Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WI0400391_DEEMED FILES_20150608
)_ \ ~ ~Ro gers, Michael From: JeffGerlock ·<jeff.gerlock@gmaiLcon,> Monday, June 08, 2015 1 :54 PM Rogers, Michael Sent: To: Cc: Heery, Jim; Jim Heery Subject: Re: WI0400391 NOi -RE: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC Attachments: Fiber-injection report-2015.pdf Mike, we performed the remediation injection activities at the site from May 18 to 20, 2015. attached is a brief report including the well construction / abandonment records. please let me know if you have any questions or if you need additional information. thanks! Note -please respond to this email to let me know that you received it and the report. On Tue, Apr 14, 2015 at 2:07 PM, Rogers, Michael <michael.ro ir ers (a),ncdenr.2.ov> wrote: Thank you for submitting the Notice of Intent to Construct or Operate Injection Wells (NOi) at the Fiber Dynamics Facility. This facility is located at 200 South West Point Ave., High Point, Guilford County, NC 27261. We received your complete NOi on April 13, 2015. Please remember to submit the following regarding this injection activity: 1) Well Construction Records {GW-1} and Abandonment Records (GW-30) when completed. Please provide copies of the GW-ls and GW-30s if not already submitted (originals go the address printed on the form). NOTE: Direct push or Geoprobe wells are considered wells and require construction (GW-l)·and abandonment forms (GW-30). If well construction/abandonment information is the same for the wells, only one form needs to be completed-just indicate total number of injection points in the Comments/Remarks section of form. These forms can be found on our website at http://portal.ncdenr.org/web/wq/aps/gwpro/reporting-forms. 2) Injection Event Records (IER). All injections, including air and passive systems require an IER. The IER can be modified for air sparge wells (e.g., air flow 'continuous' for date or rate of injection, etc.). You can scan and send these forms directly to me at michael.rogers @ncdenr.gov, send by fax to my attention at 919- 807-6406, or via regular mail to address below. When submitting the above forms, you will need to enter the nine-digit alpha-numeric number on the form (i.e., WI0XXXXXX) that has been assigned to the injection activity at this site. This notification has been given the deemed permit numberWI0400391. This number is also referenced in the subject line of this email. You may if you wish, scan and send back as attachments in re p ly to this email. as it will already have the assigned deemed permit number in the subject line. Thank you for your cooperation. 1 Michael Rogers, P.G. (NC & FL) Hydrogeologist NCDENR-DWR Water Quality Regional Operations Section 1636 Mail Service Center Raleigh, NC 27699 Direct No. 919-807-6406 http://portal.ncdenr.org/web/wq/aps/gwpro/reporting-forms NOTE: Per Executive Order No. 150, all e-mails sent to and from this account are subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Jeff Gerlock [mailto:jeff.gerlock@gmail.com] Sent: Monday, April 13, 2015 1:16 PM To: Rogers, Michael Cc: Slusser, Thomas Subject: Re: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC here is a summary table to help show you the information. let me know if you need anything else. On Mon, Apr 13, 2015 at 11:49 AM, Jeff Gerlock <ieff.2.erlock(@g mail.com> wrote: Good morning Mike; hope you had a nice weekend. just wanted to check in with you on your email request for info on the proposed injection at Fiber Dynamics in High Point. the information requested in your email on April 1st is included in our application (page 3). Geoprobe borings will be drilled to auger refusal/ top of rock expected at 11 to 21 feet and then HRC will be injected through the rods from the bottom of each boring to the water surface. intervals are shown in the application. we will use the recommended 6 lbs per foot of HRC at each borehole. there is no water added to the HRC. a schematic of the geoprobe locations/ areas and depths is shown on the cross section attached to the application. we may also inject 3-D ME into the bottom 10 foot of well DW-1 at a rate of2.4 gallons