaxa ludioui.td u zapa Xq :Xoualau atlgnd .tatgo .to `lu.tapa3 `alujs u zo �411udioiunw u ioj (o) `Xlaniloodsaa `iololidotd oql zo .taus and lu.taua.� u Xq :digsio;audojd olos zo digstaultud u zoo (q) `laogjo aluzodaoo algisuodsw u �q :uoilu.todtoo u .toj (u) z C-D o OMAIN ST Dj c) 0 z 51 WINTHROP CT m z �- _z m :�i ,off � Z � O � OFAYETTEV 'p � C 0 C LAYTO N DR o L-,B RAXTO N B LVD _ > CD J PALM SPRING RD B E LLA CQ �� MVISTA�� OR CCD > �yG SITE VICINITY MAP NOT TO SCALE ARTEMIS z n , c,n1 A SA O ,v NORTH EXISTING UTILITY OWNER WATER PWC OF FAYETTEVILLE 955 Old Wilmington Road Fayetteville, North Carolina 28301 910-223-4370 Contact: Sam Powers, PE Know what's below. Call before you dig. ROAD D SITE D,FV- HONEYCUTT Z GE'NERAL )-P--M-F- NS UNNAMED 20, STREET INDEX OF DRAWINGS C1.0 - C2.0 - C2.1 - C3.0 - EXISTING CONDITIONS SITE PLAN LANDSCAPE PLAN GRADING PLAN C4.0 - EROSION CONTROL PLAN C5.0 - UTILITY PLAN C6.0 - PROFILES C7.0 - 7.1 - SITE & EROSION CONTROL DETAILS C7.2 - SITE & STORM DETAILS C7.3 - STORM & WATER DETAILS C7.4 - STORM DETAILS CIVIL ENGINEER OWN ER/DEVELOPER SURVEYOR 4D SITE SOLUTIONS, INC. PAR 5 DEVELOPMENT GROUP, LLC 4D SITE SOLUTIONS, INC. 409 Chicago Drive - Suite 112 2075 Juniper Lake Road 409 Chicago Drive - Suite 112 "MCA"''''% "'CAlilt"'% Fayetteville, North Carolina 28306 West End, North Carolina 27376 Fayetteville, North Carolina 28306 SEA _ AL _ 027 = 457 910-426-6777 910-944-0881 910-426-6777 .a SCOrTEgI�,•'a��� �pROS��J��-��• Contact: Scott Brown, PE Contact: Jody Bland Contact: Jimmy Holland, PLS%�,,,,,,,,,,���6' email: sbrown@4dsitesolutions.com email: jody@par5development.com email: jholland@4dsitesolutions.com U5" U�/-�U bs_b4-2b 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite 112, Fayetteville, NC 28306 office 1910-426-6777 fax 1910-426-5777 license number I C-2354 wwwAD site solutions.com REVISIONS ISSUED FOR CONSTRUCTION PROJECT NAME FAYETTEVILLE HONEYCUTT ROAD DOLLAR GENERAL TAX I D# 0521-50-7016 1022 HONEYCUTT ROAD CARVERS CREEK TOWNSHIP CITY OF FAYETTEVILLE CUMBERLAND COUNTY NORTH CAROLINA CLIENT PAR 5 DEVELOPMENT GROUP, LLC 2075 Juniper Lake Road West End, North Carolina 27376 Phone: (910) 944-0881 PROJECT INFORMATION DESIGNED BY: SCOTT DRAWN BY: SCOTT CHECKED BY: CHRIS PROJECT NUMBER: 1485 DRAWING SCALE SEE SHEETS DATE RELEASED MAY 4, 2020 THE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 A MINIMUM OF 72 HOURS PRIOR TO DIGGING IN ORDER TO HAVE THE EXISTING UTILITIES LOCATED VICINITY MAP NOT TO SCALE LEGEND: EAI O EAI-EXISTING ANGLE IRON ECM® ECM -EXISTING CONCRETE MONUMENT EIP 0EIP-EXISTING IRON PIPE EIR 00 EIR-EXISTING IRON ROD EPKO EPK-EXISTING PK NAIL ENL0 ENL-EXISTING NAIL ERB 0 ERB-EXISTING REBAR slze0 SRB-SET REBAR o COMPUTED POINT N/F - NOW OR FORMERLY R/W - RIGHT OF WAY POB - POINT OF BEGINNING POC - POINT OF COMMENCING PROPERTY LINE ADJACENT PROPERTY LINE TIE LINE RIGHT-OF-WAY -SETBACK LINE SD STORM DRAINAGE w WATER LINE OVERHEAD UILITY X FENCE LINE WOODEN FENCE PERMANENT EASEMENT TREE LINE 260 MAJOR CONTOUR 262 MINOR CONTOUR x 260.52' SPOT ELEVATION -0-BENCHMARK SIGN SIGN EB ELECTRICAL BOX PP • UTILITY POLE C GUY WIRE ❑T TELEPHONE PEDESTAL FIRE HYDRANT ❑❑ WATER METER ® CATCH BASIN ® DROP INLET TREE 0 ASPHALT CONCRETE BUILDINGS COMMITMENT NO. 201900709ASL/RC/02, EFFECTIVE DATE: FEBRUARY 15, 2019 REVISED APRIL 9, 2019 SCHEDULE B - SECTION II 1. TAXES FOR THE YEAR 2019, AND SUBSEQUENT YEARS, NOT YET DUE AND PAYABLE. (NOT A MATTER OF SURVEY) 2. SUBJECT TO MATTERS SHOWN ON PLAT RECORDED IN MAP BOOK 134 AT PAGE 157 (PARCEL ONE). (AFFECTS SUBJECT PROPERTY, SHOWN ON SURVEY) 3. RIGHTS OR CLAIMS OF PARTIES IN POSSESSION NOT SHOWN BY THE PUBLIC RECORD. (NOTE: THIS EXCEPTION WILL BE DELETED FROM FINAL POLICY UPON RECEIPT OF ATTORNEY CERTIFICATION THAT PROPERTY IS OWNER OCCUPIED) (NOT A MATTER OF SURVEY) 4. ANNEXATION ORDINANCE RECORDED IN BOOK 9329 AT PAGE 270 (PARCEL ONE). (AFFECTS SUBJECT PROPERTY, SHOWN ON SURVEY) 5. EASEMENT(S) TO DEPARTMENT OF TRANSPORTATION RECORDED IN BOOK 4269 AT PAGE 75 (PARCEL TWO). (AFFECTS SUBJECT PROPERTY, SHOWN ON SURVEY) 6. TITLE TO THAT PORTION OF THE LAND WITHIN THE RIGHT-OF-WAY OF MCARTHUR ROAD (SR 1600) AND HONEYCUTT ROAD (SR 1613) (PARCEL TWO). (NOT A MATTER OF SURVEY) 5. [INTENTIONALLY DELETED] 6. ANY INACCURACY IN THE AREA, SQUARE FOOTAGE, OR ACREAGE OF THE LAND DESCRIBED IN SCHEDULE A OR ATTACHED PLAT, IF ANY. THE COMPANY DOES NOT INSURE THE AREA, SQUARE FOOTAGE, OR ACREAGE OF THE LAND. (NOT A MATTER OF SURVEY) 7. ANY ENCROACHMENT, ENCUMBRANCE, VIOLATION, VARIATION, OR ADVERSE CIRCUMSTANCE AFFECTING THE TITLE THAT WOULD BE DISCLOSED BY AN ACCURATE AND COMPLETE LAND SURVEY OF THE LAND. THE TERM "ENCROACHMENT" INCLUDES ENCROACHMENTS OF EXISTING IMPROVEMENTS LOCATED ON THE LAND ONTO ADJOINING LAND, AND ENCROACHMENTS ONTO THE LAND OF EXISTING IMPROVEMENTS LOCATED ON ADJOINING LAND. PARAGRAPH 2 (C) OF THE COVERED RISKS IS HEREBY DELETED. (IF AFFECTS SUBJECT PROPERTY, SHOWN ON SURVEY) NOTES: 1. ALL DISTANCES SHOWN ARE HORIZONTAL GROUND DISTANCES UNLESS OTHERWISE NOTED. 2. COMBINED SCALE FACTOR: 1.00005595 LOCALIZATION POINT N: 946,515.088 E: 2,188,249.685 CONTROL ESTABLISHED VIA NORTH CAROLINA GEODETIC SURVEY VIRTUAL REFERENCE SYSTEM. 3. THE HORIZONTAL AND VERTICAL CONTROL FOR THIS SURVEY WERE ESTABLISHED USING THE NORTH CAROLINA GEODETIC SURVEY VIRTUAL REFERENCE SYSTEM. 4. LINES NOT SURVEYED ARE SHOWN AS DASHED LINES FROM INFORMATION REFERENCED ON THE FACE OF THIS MAP. 5. NONCONFORMING STRUCTURES HAVE NOT BEEN CREATED BY THIS SURVEY. 6. THE SUBJECT PROPERTY IS THE SAME AS THE PROPERTY DESCRIBED IN THAT CERTAIN TITLE COMMITMENT ID. 201900709ASL/RC/02 ISSUED BY INVESTORS TITLE INSURANCE COMPANY WITH AN EFFECTIVE DATE OF FEBRUARY 15, 2019, REVISED APRIL 9, 2019, AND ALL EASEMENTS, COVENANTS AND RESTRICTIONS REFERENCED IN SAID TITLE COMMITMENT OR APPARENT FROM A PHYSICAL INSPECTION OF THE SUBJECT PROPERTY OR OTHERWISE KNOWN TO ME HAVE BEEN PLOTTED HEREON OR OTHERWISE NOTED AS TO THEIR EFFECT ON THE SUBJECT PROPERTY. 7. LOCATIONS OF ALL UNDERGROUND UTILITIES LYING WITHIN THIS MAPPED AREA MAY NOT BE SHOWN ON THIS PLAN. DEVELOPERS OR CONTRACTORS SHOULD NOT ONLY MAKE SUBSURFACE INVESTIGATIONS BUT SHOULD ALSO ALLOW FOR CONTINGENCIES WHICH MIGHT ARISE BY REASON OF ENCOUNTERING UNRECORDED LINES OR OF LINES BEING IN DIFFERENT LOCATIONS THAN INDICATED ON THIS SURVEY. 8. THIS PROPERTY LIES WITHIN FLOOD ZONE "X" ACCORDING TO MAP# 3720052100J OF THE FLOOD INSURANCE RATE, DATED JANUARY 5, 2007. 9. THERE WAS NO EVIDENCE OF RECENT EARTH MOVING WORK, BUILDING CONSTRUCTION, OR BUILDING ADDITIONS OBSERVED IN THE PROCESS OF CONDUCTING THE FIELDWORK. 10. THERE HAVE NOT BEEN ANY PROPOSED CHANGES IN THE STREET RIGHT OF WAY LINES, IF SUCH INFORMATION IS MADE AVAILABLE TO THE SURVEYOR BY THE CONTROLLING JURISDICTION. THERE WAS NO EVIDENCE OF RECENT STREET OR SIDEWALK CONSTRUCTION OR REPAIRS OBSERVED IN THE PROCESS OF CONDUCTING THE FIELDWORK. I, SEAN R. SEEVER, CERTIFY THAT THIS SURVEY IS OF AN EXISTING PARCEL OR PARCELS OF LAND OR ONE OR MORE EXISTING EASEMENTS AND DOES NOT CREATE A NEW STREET OR CHANGE AN EXISTING STREET. ✓�LQ,Q�.-Q .� . ---------- ------------------------------ PROFESSIONAL LAND SURVEYOR — L-4571 I, SEAN R. SEEVER, CERTIFY THAT THIS MAP WAS DRAWN UNDER MY SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION (DEED DESCRIPTION RECORDED IN BOOK SHOWN PAGE HEREON OR OTHER REFERENCE SOURCE -----------------); THAT THE BOUNDARIES NOT SURVEYED ARE INDICATED AS DRAWN FROM INFORMATION IN BOOK -----, PAGE ----- OR OTHER REFERENCE SOURCE -----------------; THAT THE RATIO OF PRECISION OR POSITIONAL ACCURACY IS 1:10,000+; AND THAT THIS MAP MEETS THE REQUIREMENTS OF THE STANDARDS OF PRACTICE FOR LAND SURVEYING IN NORTH CAROLINA (21 NCAC 56. 1600). WITNESS MY HAND AND SEAL THIS Q DAY OF MAY, 2020. JJ20.,R. PROFESSIONAL LAND SURVEYOR — L-4571 I I 3/8" ERB— — NO �iCARo ��V ..'•F S O •• �� SAL ma's III457 - �i0' SUR" 'V//' /IIRI 1 �S````` bs°b4•2b I, SEAN R. SEEVER, CERTIFY THAT THE CONTROL FOR THIS SURVEY WAS ESTABLISHED FROM AN ACTUAL GPS SURVEY UNDER MY SUPERVISION. THIS GPS SURVEY WAS PERFORMED TO C-211 FGCC SPECIFICATIONS RTK GPS WITH VRS FIELD PROCEDURES WERE USED. THE COORDINATES WERE OBTAINED THROUGH A GRID TO GROUND ADJUSTMENT USING THE COMBINED SCALE FACTOR SHOWN HEREON. THIS SURVEY WAS PERFORMED ON MAY 30, 2019 USING TWO TRIMBLE 5700 RECEIVERS. �. ------------ --------------------------- PROFESSIONAL LAND SURVEYOR - L-4571 TOTAL AREA: (BY COORDINATE COMPUTATION) 50,661 SF (1.16 AC) PIN NO: 0521-50-7016 ZONING R6A LC C1(P) CU FRONT 25' 25' 45' SIDE 10' 3' 15' REAR 30' 10' 20' TO VERIFY CITY SETBACK INFORMATION CONTACT THE CITY OF FAYETTEVILLE PLANNING DEPARTMENT 910-433-1329 TO VERIFY COUNTY SETBACK INFORMATION CONTACT THE CUMBERLAND COUNTY PLANNING & INSPECTIONS DEPARTMENT 910-678-7600 SOURCE OF TITLE DB 3446, PG 34 DB 9259, PG 280 DB 9302, PG 276 CUMBERLAND COUNTY REGISTER OF DEEDS 1" EIP 5/s" SPEED sRe BUMP 3/8", EAI ERB TWIN 267 N /F 30" ERNEST J. DARDEN & WIFE, PINES n H. JACQUELYN 0. DARDEN DB 4233, PG 210 ZONING: R6 266 %/ —PP 26 — _SPEED SPEED 263 26Q UNNAMED 20' STREET BUMP/ - BUMP O = - - - _ - _ - 5/8" - - - - - - - - - sR6 S87°49'57"E 200.00' TIE— \ _ 20" 264 EIP itS� 16' CEDAR CEDAR N87°49'57"W 192.00' 262 pp O CONC WELL PAD \ EUREKA SPRINGS LAN[ TRACT TWO C ` DB 9259, PG ZONING: R6/ \ PIN 0521-50-6 N /F TRUSTEE OF THE J.D. ELLIOTT REVOCABLE TRUST I� TRACT 6 \ DB 8881, PG 40 ZONING: R6A 261 \ EIP r v G ` ��q lull, Z �— N 2 N �` 2-0 N /F 7� m BARBARA A. ELMORE & HUSBAND, BORIS ALLEN ELMORE DB 8585, PG 70 ` PB 128, PG 17 ZONING: R6A / 3/8„ / ERB \ o 0 � o N /F ROBERT RUBIO ACOSTA DB 8483, PG 571 \ PB 128, PG 17 ZONING: R6A TBM: \ 4D COTTON SPINDLE #1 263 3/8' ERB 5" HW ERB IKL JO 1 \ 8" ®� HW 8 PINE \ I n 8 \ 6" HW %P ECM S16°37'39"E 21.22' TIE 10" PINE N: 510,207.816 1" EIP (PINCH TOP) ® E: 2,025,988.765 NC GRID NAD 83 18" (2011) PINE X / 266 x c� CA N. TKINS, JR. & 265 WATKINS ONE X PG 78 C1(P) o o_ X N /F JAMES R. PEADEN TRACT 6 DB 5223, PG 305 CARPORT DB 2554, PG 15 / 1„ ZONING: Cl(P) EIP X X X V0 S87°49'57"E 200.00' TIE N: 510,092.189 263 E: 2,026,012.543 NC GRID NAD 83 \ \ 262 (2011) \ PP � 262 \ PUMP LLL���"` ___HOUSE \ \ 260 \ \ " 261 \ cri \ 259 A N/F N /F BOBBY COTTON MCCAULEY & MCDONALD INVESTMENTS, INC. DB 3725, PG 172 CA DB 3446, PG 34 \ ZONING: Cl(P) •U, ZONING: Cl(P) CU 6' \ PIN 0521-50-8080 \� \ N. \\ \ 260 \ 260 8„ PINEPIP \ N\ \ EUREKA SPRINGS LAND CO., LLC TRACT ONE OF DB 9259, PG 280 \ ZONING: R6A TEMPORARY \ \ PIN 0521-50-8020 DRAINAGE EASEMENT \ DB 4269, PG 75 \ N: 509,923.954 y DI #8146 ^ 259 D 7 DI #8525 ° E: 2,025,619.859 261 i GRATE 259.14 THE POLE IS \ GRATE 258.81 GRATE 258.90 \ ELEV: 262.15 N INV OUT 256.42 CORNER INV OUT 253.74 INV OUT 253.82� NC GRID NAD 83 3/ ( 3/8" 1 3/8" 5/8" N(20 1) EPK OEPK ER, - A RCP ERB — — ao — — — — ERB SRB— — AVD - w ENIp' ERB'` 262 N87°19'02"W 171.31' ( 3/8"24" RCP-0 3/8" R=830.29' ERB SD SD O7� 3/8" ERB L=9.08' g1 CI'#8208 260 —zzz Lh 3/8" ERB CHORD 2� HOOD 260.66 w8 W8 — HONEYCUTT ROAD - SR 1613 ERB w8 w8 s WB INV IN 255.95 8146 W8 wa we _N87°37'50"W )' -INV IN 250.50 (8271) 95' R/W (PUBLIC) HONEYCUTT ROAD - SR 1613 80' R/W (PUBLIC) I, SEAN R. SEEVER, CERTIFY THAT THIS CLASS "C" TOPOGRAPHIC MAP WAS DRAWN FROM AN ACTUAL SURVEY PERFORMED UNDER MY DIRECT SUPERVISION AND THAT IT MEETS OR EXCEEDS THE NORTH CAROLINA ADMINISTRATIVE CODE 21.56.1605 AND 21.56.1606. WITNESS MY HAND AND SEAL THIS d DAY OF MAY, A.D., 2020. �. ------------JNALCLANDPROFESSI SURVEYOR - L-4571 I/F ;S LAND CO., LLC DB 9302, PG 276 ZONING: LC PIN 0521-50-7016 CITY OF FAYETTEVILLE ANNEXATION ORDER # 2013-09-545 DB 9329, PG 270 WELL 71 /I � v 260 rn 0 6 STUB 0 ;ONC ee \10 PAD N87°49'57"W 12.00' 3/8" ERB 12" HW 260 WELL 12" HW PAD EIP 1" EIP (PINCH TOP) 3/8" ERB o 3/8" ERB 261— 9.08 INV OUT 250.50 8 N CL II Ckf c II N 0 CI #8271 HOOD 259.28 -- --_ -- --- --- -- INV OUT 250.85 1"EIP 5/8" 264 (PINCH TOP) ERB DI #8514 259 GRATE 258.38 INV OUT 253. 6 IL CI #8273 HOOD 258.63 s _INV IN 252.77 (8514) _ INV IN 249.41 (8208) INV OUT 249.40 30 N /F BOBBY COTTON DB 2743, PG 377 ZONING: Cl(P) CU GRAPHIC SCALE 0 15 30 60 120 ( IN FEET ) 1 inch = 30 ft. 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite 112, Fayetteville, NC 28306 office 1 910-426-6777 fax 1910-426-5777 license number I C-2354 www.4Dsitesotutions.com 1111 ```\\\`uCARo �Z/ i Q�` .•••• •••• �/� es S a4 _ sF•:;;•SU9 � R l'S��c ``� bs �bL+- REVISIONS ISSUED FOR CONSTRUCTION PROJECT NAM FAYETTEVILLE HONEYCUTT ROAD DOLLAR GENERAL EXISTING CONDITIONS CLIENT PAR 5 DEVELOPMENT GROUP, LLC 2075 Juniper Lake Road West End, North Carolina 27376 Phone: (910) 944-0881 PROJECT INFORMATION SURVEYED BY: MIKE DRAWN BY: SEAN CHECKED BY: JIMMY PROJECT NUMBER: 1485 DRAWING SCALE HORIZONTAL: 1 "=30' DATE SURVEYED MAY 30, 2019 SHEET NUMBER C-1 no VICINITY MAP NOT TO SCALE LEGEND: EAI O EAI—EXISTING ANGLE IRON ECM® ECM —EXISTING CONCRETE MONUMENT EIP Oo EIP—EXISTING IRON PIPE EIR Oo EIR—EXISTING IRON ROD EPKO EPK—EXISTING PK NAIL ENLO ENL—EXISTING NAIL ERBO ERB—EXISTING REBAR SRBO SRB—SET REBAR o COMPUTED POINT N/F — NOW OR FORMERLY R/W — RIGHT OF WAY POB — POINT OF BEGINNING POC — POINT OF COMMENCING PROPERTY LINE ADJACENT PROPERTY LINE TIE LINE RIGHT—OF—WAY SETBACK LINE SD STORM DRAINAGE W WATER LINE // OVERHEAD UILITY X FENCE LINE WOODEN FENCE PERMANENT EASEMENT TREE LINE 260 MAJOR CONTOUR 262 MINOR CONTOUR x 260.52' SPOT ELEVATION -0-BENCHMARK S-,GN SIGN EB ELECTRICAL BOX PP • UTILITY POLE C GUY WIRE ❑T TELEPHONE PEDESTAL FIRE HYDRANT 0 WATER METER ® CATCH BASIN ® DROP INLET TREE 0 ASPHALT CONCRETE BUILDINGS SITE NOTES 1. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE BENCHMARK AND MUST BE VERIFIED BY THE GENERAL CONTRACTOR. 2. EXISTING UNDERGROUND UTILITIES ARE SHOWN ONLY WHERE EVIDENCE COULD BE FOUND TO VERIFY LOCATION. PRIOR TO CONSTRUCTION OR EXCAVATION OF THE SITE, THE GENERAL CONTRACTOR SHALL VERIFY ALL UTILITY COMPANIES TO VERIFY THE LOCATION OF THEIR RESPECTIVE UTILITIES. ALL DAMAGE INCURRED TO EXISTING UTILITIES DURING CONSTRUCTION SHALL BE REPAIRED AT THE GENERAL CONTRACTOR'S EXPENSE. 3. ASPHALT AND BASE TYPE SHALL BE PER THE DETAILS. 4. HANDICAP RAMPS, SIGNAGE AND PARKING SPACES SHALL BE PROVIDED BY THE CONTRACTOR AND INSTALLED PER FEDERAL ADA AND LOCAL REQUIREMENTS. 5. ALL DIMENSIONS ARE TO THE BACK OF CURB OR TO THE FACE OF SIDEWALK UNLESS OTHERWISE NOTED. 6. ALL RADII ARE 5' UNLESS OTHERWISE NOTED. 7. PARKING STALLS MUST BE STRIPED WITH A 4 INCH CONTRASTING STRIPE (YELLOW ON CONCRETE AND ASPHALT PARKING LOT). 8. HANDICAP PARKING SPACES ARE TO BE DESIGNATED BY BLUE STRIPING AND EITHER A BLUE SYMBOL ON A WHITE BACKGROUND OR A WHITE SYMBOL ON A BLUE BACKGROUND. ALL HANDICAP PARKING STALLS REQUIRE THE INSTALLATION OF THE PROPER SIGNAGE. 9. ALL PARKING SPACES ARE TO BE LAID OUT IN ACCORDANCE WITH THE SITE PLAN DIMENSIONS. 10. ALL WASTE MATERIAL SHALL BE DISPOSED OF OFF —SITE IN ACCORDANCE WITH STATE AND LOCAL LAWS AND REGULATIONS. 11. ALL SITE IMPROVEMENTS SHALL BE INSTALLED PER CITY OF FAYETTEVILLE AND STATE REGULATIONS. SITE DATA DEVELOPER PAR 5 DEVELOPMENT GROUP, LLC MAILING ADRESS 2075 JUNIPER LAKE ROAD CITY, STATE WEST END, NORTH CAROLINA 27376 PIN NUMBER 0521-50-7016 TOTAL LOT AREA 50,661 SF (1.16 AC) AREA TO BE DEVELOPED 50,661 SF (1.16 AC) PROPOSED ZONING LC EXISTING USE SINGLE FAMILY/VACANT PROPOSED USE RETAIL DISTURBED/DENUDED AREA 1.22 AC SETBACKS REQUIRED: FRONT 25 FT SIDE 3 FT/ 15 FT ABUTTING SINGLE FAMILY USE REAR 10 FT/ 20 FT ABUTTING SINGLE FAMILY USE OPEN SPACE: REQUIRED 5,066 SF PROPOSED (TOTAL) 5,327 SF USABLE 5,327 SF PARKING: REQUIRED (INCLUDING HANDICAP) 31 PROPOSED (INCLUDING HANDICAP) 31 PROPOSED HC SPACES 2 I I 3/8" �RB— — — 1" EIP 5/8" DEED SRB O EAI PP _SPEED SPEED BUMP BUMP 16'x16' (MIN.) CONCRETE -,.\ \\-, 18'x24' (MIN.) CONCRETE DUMPSTER PAD AREA FOR (2) STD. DUMPSTERS \ ECM 'O N 1 \_ TRUNC 6' SIDEWALK Di EASEMENT %HEAVY DUTY PAVEMENT _ (SHOWN SHADED) \ TBM: \ 4D COTTON SPINDLE #1 N: 509,923.954 TRUNCATED Z E: 2,025,619.859 DOMES (TYP) I RA ELEV: 262.15 ��N NC GRID NAD 83 3� (2011) EPK EPK ER' NAVD 88 _ O ENl'p� �C7 3/8" R=830.29'; O7� 3/8" ERB L=9.08' 3/8" ERB CHORD- ERB N87'37'50"W 9.08' HONEYCUTT ROAD - SR 1613 80' R/W (PUBLIC) JU JIFMVumrxu I.UKt3 6 CONCRETE CURB RELOCATE TELEPHON & GUTTER BOX / II I I II / err - UNNAMED 20' STREET PUMP E]_HOUSE o c,+ rn \ \ 8„ PINE PP /Z CONCRETE WHEEL STOPS\(TYP) LIGHTED PYLON SIGN W/ UNDERGROUND ELECTRICAL 3/8„ ERB i"W 171.31' 3/8„ ERB — SD 30" STANDARD we CONCRETE CURB 2' LAP JOINT. MILL & GUTTER TO A DEPTH OF 1.5" -m o W f \ n \ -- —� -- ECM 716°37'39"E 21.22' TIE�� \ \ \ \ \ t; w \N N. \ TEMPORARY \ DRAINAGE EASEMENT DB 4269, PG 75 \ o r— 378" 5/8" ERB SRB W8 — HONEYCUTT ROAD - SR 1613 95' R/W (PUBLIC) ® 8" HW 8" PINE i 30 6" HW d ; d • / j d • 4 • , A • d • • _ / _ A AA • a • f •d d • •d d • • \ • • • • • • • • •d • • • A • d GRAPHIC SCALE 0 15 30 60 120 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite.U2, Fayetteville, NC 28306 office 1 910-426-6777 fax 1910-426-5777 license number I C-2354 www.4Dsitesotutions.com REVISIONS ISSUED FOR CONSTRUCTION PROJECT NAME FAYETTEVILLE HONEYCUTT ROAD DOLLAR GENERAL SITE PLAN CLIENT PAR 5 DEVELOPMENT GROUP, LLC 2075 Juniper Lake Road West End, North Carolina 27376 Phone: (910) 944-0881 PROJECT INFORMATION DESIGNED BY: SCOTT DRAWN BY: SCOTT CHECKED BY: CHRIS PROJECT NUMBER: 1485 DRAWING SCALE HORIZONTAL: 1 "=30' DATE RELEASED MAY 4, 2020 SHEET NUMBER ( IN FEET ) 1 inch = 30 ft. C-200 VICINITY MAP NOT TO SCALE LEGEND: EAI O EAI-EXISTING ANGLE IRON ECM® ECM -EXISTING CONCRETE MONUMENT EIP Oo EIP-EXISTING IRON PIPE EIR Oo EIR-EXISTING IRON ROD EPKO EPK-EXISTING PK NAIL ENLO ENL-EXISTING NAIL ERBO ERB-EXISTING REBAR SRBO SRB-SET REBAR o COMPUTED POINT N/F - NOW OR FORMERLY R/W - RIGHT OF WAY POB - POINT OF BEGINNING POC - POINT OF COMMENCING PROPERTY LINE ADJACENT PROPERTY LINE TIE LINE RIGHT-OF-WAY SETBACK LINE SD STORM DRAINAGE W WATER LINE // OVERHEAD UILITY X FENCE LINE WOODEN FENCE PERMANENT EASEMENT TREE LINE 260 MAJOR CONTOUR 262 MINOR CONTOUR x 260.52' SPOT ELEVATION -0-BENCHMARK S-,GN SIGN EB ELECTRICAL BOX PP • UTILITY POLE C GUY WIRE ❑T TELEPHONE PEDESTAL FIRE HYDRANT ❑❑ WATER METER ® CATCH BASIN ® DROP INLET TREE 0 ASPHALT CONCRETE BUILDINGS SITE DATA DEVELOPER PAR 5 DEVELOPMENT GROUP, LLC MAILING ADRESS 2075 JUNIPER LAKE ROAD CITY, STATE WEST END, NORTH CAROLINA 27376 PIN NUMBER 0521-50-7016 TOTAL LOT AREA 50,661 SF (1.16 AC) AREA TO BE DEVELOPED 50,661 SF (1.16 AC) PROPOSED ZONING LC EXISTING USE SINGLE FAMILY/VACANT PROPOSED USE RETAIL DISTURBED/DENUDED AREA 1.22 AC SETBACKS REQUIRED: FRONT 25 FT SIDE 3 FT/ 15 FT ABUTTING SINGLE FAMILY USE REAR 10 FT/ 20 FT ABUTTING SINGLE FAMILY USE OPEN SPACE: REQUIRED 5,066 SF PROPOSED (TOTAL) 5,327 SF USABLE 5,327 SF PARKING: REQUIRED (INCLUDING HANDICAP) 31 PROPOSED (INCLUDING HANDICAP) 31 PROPOSED HC SPACES 2 I 3/8" ERB QTY.1 TYPE PLANTING SIZE MIN. HEIGHT SCIENTIFIC NAME CANOPY TREES 14 WILLOW OAK 2" CALIPER 8' QUERCUS PHELLOS 4 AMERICAN HOLLY N/A 6' ILEX OPACA UNDERSTORY TREES 6 FLOWERING DOGWOOD 1.5" CALIPER 8' CORNUS FLORIDA 4 JAPANESE CHERRY 1.5" CALIPER 8' PRUNUS SERRULATA SHRUBS 104 JAPANESE HOLLY 5 GAL. 18" ILEX CRENATA ® 50 NANDINA 2 GAL. 18" NANDINA DOMESTICA 35 CARISSA HOLLY 5 GAL. 24" ILEX CORNUTA 'CARISSA' 32 BRILLIANT CHOKEBERRY 2 GAL. 24" ARONIA ARBUTIFOLIA 'BRILLANTISSIMA' LANDSCAPING NOTES: 1. HEIGHT AND SPREAD OF TREE SPECIMEN SHALL MEET REQUIREMENTS OF THE AMERICAN ASSOCIATION OF NURSERYMEN, AMERICAN STANDARD FOR NURSERY STOCK. 2. SHRUBBERY IS TO BE PLANTED AT LEAST 30" FROM CURBING AND FROM END OF PARKING SPACES TO PREVENT DAMAGE FROM CAR OVERHANG. 3. SHRUBS INSTALLED AS VEHICULAR USE SCREENING ARE TO BE MAINTAINED AT A MIN. HEIGHT OF 36"; MIN. INSTALLATION HEIGHT IS 24". 4. SITE LIGHTING PLANS REQUIRE LIGHTS TO BE A MIN. OF 15 FEET FROM TREES. ANY ADJUSTMENTS IN THE FIELD NEED TO COMPLY WITH THIS STANDARD AND BE APPROVED BY CITY STAFF. 5. EACH TREE MUST BE PLANTED SUCH THAT THE ROOT FLARE IS VISIBLE AT THE TOP OF THE ROOT BALL. TREES WHERE THE ROOT FLARE IS NOT VISIBLE SHALL BE REJECTED. DO NOT COVER THE ROOT FLARE WITH MULCH. 6. DO NOT PLACE MULCH IN CONTACT WITH THE TREE TRUNK. KEEP MULCH A MIN. OF 4" AWAY FROM THE TRUNK BASE. 7. ANY CHANGES TO THE PROPOSED PLANT SCHEDULE MUST BE APPROVED BY THE DESIGNER OF RECORD AND THE CITY. IN CASES WHERE THE PLANT SCHEDULE ONLY INCLUDES THE PLANT TYPE AND DOES NOT INCLUDE THE PLANT SPECIES, THE CONTRACTOR SHALL BE REQUIRED TO SUBMIT TO THE CITY FOR APPROVAL, A DETAILED PLANT SCHEDULE AND ASSOCIATED PLANTING PLAN PREPARED BY A PROFESSIONAL KNOWLEDGEABLE ABOUT PLANT MATERIAL AND DESIGN, PRIOR TO PROCEEDING WITH INSTALLATION. *THIS LANDSCAPING PLAN IS THE MINIMUM REQUIRED TO MEET WITH THE CITY OF FAYETTEVILLE UDO. THE OWNER OR DEVELOPER IS ENCOURAGED TO CONSULT WITH A LANDSCAPE ARCHITECT IN ORDER TO DEVELOP A PLAN THAT IS MORE IN DEPTH THAN THE MINIMUM REQUIREMENTS. THIS PLAN IS FOR PERMITTING PURPOSES ONLY. 1,. ECM EIP — -- -- -- -- -- -- -- - —off--- -- -- -- -- -- -- � -- -- -- -- -- -•- -- - S16°37'39"E UNNAMED 20' STREET 21.22' TIE___� 5/8 SRB S87°49'57"E 200.00' TIE SRB - -- -- ; — -- -- -- — -- O 1 -- -- -- -- -- -- y ® N: 510,207.816 \ \�, � EIP (P ) \ � J cr_ Jm N � � n / 3/8" T ERB / 1 27 2 TBM: 4D COTTON SPINDLE #1 N: 509,923.954 a ? S E: 2,025,619.859 w ELEV: 262.15 �N NC GRID NAD 83 3L:� (2011) EPK EPK ER' NAVD 88 - O ���1�---- ENL'p� -.Cr 3/8" R=830.29': 3/8" ERB L=9.08' 3/8" ERB ERB CHORD- N87°37'50"W 9.08' ERB \ \ N \ J \ \ 25' STREETSCAPE \BUFFER d \CO 7 WB In rOD HONEY80 R/W (PSR 1613 UBUC) N 9 \ \ \ \ t; W \N I N. \ \ \ 3)8„ 5/8" ERB SRB HONEYCUTT ROAD - SR 1613 95' R/W (PUBLIC) 30 e d � d • d • / d e d • 4 • • , d f •d d e •d d • • \ • • • • • • • • • •d • • A • • d GRAPHIC SCALE 0 15 30 60 120 ■ sl e solutions civil engineering I land surveying 409 Chicago Drive, Suite.U2, Fayetteville, NC 28306 office 1 910-426-6777 fax 1910-426-5777 license number I C-2354 www.4Dsitesotutions.com ``�,`IICARO zZ// 2 : OF SS ..�L SEA IO2 NE .•: ja��� OTT REVISIONS ISSUED FOR CONSTRUCTION PROJECT NAME FAYETTEVILLE HONEYCUTT ROAD DOLLAR GENERAL LANDSCAPE PLAN CLIENT PAR 5 DEVELOPMENT GROUP, LLC 2075 Juniper Lake Road West End, North Carolina 27376 Phone: (910) 944-0881 PROJECT INFORMATION DESIGNED BY: SCOTT DRAWN BY: SCOTT CHECKED BY: CHRIS PROJECT NUMBER: 1485 DRAWING SCALE HORIZONTAL: 1 "=30' DATE RELEASED MAY 4, 2020 SHEET NUMBER ( IN FEET ) 1 inch = 30 ft. C-201 VICINITY MAP NOT TO SCALE LEGEND: EAI O EAI-EXISTING ANGLE IRON ECM® ECM -EXISTING CONCRETE MONUMENT EIP Oo EIP-EXISTING IRON PIPE EIR O EIR-EXISTING IRON ROD EPKO EPK-EXISTING PK NAIL ENLO ENL-EXISTING NAIL ERBO ERB-EXISTING REBAR SRBO SRB-SET REBAR o COMPUTED POINT N/F - NOW OR FORMERLY R/W - RIGHT OF WAY POB - POINT OF BEGINNING POC - POINT OF COMMENCING PROPERTY LINE ADJACENT PROPERTY LINE TIE LINE RIGHT-OF-WAY -SETBACK LINE SD STORM DRAINAGE W WATER LINE // OVERHEAD UILITY X FENCE LINE WOODEN FENCE PERMANENT EASEMENT TREE LINE 260 MAJOR CONTOUR 262 MINOR CONTOUR x 260.52' SPOT ELEVATION -0-BENCHMARK S-,GN SIGN EB ELECTRICAL BOX PP • UTILITY POLE C GUY WIRE ❑T TELEPHONE PEDESTAL FIRE HYDRANT ❑❑ WATER METER ® CATCH BASIN ® DROP INLET TREE 0 ASPHALT CONCRETE BUILDINGS I I 3/8" ERB 1" EIP 5/8" OEED , SRB UMP -- -- // -- PP //- - -- - _SPEED SPEED 263 BUMPO BUMP O -_ Al 3/8" 18" ERB �\ _ CEDAR SEPTIC FIELD, NO GRADING PERMITTED JB-7 IM \ EIP ECM 'O \ v NO N Z \ N \ \ / 3/8" \ / / ERB 0 25� \ \ C \ I \ \I\ I \ TBM: 4D COTTON SPINDLE #1 N: 509,923.954 \ E: 2, 025, 619.859 ELEV: 262.15 NC GRID NAD 83 NAVD 188 - - EPK OEPK �7 20" CEDAR Pp C ONC 20( P a o 1.�5 IN 262.09 61.�5 1 62.20 /, \ 1 261.60 261. 4 2.28 \ 261. 0 61.60 M20 TW 1. 0 19` 61.7 HW 1 1 261I.72 1 0 61.84 r Y 1 O � LL rn o 0 / tyn o ", 62. l /261.43 1 1 261 61 6 W 0 2E 1 \ ® 8" HW 8" PINE TWIN 267 30' n I PINES 1 HW \ ECM 7�77UNNAMED 20' STREET 5/8" _ SRB -- -- -- -- - --- -- o -- N: 510,207.816 1" EIP /- EIP I ® (PINCH TOP) E: 2,025,988.765 NC GRID NAD 83 / (2011) 3/8"/ PINE 3/8" ERB / 4' X SS ERB _/ HW 61.1 5" DI-6 262 261.8 \ PINE \ x INV 259.02 / 262.3 �, \ 258.9 N - 265 _ l � 1 10" CPP / ® 0 50% MIN x GRADING NOTES 1. ALL SPOT ELEVATIONS ARE TO THE FINISHED GRADE OF THE CURB, UNLESS OTHERWISE NOTED. 2. ALL SIDEWALKS AND PEDESTRIAN WALKING SURFACES SHALL HAVE A CROSS SLOPE NO STEEPER THAN 2% AND LONGITUDINAL SLOPE NO STEEPER THAN 5%. 3. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL LAND DISTURBING ACTIVITIES AND ENSURE COMPLIANCE WITH THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN. THE CONTRACTOR SHALL INSPECT AND MAINTAIN ALL EROSION CONTROL DEVICES AND CLEAR ANY DEBRIS LEAVING THE SITE ON NEIGHBORING ROADS. 4. EXISTING GROUND UPON WHICH FILL OR BASE IS TO BE PLACED SHALL BE CLEARED OF WEEDS, DEBRIS, TOPSOIL, AND ALL OTHER DELETERIOUS MATERIALS; NO FILL SHALL BE PLACED UNTIL PREPARATION OF THE EXISTING GROUND HAS BEEN COMPLETED 5. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR AND THE OWNER TO PROTECT ADJACENT PROPERTY, THE PUBLIC AND UTILITIES DURING GRADING OPERATIONS. THE CONTRACTOR ASSUMES ALL LIABILITY FOR THE UNDERGROUND UTILITY PIPES, CONDUITS, OR STRUCTURES, WHETHER SHOWN OR NOT ON THE PLAN 6. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION OF ALL UTILITIES OR STRUCTURES ABOVE AND BELOW GROUND, SHOWN OR NOT SHOWN ON THESE PLANS. THEY WILL BE HELD RESPONSIBLE FOR ALL DAMAGE TO ANY UTILITIES OR STRUCTURES CAUSED BY HIS OPERATION. 7. ALL CUT AND FILL SLOPES SHOULD BE INVESTIGATED BOTH DURING AND AFTER GRADING BY THE CONTRACTOR TO DETERMINE IF ANY SLOPE STABILITY PROBLEMS EXIST. IF IT IS DETERMINED THAT THERE IS A SLOPE STABILITY PROBLEM THE ENGINEER OF RECORD SHOULD BE NOTIFIED. 8. STOCKPILE AREAS THAT WILL EXCEED 10' IN HEIGHT SHOULD BE GRADED WITH 3:1 SLOPES AND SURROUNDED BY SILT FENCE. 9. APPROVED COPIES OF THE GRADING AND EROSION CONTROL PLANS SHALL BE ON THE PERMITTED SITE WHILE WORK IS IN PROGRESS. 10. ALL EXISTING DRAINAGE COURSES THROUGH THIS SITE SHALL REMAIN IN A CONDITION SUCH THAT THEY CAN TRANSPORT THE NATURAL DRAINAGE UNTIL FACILITIES TO HANDLE THE STORM WATER ARE CONSTRUCTED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE DUE TO OBSTRUCTING NATURAL DRAINAGE PATTERNS. 11. ANY DEVIATION FROM THE APPROVED GRADING PLAN SHOULD BE REPORTED TO THE ENGINEER OF RECORD PRIOR TO IMPLEMENTATION OF THE CHANGE. 12. ALL SLOPES 3:1 OR STEEPER THAT EXTEND TEN FEET OR MORE SHALL BE LINED WITH NORTH AMERICAN GREEN S75 TEMPORARY EROSION CONTROL BLANKET OR EQUAL SUBSTITUTE. 13. STORM PIPE DISTANCES SHOWN ARE TO THE CENTER OF THE BOX FOR ALL STRUCTURES UNLESS OTHERWISE NOTED. 14. CONTRACTOR SHALL VERIFY LOCATIONS OF DOWNSPOUTS USING THE ARCHITECTURAL PLANS PRIOR TO CONSTRUCTION. PROPOSED , \ - 264 BUILDING (130'x70') 261.E 1" 1„ EIP / ° a s, . 9,100 SIF O EIP (PINCH TOP) CARPORT • 4 ' 1"EIP 'd •° FFE: 262.35'\ 3/8" (PINCH TOP) ERB EIP ° ;° °, %° °:\ .. • O ERB X O \ - 3 5/8» - / SRB E ERB ERB 2, / - _` E: 2,026,0 21843 NC GRID NAD 83 \ / / 262 \ (2011) \ - �,q - 1 HW \ c \ 28, E� _^ PUMP LL�� \ WELL!�r 261.85 HOUSE /. NV 259.68 262.35 I\ \ \ 262.21 261,71 2. \ NOTE: ALL PIPE JOINTS BELOW THE STORM \ \ �g TW WATER UNDERGROUND RETENTION 10 YR i2.35 • HIGH WATER ELEVATION SHALL HAVE RUBBER 2.21TW/E \ GASKET JOINTS THAT CONFORM TO ASTM C 443 \ \ • 2 1.56 / yy21 6 21 261.48 PERMANENT UNDERGROUND RETENTION � - 261 - 61. 9 TW/EP ` `` \ INVERT OF SYSTEM: 251.40' \ \ \ 61.79 l 61.86� INVERT OF PIPES: 251.73' TORM EELEV: \ 26, .53 V \ 261.15 10YYRSSTORM 255 6' \ \ \ 61.86 i LP � \ \ / OUTER HOPE, 6LP1061.27 iP PERFORAjED DI -3 260 - - / 261.48 I \ / \ ®0 Op% 24 / / 61.55 / �F \ DI-2i p j 1N�ENANCE __HP BOUNDARY P \ PINE / M EpSEMEi OF STONE \ \ 2 .57 60.42 / 260.99\ 261.19 63.71 LF ® 1.73% 15" RCP 61.71 / LP \ \ -J 260.73 261. 9 �® fin 96 HP_ j 260 \ TEMPORARY \ I 261.5 ® / DRAINAGE 261 REMOVE DI #8146 & EASEMENT 15" RCP 26.62 LF ® 1.50% \ 260 1 DB 4269, PG 75 DI-5 __e DI #8i., 15" RCP DI #8517 DI #8525 ° GRATE 25 --• THE L IS \ GRATE 258.81 GRATE 258.90 \ " OUT - R ER INV OUT 253.74 INV OUT 253.821 3/81, [ ED] F W ERB 00 - - - Eot ERB SRB I N E _ _ / u •ERB SD SD - 3/8 O/� 3/8" ERB 61.67 CI'#8208 60.04 3/g ERB HOOD 260.66 \\\ Wg W8 ERB - W8 W8 - W8 _ we W8 II INV IN 255.95 (8146) CONVERT TO HONEYCUTT ROAD - SR 1613 HONEYCUTT ROAD - SR 103 80' R/W (PUBLIC) 4F DI-1 IS'. 260.97 '�c'Oos89 0 260.97 1 \ 61.02 259.86 261. 1-\ � II1 N 61.41� �61.20 8 RB ENL ERB -INV IN 250.50 (8271) JUNCTION BOX INV OUT 250.50 RIM: 260.22' Ckf N -m I II / 0 f CI #8271 HOOD 259.28 - - - - INV OUT 250.85 95' R/W (PUBLIC) DI #8514 GRATE 258.38 INV OUT 253.16 00 v CI #8273 HOOD 258.63 s _INV IN 252.77 (8514) - INV IN 249.41 (8208) INV OUT 249.40 Know what's below. Call before you dig. GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. THE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 A MINIMUM OF 72 HOURS PRIOR TO DIGGING IN ORDER TO HAVE THE EXISTING UTILITIES LOCATED 120 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite 112, Fayetteville, NC 28306 office 1 910-426-6777 fax 1910-426-5777 license number I C-2354 www.4Dsitesotutions.com ``�y\ \ICARO,�% 2 : OF SS ..�L SEA02 _ G I NE .