per foot 2 or 24 gal / 200 lbs total of material at a 10 % dilution rate therefore we will mix the 3D ME with 240 gallons of water. MSDS forms for the two chemicals are attached. let me know if you need me to prepare a table, figure, or provide other information for t11e_proposed work at the site. On Wed, Apr 1, 2015 at 3:15 PM, Rogers, Michael <michael.ro gers @ncdenr.gov> wrote: Would you please provide a total estimated average on the total amount of injectant plus chase water you are going to inject at each proposed Geoprobe (in gallons}, and at DW-1. Additionally, would you proved a schematic of proposed Geoprobe with total depth. We realize this is proposed and actual depth will vary a little at each point. Thanks From: Jeff Gerlock [mailto:jeff.gerlock@gmail.com] Sent: Monday, March 30, 2015 12:56 PM To: Rogers, Michael Cc: Slusser, Thomas Subject: Re: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC I understand -we were not planning to do the work for about a month or so. just wanted to make sure you have all the paperwork and answers you need to process. On Mon. Mar 30. 2015 at 12:54 PM, Rogers, Michael <michael.ro uers(w,ncdenr.gov> wrote: NO, not yet. We need to review and process, enter project into our system, and forward a copy to the regional office for their review. That's why we require a 2-week notice before injection activities. From: Jeff Gerlock [mailto:jeff.gerlock@gmail.com] Sent: Monday, March 30, 2015 10:14 AM To: Slusser, Thomas; Rogers, Mike; Rogers, Michael Subject: Re: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC 3 sounds good. so is everything complete and all look fine to order the materials and proceed with our pilot test? On Mon, Mar 30, 2015 at 10:08 AM, Slusser, Thomas <thomas.slusser/a),ncdem.izov> wrote: Greetings Jeff, Thanks for the submittal. Mike Rogers, copied on this email, will be your project contact for this one. Take care, -Thomas Slusser, L.G. Underground Injection Control Program Manager thomas.slusser@ncdenr.g ov I ph# 919-807-6412 I fax# 919-807-6496 Mailing Address: NCDENR Division of Water Resources I 1636 Mail Service Center I Raleigh, NC 27699-1636. Physical Address: Room 640M, Archdale Building, 512 N. Salisbury St., Raleigh, NC 27604. Internet Address: http://portal.ncdenr.org/web/wq/ap s/gw 9 ro E-mail correspondence tn and from this address may be subject tn the lvnrth Carolina Public Records Law and may be disclosed tn third parties unless the content is exempt by statute or other regulation. From: Jeff Gerlock [mailto:i eff.gerlock@gmail.com] Sent: Friday, March 27, 2015 5:42 PM To: Slusser, Thomas Subject: Re: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC Good afternoon Thomas. hope you are having a good Friday. attached is our revised NOI for injection at the site. please review and call if you have any questions and/or if you need any clarification or other infonnation. thanks. 4 Note -please respond to let me know that you received this email and the attachments. On Thu, Mar 12, 2015 at 1:56 PM, Slusser, Thomas <thomas.slussert@ ncdenr.gov> wrote: Thanks Jeff for the update. Let me know if you have any questions for me as you move forward with this. Take care, -Thomas Slusser, LG. Underground Injection Control Program Manager thomas.slusser@ncdenr.gov I ph# 919-807-6412 I fax# 919-807-6496 Mailing Address: NCDENR Division of Water Resources I 1636 Mail Service Center I Raleigh, NC 27699-1636. Physical Address: Room 640M, Archdale Building, 512 N. Salisbury St., Raleigh, NC 27604. Internet Address: http:llp ortal.ncdenr.orglweblwqla pslgwpro E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. From: Jeff Gerlock [mailto:jeff.gerlock@gmail.com] Sent: Thursday, March 12, 2015 11:16 AM To: Slusser, Thomas Subject: Re: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC sorry I forgot to get back with you on this matter. I have recently revised our remediation plan and injection strategy after further discussions with my supplier. I will make the change you suggested and our changes and resubmit the plan this week. thanks for your follow up! On Tue, Mar 3, 2015 at 12:52 PM, Slusser, Thomas <thomas.slusser _ ncdenr.12ov> wrote: Greetings Jeff, I have not yet received the revised NOI for this project. Have you submitted it yet? 5 Thanks, -Thomas Slusser, L.G. Underground Injection Control Program Manager thomas.slusser@ncdenr.g ov I ph# 919-807-6412 I fa x# 91 9-80 7-6496 Mailing Address: NCDENR Divisio n of Water Resources I 1636 Mail Service Center I Raleigh, NC 27699-1636. Physical Address: Room 640M, Archdale Building, 512 N . Salisbury St., Raleigh, NC 27604 . Internet Address: http://portal.ncdenr.org/web/wq/aps/gwpro E-mail correspof7def7ce to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to thi,•d parties unless the content is exempt by statute or other regulation. From: Slusser, Thomas Sent: Tuesday, February 17, 2015 1:40 PM To: Jeff Gerlock Subject: RE: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC Greetings Jeff, I looked at the submittal and everything looks good, but I did not see a table or diagram of well construction information as asked for in Part K(2). Otherwise, everything is fine. Thank you, ~ Thomas Slusser, L.G. Underground Injection Control Program Manager NC Division of Water Resources ph# 919-807-6412 http: //porta I. ncdenr .org/web/wq/a ps/gwpro 1636 Mail Service Center Raleigh, NC 27699-1636 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. 6 From: Jeff Gerlock [ieff.gerlock@gmail.com] Sent: Monday, February 16, 2015 5:10 PM To: Slusser, Thomas Subject: Request for Approval of Small-Scale Injection Operation -Fioer Dyhamics, High Point, NC Thomas, per our conversation this morning attached is our application/ NOI for the project. please review and let me know if we need to modify or include additional information. thanks for your help. Note -please respond to let me know that you received it. Jeff Gerlock Blue Ridge Geological Services 306 Eden Terrace, Suite C Archdale, NC 27263 336-431-5454 office phone and fax Jeff Gerlock Blue Ridge Geological Services 306 Eden Terrace, Suite C Archdale, North Carolina 27263 336-431-5454 office phone and fax www.blueridgegeo.com Jeff Gerlock Blue Ridge Geological Services 7 306 Eden Terrace, Suite C Archdale, North Carolina 27263 336-431-5454 office phone and fax www.blueridgegeo.com Jeff Gerlock Blue Ridge Geological Services 306 Eden Terrace, Suite C Archdale, North Carolina 27263 336-431-5454 office phone and fax www.blueridge geo.com Jeff Gerlock Blue Ridge Geological Services 306 Eden Terrace, Suite C Archdale, North Carolina 27263 336-431-5454 office phone and fax www.blueridgegeo.com 8 ... , .:,··,.~·· .. Jeff Gerlock Blue Ridge Geological Services 306 Eden Terrace, Suite C Archdale, North Carolina 27263 336-431-5454 office phone and fax www.blueridge geo.com Jeff Gerlock Blue Ridge Geological Services 306 Eden Terrace, Suite C Archdale, North Carolina 27263 336~431-5454 office phone and fax www.blueridgegeo.com Jeff Gerlock Blue Ridge Geological Services 306 Eden Terrace, Suite C Archdale, North Carolina 27263 336-431-5454 office phone and fax www.blueridge geo.com 9 June 8, 2015 Mr. Michael Rogers NCDENR Division of Water Resources-Water Quality Regional Operations Section 1636 Mail Service Center Raleigh, North Carolina 27699-1636 Subject: Injection Well Construction/ Abandonment Information Fiber Dynamics, Inc. 200 South West Point Avenue High Point, Guilford County, North Carolina NCDENR Permit #WI0400391 NCDENR Site ID#NON CD 0002854 Dear Mr. Rogers: As authorized, Blue Ridge Geological Services, Inc. (Blue Ridge) and its subcontracted driller performed remediation activities at the subject site in 2015. On May 18 and 19, 2015 we drilled 19 borings around monitoring wells MW-3, MW-4, MW-5, MW-6, and MW-7 using a Geoprobe and then injected remediation media into the borings through the hollow drill rods. A map showing the boring/ injection point locations is attached . A total of 1,380 gallons of Hydrogen Release Compound (HRC) was injected into the borings / injection points; a table summarizing the information on each injection point is attached. No water was mixed with the HRC. The temporary wells / injection points were abandoned immediately following injection activities; the top of each boring was filled with bentonite pellets/chips to seal the injection point. Copies of the well construction/ abandonment records are attached. On May 20, 2015 we injected media into deep well DW-1 using a tremie pipe. Approximately 180 gallons of water mixed with 20 gallons of 3-D MicroEmulsion (3-DME) was injected/ gravity fed into well DW-1. Please contact the undersigned if you have any questions and / or if you need any additional information. Sincerely, /' ;,,, ( 1 .. 