•:���� ''';/ ,O REVISIONS ISSUED FOR CONSTRUCTION PROJECT NAM FAYETTEVILLE HONEYCUTT ROAD DOLLAR GENERAL GRADING PLAN CLIENT PAR 5 DEVELOPMENT GROUP, LLC 2075 Juniper Lake Road West End, North Carolina 27376 Phone: (910) 944-0881 PROJECT INFORMATION DESIGNED BY: SCOTT DRAWN BY: SCOTT CHECKED BY: CHRIS PROJECT NUMBER: 1485 DRAWING SCALE HORIZONTAL: 1 "=30' DATE RELEASED MAY 4, 2020 SHEET NUMBER C-3nO VICINITY MAP NOT TO SCALE EROSION CONTROL NOTES 1. ALL INLET/OUTLET PROTECTION WILL BE CHECKED FOR MAINTENANCE AND FAILURE EACH ACTIVE DAY ON SITE. SEDIMENT WILL BE REMOVED FROM THE SEDIMENT TRAP AND INLET PROTECTION DEVICES WHEN THE STORAGE CAPACITY HAS BEEN APPROXIMATELY 50% FILLED. GRAVEL WILL BE CLEANED OR REPLACED WHEN THE SEDIMENT POOL NO LONGER DRAINS PROPERLY. SEDIMENT WILL BE REMOVED FROM BEHIND THE SEDIMENT FENCE WHEN IT BECOMES ABOUT 0.5' DEEP AT THE FENCE. THE SEDIMENT FENCE WILL BE REPAIRED AS NEEDED TO MAINTAIN A PROPER BARRIER. 2. TEMPORARY EROSION CONTROL FACILITIES AND/OR PERMANENT FACILITIES INTENDED TO CONTROL EROSION OF AND EARTH DISTURBANCE OPERATION SHALL BE INSTALLED BEFORE ANY EARTH DISTURBANCE OPERATIONS TAKE PLACE OR AT THE EARLIEST POSSIBLE POINT DURING CONSTRUCTION. 3. TEMPORARY & PERMANENT EROSION CONTROL MEASURES SHALL BE CONSTRUCTED PER THE DETAILS HEREIN, OR SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. 4. THE CONTRACTOR MUST NOTIFY THE APPROPRIATE NCDEQ OFFICE A MINIMUM OF 48 HOURS PRIOR TO BEGINNING ANY LAND DISTURBING ACTIVITIES. 910-433-3300 5. REMOVE ALL SOILS AND SEDIMENTS TRACKED OR OTHERWISE DEPOSITED ONTO PUBLIC AND PRIVATE PAVEMENT AREAS. REMOVAL SHALL BE ON A DAILY BASIS WHEN TRACKING OCCURS. 6. LOCATE SOIL STOCKPILES NO LESS THAN TWENTY-FIVE (25) FEET FROM ANY PUBLIC OR PRIVATE ROADWAY OR DRAINAGE CHANNEL. IF REMAINING FOR MORE THAN SEVEN DAYS, STABILIZE THE STOCKPILES BY VEGETATIVE COVER, TARPS, OR OTHER MEANS. CONTROL EROSION FROM ALL STOCKPILES BY PLACING SILT BARRIERS AROUND THE PILES. TEMPORARY STOCKPILES LOCATED ON PAVED SURFACES MUST BE NO LESS THAN FIVE FEET FROM THE DRAINAGE/GUTTER LINE AND SHALL BE COVERED IF LEFT MORE THAN 24 HOURS. 7. MAINTAIN ALL TEMPORARY EROSION AND SEDIMENT CONTROL DEVICES IN PLACE UNTIL THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED. INSPECT TEMPORARY EROSION AND SEDIMENT CONTROL DEVICES ON A DAILY BASIS AND REPLACE DETERIORATED, DAMAGED, OR ROTTED EROSION CONTROL DEVICES IMMEDIATELY. 8. TEMPORARILY OR PERMANENTLY STABILIZE ALL DENUDED AREAS WHICH HAVE BEEN FINISH GRADED, AND ALL DENUDED AREAS IN WHICH GRADING OR SITE BUILDING CONSTRUCTION OPERATIONS ARE NOT ACTIVELY UNDERWAY AGAINST EROSION DUE TO RAIN, WIND AND RUNNING WATER WITHIN 14 DAYS. USE SEEDING AND MULCHING, EROSION CONTROL MATTING, AND/OR SODDING AND STAKING IN GREEN SPACE AREAS AND OTHERWISE APPROPRIATE MEASURES. USE EARLY APPLICATION OF GRAVEL BASE ON AREAS TO BE PAVED. 9. DO NOT REMOVE ANY EROSION AND SEDIMENT CONTROL DEVICES AFTER THE PROTECTED AREA HAS UNDERGONE FINAL STABILIZATION AND PERMANENT VEGETATION HAS BEEN ESTABLISHED, IT IS RECOMMENDED THAT NCDEQ APPROVE THE ACTION PRIOR TO REMOVAL. 10. THE CONSTRUCTION ENTRANCE SHALL BE INSTALLED CONCURRENTLY WITH THE INITIATION OF CONSTRUCTION ACTIVITY. 11. THE INSTALLATION OF EROSION CONTROL MEASURES SHALL TAKE PRECEDENCE OVER ALL OTHER CONSTRUCTION ACTIVITIES. 12. THE PERMITTEE SHALL BE HELD RESPONSIBLE FOR THE ACTIONS AND PERFORMANCE OF ANY OTHER PARTIES PERFORMING WORK ON THIS PROJECT. 13. ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS WILL BE MADE IMMEDIATELY TO MAINTAIN ALL PRACTICES AS DESIGNED. 14. PURSUANT TO G.S. 113A-57(2), THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OR OTHER ADEQUATE EROSION CONTROL DEVICES OR STRUCTURES. IN ANY EVENT, SLOPES LEFT EXPOSED WILL, WITHIN 7 OR 14 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY OR PERMANENT GROUND COVER, DEVICES OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION. PURSUANT TO G.S. 113A-57(3), PROVISIONS FOR PERMANENT GROUND COVER SUFFICIENT TO RETAIN EROSION MUST BE ACCOMPLISHED FOR ALL DISTURBED AREAS WITHIN 14 WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION DEVELOPMENT. 15. CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL EROSION CONTROL MEASURES SHOWN AND ANY ADDITIONAL MEASURES REQUIRED TO CONTROL THE SEDIMENT DURING THE COURSE OF CONSTRUCTION. 16. ALL SEEDED AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED ACCORDING TO THE DETAILS HEREIN. 17. THE CONTACT PERSON FOR EROSION CONTROL ISSUES THAT ARISE ON SITE IS JODY BLAND. CONTACT 910-944-0881. CONSTRUCTION SEQUENCE 1. OBTAIN ALL NECESSARY PERMITS AND APPROVALS AND HOLD PRE CONSTRUCTION CONFERENCE. 2. INSTALL STONE CONSTRUCTION ENTRANCE AND TEMPORARY SILT FENCE WHERE SPECIFIED. 3. CLEAR AND GRUB THE SITE AS NEEDED. 4. ROUGH GRADE THE SITE AND APPLY TEMPORARY SEEDING TO AREAS TO REMAIN GRASSED. 5. INSTALL UTILITIES. 6. INSTALL INLET PROTECTION ON ALL NEW STORM WATER INLETS. 7. PERFORM FINE GRADING. 8. INSTALL AND PREPARE BASE COURSE. 9. PAVE ROADWAYS AND PARKING LOTS. 10. FERTILIZE, SEED AND MULCH ALL REMAINING DISTURBED AREAS. 11. UPON SITE STABILIZATION, SEEK NCDEQ APPROVAL TO REMOVE ALL TEMPORARY MEASURES. 12. ALL EROSION CONTROL MEASURES SHALL BE MAINTAINED AS OUTLINED IN THE DETAILS WITHIN THE PLANS AND ACCORDING TO THE NCDEQ EROSION CONTROL MANUAL. I I 3/8" ERB �Nl11yN7_�INP►ti]�KiPul:3hhl�>�9���R�P►I�C�I:�n[e1_1�1�>�9���1�6y�XilINP►��i]:��F THE SEDIMENTATION POLLUTION CONTROL ACT WAS AMENDED IN 2006 TO REQUIRE THAT PERSONS RESPONSIBLE FOR LAND -DISTURBING ACTIVITIES INSPECT A PROJECT AFTER EACH PHASE OF THE PROJECT TO MAKE SURE THAT THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN IS BEING FOLLOWED. RULES DETAILING THE DOCUMENTATION OF THESE INSPECTIONS TOOK EFFECT OCTOBER 1, 2010. TO SIMPLIFY DOCUMENTATION OF SELF -INSPECTION REPORTS AND NPDES SELF -MONITORING REPORTS, DWQ AND DEMLR DEVELOPED A COMBINED FORM. THE FOCUS OF THE SELF -INSPECTION REPORT IS THE INSTALLATION AND MAINTENANCE OF EROSION AND SEDIMENTATION CONTROL MEASURES ACCORDING TO THE APPROVED PLAN. THE INSPECTIONS SHOULD BE CONDUCTED AFTER EACH PHASE OF THE PROJECT, AND CONTINUED UNTIL PERMANENT GROUND COVER IS ESTABLISHED. THE FORM CAN BE ACCESSED AT: HTTP: //PORTAL.NCDENR.ORG/WEB/LR/EROSION IF YOU HAVE QUESTIONS OR CANNOT ACCESS THE FORM, PLEASE CONTACT THE FAYETTEVILLE REGIONAL OFFICE AT (910) 433-3300. 1" EIP 5/8" -EED , \ SRB� ' s \ ® 8- HW 8" PINE TWIN 267 - 30' n I PINES 9 \ 6" n 1 HW \ ECM PP _SPEED SPEED zss - , UNNAMED 20' STREET BUMPO BUMP O 5/8" - - - - - - - - SRB -- � -- -- -- - -- -- -- --_ o N: 510,207.816 1" EIP / �7 20"4 /EIP �% ® NC GRID NAD 783 (PINCH TOP) EAI �i 16' - CEDAR / ERB �\ _ CEDAR 3/8"/ PINE (2011) -71 U PP ON 3/8° ERB / 4• � X O ERB / HW DI-6 2' \ 5" 6 PINE \ \ X SEPTIC FIELD. NO GRADING \ / \ PERMITTED u 1 265 w JB-7 \ 2s, - l \ \LIMITS OF CONSTRUCTION / I 1.2 AC \ \ / \ x LEGEND: EAI O EAI-EXISTING ANGLE IRON ECM® ECM -EXISTING CONCRETE MONUMENT EIP (0EIP-EXISTING IRON PIPE EIR Oo EIR-EXISTING IRON ROD EPKO EPK-EXISTING PK NAIL ENI_O ENL-EXISTING NAIL ERGO ERB-EXISTING REBAR SRBO SRB-SET REBAR o COMPUTED POINT N/F - NOW OR FORMERLY R/W - RIGHT OF WAY POB - POINT OF BEGINNING POC - POINT OF COMMENCING PROPERTY LINE ADJACENT PROPERTY LINE TIE LINE RIGHT-OF-WAY SETBACK LINE SD STORM DRAINAGE W WATER LINE // OVERHEAD UILITY X FENCE LINE ❑ ❑ WOODEN FENCE PERMANENT EASEMENT TREE LINE 260 MAJOR CONTOUR 262 MINOR CONTOUR x 260.52' SPOT ELEVATION BENCHMARK S-'GN SIGN ES ELECTRICAL BOX PP UTILITY POLE C• GUY WIRE ❑T TELEPHONE PEDESTAL FIRE HYDRANT L�J WATER METER ® CATCH BASIN ® DROP INLET TREE ASPHALT CONCRETE 0 BUILDINGS PROPOSED , - 264 BUILDING ��� \ / a •/ ° \ 19' I (130'X70') `\ EIP 1„ EIPA ♦ ° 1' \ HW EI ECM 'O \ �q Nti- N TEMPORARY SILT, FENCE (TYP) J / „ 3/8 / y / ERB 0 / IU o \ r \ C \ 1 \ I \ I\ TBM: 4D COTTON SPINDLE #1 N: 509,923.954 \ E: 2, 025, 619.859 ELEV: 262.15 \ c NC GRID NAD 83 - NAVD 188 EPK OEPK 3//8 3/8" ERB 3/8" ERB ERB HONEYCUTT ROAD - SR 1613 80' R/W (PUBLIC) 9,100 SF FFE: 262.35'. I i IL I / \ (PINCH TOP) l/y 1"ERE EIP 5/8 3/8" (PINCH TOP) ERB 3 5/8 - 3/8„ / SRB E ERB 2 \ / / 262 - \ _ 12" / HW WELL. d ° , • I • ♦ • • •d d • / d , d / DI-1 DI-2 p / N _TEMPORARY INLET 1 \ \ � PROTECTION (TYP) ERB 1-3 \ / \ �a� I,w 3S N 2E DI-5 SF PINE \ 3/8„ ERB i \ 26, \ - 261 - 259 \ - SD \ / 260 - - X \ TEMPORARY \ DRAINAGE EASEMENT \ DB 4269, PG 75 DI #8517 DI #8525 ° GRATE 258.81 GRATE 258.90 \ INV OUT 253.74 INV OUT 253.82 Lj 1 - �E �8 5/8- - - - - ERB SRB M SD - 8208CI5#260.66 w8I HOOD � V8 W8 INV IN 2.)(8 INV N 250.50 (8271) INV OUT 250.50 TEMPORARY CONSTRUCTION N ENTRANCE N 0 f CI #8271 HOOD 259.28 - - - - INV OUT 250.85 CARPORT A A A A A A / • ' / / • • • J • • • • ♦ d . a •d • a EIP / d •d • d • : d • di\ •. .. . .. • _.� • • A • • d -- O N: 510,092.189 E: 2,026,012.543 \ NC GRID NAD 83 (2011) \ \ \ \ \ \ HONEYCUTT ROAD - SR 1613 95' R/W (PUBLIC) DI #8514 GRATE 258.38 INV OUT 253.16 A v CI #8273 HOOD 258.63 _INV IN 252.77 (8514) INV IN 249.41 (8208) INV OUT 249.40 GROUND STABILIZATION CHART SITE AREA STABILIZATION STABILIZATION TIME DESCRIPTION TIME FRAME FRAME EXCEPTIONS PERIMETER DIKES, SWALES, DITHCES 7 DAYS NONE AND SLOPES HIGH QUALITY WATER (HQW) 7 DAYS NONE ZONES IF SLOPES ARE 10' OR SLOPES STEEPER 7 DAYS LESS IN LENGTH AND ARE THAN 3:1 NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED SLOPES 3:1 OR 7-DAYS FOR SLOPES FLATTER 14 DAYS GREATER THAN 50 FEET IN LENGTH NONE ALL OTHER AREAS (EXCEPT FOR WITH SLOPES FLATTER 14 DAYS PERIMETERS AND THAN 4:1 HQW ZONES) Know what's below. CaII before you dig. GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. THE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 A MINIMUM OF 72 HOURS PRIOR TO DIGGING IN ORDER TO HAVE THE EXISTING UTILITIES LOCATED 120 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite.U2, Fayetteville, NC 28306 office 1910-426-6777 fax 1910-426-5777 license number I C-2354 www.4Dsitesolutions.com ``�y\\ICARO z/,, � 2 -. 0 SS 4� SEA 02 G I NE .•: ja��� �O 05"- REVISIONS ISSUED FOR CONSTRUCTION PROJECT NAM FAYETTEVILLE HONEYCUTT ROAD DOLLAR GENERAL EROSION CONTROL PLAN CLIENT PAR 5 DEVELOPMENT GROUP, LLC 2075 Juniper Lake Road West End, North Carolina 27376 Phone: (910) 944-0881 PROJECT INFORMATION DESIGNED BY: SCOTT DRAWN BY: SCOTT CHECKED BY: CHRIS PROJECT NUMBER: 1485 DRAWING SCALE HORIZONTAL: 1 "=30' DATE RELEASED MAY 4, 2020 SHEET NUMBER C-400 VICINITY MAP NOT TO SCALE LEGEND: EAI O EAI-EXISTING ANGLE IRON ECM® ECM -EXISTING CONCRETE MONUMENT EIP OO EIP-EXISTING IRON PIPE EIR OO EIR-EXISTING IRON ROD EPKO EPK-EXISTING PK NAIL ENLO ENL-EXISTING NAIL ERB O ERB-EXISTING REBAR SRB 0 SRB-SET REBAR o COMPUTED POINT N/F - NOW OR FORMERLY R/W - RIGHT OF WAY POB - POINT OF BEGINNING POC - POINT OF COMMENCING PROPERTY LINE — ADJACENT PROPERTY LINE TIE LINE RIGHT-OF-WAY -SETBACK LINE sD STORM DRAINAGE w WATER LINE OVERHEAD UILITY 275 270 265 260 255 250 245 UTILITY NOTES 1. THE CONTRACTOR SHALL MAINTAIN A SET OF RED LINE AS-BUILTS DURING THE CONSTRUCTION OF THE WATER LINE. ALL DEVIATIONS FROM THE PLAN SHALL BE NOTED ON THE AS -BUILT DRAWINGS. ALL VALVES AND CHANGE IN DIRECTION OF THE WATER LINE SHALL BE LOCATED WITH A MINIMUM OF TWO DISTANCES FROM A KNOWN OBJECT. THE CONTRACTOR WILL PROVIDE THE AS -BUILT DRAWINGS TO THE OWNER TO BE USED FOR THE WATER LINE CERTIFICATION AT THE COMPLETION OF THE PROJECT. 2. HORIZONTAL DIMENSIONS GIVEN FOR UNDERGROUND UTILITY TIES ARE APPROXIMATE UNLESS OTHERWISE NOTED. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL UTILITY COMPANIES AFFECTED BY THE PROPOSED WORK. 4. THE GENERAL CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS TO COMPLETE THE PROPOSED WORK, AND SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL REGULATIONS 5. MINIMUM SEPARATION BETWEEN SEWER (STORM OR SANITARY) AND WATER LINES SHALL BE 10' HORIZONTAL OR 18" VERTICAL UNLESS NOTED OTHERWISE. MINIMUM VERTICAL SEPARATION BETWEEN SANITARY SEWER AND STORM SEWER SHALL BE 24" UNLESS NOTED OTHERWISE. 6. ALL MATERIALS SHALL BE APPROVED BY PWC BEFORE INSTALLATION. 7. EXISTING UTILITIES NOT FOUND IN THE FIELD DURING SURVEY MAY REQUIRE DEMOLITION. 8. ALL ELEVATIONS ARE IN NAVD 88 DATUM. X FENCE LINE I WOODEN FENCE PERMANENT EASEMENT I TREE LINE 3/8" 260 MAJOR CONTOUR 1 ERB 262 MINOR CONTOUR x 260.52' SPOT ELEVATION -0-BENCHMARK S-'GN SIGN EB ELECTRICAL BOX PP• UTILITY POLE C GUY WIRE ❑T TELEPHONE PEDESTAL � FIRE HYDRANT LN WATER METER ® CATCH BASIN ® DROP INLET TREE 0 ASPHALT CONCRETE 0 BUILDINGS WATERLINE WATER MAIN —0+50 TO 1 +00 I� I� IZ to N o X 0' w D- 1 1 1 OD I 00 �J l 42" MINIMUM COVER 8" APPROX. LOCATION EXISTING 8" DI IWIN RJDI 1" PE WATER MAIN Nrn 1� a + _ + 00 O LL O r U1 0 a c0 Z1`1 N cd — X + wo - - - -EXISTING GROUND FINISHED GROUND 0 N 275 270 265 260 255 250 245 1" EIP 5/8" -EED , SRB UMP Al -- -- // -- — PP //— -- _SPEED SPEED zss BUMPO BUMP 3/8' 16 ERB �\ _ CEDAR \ EIP ECM 'O — � r NO N Z \ N \ 1 / 3/8„ \ / / ERB % \ r \ C \ I \ \I \ I\ SEPTIC FIELD 7 \ \ \ ® 8" HW a" PINE TWIN 267 30' n I PINES 8 \ 6" \ HW ECM 1/= S16°37'39'E zsq \ UNNAMED 20' STREET 21.22' TIE�� 5/8" SRB S87°49'57"E 200.00' TIE O 1„ 1" EIP 4" SEWER TO EIP ) �y ® ® N: ,025,9 8.76 (PINCH) / E: 2, 025, 988.765 SEPTIC FIELD NC GRID NAD 83 (2011) 3/8"/ PINE PP CONC 3/8' ERB / 4• X �\ PAD— SS ERB � � HW nrii \ � DI-6 5" PINE HW \ N \ O \ \ 265 / J I / o / 20„ CEDAR I'57"W 192.00' UTILITY CONSTRUCTION NOTES: 1. ALL WATER MAINS, LATERALS AND APPURTENANCES SHALL BE INSTALLED AND TESTED IN ACCORDANCE WITH FAYETTEVILLE PWC STANDARDS. 2. ALL SEWER MAINS, LATERALS, AND APPURTENANCES SHALL BE INSTALLED AND TESTED IN ACCORDANCE WITH FAYETTEVILLE PWC STANDARDS. 3. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH FAYETTEVILLE PWC STANDARDS. 4. CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF EXISTING UTILITIES PRIOR TO CONSTRUCTION. 5. CONTRACTOR SHALL PROVIDE A MINIMUM OF 48 HOURS NOTICE FOR ALL WATER OUTAGES. 6. CONSTRUCTION STAKING IS REQUIRED FOR ALL PWC WATER AND SEWER UTILITY INSTALLATIONS. CUT SHEETS, SIGNED AND SEALED BY A NC PLS, SHALL BE PROVIDED TO THE PWC WATER RESOURCES ENGINEERING DEPARTMENT AND THE CONTRACTOR IN ADVANCE OF CONSTRUCTION FOR PWC WATER AND SEWER UTILITIES. 7. CONTRACTOR SHALL MAINTAIN A COPY OF THE SIGNED AND SEALED CUT SHEET ON THE JOB SITE. CONSTRUCTION ON PWC WATER AND SEWER UTILITIES CANNOT BEGIN UNTIL THE CONTACTOR POSSESSES, ON SITE, A SIGNED AND SEALED CUT SHEET FROM THE PROFESSIONAL LAND SURVEYOR. 8. ALL NEW WATER AND SEWER MAINS, LATERALS, AND APPURTENANCES SHALL BE TESTED AND/OR DISINFECTED IN ACCORDANCE WITH FAYETTEVILLE PWC STANDARDS PRIOR TO PLACING INTO SERVICE. 9. CONTRACTOR SHALL COORDINATE TESTING AND INSPECTION WITH THE FAYETTEVILLE PWC PROJECT COORDINATOR. 10. ALL DUCTILE IRON PIPE IN SANITARY SEWER SERVICE SHALL HAVE AN INTERIOR LINING OF PROTECTO 401 OR APPROVED EQUAL. 11. ALL NEW MANHOLES ARE TO BE VACUUM -TESTED IN ACCORDANCE WITH FAYETTEVILLE PWC STANDARDS. 12. CONTRACTOR SHALL ABANDON ('KILL -OUT") ANY EXISTING WATER SERVICES THAT WILL NOT BE UTILIZED BY CUTTING THE SERVICE AT THE MAIN, PLUGGING THE CORPORATION, AND TURNING OFF THE CORPORATION. AT THE METER BOX, THE ABANDONED SERVICE IS TO BE CUT OR CRIMPED, AND BURIED A MINIMUM OF 3 FEET BELOW GRADE. 13. CONTRACTOR SHALL ABANDON ('KILL -OUT') ANY EXISTING SEWER SERVICES THAT WILL NOT BE UTILIZED BY UNCOVERING THE EXISTING LATERAL AT THE MAIN, CUT AND PLUG AT BOTH ENDS, REMOVE THE EXISTING CLEANOUT AND COMBINATION, AND PLUG THE TAP OR TEE AT THE MAIN. FOR LATERALS THAT CONNECT TO A MANHOLE AND ARE TO BE ABANDONED ('KILLED -OUT'), THE LATERAL SHALL BE REMOVED FROM THE MANHOLE AND THE REMAINING VOID IN THE MANHOLE SHALL BE FILLED WITH BLOCK AND MORTAR. 14. ALL EXISTING UTILITIES IMPACTED BY CONSTRUCTION SHALL BE ADJUSTED TO FINISHED GRADE IN ACCORDANCE WITH PWC REQUIREMENTS. ; G PROPOSED , \ - 264 / BUILDING a I (130'x70') EIP 1 EIP •� a s ° H 9,100 SF ` p (PINCH TOP) CARPORT Hw 1 •� � I N87°49'57"W 5/8„ / / ' • FFE: 262.35' . 1 "EIP •" 12.00' 3/8" (PINCH TOP) ERB / 1" 'd °, .a I I — EIP \ p ERB X O 1 3 5/8» — 92189 DI-1 I TBM: 4D COTTON SPINDLE #1 N: 509,923.954 \ ? E: 2, 025, 619.859 ELEV: 262.15 NC GRID NAD 83 (2011) NAVD 88 3/8" O7� 3/8" ERB 3/8" ERB ERB Know what's below. Call before you dig. HONEYCUTT ROAD - SR 1613 80' R/W (PUBLIC) _LA —tZ 3 t3I )K OEPK ER, � ENl'p� R=830.29': L=9.08' CHORD- N87°37'50"W 9.08' I / DI-2 I 1 I 5'X25' PWC EASEMENT 3/8 / SRB N E ERB 2,026,012.543 — 2, E NC GRIDNAD83 262 \ _ 12" \ HW E� _^ PUMP WELL. \ �� HOUSE \ \ \ r 260 T \� T \ 259 1N1EN PLACE rn / / MEASEMENT DI- \ \ N260 GF'8. \ / G)`. PP PINE / X / RPZ \ � / BACKFLOW N ® "ADDITIONAL EXISTING WATER REMOVE & REPLACE ® 2-�" RPZ METERS/LATERALS FOUND ON THIS PROPERTY SHALL BE KILLED TEMPORARY DRAINAGE \ FIRE HYDRANT BACKFLOW OUT AT THE MAIN IN EASEMENT T6" RJDI-----w- EXIST`__V_ ERB 6" GV i„ WM ACCORDANCE WITH PWC DB 4269, PG 75 \ DI-5 REQUIREMENTS. " I THE LE IS \ \ THE RNER I 5/8— — ERB SRB — — — — — 1 — — ERB N87°19'02"W 171.31' - -3/8" _____ ERB ID 9.5 LF OPEN CUT & PATCH w8 w8 )l 3' WIDE w� wa W8_ HONEYCUTT ROAD - SR 1613 — RENEW 1" LATERAL 95' R/W (PUBLIC) BACK TO MAIN / 0 *EXISTING FIRE HYDRANT TO BE REMOVED AND REPLACED. RETURN EXISTING HYDRANT TO PWC. o N � 30 GRAPHIC SCALE 0 15 30 60 120 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite 112, Fayetteville, NC 28306 office 1 910-426-6777 fax 1910-426-5777 license number I C-2354 www.4Dsitesotutions.com �y\ CARo ����' 2 40 SEA 02 G IN .•: ja�`� �O 050- 04/-.20 REVISIONS ISSUED FOR CONSTRUCTION PROJECT NAME FAYETTEVILLE HONEYCUTT ROAD DOLLAR GENERAL UTILITY PLAN PIN# 0521-50-7016 CLIENT PAR 5 DEVELOPMENT GROUP, LLC 2075 Juniper Lake Road West End, North Carolina 27376 Phone:(910)944-0881 PROJECT INFORMATION DESIGNED BY: SCOTT DRAWN BY: SCOTT CHECKED BY: CHRIS PROJECT NUMBER: 1485 DRAWING SCALE HORIZONTAL: 1 "=30' DATE RELEASED MAY 4, 2020 SHEET NUMBER 0+00 1+00 ( IN FEET ) 1 inch = 30 ft. THE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 A MINIMUM OF 72 HOURS PRIOR TO DIGGING IN ORDER TO HAVE THE EXISTING UTILITIES LOCATED C-500 270 265 260 255 250 245 240 \ we \ w8 106.43 Mf E DI-1 TO DI-2 STORM DRAIN -0+50 TO 1 +00 ^ n I N n O p0 O ^ n mc0 O(OOUI Z N01 u1 ONN N F-� O N N N 6HZZ (O Oa ON oD < M H0 +Q�»>� Z Z Z I O< p N U N +<> 0OOz FINISHED GRADE — — GRADE EXISTING 51.37 IF ® 0.587. 15" RCP o � (D N O O N 0 CD N 270 275 265 270 260 265 255 260 250 255 245 250 240 245 NC CRID NAD 83 (,,off) u z a �• - U10_ LO j263 ---_ ? 62 — nC J tf) z tiJrY W W� �io2 �w 1 Mw a ZZ^ o a \ 1 Cco _ CIV O O N I— N O 26.62 LF ® 1.50% W O N ? 15" RCP �Z U aS � I J N 3 (p W = N =2 7n d- 63.71 LF ®1.73% 15" RCP l� ~ i �.- �,0 b > a / V !�V Q 00� O Q \ Q O V �2zo 1� o W V h' ~ '>- \ I-6 < I 00 I S \ 0 ,� �► w I \ \ N e ' Iw I 1 3 o ZZ I o II ® wUj Fw _183.24 LF 0 0.00% 24" PERFORATED HDPE Z 'moo g m w W / MAINTENANCE EASEMENT/ lot 261 u� CO J Z Q < w to I� o 0 ® GQ .61 L_ 260 1 DI-6 TO CI #8208 STORM DRAIN -0+50 TO 5+00 love 1 3I II m ' I Z Cr r] N (a I INcrI O ON NO Om 00 00 O O��^ F,NO o 0000O O i O N� OZ O�OO Np OLr)M Oi c0 OWN ~ (C) = O v n �^ 03NO) ,Oi (O � N N O� OOP N O NND 0 O m Z� Op M p o0(0 1 C�4 F- O)ON wZ Nw Z OO N3 wZ� 0E-0 0En O Z ONNN-N nCP--Oa n<:2 >>> O ZwZZZ c'n�� + O+� >> Z LLJZ Z OQ—ME0CD Ei0z z= (`. N �u) _ —�� CO o.NN 00 0N�ZZZN �C, < — NIS FIHED GRADE I C Q > > Z 00. OZ EXISTING GRADE 83.26 LF ® 0.567. — 15" RCP 1— WRAP TOP, BOTTOM, AND SIDES — 1 / STONE WITH FILTER FABRIC 4' WASHED �OF STONE BEDDING HIGH WATER ELEVATION _ — 257.45' (100 YR) 63.71 LF ® 1.739, IF —111-4 15,,RCP 26 62 - J c U_�_�_, 1.507. 15" RCP HIGH WATER ELEVATION 255.35' (10 YR) �l J,J 183.24 LF ® 0.00% 24" PERFORATED HDPE 106.43 LF ® 0.00% 24" PERFORATED HDPE 4" WASHED HIGH WATER ELEVATION STONE BEDDING 251.40' (1 YR) 4" WASHED SAND BEDDING N N (n F, m N OO m rn O O 00 O N 0 N O Nj O N O (� co _ O O N _ Oi (O N 0 O (0 0 O O _ OIC!i O N _ ai O N 0 (0 N N N N N N N N N N 275 270 265 260 255 250 245 0+00 1 +00 0+00 1 +00 2+00 3+00 4+00 5+00 GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. 120 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite 112, Fayetteville, NC 28306 office 910-426-6777 fax 1910-426-5777 license number I C-2354 www.4Dsitesotutions.com CAR9 0 JS O ••�j SEA 02 G I NE .•: ja��� �O TT I I111'6 REVISIONS ISSUED FOR CONSTRUCTION PROJECT NAME FAYETTEVILLE HONEYCUTT ROAD DOLLAR GENERAL STORM PROFILES CLIENT PAR 5 DEVELOPMENT GROUP, LLC 2075 Juniper Lake Road West End, North Carolina 27376 Phone: (910) 944-0881 PROJECT INFORMATION DESIGNED BY: SCOTT DRAWN BY: SCOTT CHECKED BY: CHRIS PROJECT NUMBER: 1485 DRAWING SCALE HORIZONTAL: 1 "=30' VERTICAL: 1 "=3' DATE RELEASED MAY 4, 2020 SHEET NUMBER C-600 it 5 0 X N 24' NOTES: 6" 18" �3 R M LU PITCH 1 % LU ~ N ~ J J 3000 PSI CONCRETE PITCH 5% 3"R I F-- N Of U � (0 - U 3000 PSI CONCRETE fE 24" DUMMY GROOVE JOINTS EVERY 10' EXPANSION JOINTS EVERY 50' (90' IF MACHINE PLACED) 24" CURB & GUTTER ROAD WIDENING NOTES: 1. ALL PAVEMENT MARKINGS SHALL BE IN ACCORDANCE WITH POLICY ON STREET AND DRIVEWAY ACCESS TO NORTH CAROLINA HIGHWAY MANUAL AND NCDOT STANDARD DRAWING 1205.04 AND 1205.05. 2. CONTRACTOR SHALL COORDINATE ALL ROAD WIDENING AND PAVEMENT MARKINGS WITH THE NCDOT DISTRICT OFFICE PRIOR TO CONSTRUCTION. CONTACT INFORMATION: TROY BAKER (910) 364-0601 3. CONTRACTOR IS RESPONSIBLE FOR ALL TRAFFIC CONTROL DURING THE ROAD WIDENING OPERATIONS. 4. CONTRACTOR SHALL NOTIFIY ALL PROPERTY OWNERS THAT ARE AFFECTED BY THE ROAD WIDENING INCLUDING BUT NOT LIMITED TO DRIVEWAY REPAIR. 5. CONTRACTOR IS RESPONSIBLE FOR RELOCATING ALL UTILITIES AND INFRASTRUCTURE AFFECTED BY THE WIDENING TO INCLUDE BUT NOT LIMITED TO SIGNS, MAILBOXES, POWER POLES, ETC. CONTRACTOR SHALL REPAIR ANY DAMAGE TO EXISTING PROPERTY RESULTING FROM CONSTRUCTION OF THE IMPROVEMENTS. PAVEMENT WIDENING SECTION 18' 6" �6" BOLLARD 3' 44' 4' CONCRETE PAVEMENT DUMPSTER PAD 1. REMOVE ALL TREATED OR PLASTIC I BURLAP FROM PLANT BALL. 2. INSTALL TOP OF PLANT BALL UP T( 3"-4" ABOVE EXISTING GRADE. 3. SOAK PLANT BALL AND PIT IMMEDIA AFTER INSTALLATION. 4. REMOVE ALL STRING OR WIRE FROM BASE OF TREE 5. KEEP MULCH 2" AWAY FROM TREE TRUNK BASE. FINISHED G =R E IMUM LIMIT OF MULCH fill RFAAn\/Pl FR(1AA WnI F NTS \ EXISTING ASPHALT NTS NTS LAYER OF MULCH SAUCER BERM TO TAIN WATER. V10VE TOP 1 /3 OF RLAP FROM BALL 'SOIL REMOVED FROM HOLE DISTURBED GROUND UNDER BALL TO MINIMIZE SETTLEMENT 10 6" 24" 3"R cV 3000 PSI CONCRETE E 30 _ DUMMY GROOVE JOINTS EVERY 10' EXPANSION JOINTS EVERY 50' (90' IF MACHINE PLACED) 30" STANDARD CURB & GUTTER 6'-0" 6"x6" CONCRETE WHEEL STOP LAG BOLTS & ANCHORS _ SUPPLIED W/ WHEEL STOP. CONCRETE WHEEL STOP ACCESSIBLE PARKING REQUIREMENTS TOTAL PARKING SPACES MINIMUM NUMBER MINIMUM NUMBER OF PROVIDED OF ACCESSIBLE SPACES SPACES REQUIRED ACCESSIBLE SPACES REQUIRED TO BE VAN ACCESSIBLE 1 TO 25 1 1 26 TO 50 2 1 51 TO 75 3 1 76 TO 100 4 1 101 TO 150 5 1 151 TO 200 6 1 201 TO 300 7 1 301 TO 400 8 1 401 TO 500 9 2 501 TO 1000 2% OF TOTAL 1 IN EVERY 8 ACCESSIBLE SPACES 1001 AND OVER 20 PLUS 1 FOR 1 IN EVERY 8 EACH 100 OVER 1000 ACCESSIBLE SPACES SECTION 4.1.2 (5) OF THE AMERICANS WITH DISABILITIES ACT (ADA). SEE 4.1,2,(5) (d) FOR MEDICAL CARE FACILITIES NOTES, 1. ALL 12"08" ACCESSIBLE SIGNS (R7-8 & R7-1) SHALL BE MOUNTED AT 7 FEET FROM GRADE TO BOTTOM EDGE OF SIGN FACE (MUTCD). MOUNTING HEIGHT CAN BE REDUCED TO 5 FEET IF PLACED IN AN AREA BETWEEN SIDEWALK AND BUILDING FACE IN WHICH PEDESTRIANS ARE NOT EXPECTED TO USE. 2. REFER TO MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, (MUTCD) U.S. DEPARTMENT OF TRANSPORTATION AND NORTH CAROLINA DEPARTMENT OF TRANSPORTATION SUPPLEMENT. 3. IF ACCESSIBLE ROUTE IS A RAISED SIDEWALK AREA, THEN RAMPS ARE REQUIRED AT LOADING ZONE AREA. 4. ALL DIMENSIONS, PAVEMENT MARKINGS AND SIGNAGE SHALL COMPLY WITH CURRENT ADA REQUIREMENTS. 4" MULCH TOP OF RC 1 " ABOVE I CLEAN BAC AND FINISH 2" MOUND UNDISTURBI NTS F PAVEMENT NTS 3 7 FINISH GRADE IIIE�IIIII�IIIII� 119.013 CARRY BASE COURSE 6" BEYOND SURFACE COURSE AT LOCATIONS WITHOUT CURB AND GUTTER S9.5B COMPACTED ABCCOMPACTED SUBGRADE HEAVY DUTY PAVEMENT 1 /8" RADIUS -----� i \� JOINT SEALER 4" d• eP d 4" .. .. e .4. 1/2„ �{ JOINT FILLER GROOVE JOINT IN SIDEWALK TRANSVERSE EXPANSION JOINT IN SIDEWALK 7' 5" THICK CONC. SPHALT SIDEWALK 0 6„ I I. IiII Ii1 I6„ NOTE: 8 1. PROVIDE CONTROL JOINTS AT DISTANCE EQUAL TO WIDTH OF SIDEWALK, PROVIDE 1/2" EXP. JOINTS WITH PRE -MOLDED E.J. FILLER AT MAX. 30' O.C. 2. CONCRETE COMPRESSIVE STRENGTH SHALL BE 3000 PSI. IN 28 DAYS. 0 RESERVED RESERVED 0 PARKING �PARKING MUTCD PARKING MUTCD R7-1 R7-8 12"08" 12"X18" DISABLED MUTCD R7-8 PASSENGER 12"08" LOADING ONLY R7-8a R7-8D ACCESSIBLE 12"x6" REQUIRED ACCESSIBLE MAXIMIUM 12•x9" RESERVED PARKING SIGN PENALTY $ 250 MAXIMIUM PENALTY R7-8D $ 250 12"x9" TURN DOWN SIDEWALK NTS NTS ACCESSIBLE ROUTE AD © © © © (SEE NOTE 3) 8" 8" 8" 8" 5" 8" VAN ACCESSIBLE (MINIMUM DIMENSIONS) SPACE ONE OUT OF EVERY EIGHT (8) ACCESSIBLE SPACES, BUT NOT LESS THAN ONE, IS REQUIRED TO BE VAN ACCESSIBLE. PARKING SPACE PAVEMENT MARKINGS HANDICAP SIGNAGE AND PAVEMENT MARKINGS NTS E 0 SUBGRADE CARRY BASE COURSE 6" BEYOND SURFACE COURSE AT LOCATIONS WITHOUT CURB AND GUTTER (D COMPACTED C NTS LIGHT DUTY PAVEMENT CONCRETE COLLAR o I N CONSTRUCTIO JOINT 11 FILL POST WITH CONCRETE. 6" DIA. STEEL PIPE PAINTED YELLOW. FINISHED GRADE OR ASPHALT AS REQUIRED. 3,000 PSI. CONCRETE BASE 6" 6" 6" DUMPSTER BOLLARD 1 /8" RADIUS -----� \ JOINT SEALER 1/8" TO 1/4" .a 5" 1/2„ JOINT FILLER TRANSVERSE EXPANSION JOINT IN SIDEWALK NOTE: \a\a\a\a�a\,i, 1. PROVIDE CONTROL JOINTS AT DISTANCE EQUAL TO WIDTH OF SIDEWALK, PROVIDE 1/2" EXP. JOINTS WITH PRE -MOLDED E.J. FILLER AT MAX. 30' O.C. 2. CONCRETE COMPRESSIVE STRENGTH SHALL BE 3000 PSI. IN 28 DAYS. II 4" GROOVE JOINT IN SIDEWALK CONCRETE WALK NTS NTS 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite.U2, Fayetteville, NC 28306 office 910-426-6777 fax 1910-426-5777 license number I C-2354 www.4Dsitesolutions.com �IICARO,�Z// O .•2 i SEA 02 G I NE .•: ja��� V//;, 00 050- REVISIONS ISSUED FOR CONSTRUCTION PROJECT NAME FAYETTEVILLE HONEYCUTT ROAD DOLLAR GENERAL SITE & STORM DETAILS CLIENT PAR 5 DEVELOPMENT GROUP, LLC 2075 Juniper Lake Road West End, North Carolina 27376 Phone: (910) 944-0881 PROJECT INFORMATION DESIGNED BY: SCOTT DRAWN BY: SCOTT CHECKED BY: CHRIS PROJECT NUMBER: 1485 DRAWING SCALE NOT TO SCALE DATE RELEASED MAY 4, 2020 SHEET NUMBER TREE PLANTING NTS SHRUB PLANTING NTS C-700 0 QD 1 4"x4" TREATED WOOD POSTS ® 6'-0" OC MAX. 1"x6" CEDAR OR TREATED WOOD VERTICAL BOARDS 2"x4" TREATED WOOD HORIZONTAL NAILERS FINISHED GRADE VARIES III W/ CONCRETE FILLED 18'-0" CLEAR Ilk 1-1 1 —11 DUMPSTER ENCLOSURE NTS E HANDICAP RAMP NTS 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite.U2, Fayetteville, NC 28306 office 1 910-426-6777 fax 1910-426-5777 license number I C-2354 www.4Dsitesotutions.com N,CARO �Z// �2:pFSS0% SEA 02 •G I NE .•: ja��� 1/� O 111116��``` 05"- U4/-2U REVISIONS ISSUED FOR CONSTRUCTION PROJECT NAME FAYETTEVILLE HONEYCUTT ROAD DOLLAR GENERAL SITE & STORM DETAILS CLIENT PAR 5 DEVELOPMENT GROUP, LLC 2075 Juniper Lake Road West End, North Carolina 27376 Phone: (910) 944-0881 PROJECT INFORMATION DESIGNED BY: SCOTT DRAWN BY: SCOTT CHECKED BY: CHRIS PROJECT NUMBER: 1485 DRAWING SCALE NOT TO SCALE DATE RELEASED MAY 4, 2020 SHEET NUMBER C-701 FLARED SIDE (BEYOND) Sapp r 20 SLOPE 1:2(,SLOPE 4' CONC. SLAB NEW CURB TYP. ROLL CURB SECTION AT HANDICAP RAMP SECTION B-B 6> 6'-0" 5'-0" 6' 0' SIDEWALK CURB MIN. CURB TOP OF A S ELEVATION TRANSITION DROP TRANSITION CURB pR� + CURB ---�- GUTTER ti / M/N4" VARIABLE SLOPES NOT TO EXCEED 10:1 (10%) SECTION A -A ISOMETRIC VIEW EXPION (SEE STD 846.01 SIDEWALK o�� ---- - _ 2_0 EXPANSION JOINT ci NOTE 11,, SEE S . 848.01) JOINT W A W+A+9" X B 5' 0.0' 5.8' 5.8' 5.0' * 6' 0.0' 6.8' 6.8' 6.0' 7' 0.0' 7.8' 7.3' 6.5' 8' 0.0' 8.8' 7.3' 6.5' 5' 2.0' 7.8' 7.8' 5.0' 5' 2.5' 8.3' 8.1' 4.8' 5' 3.0' 8.8' 8.3' 4.4' 5' 3.5' 9.3, 8.4' 4.1' 5' 4.0' 9.8' 8.6' 3.8' 5' 4.5' 10.3' 8.7' 3.4' 5' 5.0' 10.8' 8.9' 3.1' B=X-(A+9") B = DISTANCE FROM FRONT GE OF SIDEWALK TO BACK POINT OF 12A 8.33%) SLOPE. * BACK OF SIDEWALK DROP REQUIRED FOR ALL SIDEWALK SLOPES. * * BACK OF SIDEWALK DROP REQUIRED FOR SIDEWALK SLOPES 0.04. NOTE: 1. A PORTION OF ONE OR BOTH RAMPS MAY EXTEND OUTSIDE THE RETURN. 2. PLACE EXPANSION JOINT ON ALL SIDES WHERE SIDEWALK ABUTS RAMP. NOTE 1 Ij a�� 1�/�/i 433 HAY ST. 28301 yl SEENOTES K �jL�,(��/u�,�j (910) 433-1656 4' A' CL AR SPACE I��` http://www.fayettevillenc.gov J VIEW IIIUS CROSSWALK uMi"rs (SEE NOTE 10) PLAN VIEW A4 RAMP WHEELCHAIR RAMP W/ 25 RADII DUAL RAMPS [NOT PERMISSIBLE FOR CON�TRUCTIONI (4' MIN ANY FLOORIIWIDTH) SIDEWALK OFF BACK OF CURB Rev. Date: O1MAR18 SEE SHEET SD-2.3 FOR WHEELCHAIR RAMP NOTES. Not to Scale S D - 2. 1 Review Date: O1JAN19 1/2" JOINT SEALER 1/8" RADIUS (TYPICAL) 1)8" JOINT FILLER 1/2" UNLESS NOTED OTHERWISE EXPANSION JOINT 1/2" JOINT SEALER 1/8" RADIUS (TYPICAL) FSEENOTE 2 .) 1/2" UNLESS NOTED OTHERWISE CONTRACTION JOINT NOTES: 1. CONTRACTION JOINTS IN CURB AND GUTTER SHALL BE SPACED AT 10-FOOT INTERVALS. SIDEWALK CONTRACTION JOINTS SHALL BE SPACED AT 5-FOOT INTERVALS. JOINT SPACING MAY BE ALTERED BY THE CITY ENGINEER TO PREVENT UNCONTROLLED CRACKING. 