11 -?✓ /l . I / '--.. .-J~,1-£.,1 L~'x. ·· ./ t!·~L,L-"' .. _,L_ ff(i~) ·-·· Jeffrey L. Gerlock, L.G. NC Licensed Geologist # 1141 Attachments-Figure, summary table of injection points, construction/ abandonment records cc: Mr. Jim Heery, Fiber Dynamics Ms. Sharon Cihak, GCDPH 306 Eden Terrace, Suite C, Archdale, NC 27263 * Phone/Fax: 336-431-5454 ,Gate Sludge Rollofl Area (tinder canopy) 0.7 N Asphalt Parking Lot I W 3-: w s.4 Q I Itvs-Q 0 •MW-5 V s.3 NE Corner of Building - Basement MW-6 eend: • Groundwater Monitoring Well D.7 Tetrachloroethene (PCE) in Groundwater (micrograms per liter) in 2014 Groundwater Flow Direction IW3-4 0 Temporary Injection Well / Point - May 2015 REF.: Surge} 6} Triad Land Surveying Dated Jul) 2009 amended Nov 2012, N N ND- Iwo-1 .MW-4 `01W4-2 DW- 1 IW6-3 iW6-4 IW6-2 i 0.7 Gravel Parking Lot N 1W3-] \ IW3-. 0. DW-2 \' N N. nv3.20 • MV} -3 I143-4 D I 1W7_ \ IW3-3 / WP 0 MW-7 r MW-2 0 [W7.2 / ND cs-ev Icog e .4° / b` / N I 11 MW-9 • MW-10 • c—I Residence 1 Ennis Street Scale: 1 inch = 50 feet Site Plan Fiber Dynamics 200 South West Point Avenue High Point,North Carolina June 2015 Figure 1 a Table 1 Fiber Dynamics, High Point -Injection Information TD/ Bottom Top of Vertical HRC Mixing Injection of Boring/ Well Injection Injection zone Injected Water Area Well ID# Date (feet bgs) (feet bgs) (feet) (lbs) (gallons) Well MW-3 IW3-1 5/18/2015 21 2 19 90 0 IW3-2 5/18/2015 21 2 19 90 0 IW3-3 5/18/2015 21 2 19 90 0 IW3-4 5/18/2015 21 2 19 90 0 IW3-5 5/18/2015 21 2 19 90 0 Well MW-4 IW4-1 5/18/2015 18 2 16 75 0 IW4-2 5/18/2015 17 2 15 75 0 Well MW-5 IW5-1 5/19/2015 10 2 8 60 0 IW5-2 5/19/2015 11 2 9 90 0 IW5-3 5/19/2015 9 2 7 60 0 IW5-4 5/19/2015 9.5 2 7.5 30 0 IW5-5 5/19/2015 9 2 7 60 0 Well MW-6 IW6-1 5/19/2015 13 2 11 75 0 IW6-2 5/19/2015 13 2 11 75 0 IW6-3 5/19/2015 14 2 12 75 0 IW6-4 5/19/2015 14 2 12 75 0 Well MW-7 IW7-1 5/19/2015 25 14 11 60 0 IW7-2 5/19/2015 25 14 11 60 0 IW7-3 5/19/2015 25 14 11 60 0 TOTALS 1380 0 3-D ME Mixing (gallons) Water Well (gallons) I DW-1 I I 5/20/2015 I 55 I 50 I 5 20 180 TD -Total Depth BGS -below ground surface WELL ABANDONMENT RECORD This form can be used for single or multiple wells 1. Well Contractor Information: John Allen Well Contractor Name ( or well owner personally abandoning well on his/her property) 4196 NC Well Contractor Certification Number Terra Sonic Intl Company Name 2. Well Construction Permit#: WI0400391 ------------------List all applicable well permits (i.e. County, State, Variance, Injection, etc.) if/cnown 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply) □Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) Dlrri !!ation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge 0Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop) □Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 5-18-2015 4. Date well(s) abandoned: ________ _ Sa. Well location: Fiber Dynamics, Inc. Facility/Ovmer Name Facility JD# (if applicable) 200 South West Point Ave, High Point 27261 Physical Address, City, and Zip Guilford 0172345 County Parcel Identification No. (PIN) Sb. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) 35.9465 ------------N -80.0159 CONSTRUCTION DETAILS OF WELUS} BEING ABANDONED w Allach well constn,ction record(s) if available For multiple injection or non-water supp(v wells ONLY with the same co11s/ruc/ionlaba11do11menl, you can submit one form. 6a. Well ID#: IW3-1 to 3-5 6b. Total well depth: _2_1 ______ (ft.) 6c. Borehole diameter: _2_.5 ______ {.in.) 6d. Water level below ground surface: _3 ________ (ft.) 6e. Outer casing length (if known): _________ (ft.) 6f. Inner casing/tubing length (if known): _______ {ft.) 6g. Screen length (if known): ___________ {ft.) I For Internal Use ONLY: WELL ABANDONMENT