2. CONTRACTION JOINTS SHALL BE MINIMUM 1" DEEP WHEN INSTALLED BY THE USE OF TEMPLATES OR FORMED BY OTHER APPROVED METHODS. WHERE SUCH JOINTS ARE NOT FORMED BY TEMPLATES, A MINIMUM DEPTH OF 1 1/2" SHALL BE OBTAINED. 3. ALL EXPANSION JOINTS SHALL BE SPACED AT 30-FOOT INTERVALS FOR HAND FORMED, AND ADJACENT TO ALL RIGID OBJECTS. JOINTS SHALL MATCH LOCATIONS WITH JOINTS IN ABUTTING SIDEWALK. IF CURB IS MACHINED A 90' SPACING IS ALLOWABLE 4. REFER TO NCDOT DETAILS 846.01 AND 848.01 FOR MORE INFORMATION. 433 HAY ST. 28301 %seffew(910) 433-1656 http://www. fayettevillenc.gov CONTRACTION AND EXPANSION JOINT Rev. Date: 16JAN18 1 DT� - 3 Not to Scale II 1 Review Date: O1JAN19 S TEMPORARY SEEDING/MULCHING SPECIFICATIONS (FOR LATE WINTER AND EARLY SPRING) SEEDING MIXTURE: SPECIES RATE (LB./ACRE) RYE (GRAIN) 120 ANNUAL KOBE LESPEDEZA 50 OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT EXTEND BEYOND JUNE. SEEDING DATES: JANUARY 1 - MAY 1 SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LBJACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB./ACRE 10-10-10 FERTILIZER. MULCH: APPLY 4,000 LB./ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. TEMPORARY SEEDING/MULCHING SPECIFICATIONS (FOR SUMMER) SEEDING MIXTURE: SPECIES RATE (LB./ACRE) GERMAN MILLET 40 A SMALL -STEMMED SUDANGRASS MAY BE SUBSTITUTED AT A RATE OF 50 LB./ACRE. SEEDING DATES: MAY 1- AUGUST 15 SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB./ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB./ACRE 10-10-10 FERTILIZER. MULCH: APPLY 4,000 LB./ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. TEMPORARY SEEDING/MULCHING SPECIFICATIONS (FOR FALL) SEEDING MIXTURE: SPECIES RATE (LB./ACRE) RYE (GRAIN) 120 SEEDING DATES: AUGUST 15 - DECEMBER 30 SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB./ACRE GROUND AGRICULTURAL LIMESTONE AND 1,000 LB./ACRE 10-10-10 FERTILIZER. MULCH: APPLY 4,000 LBJACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOP DRESS WITH 50 LBJACRE OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB./ACRE KOBE LESPEDEZA IN LATE OR EARLY MARCH. 2 TEMPORARY SEEDING SPECIFICATIONS 1. CONSTRUCT THE WALKING SURFACE WITH SLIP RESISTANCE AND A 70% CONTRASTING COLOR TO THE SIDEWALK. WHEELCHAIR RAMP SHALL ALSO INCLUDE A BLACK, TRUNCATED DOME STRIP. 2. CROSSWALK WIDTHS AND CONFIGURATION VARY BUT MUST CONFORM TO TRAFFIC DESIGN STANDARDS. 3. NORTH CAROLINA GENERAL STATUTE 136-44.14 REQUIRES THAT ALL STREET CURBS BEING CONSTRUCTED OR RECONSTRUCTED FOR MAINTENANCE PROCEDURES, TRAFFIC OPERATIONS, REPAIRS, CORRECTION OF UTILITIES OR ALTERED FOR ANY REASON AFTER SEPTEMBER 1, 1973 SHALL PROVIDE WHEELCHAIR RAMPS FOR THE PHYSICALLY DISABLED AT ALL INTERSECTIONS WHERE BOTH CURB AND GUTTER AND SIDEWALKS ARE PROVIDED AND AT OTHER POINTS OF PEDESTRIAN FLOW. IN ADDITION, SECTION 228 OF THE 1973 FEDERAL AID HIGHWAY SAFETY ACT REQUIRES PROVISION OF CURB RAMPS ON ANY CURB CONSTRUCTION AFTER JULY 1, 1976 WHETHER A SIDEWALK IS PROPOSED INITIALLY OR IS PLANNED FOR A FUTURE DATE. THE AMERICANS WITH DISABILITIES ACT (ADA) OF 1990 EXTENDS TO INDIVIDUALS WITH DISABILITIES. COMPREHENSIVE CIVIL RIGHTS PROTECTIONS SIMILAR TO THOSE PROVIDED TO PERSONS ON THE BASIS OF RACE, SEX, NATIONAL ORIGIN AND RELIGION UNDER THE CIVIL RIGHTS ACT OF 1964. THESE CURB RAMPS HAVE BEEN DESIGNED TO COMPLY WITH THE CURRENT ADA STANDARDS. 4. PROVIDE WHEELCHAIR RAMPS AT LOCATIONS AS SHOWN ON THE PLANS OR AS DIRECTED BY THE ENGINEER. LOCATE WHEELCHAIR RAMPS AS DIRECTED BY THE ENGINEER WHERE EXISTING LIGHT POLES, FIRE HYDRANTS, DROP INLETS, ETC. AFFECT PLACEMENT. WHERE TWO RAMPS ARE INSTALLED NOT LESS THAN 2 FEET OF FULL HEIGHT CURB SHALL BE PLACED BETWEEN THE RAMPS. PLACE DUAL RAMPS AS NEAR PERPENDICULAR TO THE TRAVEL LANE BEING CROSSED AS POSSIBLE. 5. PAY FOR ALL VARIABLE DEPTH CONCRETE USED FOR CONSTRUCTION OF WHEELCHAIR RAMPS AS CONCRETE WHEELCHAIR RAMPS AS DESCRIBED ON PROJECT SPECIFICATIONS. 6. PAY FOR ALL DEPRESSED CURBS AT WHEELCHAIR RAMPS AS THE TYPE CURB AND GUTTER USED ADJACENT TO DEPRESSED CURB. (LN. FT.) 7. SUCH PRICES AND PAYMENTS WILL BE CONSIDERED FULL COMPENSATION FOR ALL MATERIALS, LABOR, EQUIPMENT, TOOLS AND INCIDENTALS NECESSARY TO SATISFACTORILY COMPLETE THE WORK. B. DO NOT EXCEED 0.08 (1:12) SLOPE ON THE WHEELCHAIR RAMP IN RELATIONSHIP TO THE GRADE OF THE STREET. 9. CONSTRUCT WHEELCHAIR RAMPS 48" (ADA STANDARD) OR GREATER FOR DUAL RAMPS. 10. USE CLASS "B" CONCRETE WITH A SIDEWALK FINISH IN ORDER TO OBTAIN A ROUGH NON-SKID TYPE SURFACE. 11. PLACE A 1/2" EXPANSION JOINT WHERE THE CONCRETE WHEELCHAIR RAMP JOINS THE CURB AND AS SHOWN ON SD-2. 12. PLACE THE INSIDE PEDESTRIAN CROSSWALK LINES NO CLOSER IN THE INTERSECTION BY BISECTING THE INTERSECTION RADII, WITH ALLOWANCE OF A 4' CLEAR ZONE IN THE VEHICULAR TRAVELWAY WHEN ONE RAMP IS INSTALLED. (SEE NOTE 17) 13. COORDINATE THE CURB CUT AND THE PEDESTRIAN CROSSWALK LINES SO THE FLOOR OF THE WHEELCHAIR RAMP WILL FALL WITHIN THE PEDESTRIAN CROSSWALK LINES. PLACE DIAGONAL RAMPS WITH FLARED SIDES SO 24" OF FULL HEIGHT CURB FALLS WITHIN THE CROSSWALK MARKINGS ON EACH SIDE OF THE FLARES. 14. CONSTRUCT THE PEDESTRIAN CROSSWALK A MINIMUM OF 6 FEET. A CROSSWALK WIDTH OF 10 FEET OR GREATER IS DESIRABLE. 15. USE STOP LINES, NORMALLY PERPENDICULAR TO THE LANE LINES, WHERE IT IS IMPORTANT TO INDICATE THE µ_. y ENGINEERING DIVISION POINT BEHIND WHICH VEHICLES ARE REQUIRED TO STOP IN COMPLIANCE WITH A TRAFFIC SIGNAL, STOP SIGN Q�1//1 NII// 433 HAY ST. 28301 OR OTHER LEGAL REQUIREMENT. AN UNUSUAL APPROACH SKEW MAY REQUIRE THE PLACEMENT OF THE v LLLLLL�i YYYlll111LL11W/� (910) 433-1656 STOP LINE TO BE PARALLEL TO THE INTERSECTING ROADWAY. http://www.fayettevillenc.gov 16. TERMINATE PARKING A MINIMUM OF 20 FEET BACK OF PEDESTRIAN CROSSWALK. 17. PLACE ALL PAVEMENT MARKINGS IN ACCORDANCE WITH THE LATEST EDITION OF THE MANUAL OF UNIFORM WHEELCHAIR RAMP NOTES TRAFFIC CONTROL DEVICES (MUTCD) PUBLISHED BY THE FEDERAL HIGHWAY ADMINISTRATION AND THE NORTH CAROUNA SUPPLEMENT TO THE MUTCD. Rev. Date: O1MAR18 Not to Scale S D - 2.3 Review Date: OLJAN19 B/C R/W 2'-6" 7'-6" f2% CROSS SLOPE pQEM WITHIN R/WGRASS NOTE 1 UTILITY 5'-0' I I_A1 I-1 I STRIP �I 1IIIIIIIII I= IMI1=1IMI1- -1 I �I I-1 I I- ' ROLL BACK CURB B/C R/W 2'-6" 7'-6" ---*--2% CROSS SLOPE WITHIN 7'- h NOTE 1 GRASS 5'-0' lr UTILITYSTRIP J 11-1 I I- 11-111-I i 111, ; l-1 _I _ VERTICAL CURB NOTES: 1. VERTICAL CURB - GRASS UTILITY STRIP MAY BE REMOVED UPON APPROVAL OF THE CITY ENGINEER. • 433 RAY ST. 28301 IF NO GRASS UTILITY STRIP, INSTALL 1/2" EXPANSION JOINT MATERIAL BETWEEN BACK OF (910) 433-1656 CURB AND SIDEWALK. http://www.fayettevillene.gov 2. SEE DETAIL SD-3 CONTRACTION AND EXPANSION JOINT. 3. SEE DETAIL SD-9 TYPICAL RESIDENTIAL DRIVEWAY APRON AND DETAIL SD-9.1 TYPICAL COMMERCIAL DRIVEWAY APRON. TYPICAL SIDEWALK SECTION 4. SODDING LIMITS INCLUDE THE GRASS UTILITY STRIP BETWEEN THE BACK OF CURB AND THE SIDEWALK AS WELL AS 2'6" BEYOND THE SIDEWALK. 5. SEE TECHNICAL SPECIFICATION SECTION 00455, PART 3, SUB -SECTION 3.02, SUB -PART F. Rev. Date: 310CT18 Not to Scale SD-12 Review Date: OIJAN19 SEEDING SPECIFICATIONS SEEDING MIXTURES: SPECIES RATE (LBS./ACRE TALL FESCUE 80 PENSACOLA BAHIAGRASS 50 SERICEA LESPEDEZA 30 KOBE LESPEDEZA 10 SEEDING NOTES: 1. FROM SEPT. 1 TO MAR. 1 USE UNSCARIFIED SERICEA SEED. 2. ON POORLY DRAINED SITES OMIT SERICEA AND INCREASE KOBE TO 30 LB./ACRE. 3. WHERE A NEAT APPEARANCE IS DESIRED, OMIT SERICEA AND INCREASE KOBE TO 40 LB./ACRE. NURSE PLANTS: BETWEEN APRIL 15 AND AUG. 15, ADD 10 LB./ACRE OF GERMAN MILLET OR 15 LB./ACRE SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUG. 15, ADD 25 LB./ACRE RYE (GRAIN). SEEDING DATES: BEST POSSIBLE EARLY SPRING: FEB. 15 - MAR. 20 FEB. 15 - APR. 30 FALL: SEPT. 1 - SEPT. 30 SEPT. 1 - OCT. 31 SOIL AMENDMENTS: APPLY LIME AND FERTILIZER ACCORDING TO SOIL TEST, OR APPLY 3,000 - 5,000 LB./ACRE GROUND AGRICULTURAL LIMESTONE (USE THE LOWER RATE ON SANDY SOILS) AND 1,000 LB./ACRE 10-10-10 FERTILIZER. MULCH: APPLY 4,000 LB./ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCH. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR ROVING OR BY CRIMPING WITH A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: IF GROWTH IS LESS THAN FULLY ADEQUATE, REFERTILIZE IN THE SECOND YEAR, ACCORDING TO THE SOIL TESTS OR TOP DRESS WITH 500 LB./ACRE 10-10-10 FERTILIZER. MOW AS NEEDED WHEN SERICEA IS OMITTED FROM THE MIXTURE. RESEED, FERTILIZE, AND MULCH DAMAGED AREAS IMMEDIATELY. SEEDING SPECIFICATIONS SEEDING MIXTURE SPECIES RATE (LB./ACRE) COMMON BERMUDAGRASS 40-80(1-2 LB./1,000 FTC) SEEDING DATES: COASTAL PLAIN: APR. - JULY SOIL AMENDMENTS: APPLY LIME AND FERTILIZER ACCORDING TO SOIL TEST, OR APPLY 3,000 LBJACRE GROUND AGRICULTURAL LIMESTONE AND 500 LB./ACRE 10-10-10 FERTILIZER. MULCH: USE JUTE, EXCELSIOR MATTING, OR OTHER EFFECTIVE CHANNEL LINING MATERIAL TO COVER THE BOTTOM OF CHANNELS AND DITCHES. THE LINING SHOULD EXTEND ABOVE THE HIGHEST CALCULATED DEPTH OF FLOW. ON CHANNEL SIDE SLOPES ABOVE THIS HEIGHT, AND IN DRAINAGES NOT REQUIRING TEMPORARY LININGS, APPLY 4,000 LBJACRE GRAIN STRAW AND ANCHOR STRAW BY STAPLING NETTING OVER THE TOP. MULCH AND ANCHORING MATERIALS MUST NOT BE ALLOWED TO WASH DOWN SLOPES WHERE THEY CAN CLOG DRAINAGE DEVICES. MAINTENANCE: A MINIMUM OF 3 WEEKS IS REQUIRED FOR ESTABLISHMENT. INSPECTION AND REPAIR MULCH FREQUENTLY. REFERTILIZE THE FOLLOWING APR. WITH 50 LBJACRE NITROGEN. 3 PERMANENT SEEDING SPECIFICATIONS O O O O O O O O O O O O O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O O O O O O O O O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O O O O O O O O O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4'-0" MIN. VARIES WITH WIDTH OF RAMP TRUNCATED DOME PLAN VIEW TO O O O O L O O O O O O O 3 TRUNCATED DOME SPACING � -0.2' TRUNCATED DOME SECTION NOTES: 1. ALL DETECTABLE WARNING DEVICES USED IN NEW CONSTRUCTION SHALL BE OF A RIGID PRECAST OR EMBEDDED PRODUCT APPROVED BY THE CITY ENGINEER. RETRO FIT MATS WILL ONLY BE ALLOWED ON EXISTING RAMPS WITH PRIOR APPROVAL OF THE CITY ENGINEER FOR MATERIAL TYPE AND INSTALLATION (IE. RESURFACING). 2. WIDTH OF DETECTABLE WARNING AREA SHALL BE A MINIMUM OF 4 FEET AND VARY WITH WIDTH OF RAMP. 3. LENGTH OF DETECTABLE WARNING AREA SHALL BE 2 FEET REGARDLESS OF SECTION WIDTH. 4. DETECTABLE WARNING AREA CAN BE SQUARE WHERE USED IN A CURB RADIUS. 5. DETECTABLE WARNING DOMES SHALL BE ALIGNED ON A SQUARE GRID IN THE PREDOMINANT DIRECTION OF OF TRAVEL TO PERMIT WHEELS TO ROLL BETWEEN DOMES. 6. IF PAVERS ARE TO BE USED PAVERS SHALL BE 6" THICK AND CAST FROM 5000 psi CONCRETE. 7. MATS ARE TO BE RIGID WITH TURN DOWN EDGES EMBEDDED IN CONCRETE TO ELIMINATE TRIP HAZARD. 8. TRUNCATED DOMES ARE TO BE BLACK IN COLOR. ryb BPS OQF. G�Oc�S 0 I 1n 8'-0' BUS STOP PAD PLAN VIEW SURFACE TEXTURE TO BE OBTAINED BY A COARSE BROOMING ISOMETRIC VIEW 5 (1.6" TO 2.4") 433 RAY 28301 910 43333-1656 http: www. f aye ttevillenc.gov TRUNCATED DOME DETAILS Rev. Date: O1MAY18 Not to Scale S D - 2 . 5 Review Date: O1JAN19 PROVIDE MIN. 5'-0" WI `N ACCESS PAD BETWE SIDEWALK AND CU z N BUS STOP PAD 20'-0" OFF BACK OF CURB Fie* ENGINEERING DIVISION BUS STOP SHELTER PAD - PLAN VIEW 433 HAY 28301 (910) 43328301 http: //www. fayettevillene.gov NOTES: 1. BUS STOP PAD SHALL BE PLACED BEHIND THE SIDEWALK. 2. IF SIDEWALK IS OFF THE BACK OF CURB, THE BUS STOP SHELTER PAD WIDTH SHALL BE 5'-0" DETAIL OF BUS STOP PAD 3. IF SIDEWALK IS ON THE BACK OF CURB, THE BUS STOP SHELTER PAD WIDTH SHALL BE 5'-0" FOR SPEED LIMITS UP TO 35 MPH; FOR SPEED LIMITS ABOVE 35 MPH, WIDTH SHALL BE 8'-0". 4. CONCRETE SHALL DEVELOP AT 28 DAYS A MIN COMPRESSIVE STRENGTH OF 3000 PSI. Rev. Date: 30MAY18 �J Not to Scale Review Date: OLJAN19 S D 1L/ BUS STOP PAD ON BACK OF CURB 1. UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONSTRUCTED AND MAINTAINED IN ACCORDANCE WITH THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL HANDBOOK. 2. THE CONTRACTOR SHALL NOTIFY PLAN APPROVING AUTHORITY ONE WEEK PRIOR TO THE PRECONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO FINAL INSPECTION. 3. IF POSSIBLE ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO CLEARING AND/OR LAND DISTURBANCE 4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN AND PERMIT SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. 5. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO OFF -SITE BORROW OR WASTE AREAS, STAGING OR STORAGE AREAS), THE CONTRACTOR SHALL PREPARE AND SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND TO NCDENR REGIONAL OFFICE FOR APPROVAL. CONTRACTOR SHALL PAY ALL FEES REQUIRED AND SHALL INSTALL NECESSARY MEASURES AT NO SEPARATE PAYMENT. THE CONTRACTOR SHALL PROVIDE THE OWNER AND THE ENGINEER A COPY OF THE AMENDED PERMIT. 6. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY EITHER NCDENR OR THE ENGINEER. 7. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED. 8. ALL AREAS DISTURBED BY CONSTRUCTION UNLESS OTHERWISE IMPROVED SHALL BE SODDED OR SEEDED AS INDICATED AND STABILIZED. 9. DURING DEWATERING OPERATIONS, WATER SHALL BE PUMPED INTO AN APPROVED FILTERING DEVICE PRIOR TO DISCHARGE TO RECEIVING OUTLET. 10. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES WEEKLY AND AFTER EACH RUNOFF -PRODUCING EVENT ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. 11. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED BY CONTRACTOR ONCE STABILIZATION OR A SUFFICIENT GROUND COVER HAS BEEN ESTABLISHED OR AS DIRECTED BY THE ENGINEER. NCDENR'S FINAL APPROVAL IS REQUIRED. 12. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE SHALL BE REQUIRED AT ALL CONSTRUCTION STAGING AREA ENTRANCES AND ALL CONSTRUCTION ACCESS LOCATIONS INTO NON -PAVED AREA. 13. WHEN CROSSING CREEK OR DRAINAGE -WAY, THE CONTRACTOR SHALL RIP -RAP WITH FABRIC DISTURBED BANKS AND CHANNEL AND RESTORE SLOPES TO ORIGINAL CONTOURS, BUT NOT STEEPER THAN 2:1 MAXIMUM. DISTURBED CREEK AREA SHALL BE STABILIZED IMMEDIATELY. 4 GENERAL EROSION AND SEDIMENT CONTROL NOTES DRIVE STEEL POSTS 18" INTO THE GROUND ATTACH WIRE FENCE TO POSTS AND EXTEND NOTES: MAXIMUM 8' O.C. AND EXCAVATE A 4" X 8" THE BOTTOM OF THE FENCE 8" INTO THE TRENCH UPHILL ALONG THE LINE OF EXCAVATED TRENCH AND TURNED OUT POSTS. 4" IN THE TRENCH. 1. WIRE SHALL BE A MINIMUM OF 32 INCHES IN WIDTH AND TOP & BOTTOM STRAND SHALL HAVE A MINIMUM OF 6 WIRES WITH 12" STAY SPACING. MIN. 10 GA. WIRE 2. FILTER FABRIC SHALL BE A MINIMUM OF 36" IN WIDTH AND STEEL POSTS STAY WIRES SHALL BE FASTENED ADEQUATELY TO THE WIRE WITH #9 WIRE MIN. 12-1/2 GA STAPLES 1-1/2" LONG. FABRIC THAT DETERIORATES TO SUCH LINE WIRES EXTENT THAT IT'S EFFECTIVENESS IS REDUCED SHALL BE MIN. 12-1/2 GA. REPLACED BY CONTRACTOR AT CONTRACTOR'S EXPENSE. 