DETAILS 7a. Number of wells being abandoned: _5 _______ _ For multiple injection or non-waler supply wells ONLY with the same construction/abandonment, you can submit one form. 7b. Approximate volume of water remaining in well(s): O (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: _______________ _ 7d. Amount of disinfectant used: ______________ _ 7e. Sealing materials used (check all that apply): D Neat Cement Grout D Sand Cement Grout D Concrete Grout D Specialty Grout D Bentonite Slurry 0 Bentonite Chips or Pellets D Dry Clay D Drill Cuttings D Gravel D Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: half bag 7g. Provide a brief description of the abandonment procedure: Drilled borehole to refusal/rock using Geoprobe Injected HRC through drill rods from bot of borehole to about 2 feet bgs. Removed rods and poured and packed bentonite from O to 2 ft Digitally signed by Mike Tynan 8. Ce rAlillTk" T DN: cn=Mike Tynan, o, ou, IV I e y n a n email;;;;::mat@terrasonicinternational.com, c=US Date: 2015.06.02 20:17:57 -04'00' Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS IOa. For AH Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of\Vater Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. Forni GW-30 North Carolina Department of Environment and Natural Resources -Division of Water Resources Revised August 2013 WELL ABANDONMENT RECORD This form can be used for single or multiple wells 1. Well Contractor Information: John Allen WeU Contractor Name ( or well owner personally abaiid~nmg well on his/her property) 4196 NC Well Contractor Certification Number Terra Sonic Intl Company Name 2. Well Construction Permit#: WI04 00 391 -----------------List all applicable well permits (i.e. County, State, Variance, Injection, etc.) if/mown 3. Well use (check well use): Water Supply Well: □Agricultural □MunicipaVPublic □Geothennal (Heating/Cooling Supply) □Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irri g ation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge 0Groundwater Remediation □Aquifer Storage and Recovery □ Salinity Barrier □Aquifer Test OStonnwater Drainage □Experimental Technology □Subsidence Control □Geothennal (Closed Loop) □Tracer □Geothennal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5-18 -2015 Sa. Well location: Fiber Dynamics, Inc. Facility/Owner Name Facility ID# (if applicable) 200 South West Point Ave, High Point 27261 Physical Address, City, and Zip Guilford 0172345 County Parcel Identification No. (PIN) Sb. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field , one lat/long is sufficient) 35.9465 N -80.0161 ----------- CONSTRUCTION DETAILS OF WELL<S} BEING ABANDONED w Atrach well construction record{s) if available. For multiple injection or non-waler supply wells ONLY with the some construction/abandomnem , you can submit one form . 6 a. Well ID#: IW4-1 to 4-2 6b. Total well depth: 17 to 18 (ft.) 6c. Borehole diameter: _2_. 5 _____ (in .) 6d. Water level below ground surface: _3 _______ (ft.) 6e. Outer casing length (if known): _________ (ft.) 6f. Inner casing/tubing length (if known): ______ (ft.) 6g. Screen length (if known): ___________ (ft.) I For Internal Use ONLY: WELLABANDONMENTDETAU.S 7a. Number of wells being abandoned: _2 _______ _ For multiple injection or non-waler . supply . wells · ONLY with the ·same constn,ctionlahandonment , you can submit one form. 7b. Approximate volume of water remaining in well(s): 0 (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: _______________ _ 7d. Amount of disinfectant used: ______________ _ 7e. Sealing materials used (check all that apply): D Neat Cement Grout □ Sand Cement Grout D Concrete Grout D Specialty Grout D Bentonite Slurry lt'.l Bentonite Chips or Pellets D Dry Clay □ Drill Cuttings □ Gravel □ Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: half bag 7g. Provide a brief description of the abandonment procedure: Drilled borehole to refusal/rock using Geoprobe Injected HRC through drill rods from bot of borehole to about 2 feet bgs. Removed rods and poured and packed bentonite from O to 2 ft 8. Ce · DN: cn=Mike Tynan, o, ou, . R T Digitally signed by Mike Tynan Ml e y n a n., ~m•il=mat@terrasonicinter~tl~nal.com, c=US Date: 2015 ,06,02 20:19:05 -0400 Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner, 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details_ You may al so attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following : Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 IOb. For In jection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of\Vater Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & [njection Wells: In addition to sending the form to the address(es) above , also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. Form GW-30 North Carolin a Department of Enviro nment and Natural Reso urces -Division of Water Resources Revised Au gust 2013 WELL ABANDONMENT RECORD This form can be used for single or multiple wells 1. Well Contractor Information: John Allen Well Contractor Name (or well owner personally abandoning well on his/her property) 4196 NC Well Contractor Certification Number Terra Sonic Intl Company Name 2. Well Construction Permit#: WI0400391 ------------------ List all applicable well permits (i.e. County, State, Variance, Injection, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply) □Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) Dlrri!rntion Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge 0Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop) □Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 5-19-2015 4. Date well(s) abandoned: _________ _ Sa. Well location: Fiber Dynamics, Inc. Facility/Owner Name Facility ID# (if applicable) 200 South West Point Ave, High Point 27261 Physical Address, City, and Zip Guilford 0172345 County Parcel Identification No. (PIN) Sb. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N -80.0163 ------------35.9465 CONSTRUCTION DETAILS OF WELL{S) BEING ABANDONED w Attach well construction recordM if available. For multiple injection or non-waler supply we/is ONLY with the same co11stn1ctia1v'obando11ment, you can submit one }Orm. 6a. Well ID#: IW5-1 to 5-5 6b. Total well depth: 9 to 11 (ft.) 6c. Borehole diameter:_2_-5 ______ (in.) 6d. Water level below ground surface: _3 ________ (ft.) 6e. Outer casing length (if known): _________ (ft.) 6f. Inner casing/tubing length (if known): _______ (ft.) 6g. Screen length (if known): ___________ (ft.) I For Internal Use ONLY: WELL ABANDONMENT DETAILS 7a. Number of wells being abandoned: _5 _______ _ For multiple injection or non-water suppZv wells ONLY with tlfe same construclionlabandonment. you can submit onefom,. 7b. Approximate volume of water remaining in well(s): 0 (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: ________________ _ 7d. Amount of disinfectant used: ______________ _ 7e. Sealing materials used (check all that apply): D Neat Cement Grout □ Sand Cement Grout D Concrete Grout D Specialty Grout D Bentonite Slurry Ill Bentonite Chips or Pellets D Dry Clay D Drill Cuttings □ Gravel D Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: half bag 7g. Provide a brief description of the abandonment procedure: Drilled borehole to refusal/rock using Geoprobe Injected HRC through drill rods from bot of borehole to about 2 feet bgs. Removed rods and poured and packed bentonite from Oto 2 ft . er IC • DN: cn=Mike Tynan, o, OU, 8 C Nlltk T DigitallysignedbyMikeTynan e y n a n email=mat@terrasonicinternational.com, c=US Date: 2015.06.02 20:20:42 -04'00' Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby cerfifj, that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided lo the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. S llBMITIAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For In jec tion Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of\Vater Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. Form GW-30 North Carolina Department of Environment and Natural Resources -Division of Water Resources Revised August 2013 WELL ABANDONMENT RECORD This fomt can be used for single or multiple wells 1. Well Contractor Information: John Allen Well Contractor Name (9r well owner personally. ~b~doning well on liis/her property). 