3. STEEL POSTS SHALL BE A MIN. OF 5' HEIGHT AND SHALL BE THE SELF FASTENER ANGLE STEEL TYPE. 4. CONTRACTOR SHALL REVIEW SILT FENCE ONCE PER WEEK - AND AFTER EACH RAINFALL OCCURRENCE. ANY NECESSARY -- REPAIRS OR CLEAN-UP TO MAINTAIN THE EFFECTIVENESS OF ' THE DEVICE SHALL BE MADE IMMEDIATELY. 70� 5. REMOVE DEPOSITED SEDIMENT ALONG THE FENCE TO PROVIDE ADEQUATE STORAGE VOLUME AND TO REDUCE . 7l' PRESSURE ON THE FENCE AS NEEDED. STEP 1 STEP 2 U 5. TEMPORARY MEASURE SHALL NOT BE REMOVED BY THE CONTRACTOR UNTIL THIS ACTION IS APPROVED BY AN NCDENR ATTACH THE FILTER FABRIC TO THE WIRE FENCE, BACKFILL THE TRENCH AND COMPACT THE SOIL REPRESENTATIVE. THE ACTION WILL BE APPROVED WHEN THE EXTEND THE BOTTOM OF THE FABRIC 8" INTO THE FIRMLY TO ANCHOR THE BOTTOM OF THE SILT CONTRIBUTING DRAINAGE AREA IS STABLE. TRENCH AND TURNED OUT 4" IN THE TRENCH. FENCE. BURIED FABRIC SHALL NOT BE VISIBLE. POSTS MAX 8' O.C. WIRE FENCE "HOG WIRE" A FILTER FABRIC I' x #9 WIRE STAPLES 1-112" LONG �I BOTTOM OF WIRE FENCE AND \ �- O FILTER FABRIC BURIED 8" IN EXCAVATED TRENCH & TURNED x OUT 4" IN THE TRENCH _LOW STEEL POST DRIVEN 24" INTO GROUND A _Ifs STEP 3 STEP 4 SECTION A -A MAINTENANCE 1. INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. 2. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. 3. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. ■ /� 4. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO T GRADE AND STABILIZE AFTER NTS THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED AND NCDENR APPROVES REMOVAL. 6 SILT FENCE 1 RETAINING CURB / MAINTAIN GRADE OF SIDEWALK ADJACENT TO RAMP SURFACE TEXTURE TO BE OBTAINED BY A COARSE BROOMING 2'0' TRAVERSE TO THE SLOPES OF C\ RAMP. 833 A,r LESS THAN 5' RETAINING CURB 2% MAX la 8.33% MAX SIDEWALK N CURB & GUTTER TRUNCATED DOMES PLAN VIEW 'A' MORE THAN 5' RETAINING CURB 2% MAX a < _ N 8.33% MAX SIDEWALK TRUNCATED DOMES SHALL EXTEND FROM RETAINING CURB TO ISOMETRIC VIEW RAMP PLAN VIEW W NOTE: IF THE DISTANCE BETWEEN THE ROADWAY AND THE RAMP IS LESS THAN 5,' THEN TRUNCATED DOMES SHALL VARIES 2'-0" VARIES BE INSTALLED AS SHOWN IN PLAN VIEW W. WHEN THE DISTANCE IS GREATER THAN 5% TRUNCATED DOMES SHALL BE INSTALLED AS SHOWN IN PLAN VIEW V. TRUNCATED DOMES 6• RETAINING CURB ENGINEERING DIVISION M* (910) 433 BAY 28301 43333-1656 http://www.fayettevillenc.gov (STD 2'-6" CURB 4^ & GUTTER SHOWN) DIRECTIONAL CURB RAMP SECTION A -A Rev. Date: O1MAY18 SEE SHEET SD-2.3 FOR WHEELCHAIR RAMP NOTES. Not to Scale S D - 2.7 Review Date: O1JAN19 6" STABILIZED AGGREGATE SAWCUT ASPHALT EDGES EXISTING ASPHALT BASE COURSE COMPACTED STRAIGHT AND TRUE TO 100% MAX. DENSITY 1 1 /2" SF 9.5 A EX. BASE l OAT REPLACE�j (0.25C 6AL/SY.) AS REQUIRED / 2° 'No NOTE: L/ SEE PIPE BEDDING DETAIL :��, UNDISTURBED SOIL IF PAVEMENT SETTLEMENT OCCURS. THE CONTRACTOR SHALL REPATCH AT NO ADDITIONAL EXPENSE TO THE OWNER. REPLACE TO EXISTING OR BETTER THAN DETAIL TO BE DETERMINED BY THE ENGINEER. PAVEMENT PATCH NTS STANDARD METAL POSTS 2'-0" IN GROUND 19 GAUGE HARDWARE CLOTH (1/4 MESH OPENINGS) 0 1 4 1 O Ora 0 -� 0 �, % - - �W60�WO'aOOCb o - -� -------- 2:1 SLOPE GRAVEL FILTER / 57 WASHED STONE PLACED TO A HEIGHT OF 16' MINIMUM ABOVE TOP OF BOX 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. 2. DRIVE 5-FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE INLET. SPACES POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART. 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE AND BOTTOM. PLACING A 2 FOOT FLAP OF THE WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS RECOMMENDED. 4. PLACE CLEAN GRAVEL (NCDOT /5 OR #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE WIRE AND SMOTH TO AN EVEN GRADE. 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ACCUMULATED SEDIMENT AND ESTABUSH FINAL GRADING ELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZE IT WITH GROUNDCOVER. MAINTENANCE INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER OBJECTS TO PROVIDE ADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING THE SEDIMENT REMOVAL. REPLACE STONE AS NEEDED, NTS 5 HARDWARE CLOTH & GRAVEL INLET PROTECTION DESIGN CRITERIA AGGREGATE SIZE - USE 2-3 INCH WASHED STONE DIMENSION OF GRAVEL PAD GRAVEL ENTRANCE SHALL BE 50 FEET IN LENGTH AND 12 FEET IN WIDTH THICKNESS - 6 INCHES MINIMUM WITH 20 FOOT RADIUS AT EXISTING WIDTH - 12 FT. MINIMUM OR FULL WIDTH AT ACCESS ROADWAY POINTS OF THE VEHICULAR ENTRANCE AND EXIT 36-0" MIN 4'-0" 10'-0" AREA, WHICHEVER IS GREATER 6"� LENGTH- 50 FT. MINIMUM. LOCATION - LOCATE CONSTRUCTION ENTRANCES AND p EXITS TO LIMIT SEDIMENT FROM LEAVING THE SITE AND TO PROVIDE FOR MAXIMUM UTILITY BY ALL FILTER FABRIC CONSTRUCTION VEHICLES. AVOID STEEP GRADES 2-3" WASHED STONE AND ENTRANCES AT CURVES IN PUBLIC ROADS. CONTRACTOR SHALL INSTALL ADDITIONAL GRAVEL GRAVEL CONSTRUCTION ENTRANCE CONSTRUCTION ENTRANCES NOT INDICATED ON THE PLANS REQUIRED FOR STAGING AND/OR BORROW AREAS AND MAINTAIN AT NO ADDITIONAL EXPENSE TO THE OWNER. CONTRACTOR SHALL SUPPLEMENT AND MAINTAIN GRAVEL CONSTRUCTION ENTRANCES AT HIS EXPENSE UNTIL FINAL ACCEPTANCE. OV9 / NG MAINTENANCE QJ MAINTAIN THE GRAVEL PAD INBA CONDITION TO PREVENT MUD OR Z SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY 50' REQUIRE REQUIRE PERIODIC TOPDRESSING WITH 2-INCH STONE. AFTER EACH Min. INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL / OBJECTIONABLE MATERIALS SPILLED, WASHED OR TRACKED ONTO PUBLIC ROADWAYS. O AGGREGATE �rL 6" MIN. THICKNESS 2-3" COURSE NTS 7 TEMPORARY GRAVEL CONSTRUCTION ENTRANCE 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite 112, Fayetteville, NC 28306 office 910-426-6777 fax 1910-426-5777 license number I C-2354 www.4Dsitesotutions.com ``01CARO ,��'' `� e` •••••.•.•••• ' • Q SEA ��•' 02 G IN ••: ja�`� COTT '6 05"- REVISIONS ISSUED FOR CONSTRUCTION PROJECT NAME FAYETTEVILLE HONEYCUTT ROAD DOLLAR GENERAL SITE & EROSION CONTROL DETAILS CLIENT PAR 5 DEVELOPMENT GROUP, LLC 2075 Juniper Lake Road West End, North Carolina 27376 Phone: (910) 944-0881 PROJECT INFORMATION DESIGNED BY: SCOTT DRAWN BY: SCOTT CHECKED BY: CHRIS PROJECT NUMBER: 1485 DRAWING SCALE NOT TO SCALE DATE RELEASED MAY 4, 2020 SHEET NUMBER C-702 1. CONTRACTOR SHALL REPAIR ALL WATER LATERALS AND MAINS DAMAGED DURING 9. SEPARATION REQUIREMENTS: CONSTRUCTION. THE CONTRACTOR SHALL REPORT IMMEDIATELY ALL WATER MAIN A. LATERAL SEPARATION OF SEWERS AND WATER MAINS: WATER MAINS SHALL AND LATERAL BREAKS TO THE FAYPWC PROJECT COORDINATOR. THE CONTRACTOR BE LAID AT LEAST 10 FEET LATERALLY FROM EXISTING OR PROPOSED SEWER SHALL INITIATE IMMEDIATE REPAIRS IN ACCORDANCE WITH FAYPWC STANDARDS. MAIN/LATERAL, UNLESS LOCAL CONDITIONS OR BARRIERS PREVENT A CONTRACTOR SHALL NOT OPERATE FAYPWC WATER MAIN VALVES WITHOUT 10-FOOT LATERAL SEPARATION - IN WHICH CASE: FAYPWC APPROVAL AND SHALL COORDINATE ALL VALVE CLOSINGS WITH FAYPWC. 2. THE CONTRACTOR SHALL NOT USE HOUSE HOSE BIBBS OR ANY OTHER METHOD OF i. THE WATER MAIN IS LAID IN A SEPARATE TRENCH WITH THE ELEVATION BLOW OFF WHICH ALLOWS DOMESTIC WATER CONTAINING SEDIMENTS OR HIGH OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 INCHES ABOVE THE LEVELS OF CHLORINE TO PASS THRU RESIDENT'S METERS. THE CONTRACTOR TOP OF THE SEWER MAIN/LATERAL OR SHALL BE RESPONSIBLE FOR ALL DAMAGES RESULTING FROM ALLOWING "DIRTY" WATER TO ENTER RESIDENT'S PLUMBING SYSTEM, SUCH AS WATER HEATERS, ii. THE WATER MAIN IS LAID IN THE SAME TRENCH AS THE SEWER STAINED CLOTHING, CLOGGED SCREENS, ETC. MAIN/LATERAL WITH THE WATER MAIN LOCATED AT ONE SIDE ON A 3. WATER MAINS AND LATERALS SHALL BE INSTALLED UTILIZING A FAYPWC APPROVED BENCH OF UNDISTURBED EARTH AND WITH THE ELEVATION OF THE CUT -SHEET INDICATING INSTALLATION DEPTH. BOTTOM OF THE WATER MAIN AT LEAST 18 INCHES ABOVE THE TOP OF 4. TRANSFER OF WATER SERVICES SHALL BE ACCOMPLISHED AS FOLLOWS: THE SEWER MAIN/LATERAL. A. INSTALL, TEST AND STERILIZE NEW MAIN AND LATERALS. LATERALS SHALL BE INSTALLED 18" INSIDE RIGHT-OF-WAY UNLESS OTHERWISE DIRECTED BY FAYPWC. B. CROSSING A WATER MAIN OVER A SEWER: WHENEVER IT IS NECESSARY FOR B. TRANSFER EXISTING METER TO NEW METER BOX AND TIE NEW WATER LATERAL A WATER MAIN TO CROSS OVER A SEWER MAIN/LATERAL, THE WATER MAIN TO EXISTING DOMESTIC SERVICE UTILIZING BRASS FITTINGS. SAME METER SHALL BE LAID AT SUCH AN ELEVATION THAT THE BOTTOM OF THE WATER NUMBER SHALL BE INSTALLED ON SAME ADDRESS AND/OR CUSTOMER. BLOW MAIN IS AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER MAIN/LATERAL , OFF SERVICE AT HOSE BIBB ON HOUSE ONLY AFTER METER HAS BEEN UNLESS LOCAL CONDITIONS OR BARRIERS PREVENT AN 18 INCH VERTICAL TRANSFERRED. SEPARATION - IN WHICH CASE BOTH THE WATER MAIN AND SEWER C. AFTER ALL SERVICES ARE TRANSFERRED TO THE NEW SYSTEM, SHUT OFF VALVE MAIN/LATERAL SHALL BE DUCTILE IRON IN ACCORDANCE WITH FAYPWC ON EXISTING SYSTEM AND ABANDON EXISTING MAINS IN ACCORDANCE WITH REQUIREMENTS. FAYPWC DETAILS. D. CONTRACTOR SHALL SUPPLY NEW METER BOXES AND DISPOSE OF EXISTING C. CROSSING WATER MAIN UNDER A SEWER: WHENEVER IT IS NECESSARY FOR METER BOXES. A WATER MAIN TO CROSS UNDER A SEWER MAIN/LATERAL, BOTH THE WATER MAIN AND THE SEWER MAIN/LATERAL SHALL BE DUCTILE IRON IN 5. WHEN MAIN IS NOT TO BE ABANDONED, CONTRACTOR SHALL UNCOVER OLD ACCORDANCE WITH FAYPWC REQUIREMENTS. A FULL JOINT OF DUCTILE IRON CORPORATION AT MAIN, CLOSE AND PLUG CORPORATION TO ABANDON OLD PIPE SHALL BE INSTALLED ON THE WATER MAIN CENTERED AT THE POINT OF SERVICE. CROSSING. 6. CONTRACTOR SHALL ABANDON ("KILL -OUT") ANY EXISTING WATER SERVICES THAT WILL NOT BE UTILIZED BY CUTTING THE SERVICE AT THE MAIN, PLUGGING THE D. CROSSING STORM DRAINAGE LINES: A MINIMUM OF 12-INCHES OF VERTICAL CORPORATION, AND TURNING OFF THE CORPORATION. AT THE METER BOX, THE CLEARANCE SHALL BE MAINTAINED BETWEEN A WATER LINE CROSSING OVER ABANDONED SERVICE IS TO BE CUT OR CRIMPED, AND BURIED A MINIMUM OF 3 FEET A STORM DRAINAGE LINE UNLESS DUCTILE IRON PIPE IS USED. IN ADDITION, BELOW GRADE. THREE AND A HALF (3.5) FEET OF COVER MUST BE MAINTAINED OVER THE 7. ALL EXISTING UTILITIES IMPACTED BY CONSTRUCTION SHALL BE ADJUSTED TO WATER MAIN OR IT SHALL BE DUCTILE IRON. IF DUCTILE IRON PIPE IS USED FINISHED GRADE, IN ACCORDANCE WITH FAYPWC REQUIREMENTS. THEN TWO AN A HALF 2.5 FEET OF COVER MUST BE MAINTAINED OVER THE ( ) 8. ALL WORK ON FAYPWC WATER UTILITIES (MAINS, LATERALS, ETC) SHALL BE WATER MAIN AND A MINIMUM OF 4-INCHES OF VERTICAL CLEARANCE SHALL PERFORMED BY A LICENSED UTILITY CONTRACTOR. THE FAYETTEVILLE PUBLIC BE MAINTAINED BETWEEN THE WATER MAIN AND THE STORM DRAINAGE LINE. WORKS COMMISSION SHALL OBSERVE AND APPROVE ALL WORK ON FAYPWC WATER WHERE A WATER MAIN CROSSES UNDER A STORM DRAINAGE LINE THE UTILITIES. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH FAYPWC MINIMUM OF TWELVE (12) INCHES OF VERTICAL SEPARATION SHALL BE REQUIREMENTS. MAINTAINED AND THE WATER MAIN SHALL BE DUCTILE IRON FOR A DISTANCE OF 10-FEET ON EACH SIDE OF THE CROSSING. FAYETTEVILLE NO. DATE REVISION WATER UTILITY NOTES PUBLIC WORKS COMMISSION FAYETTEVILLE, N.C. 1 07/11 REVISED NOTES AND ADDED NOTE 6 SHEET NO. DWG. NO. W.1 DWG. BY: FAYPWC WATER RESOURCES 2 07/01/16 ADDED NOTE 6 1 OF2 DATE: JAN. 01, 2020 APPROVED BY: J.E.G. ENGINEERING DEPARTMENT 3 01/01/18 ADDED NOTES 6,8 • • M'�ii -- i♦iiii ♦♦ii ♦ilii M;I► � ♦♦♦♦♦♦♦♦ISM M;i 'i�i♦�♦�•i�l�j wM t�,♦-� -♦-♦_♦ ♦- ♦_-♦_-♦__♦_-11 W 1-WATER-UTILITY-N OTES.dwg SIDE VIEW M SECTION A -A AI - II15-SOLID LID �UNDERERSIDE 1-INCH METER BOX LID FAYETTEVILLE NO. DATE REVISION PUBLIC WORKS COMMISSION N.T.S. FAYETTEVILLE, N.C. 1 07/07 REVISED LID SHEET NO. DWG. NO. WA DWG. BY: FAYPWC WATER RESOURCES 1 03/10 CHANGED BOX AND LID DIMENSIONS 2 OF 2 DATE: JAN. 01, 2020 APPROVED BY: J.E.G. ENGINEERING DEPARTMENT 2 01/15 REVISED LID NOTES: 1. FOR INSTALLATION RECOMMENDATIONS, SEE STD-702 "TYPICAL RET/DET CROSS-SECTION DETAIL" AND STD-703 "TYPICAL RET/DET/CLEANOUT DETAIL" W4-1 IN-METERBOX.dwg 10. WATER OUTAGES: THE CONTRACTOR SHALL SCHEDULE A COORDINATION MEETING WITH THE FAYPWC PROJECT COORDINATOR AND PROJECT ENGINEER A MINIMUM OF THREE 3 WORKING DAYS PRIOR TO ANY PLANNED WATER OUTAGE. THE COORDINATION MEETING SHALL BE CONDUCTED PRIOR TO ANY NOTICES BEING ISSUED. ADDITIONALLY, THE CONTRACTOR SHALL LOCATE (VERTICALLY AND HORIZONTALLY) ANY UTILITIES WITHIN THE WORK AREA, IN ACCORDANCE WITH THESE CONTRACT DOCUMENTS. THE LOCATIONS OF ALL UTILITIES WITHIN THE WORK AREA SHALL BE DETERMINED PRIOR TO THE COORDINATION MEETING. ANY CONFLICTS WITH THE PENDING WORK AND THE EXISTING UTILITIES SHALL BE IDENTIFIED AND A PLAN FOR RESOLVING ANY CONFLICTS SHALL BE PRESENTED. THE PURPOSE OF THIS COORDINATION MEETING IS TO ENSURE THAT THE CONTRACTOR HAS A GOOD UNDERSTANDING OF THE REQUIREMENTS RELATED TO THE PENDING OUTAGE, VERIFY THAT THERE ARE NO UTILITY CONFLICTS THAT WILL PREVENT THE WORK FROM BEING COMPLETED, ALL EQUIPMENT IS IN GOOD WORKING ORDER, ALL EQUIPMENT IS FUNCTIONAL, ALL MATERIALS ARE ON SITE, ALL NECESSARY TOOLS ARE ON SITE, DISCUSS ANY NECESSARY CONTINGENCY PLANS, AND ANY OTHER ITEMS NECESSARY TO ENSURE THAT THE FAYETTEVILLE PUBLIC WORKS COMMISSION HAS CONFIDENCE THAT THE WORK CAN BE ACCOMPLISHED WITHIN THE GIVEN TIME PERIOD. SHOULD, FOR ANY REASON, THE FAYETTEVILLE PUBLIC WORKS COMMISSION DEEM THAT THE CONTRACTOR IS NOT PREPARED FOR THE PROPOSED OUTAGE, THE OUTAGE NOTIFICATIONS WILL NOT BE DISTRIBUTED AND THE OUTAGE SHALL BE POSTPONED A MINIMUM OF TWO (2) WEEKS. THE FAYETTEVILLE PUBLIC WORKS COMMISSION WILL PROVIDE WRITTEN NOTIFICATION TO THE CONTRACTOR OF THIS DECISION. NO ADDITIONAL CONTRACT TIME WILL BE GRANTED FOR THIS DELAY. SHOULD THE CONTRACT TIME EXPIRE WITHIN THAT TWO (2) WEEK PERIOD, THE FAYETTEVILLE PUBLIC WORKS COMMISSION RESERVES THE RIGHT TO ASSESS LIQUIDATED DAMAGES AS OUTLINED IN THESE CONTRACT DOCUMENTS. ONCE THE WATER OUTAGE NOTIFICATIONS HAVE BEEN ISSUED, A FOLLOW-UP COORDINATION MEETING WITH THE FAYPWC PROJECT COORDINATOR AND PROJECT ENGINEER SHALL BE HELD A MINIMUM OF 24 HOURS PRIOR TO THE SCHEDULED OUTAGE. THE PURPOSE OF THIS MEETING IS TO VERIFY THAT THE CONTRACTOR IS PREPARED TO PROCEED WITH THE OUTAGE, AND THAT ALL EQUIPMENT, MATERIALS, TOOLS, AND ALL OTHER INCIDENTALS ARE ON THE PROJECT SITE AND FUNCTIONING. IF FOR ANY REASON THE FAYETTEVILLE PUBLIC WORKS COMMISSION DEEMS THAT THE CONTRACTOR IS NOT PREPARED THE OUTAGE SHALL BE POSTPONED AND ALL CUSTOMERS IMMEDIATELY NOTIFIED OF THE CANCELLATION. THE OUTAGE SHALL BE POSTPONED A MINIMUM OF TWO 2 WEEKS. NO ADDITIONAL CONTRACT TIME WILL BE GRANTED FOR THIS DELAY. SHOULD THE CONTRACT TIME EXPIRE WITHIN THAT TWO (2) WEEK PERIOD, THE FAYETTEVILLE PUBLIC WORKS COMMISSION RESERVES THE RIGHT TO ASSESS LIQUIDATED DAMAGES, AS OUTLINED IN THESE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL COMPLETE THE REQUIRED WORK AND RESTORE WATER SERVICE WITHIN THE GIVEN TIME PERIOD FOR THE OUTAGE. IF THE FAYPWC PROJECT COORDINATOR DETERMINES THAT THE CONTRACTOR WILL NOT RESTORE WATER SERVICE WITHIN THE APPROVED TIMEFRAME, THE FAYPWC PROJECT COORDINATOR WILL DIRECT THE CONTRACTOR ON HOW TO RESTORE WATER SERVICE. THE CONTRACTOR SHALL ADHERE TO ALL INSTRUCTIONS GIVEN BY THE FAYPWC PROJECT COORDINATOR. SHOULD THE CONTRACTOR FAIL TO COMPLETE THE WORK WITHIN THE ALLOTTED TIME THE FAYETTEVILLE PUBLIC WORKS COMMISSION SHALL ASSESS A PENALTY OF 500 PER 15-MINUTE INTERVAL OR ANY PORTION THEREOF UNTIL WATER SERVICE IS RESTORED. THIS PENALTY WILL BE DEDUCTED FROM THE CONTRACTOR'S PAY APPLICATION OR BE BILLED DIRECTLY TO THE CONTRACTOR. THE PENALTY MAY BE WAIVED FOR CIRCUMSTANCES BEYOND THE CONTRACTOR'S CONTROL, AS DEEMED BY THE FAYETTEVILLE PUBLIC WORKS COMMISSION. THE FAYPWC PROJECT COORDINATOR AND/OR PROJECT ENGINEER RESERVE THE RIGHT TO CANCEL OR POSTPONE THE OUTAGE AT ANY GIVEN TIME, IF DEEMED NECESSARY. FAYETTEVILLE NO. DATE REVISION WATER UTILITY NOTES PUBLIC WORKS COMMISSION FAYETTEVILLE, N.C. 1 07/11 REVISED NOTES AND ADDED NOTE 6 SHEET NO. DWG. NO. W.1 DWG. BY: FAYPWC WATER RESOURCES 2 07/01/16 ADDED NOTE 6 2 OF 2 DATE: JAN. 01, 2020 APPROVED BY: J.E.G. ENGINEERING DEPARTMENT 3 01/01/18 ADDED NOTES 6, 8 1'-fill (TYP.) wI z� 3"t1" FINAL GRADE I I �2i II w 5 - Q 11NM r�llll I - _I -I �I I i 4" = i#3 UNDISTURBED SOIL 7CU FT NO. 57 STONE PLACED TO A LEVEL 4" ABOVE DRAIN OPENING FAYPWC STANDARD PENTAGONAL OPERATING NUT OPEN COUNTER CLOCKWISE. (2) 2-1/2" NOZZLES AND (1) 4-1/2" NOZZLE WITH FIRE HOSE COUPLING THREAD IN ACCORDANCE WITH FAYPWC STANDARD. NOZZLE CAPS SHALL BE SECURELY CHAINED TO THE HYDRANTS BODY, I VALVE BOX 4-1/2" BARREL III- fill GATE I I- BRICK I -I I I- VALVE BII-III 1 1 b 1 1-1 1-1 �I 6" RJDI PIPE III -III ���I-IIII�II F I SEE NOTE NO. II- M.J. CONNECTION WITH IRON RETAINING GLAND M.J. RESTRAINT SEE NOTE 2 AND FAYPWC STANDARD RESTRAINING DETAIL. VARIES W 1-WATER-UTILITY-N OTES.dwg SEE CONCRETE THRUST BLOCK DETAIL - H E, HYDRANT TEE OR TAPPING SLEEVE AS REQUIRED. (SEE TAPPING DETAIL) FIRE HYDRANT AND FAYETTEVILLE NO. DATE REVISION VALVE INSTALLATION PUBLIC WORKS COMMISSION N.T.S. FAYETTEVILLE, N.C. 1 10/23/03 REVISED NOTE NO.4 DWG.NO. W. 13 1 DWG. BY: FAYPWC WATER RESOURCES 2 07/01/09 N0. AND ALTERED 1 EASED NOTE NO. RESTRAINT DETAIL REMOVED NOTE SHEET NO. 10F2 DATE: JAN. 01, 2020 APPROVEDBY: J.E.G. ENGINEERING DEPARTMENT 3 07/01/16 REVISED NOTES 1 ADDED ASTM F 2306 LEADER TJR 1 08/20/07 1 1 NOTE: ALL DIMENSIONS © 2007 ADS, INC. REV. DESCRIPTION BY MM/DD/YY CHK'D ARE t 1/2 FOOT. ADVANCED DRAINAGE SYSTEMS, INC. (°ADS") HAS PREPARED THIS DETAIL BASED ON INFORMATION PROVIDED TO ADS. THIS DRAWING IS INTENDED TO DEPICT THE DIA. DET/RET SYSTEM " TJR Q 1407 COMPONENTS AS REQUESTED. ADS HAS NOT PERFORMED ANY ENGINEERING OR DESIGN SERVICES FOR THIS PROJECT NOR HAS ADS INDEPENDENTLY VERIFIED 03 THE INFORMATION SUPPLIED. THE INSTALLATION DETAILS PROVIDED HEREIN ARE GENERAL RECOMMENDATIONS AND ARE NOT SPECIFIC FOR THIS PROJECT. THE "ro TYPICAL SUBSURFACE DET.\RET. 4640 TRUEMAN BLVD DESIGN ENGINEER SHALL REVIEW THESE DETAILS PRIOR TO CONSTRUCTION. IT IS THE DESIGN ENGINEERS RESPONSIBILITY TO ENSURE THE DETAILS PROVIDED HILLIARD, OHIO 43026 HERON MEETS OR EXCEEDS THE APPUCABLE NATIONAL, STATE, OR LOCAL REQUIREMENTS AND TO ENSURE THAT THE DETAILS PROVIDED HEREIN ARE ACCEPTABLE SYSTEM LAYOUT DETAIL FOR THIS PROJECT. ADVANCED DRAINAGE SYSTEMS, INC. NTS DRAWING NUMBER: STD-701 OF W13-FHCC.dwg METER BOX WITH NOTES: RECESSED AMR READING 1. ALL MATERIALS TO BE APPROVED BY LID SET 1/4" ABOVE GRADE FAYPWC. VARIE 18" 2. SERVICE LATERAL SIZE 1" IPS FINISHED GRADE v POLYETHYLENE UNLESS OTHERWISE i O SPECIFIED. Skrd1' 3. WATER SERVICE LOCK VALVE TO BE PAVEMENT 'r Q_ �Q. IA LOCATED 18" FROM SANITARY SEWER C•QNC. URB & GUTTER I A CLEANOUT STACK WHEN INSTALLED IN c0 C z SAME DITCH. ��- m 4. WHEN INSTALLED IN A PAVED AREA, METER BOX TO BE SET 1/4" ABOVE 1" FULL PORT ANGLE BALL VALVE - FINISHED PAVEMENT GRADES AND WITH ONE OR TWO STEP STYLE - PAVEMENT FEATHERED TO TOP OF BOX COMPRESSION FOR IPS PE INLET i - AND FEMALE METER THREAD = - TO PROVIDE DRAIN AWAY FROM BOX. z _ _ 5. COMPOSITE METER BOXES SHALL BE SWIVEL NUT WITH LOCK. ALL I III 1" SINGLE I1, fly _ , i USED IN TRAFFIC AREAS SEE FAYPWC STAINLESS STEEL INSERTS SHALL BE STAINLESS I I I STRAP SADDLE STEEL DETAIL W.48. t0 12" METER COUPLING 6. INSTALL NCDOT CONCRETE BRICK BASE WITH 3/4" FEMALE WITH NO GAPS. DO NOT LAY BRICK ON BALL CORPORATION STOP THREAD METER SWIVEL PIPE. SEE INSET "A". WITH AWWA INLETS, ONE NUT x 3/4" MIPT 7. WHERE ASPHALT CURB OR STRIP OR TWO STEP STYLE L1"x7-1/2" SPACER FOR PAVEMENT EXISTS, THE LOCATION OF BOX COMPRESSION FOR IPS PE DOMESTIC SERVICE SHALL BE AS DIRECTED BY FAYPWC WITH STAINLESS STEEL REPRESENTATIVE. 1"x10-3/4" SPACER FOR INSERTS IRRIGATION SERVICE, 8. DISTANCE FROM TOP OF LOCK VALVE 1" IPS POLYETHYLENE SPACER SHALL BE OPERATING STEM TO TOP OF BOX SHALL PIPE PE 4710, 250 PSI FURNISHED BY FAYPWC BE 8" MINIMUM TO 10" MAXIMUM. SIDR7 ASTM D2737 ASTM 9. RESIDENTIAL METER BOX SHALL BE SET D3350-445574E NCDOT CONCRETE BRICK 18" FROM R/W TO CENTERLINE OF METER 0 WATER METER BOX BASE SEE BOX PERPENDICULAR TO THE R/W. MAIN INSET "A" 10. COMMERCIAL METER BOX LOCATION SHALL BE AS APPROVED (PREFER NO TRACER WIRE 12 GA SINGLE STRAND METER BE INSTALLED LESS THAN 5' FROM (DO NOT CONNECT TO CORPORATION) COATED COPPER WIRE OR BUILDING TO EDGE OF BOX). NCDOT CONCRETE COPPER CLAD STEEL 11. LATERAL SHALL BE CENTERED ON LOT BRICK METER TRACING WIRE EXTENDED 18"UNLESS OTHERWISE NOTED. BACK FIL-D INTO METER BOX fill AND EQ EQ i 12. LATERAL SHALL NOT BE BACKFILLED UNTIL L V VALVE _ BOX BASE WRAPPED AROUND LOCK INSPECTED AND APPROVED BY FAYPWC METER BOX PROJECT COORDINATOR. NCDOT D BOTTOM "f1" 0 i 13. WATER MAIN AND LATERAL SHALL PASS HYDROSTATIC AND STERILIZATION TESTS. CONCRETE OF BOX . BRICK O 14BARB-TYPE FITTINGS ARE NOT 1"t1�� Ff al 15. SHOULD IT BE NECESSARY TO CRIMP THE BRICK METER BOX BASE SPACER SHALL WATER SERVICE LATERAL, A FULL CIRCLE SECTION "A -A" INSET "A" BE CENTERED REPAIR CLAMP SHALL BE PLACED ON THE PLAN IN METER BOX CRIMPED AREA. FAYETTEVILLE NO. DATE REVISION 1" WATER SERVICE LATERAL PUBLIC WORKS COMMISSION N.T.S. FAYETTEVILLE, N.C. 1 07/06 RESIZED METER COUPLING SHEET NO. DWG. NO. W.2 DWG. BY: FAYPWC WATER RESOURCES 2 07/13 REVISED NOTE RE: TRACER WIRE 10F1 DATE: JAN. 01, 2020 APPROVED BY: J.E.G. ENGINEERING DEPARTMENT 3 07/17 REVISED NOTES W2-WLAT.dwg NOTES: 1. FIRE HYDRANT SHALL BE MODELS MANUFACTURED BY MUELLER CO. (CENTURIAN), 10. CONTRACTOR SHALL NOTIFY THE APPROPRIATE FIRE DEPARTMENT OF OUT OF AMERICAN VALVE AND HYDRANT CO. (MODEL MARK 73), CLOW MEDALLION OR SERVICE FIRE HYDRANTS PRIOR TO CONSTRUCTION. APPROVED EQUAL. 11. FIRE HYDRANT SHALL BE FIELD PAINTED IN ACCORDANCE WITH FAYPWC 2. ALL VALVES AND HYDRANTS SHALL HAVE M.J. CONNECTIONS WITH IRON RETAINING STANDARDS, BEFORE PROJECT IS ACCEPTED. HYDRANTS SHALL BE PAINTED WITH GLAND M.J. RESTRAINT. A GREEN BONNET AND YELLOW BODY. PAINT SHALL BE IN ACCORDANCE WITH FAYPWC REQUIREMENTS. THE CONTRACTOR SHALL PAINT ALL EXPOSED 3. HYDRANT VALVE SHALL BE PLACED AS CLOSE AS POSSIBLE TO THE MAIN, BUT DO EXTERIOR FIRE HYDRANT SURFACES PRIOR TO FINAL ACCEPTANCE BY FAYPWC. NOT PLACE VALVE IN PROPOSED OR EXISTING CURB AND GUTTER. IF THE STREET ALL PAINTING SHALL BE DONE IN STRICT ACCORDANCE WITH THE PAINT IS SOIL AND NO PAVING IS TO BE DONE AT THIS TIME, THE LOCATION OF THE VALVE MANUFACTURER'S RECOMMENDATIONS AND SHALL BE SATISFACTORY TO THE IS TO BE DETERMINED BY THE FAYPWC PROJECT COORDINATOR. FAYPWC. 4. HYDRANT BRANCH SHALL NOT BE BACK FILLED UNTIL INSPECTED AND APPROVED 12. PROTECTIVE COVERING SHALL BE UTILIZED, AS NECESSARY FOR PROTECTION OF BY FAYPWC PROJECT COORDINATOR. ADJACENT AREAS, EQUIPMENT, SHRUBBERY, OR OTHER ITEMS. AFTER PAINTING IS COMPLETE, THE ENTIRE AREA SHALL BE THOROUGHLY CLEANED UP. 5. GATE VALVE AND BOX SHALL BE IN ACCORDANCE WITH FAYPWC STANDARD DETAIL. 13. ALL PAINT MATERIALS SHALL BE IN THE ORIGINAL SEALED CONTAINERS BEARING THE MANUFACTURER'S NAME. 6. HYDRANT EXTENSIONS AND/OR OFFSETS SHALL BE APPROVED BY FAYPWC PROJECT COORDINATOR. 14. WHERE NECESSARY, THINNING SHALL BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS, AND AS APPROVED BY FAYPWC. 7. FIRE HYDRANT CONNECTIONS TO EXISTING WATER MAINS SHALL BE MADE USING A TAPPING SLEEVE AND VALVE BY WET TAP CONNECTION. THE TAPPING SLEEVE 15. ALL SURFACES TO BE PAINTED SHALL BE CLEAN AND DRY. AND VALVE SHALL BE HYDROSTATICALLY TESTED PRIOR TO STARTING THE TAP IN THE PRESENCE OF THE FAYPWC PROJECT COORDINATOR. 16. THE BONNET OF THE FIRE HYDRANT SHALL BE PAINTED A DARK GREEN, UTILIZING AN ALKYD OR POLYURETHANE ENAMEL, WITH A FINAL DRY MIL THICKNESS OF 4 TO 8. THE PROPOSED LOCATION MAY BE RELOCATED BY THE FAYPWC PROJECT 6 MILS. MULTIPLE COATS MAYBE NECESSARY TO ACHIEVE THE FINAL REQUIRED COORDINATOR IF CONFLICTS EXIST (IE: GAS SERVICES, UGE, TELEPHONE, ETC.). DRY MIL THICKNESS. THE PAINT SHALL BE FOREST GREEN, AS MANUFACTURED BY THE SHERWIN-WILLIAMS COMPANY, PART NUMBER 822918, OR APPROVED EQUAL. 9. THE CONTRACTOR SHALL FIELD VERIFY THE EXISTING WATER MAIN MATERIAL, SAMPLES SHALL BE SUBMITTED IN ORDER FOR FAYPWC TO CONSIDER SIZE, AND DEPTH FOR EACH FIRE HYDRANT LOCATION PRIOR TO ORDERING ALTERNATIVE PAINT MANUFACTURERS. MATERIALS. THE CONTRACTOR WILL BE REQUIRED TO SUPPLY VARIOUS LENGTHS OF BARRELS AND HYDRANT EXTENSIONS (NO MORE THAN ONE HYDRANT 17. THE REMAINDER OF THE FIRE HYDRANT SHALL BE PAINTED SAFETY YELLOW, EXTENSION MAY BE USED PER HYDRANT). ADDITIONAL FITTINGS AND/OR HYDRANT UTILIZING AN ALKYD OR POLYURETHANE ENAMEL, WITH A FINAL DRY MIL EXTENSIONS OR OFFSET CONNECTORS MAY BE REQUIRED TO MAINTAIN PROPER THICKNESS OF 4 TO 6 MILS. MULTIPLE COATS MAY BE NECESSARY TO ACHIEVE COVER AS APPROVED BY THE FAYPWC PROJECT COORDINATOR. THE FINAL REQUIRED DRY MIL THICKNESS. THE PAINT SHALL BE YELLOW, AS MANUFACTURED BY THE SHERWIN-WILLIAMS COMPANY, PART NUMBER 3186, OR APPROVED EQUAL. SAMPLES SHALL BE SUBMITTED IN ORDER FOR FAYPWC TO CONSIDER ALTERNATE PAINT MANUFACTURERS. FIRE HYDRANT AND FAYETTEVILLE NO. DATE REVISION VALVE INSTALLATION PUBLIC WORKS COMMISSION N.T.S. FAYETTEVILLE, N.C. 1 10/23/03 REVISEDNOTENO.4 DWG. NO. W 13 DWG. BY: FAYPWC WATER RESOURCES 2 07/01/09 NO 3AND ALTERED REVISED NOTE NO. RESTRAINT DETAIL REMOVED NOTE SHEET NO. 20F2 DATE: JAN. 01, 2020 APPROVED BY: J.E.c. ENGINEERING DEPARTMENT 3 07/01/16 REVISED NOTES --------------------------------------------- H H (GRASS AREA) H I I (FLEX PVMT.) (RIGID PVMT.) FILTER FABRIC I I I 457 STONE BACKFILL OR ___ ___X SUPPLIER'S RECOMMENDEDATIO UNDISTURBED EARTH S CLASS I OR II MATERIAL T C ►, 4" WASHED J BEDDING (CLASS I OR II MATERIAL PLACED AND COMPACTED IN J = 4" MIN. FOR 12" - 24" PIPE ACCORDANCE WITH SUITABLE SAND = 6" MIN. FOR 30" - 60" PIPE NOTES: ASTM D2321 IN PIPE ZONE FOUNDATION 1. ALL REFERENCES TO CLASS I OR II MATERIAL ARE PER ASTM D2321 "STANDARD PRACTICE FOR UNDERGROUND INSTALLATION OF THERMOPLASTIC PIPE FOR SEWERS AND OTHER GRAVITY FLOW APPLICATIONS", LATEST EDITION. 2. ALL RETENTION AND DETENTION SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM D2321, LATEST EDITION AND THE MANUFACTURER'S PUBLISHED INSTALLATION GUIDELINES. 3. MEASURES SHOULD BE TAKEN TO PREVENT THE MIGRATION OF NATIVE FINES INTO THE BACKFILL MATERIAL, WHEN REQUIRED. SEE ASTM D2321. 4. FILTER FABRIC: A GEOTEXTILE FABRIC MAY BE USED AS SPECIFIED BY THE ENGINEER TO PREVENT THE MIGRATION OF FINES FROM THE NATIVE SOIL INTO THE SELECT BACKFILL MATERIAL. 5. FOUNDATION: WHERE THE TRENCH BOTTOM IS UNSTABLE, THE CONTRACTOR SHALL EXCAVATE TO A DEPTH REQUIRED BY THE ENGINEER AND REPLACE WITH SUITABLE MATERIAL AS SPECIFIED BY THE ENGINEER. AS AN ALTERNATIVE AND AT THE DISCRETION OF THE DESIGN ENGINEER, THE TRENCH BOTTOM MAY BE STABILIZED USING A GEOTEXTILE MATERIAL. 6. BEDDING: SUITABLE MATERIAL SHALL BE CLASS I OR II. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. UNLESS OTHERWISE NOTED BY THE ENGINEER, MINIMUM BEDDING THICKNESS SHALL BE 4" (100mm) FOR 4"-24" (100mm-600mm); 6" (150mm) FOR 30"-60" (750mm-900mm). 7. INITIAL BACKFILL: SUITABLE MATERIAL SHALL BE CLASS I OR II IN THE PIPE ZONE EXTENDING NOT LESS THAN 6" ABOVE CROWN OF PIPE. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. MATERIAL SHALL BE INSTALLED AS REQUIRED IN ASTM D2321, LATEST EDITION. NOMINAL NOMINAL TYPICAL TYPICAL TYPICAL SIDE H H DIAMETER 0. D. 3PACING "S SPACING "C' WALL "X" (NON -TRAFFIC (TRAFFIC) 12" 14.5" ill' 25.4" 8" 12" 12" 300 MM (368 MM) (279 MM) (645 MM) (203 MM) (292 MM) (292 MM) 15" 18" 12" 28.9" 8" 12" 12" 375 MM (457 MM) (292 MM) (734 MM) (203 MM) (292 MM) (292 MM) 18" 21 13" 33.9" 9" 12" 12" 450 MM (533 MM) (330 MM) (862 MM) (229 MM) (292 MM) (292 MM) 24" 28" 13" 40.7" loll 12" 12" 600 MM (711 MM) (330 MM) (1034 MM) (254 MM) (292 MM) (292 MM) 30" 36" 18" 53.1 " 18" 12" 12" 750 MM (914 MM) (457 MM) (1347 MM) (457 MM) (292 MM) (292 MM) 36" 42" 22" 63" 18" 12" 12" 900 MM 1067 MM) (559 MM) (1600 MM) (457 MM) (292 MM) (292 MM) 42" 48" 24" 71.9" 18" 12" 24" 1050 MM (1219 MM) (610 MM) (1826 MM) (457 MM) (292 MM) (610 MM) 48" 54" 25" 78.5" 18" 12" 24" 1200 MM (1372 MM) (635 MM) (1994 MM) (457 MM) (292 MM) (610 MM) 60" 67" 24" 90'" 18" 12" 24" 1500 MM (1702 MM) (610 MM) (2286 MM) (457 MM) (292 MM) (610 MM) 8. MINIMUM COVER: MINIMUM COVER OVER ALL RETNETION/DETENTION SYSTEMS IN NON -TRAFFIC APPLICATIONS (GRASS OR LANDSCAPE AREAS) IS 12" FROM TOP OF PIPE TO GROUND SURFACE. ADDITIONAL COVER MAY BE REQUIRED TO PREVENT FLOATATION. FOR TRAFFIC APPLICATIONS, MINIMUM COVER IS 12" UP TO 36" DIAMETER PIPE AND 24" OF COVER FOR 42" - 60" DIAMETER PIPE, MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT OR TO TOP OF RIGID 1 1 ADDED PIPE O.D. & "C" DIMENSION TJR 05/24/07 1 CKS NOTE: ALL DIMENSIONS PAVEMENT. © 2007 ADS, INC. REV. DESCRIPTION BY MM/DD/YY CHK'D ARE :I: 1/2 FOOT. ADVANCED DRAINAGE SYSTEMS, INC. ("ADS7 HAS PREPARED THIS DETAIL BASED ON INFORMATION PROVIDED TO ADS. THIS DRAWING IS INTENDED TO DEPICT THE DIA. DET/RET SYSTEM AWM COMPONENTS AS REQUESTED. ADS HAS NOT PERFORMED ANY ENGINEERING OR DESIGN SERVICES FOR THIS PROJECT NOR HAS ADS INDEPENDENTLY VERIFIED ' 07.25.06 THE INFORMATION SUPPLIED. THE INSTALLATION DETAILS PROVIDED HEREIN ARE GENERAL RECOMMENDATIONS AND ARE NOT SPECIFIC FOR THIS PROJECT. THE TYPICAL RET/DET 4640 TRUEMAN BLVD DESIGN ENGINEER SHALL RENEW THESE DEFAILS PRIOR TO CONSTRUCTION. IT IS THE DESIGN ENGINEERS RESPONSIBILITY TO ENSURE THE DETAILS PROVIDED HILLIARD, OHIO 43026 HEREIN MEETS OR EXCEEDS THE APPLICABLE NATIONAL, STATE, OR LOCAL REQUIREMENTS AND TO ENSURE THAT THE DETAILS PROVIDED HEREIN ARE ACCEPTABLE CROSS SECTION DETAIL Ems. FOR THIS PROJECT. ADVANCED DRAINAGE SYSTEMS, INC. NTS DRAWING NUMBER: STD-702 OF W13-FHCC.du * LOAD BEARING CONCRETE COLLAR AS SPECIFIED BY DESIGN ENGINEER (WHERE REQUIRED) UNDISTURBED EARTH NOTES: 1. ALL MATERIALS SHALL BE APPROVED BY FAYPWC. SEE DRAWING WA SHEET 2 OF 2 FOR METER BOX LID DETAIL. 2. METER BOX SHALL NOT BE LOCATED WHERE H-20 LOADINGS CAN IMPACT BOX OR COVER. 3. FOR 1" WATER LATERAL INSTALLATION SEE FAYPWC DETAIL W.2 m 4. DIMENSIONS _ 1/16 U.N.O. 0 TOP VIEW BOTTOM VIEW L PLAN 17-9/16" 12-5/16" ELEVATION Og ELEVATIONOA 1-INCH METER BOX DETAILS FAYETTEVILLE NO. DATE REVISION N.T.S. PUBLIC WORKS COMMISSION FAYETTEVILLE, N.C. 1 03/10 CHANGED BOX DIMENSIONS SHEET NO. DWG. NO. W4 DWG. BY: FAYPWC WATER RESOURCES 1oF2 DATE: JAN. 01,2020 APPROVED BY: J.E.G. ENGINEERING DEPARTMENT CLASS I OR II MATERIAL PER ASTM D2321, LATEST EDITION, COMPACTED IN MAX. 8" LOOSE 4" WASH7 ED LIFTS TO 95% MIN. OF MAX. SPD SAND SECTION A -A * LOAD BEARING CONCRETE COLLAR AS SPECIFIED BY DESIGN ENGINEER (WHERE REQUIRED) FRAME & GRATE (BY OTHERS) REFER TO STD-702 CORRUGATED HOPE RISER I FOR COVER HEIGHT (SPECIFY DIAMETER) DETAILS 4j LATERAL BEDDING (CLASS I OR II MATERIAL)' = 4" MIN. FOR 12" - 24" HOPE PIPE = 6" MIN. FOR 30"-60" HDPE PIPE (AS REQUIRED) STD-702 HEIGHT LS UNDISTURBED EARTH LATERAL I CLASS I OR II MATERIAL PER J BEDDING (CLASS I OR II MATERIAL) ASTM D2321, LATEST EDITION, = 4" MIN. FOR 12" - 24" HDPE PIPE COMPACTED IN MAX. 8" LOOSE 4" WASHED = 6" MIN. FOR 30"-60" HDPE PIPE LIFTS TO 95% MIN. OF MAX. SPD SAND SECTION B-B k LOAD BEARING CONCRETE COLLAR SHALL BE CONSTRUCTED IN TRAFFIC AREAS SUCH THAT THE LIVE LOAD IS TRANSMITTED TO THE SURROUNDING SOIL AND NOT DIRECTLY TO THE RISER. W4-11N-METERBOX.dwg CLASS I OR II MATERIAL PER ASTM D2321, LATEST EDITION, CLEANOUT COMPACTED IN MAX. 8" LOOSE UNDISTURBED LIFTS TO 95% MIN. OF MAX. SPD 1 UPDATED DRAWING TJR 03/13/07 1 CKS NOTE: ALL DIMENSIONS © 2007 ADS, INC. REV. DESCRIPTION BY MM/DD/YY CHK'D ARE t 1/2 FOOT. ADVANCED DRAINAGE SYSTEMS, INC. ("ADS HAS PREPARED THIS DETAIL BASED ON INFORMATION PROVIDED TO ADS. THIS DRAWING IS INTENDED TO DEPICT THE DIA. DET/RET SYSTEM " CRM COMPONENTS AS REQUESTED. ADS HAS NOT PERFORMED ANY ENGINEERING OR DESIGN SERVICES FOR THIS PROJECT, NOR HAS ADS INDEPENDENTLY VERIFIED ""•10/23 O6 THE INFORMATION SUPPLIED. THE INSTALLATION DETAILS PROVIDED HERON ARE GENERAL RECOMMENDATIONS AND ARE NOT SPECIFIC FOR THIS PROJECT. THE TYPICAL RET/DET N 4640 TRUEMAN BLVD DESIGN ENGINEER SHALL REVIEW THESE DETAILS PRIOR TO CONSTRUCTION. IT IS THE DESIGN ENGINEERS RESPONSIBILITY TO ENSURE THE DETAILS PROVIDED HILLIARD, OHIO 43026 HEREIN MEETS OR EXCEEDS THE APPLICABLE NATIONAL, STATE, OR LOCAL REQUIREMENTS AND TO ENSURE THAT THE DETAILS PROVIDED HERON ARE ACCEPTABLE RISER/CLEAN-OUT DETAIL • FOR THIS PROJECT. ,a,ANCm DRAINAM SYSTEVM •- NTS DRAWING NUMBER: STD-703 OF 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite 112, Fayetteville, NC 28306 office 910 426 6777 fax 30 426 5777 license number 23 I 9 b G 54 www.4Dsitesotutions.com REVISIONS ISSUED FOR CONSTRUCTION PROJECT NAME FAYETTEVILLE HONEYCUTT ROAD DOLLAR GENERAL STORM & WATER DETAILS CLIENT PAR 5 DEVELOPMENT GROUP, LLC 2075 Juniper Lake Road West End, North Carolina 27376 Phone: (910) 944-0881 PROJECT INFORMATION DESIGNED BY: SCOTT DRAWN BY: SCOTT CHECKED BY: CHRIS PROJECT NUMBER: 1485 DRAWING SCALE NOT TO SCALE DATE RELEASED MAY 4, 2020 SHEET NUMBER C-703 a- a v v0 Z N00 0 ==Z>M Z=OHO � Z -< � Cl) O z n Tn N Cv m -U z G) Z r = r = v rn z �D� m v N v D� 00 Z D ovz G) TI 00 M 4 W O SHEET 1 OF 1 840.16 v vM Z r Z O� 2 ==Z>M Z=OHO ng;0z >> r Z I' 1" DEPRESSION 4'_ 7 F/Q" 4'_ 7 G/Q" SECTION G-G 2'- 3 1/4" 1 3/16" 2" SECTION H-H PLAN WITH GRATE & FRAME REMOVED 1 1 /2" 1 1/2" M 1 5/8" 1 5/8" MI -I H FG o G O M 0 (V �0 a II N H M V-4 1 /2" V-7 5/8" 1'-7 5/8" PLAN OF GRATING CAST IRON 3'-6" F E E CO CV F 1/8" 1/8" 1/8" 1" 1" 1" 3'- 3 3/4" 1/8" 1/8" 1/8" 2 1/8" SECTION E-E v 2 1/8" CV N DROP INLET FRAME AND GRATE `"IEEP HOLES GENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL DROP INLETS OVER T-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT ol 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS FOR TO CONSTRUCT OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. CONSTRUCT WITH PIPE CROWNS MATCHING. SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATE NOT SHOWN. INSTALL 2" WEEP HOLES AS DIRECTED BY THE ENGINEER. INSTALL STONE DRAINS, OF A MINIMUM OF 1 CUBIC FOOT OF NO. 78M STONE IN A POROUS FABRIC BAG OR WRAP, AT EACH WEEP HOLE OR AS DIRECTED BY THE ENGINEER. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. PLAN OF FRAME CASTIRON ;i/42' 2 /4 �� ninn <V SECTION F-F BRICK COPING (INCIDENTAL) m n Z TOP ELEVATION 0 0 STD. 540.16 FRAME - Z N & GRATE N Cl) 6" A 6" M a _ v �rn> v M Dno m Z E-F SEE NOTE DOWEL (SEE NOTE) z rn 0 SECTION X-X O SHEET1 OF 1 840.14 n m Z �Z� n Fn x ; _ D x � M z v y C X r Z v n v m x O 0 Z z m W -n 00 X SHEETI OF 1 840.31 � T #4 BAR B 6" T 1 = N DOWEL MAX PIPE THIS SIDE -- 1 SECTION Y-Y DIMENSIONS AND QUANTITIES FOR DROP INLET (BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX & PIPE CUBIC YARDS CONC. IN BOX DEDUCTIONS FOR ONE PIPE PIPE SPAN WIDTH MIN. HEIGHT D A B H BOTTOM SLAB WALL PER FT. HT. CONCRETE FOR O MNTMHM HEIG12" C.M. R.C. T-0" 2'-0" 2'-0" 0.222 0.222 0.592 0.015 0.026 15" 2'-3"e 0.648 0.023 0.036 18" 2'-6" 0.703 0.033 0.049 24" T-0" 0.814 0.059 0.085 30" T-0" 2'-0" 2'-6" 0.222 0.222 0.925 0.092 0.127 CONCRETE DROP INLET F MANHOLE E GENERAL NOTES: C CHAMFER ALL EXPOSED CORNERS 1". j USE CLASS "B" CONCRETE THROUGHOUT. L OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR FT D D #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. Q _ USE FORMS TO CONSTRUCT THE BOTTOM SLAB. p U M IF REINFORCED CONCRETE PIPE IS SET IN BASE SLAB OF BOX, Of0O ADD TO BASE AS SHOWN ON STANDARD NO. 840.00. 20Q PROVIDE ALL JUNCTION BOXES OVER 3'-6" IN DEPTH WITH STEPS U U 12" ON CENTER IN ACCORDANCE WITH STD. NO. 840.66. ADJUST THE STEEL, CONCRETE AND BRICK MASONRY QUANTITIES TO INCLUDE THE ADDITION OF THE MANHOLE (I.E. DIAGONAL BARS 3 SHORTENED AROUND OPENING IN TOP SLAB, ADDITIONAL VARIABLE ih HEIGHT BRICK MASONRY, OPENING IN TOP SLAB.) ., ..,.54 C MAX. DEPTH OF THIS STRUCTURE FROM TOP OF BOTTOM SLAB TO TOP PLAN FOR MANHOLE COVER & FRAME #4 BARS "A" ELEVATION IS 12 FEET. OPTIONAL SPACED C. TO C. BRICK MAY BE USED 6„ y1/4 TO ADJUST FRAME & COVER TO SURFACE ELEVATION MAX. 1' #4 BAR a OUTLET PIPE E OR F1/2" A 61 6LLL SECTION DOWEL C-C OR D-D SECTION X-X 6" j1/4 6" 6" SECTION Y-Y DIMENSIONS AND QUANTITIES FOR CONCRETE JUNCTION BOXES DIMENSIONS OF BOX AND PIPE REINFORCEMENT BARS "A" TOP SLAB DIMENSIONS CUBIC YARDS IN BOX TOTAL QUANTITIES BOX AND SLAB DIMENSIONS FOR ONE PIPE CU. YDS. PIPE SPAN WIDTH HEIGHT D A B H NO. LENGTH E F TOP SLAB BOTTOM SLAB WALL/ FT. OF HT. LBS. REINF CU. YDS. MIN. "H" C.S. R.C. 12" 2'-0" 2'-0" 2'-3" 12" 2'-9" T-0" T-0" 0.167 0.167 0.185 22 0.750 0.015 0.024 15" 2'-3" 2'-3" 2'-6" 12" T-0" 3'-3" 3'-3" 0.196 0.196 0.204 24 0.902 0.023 0.036 18" 2'-6" 2'-6" 2'-9" 14" 3'-3" T-6" T-6" 0.227 0.227 0.222 30 1.065 0.033 0.049 24" T-0" T-0" 3'-3" 16" T-9" 4'-0" 4'-0" 0.296 0.296 0.259 40 1.434 0.059 0.085 30" T-6" T-6" 3'-9" 18" 4'-3" 4'-6" 4'-6" 0.375 0.375 0.296 51 1.860 0.092 0.127 36" 4'-0" 4'-0" 4'-3" 20" 4'-9" 5'-0" 5'-0" 0.463 0.463 0.333 64 2.341 0.132 0.178 42" 4'-6" 4'-6" 4'-9" 22" 5'-3" 5'-6" 5'-6" 0.560 0.560 0.370 77 2.878 0.180 0.243 48" 5'-4" 5'-4" 5'-3" 26" 6'-3" 6'-4" 6'-4" 0.743 0.743 0.407 111 3.623 0.235 0.317 54" 5'-10" 5'-10" 5'-9" 28" 6'-7" 6'-10" 6'-10" 0.865 0.865 0.444 126 4.283 0.297 0.401 60" 6'-6" 6'-6" 6'-3" 30" T-3" 7'-6" 7'-6" 1.042 1.042 0.481 145 5.090 0.367 0.495 66" 7'-1" T-1" 6'-9" 32" T-10" 8'-1" 8'-1" 1.210 1.210 0.518 169 5.917 0.444 0.589 z O (n Q � Q Z U OpaOz (n x HVaLL0 LU cf) z J WLLO_Q 00(n� v zap W o r LU O 0 H O z p o wa°° o N W 0 � o a L o W N L J H J Z _ z IL LU 0LU p � O LL SHEET 1 OF 1 840.16 NTS z O (n Q < Q LL�0O=V OOaOZ (n x W Q Z x H0<LLCD �LU ZJ WLLOQ OOcnW v za> 1LU � o 0 0 W z J Z LU � a a o CCD � p = Qp W W z Ill- x Q W F- (j cV (1) z JO 0U z W SHEET 1 OF 1 840.14 NTS z 0 Q Q Q LLJO=U ODawu)- Z x = � 0 W cl) z WLLO� O O (n N za_-LLI o O X LL m O W Z Z J O 0 x W ~a CL o C) M a o Z J o �o w Q ~a ~ (n W x H J Z 0 0 Z C) W SHEET I OF 1 840.31 NTS m z G) N i ! 0 --1 -4 X Z v v C I0 > o 0 v v m r -n X SHEET 1 OF 1 840.15 v vM Z r Z O� 2 0) = = Z > 1711 z=Or-O ng�z >D �z D z Za = r O Cl) r = rn� -n Z v v rn v v* n z 00 <-n rn0 X ;0 1►MA PLAN WITH COPING REMOVED SECTION X-X GENERAL NOTES: MORTAR JOINTS 1/2" ± 1/8" THICK. USE CLASS "B" CONCRETE THROUGHOUT. USE FORMS FOR CONSTRUCTION OF THE BOTTOM SLAB. USE #4 BAR DOWELS AT 12" CENTERS. f DEDUCT FOR PIPE(S) FROM TOTAL CU. YDS. OF BRICK MASONRY. PROVIDE ALL CATCH BASINS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. USE BRICK OR CONCRETE BLOCK WHICH COMPLIES WITH THE REQUIREMENTS OF SECTION 840 OF THE STANDARD SPECIFICATIONS. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. FOR 8'-0" IN HEIGHT OR LESS, USE 8" WALL. OVER 8'-0" IN HEIGHT, USE 12" WALL TO 6'-0" FROM TOP OF WALL, AND 8" WALL FOR THE REMAINING 6'-0". QUANTITIES TO BE ADJUSTED ACCORDINGLY. CONSTRUCT WITH PIPE CROWNS MATCHING. SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES. DO NOT USE BRICK MASONRY DROP INLET IN LOCATIONS SUBJECT TO TRAFFIC. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NO TO SCALE. -;OPING (INCIE �Mi Al OP ELEVATIO STD. 540.16 RAME & GRAI MAX PIPE THIS SIDE -- 18" 1I DIMENSIONS AND QUANTITIES FOR DROP INLET (BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX & PIPE CUBIC YARDS CONCRETE CUBIC YARDS BRICK MASONRY DEDUCTIONS FOR ONE PIPE PIPE SPAN WIDTH MIN. HEIGHT D A B H BOTTOM SLAB WALL PER FOOT HT. TOTAL BRICK MASONRY FOR MIN. HEIGHT, H C.S. R.C. 12" T-0" 2'-0" 2'-0" 0.268 0.313 0.522 0.020 0.032 15" 2'-3" 0.268 0.313 0.600 0.031 0.047 18" 2'-6" 0.268 0.313 0.678 0.044 0.065 24" T-0" 0.268 0.313 0.835 0.078 0.113 30" T-0" 2'-0" 2'-6" 0.268 0.313 0.991 0.122 0.170 PLAN OF FRAME 2'-1 1/4" - 1'-11 3/4" - V-10 7/8" - cN T BRICK DROP INLET T #4 BAR I i SOLID COVER SHOWN PERFORATED. PERFORATED AVAILABLE IF SPECIFIED. STATE USE OF SYSTEM ON COVER (I.E.: SEWER, STORM DRAIN, ELECTRICAL) TOP OF COVER BOTTOM OF CC PLAN OF COVER 1'-11 1 /2" 3/4" � 22 N M M TYPE #1 3 3/4" 1/2' �4 3/4" 1'-10 5/8" ALTERNATE SECTION B-B 1" R. 4 3/8" 2'-0 1/2" MINIMUM WEIGHTS - LBS. 2'-9 1/4" FRAME - 180 COVER - 120 SECTION A -A TOTAL - 300 z O (n QaQ Z � U OpaOz �(nx HVaLLO fAH�ZJ WLLO_Q 00(n� za> 1 LLI o 0 LL Z w � J a o a a 00CD M o � � Z = Q Y () U04 J Ln m 0 Z W SHEET 1 OF 1 840.15 NTS z O (n QQQ Z ~ LL JOx - ODaOz =(nx W Q Z x HVQLL0 =�0W (nHZJ WLLOQ OOcn� za> W o I o W O > Z O z o QQ LU Q G o Z LL H W W = J (n O zz W TYPE #2 SHEET 1 OF 1 SHEET 1 OF 1 840.54 840.54 MANHOLE FRAME AND COVER NTS v E GENERAL NOTES: Z m A CHAMFER ALL EXPOSED CORNERS 1" 0 Z 8" 8" -OPTIONAL MANHOLE E USE CLASS "B" CONCRETE THROUGHOUT. USE #4 BAR DOWELS AT 12" CENTERS. Q Q Q 0 0 0 Y 8 C Z � D � MORTAR JOINTS 1/2" ± 1/8" THICK. w () = (n I 1 CONCAVE TOO ALL EXPOSED JOINTS. LL O 0 Z mZ x 0 D > X X USE FORMS TO CONSTRUCT THE BOTTOM SLAB. 0 0 d - W Z x = C-) = m D M D JUMBO BRICK WILL BE PERMITTED. CONCRETE BRICK OR 4" BE USED L LIEU FOCLNY BRICK. Q A V O W y Z G) O O m Q Cr 0 UO FORIB=OOINCRETE HEIGHBOR LESSLOCKS , USE 8" WALY OVER g HEIGHT, USE 12" WALL TO 6'-0" FROM TOP OF WALL, AND 8" WALL N t- Z J c C Q U F-D u FOR THE REMAINING 6'-0". ADJUST DIMENSIONS AND QUANTITIES w LL 0 z Z m d U ACCORDINGLY. O O (n D D �_ � IF REINFORCED CONCRETE PIPE IS SET IN BASE SLAB OF BOX, Z > ADD TO BASE AS SHOWN ON STANDARD NO. 840.00. CL In 0 PROVIDE ALL JUNCTION BOXES OVER T-6" IN DEPTH WITH STEPS LLI Z 8" 1/ " I �,., �I 3" � C 12" ON CENTER IN ACCORDANCE WITH STD. NO. 840.66. ADJUST THE STEEL, CONCRETE AND BRICK MASONRY QUANTITIES 0 #4 BARS "A" TO INCLUDE THE ADDITION OF THE MANHOLE (I.E. DIAGONAL BARS PLAN SEE STANDARD 840.54 SPACED SHORTENED AROUND OPENING IN TOP SLAB, ADDITIONAL VARIABLE FOR MANHOLE COVER &FRAME C. C. TO C. HEIGHT BRICK MASONRY, OPENING IN TOP SLAB. ) OPTIONAL MAX. DEPTH OF THIS STRUCTURE FROM TOP OF BOTTOM SLAB TO TOP BRICK MAY BE USED TO ELEVATION IS 12 FEET. ADJUST FRAME &COVER DODO u KA � � r Cn x 0 :c N 0 X � -0 C- z c z Z D � n v -0 Z O D Z m O W z mO0 .� X O SHEET 1 OF 1 840.32 6 TO SURFACE ELEVATION MAX. 1 HEADER COURSES 1/4" a OUTLET PIPE o A � SECTION X-X SEE STANDARD 840.54 FOR MANHOLE COVER &FRAME BRICK MAY USED TO ADJUST FRAME &COVER 6" TO SURFACE ELEVATION MAX. 1' 1/4" X 8" EXP. JOINT 1/4" g^ 6" � x B 6" 3" f DOWEL SECTION Y-Y ❑® O ❑ #4 BAR ❑❑ ®❑ _ ❑ ❑ N 6 E OR F 1/2" �B+16� SECTION DIMENSIONS AND QUANTITIES FOR BRICK JUNCTION BOXES DIMENSIONS OF BOX AND PIPE REINFORCEMENT BARS TOP SLAB DIMENSIONS CUBIC YARDS M&ffiMS11ONS FOR�NE QV1.YiL9S. PIPE SPAN WIDTH HEIGHT CONC. BRICK MASONRY D A B H NO. LENGTH E F TOP & BOTTOM CU. YD. MIN HEIGHT CU. YD. WALL PER FT. HT. CU. YD. C.S. R.C. 12" 2'-0" 2'-0" 2'-3" 12" T-1" 3'-4" 3'-4" 0.412 0.591 0.263 0.020 0.032 15" 2'-3" 2'-3" 2'-6" 12" T-1" 3'-4" 3'-4" 0.412 0.657 0.263 0.031 0.047 18" 2'-6" 2'-6" 2'-9" 14" T-5" T-8" T-8" 0.498 0.814 0.296 0.044 0.065 24" T-0" T-0" 3'-3" 16" 4'-1" 4'-4" 4'-4" 0.695 1.176 0.362 0.078 0.113 30" 3'-6" T-6" 3'-9" 18" 4'-5" 4'-8" 4'-8" 0.807 1.481 0.395 0.122 0.170 36" 4'-0" 4'-0" 4'-3" 20" 5'-1" 5'-4" 5'-4" 1.053 1.959 0.461 0.176 0.238 42" 4'-6" 4'-6" 4'-9" 22" 5'-9" 6'-0" 6'-0" 1.333 2.503 0.527 0.240 0.323 48" 5'-4" 5'-4" 5'-3" 26" 6'-5" 6'-8" 6'-8" 1.646 2.940 0.560 0.313 0.422 54" 5'-10" 5'-10" 5'-9" 28" 6'-11" T-2" T-2" 1.902 3.502 0.609 0.396 0.535 60" 6'-6" 6'-6" 6'-3" 30" T-7" T-10" T-10" 2.272 4.113 0.658 0.489 0.660 66" T-1" T-1" 6'-9" 32" 8'-2" 8'-5" 8'-5" 2.624 4.778 0.708 0.591 0.798 w 0 LL x -- a0LU co 0 Z z (L o< FL J � z Z z o Z � 0 x Q a (i Y O N x V x W J m z W SHEET 1 OF 1 840.32 NTS site solutions civil engineering I land surveying 409 Chicago Drive, Suite 112, Fayetteville, NC 28306 office 910-426-6777 fax 1910-426-5777 license number I C-2354 www.4Dsitesotutions.com �CARO,���'' SEA 02 G I N V ••.....•• �O REVISIONS ISSUED FOR CONSTRUCTION PROJECT NAME FAYETTEVILLE HONEYCUTT ROAD DOLLAR GENERAL STORM DETAILS CLIENT PAR 5 DEVELOPMENT GROUP, LLC 2075 Juniper Lake Road West End, North Carolina 27376 Phone: (910) 944-0881 PROJECT INFORMATION DESIGNED BY: SCOTT DRAWN BY: SCOTT CHECKED BY: CHRIS PROJECT NUMBER: 1485 DRAWING SCALE NOT TO SCALE DATE RELEASED MAY 4, 2020 SHEET NUMBER C-704 CONCRETE JUNCTION BOX BRICK JUNCTION BOX