4196 NC Well Contractor Certification Number Terra Sonic Intl Company Name 2. Well Construction Permit #:_W_I_0_4_0_0_3_9_1 ________ _ List all applicable well permits (i.e. County, State, Variance, lnjeClion, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply) □Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply(shared) □Irri e ation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge 0Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop) □Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 5-19-2015 4. Date well(s) abandoned: ________ _ Sa. Well location: Fiber Dynamics, Inc. Facility/Owner Name Facility ID# (if applicable) 200 South West Point Ave, High Point 27261 Physical Address, City, and Zip Guilford 0172345 County Parcel Identification No. (PIN) Sb. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) 35.9464 N -80.0162 ----------- CONSTRUCTION DETAILS OF WELL{S} BEING ABANDONED w Aflac/, well conslruclion record{s) if available. For multiple injection or non-water supply wells ONLY with the same construcho11/obando11me11t, you can submil one form. 6a. Well ID#: IW6-1 to 6-4 6b. Total well depth: 13 to 14 (ft.) 6c. Borehole diameter: _2_.5 _____ (in.) 6d. Water level below ground surface: _3 _______ (ft) 6e. Outer casing length (if known): _________ (,ft.) 6f. Inner casing/tubing length (if known): _______ (ft.) 6g. Screen length (if known): ___________ (ft.) I For Internal Use ONLY: WE LL ABANDONME NT DETAIL. 7a. Number of wells being abandoned: _4 ______ _ For ' multiple ·· injeClion or .non-water supply wells ONLY with the same construction/abandonment, you can submit one foi-in :· 7b. Approximate volume of water remaining in well(s): 0 (gal.) FORWATERSUPPLYWELLSONLY: 7c. Type of disinfectant used: _______________ _ 7d. Amount of disinfectant used: _____________ _ 7e. Sealing materials used (check all that apply): □ Neat Cement Grout □ Sand Cement Grout □ Concrete Grout □ Specialty Grout □ Bentonite Slurry 0 Bentonite Chips or Pellets D Dry Clay □ Drill Cuttings □ Gravel □ Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: half bag 7g. Provide a brief description of the abandonment procedure: Drilled borehole to refusal/rock using Geoprobe Injected HRC through drill rods from bot of borehole to about 2 feet bgs. Removed rods and poured and packed bentonite from O to 2 ft Digitally signed by Mike Tynan 8. Ciffifl1ilr, T ON: cn~Mike Tynan, o, ou, IV I I\. e Y n a n ;:tmat@terrasoniante,nationat.com, · Date: 2015.06.02 20:21 :10 -04'00' Signature of Certified .Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary . SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit.this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 !\fail Service Center, Raleigh, NC 27699-1617 lOb. For Injection Wells: In addition to sending the form to the address in JOa above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supplv & Injectjon Wells: In addition to sending the form to the address(es) above , also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. Form GW-30 North Carolina Department of Environment and Natural Resources-Division of Water Resources Revised August 2013 WELL ABANDONMENT RECORD This form can be used for single or multiple wells I. Well Contractor Information: John Allen Well Contractor Name (or well owner personally abandoning well on bis/her property) 4196 NC Well Contractor Certification Number Terra Sonic Intl Company Name 2. Well Construction Permit#: WI0400391 ------------------Lis I all applicahle well perm ifs (i.e. County, State, Variance, Injection, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply) □Residential Water Supply (single) □ Industrial/Commercial □Residential Water Supply (shared) □ Irri uation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge ~Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop) □Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5-19-2015 Sa. Well location: Fiber Dynamics, Inc. Facility/Owner Name Facility ID# (if applicable) 200 South West Point Ave, High Point 27261 Physical Address, City, and Zip Guilford 0172345 County Parcel Identification No. (PIN) Sb. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) 35.9464 N -80.0158 ------------ CONSTRUCTION DETAILS OF WELL{S} BEING ABANDONED w Aflac/, v.•e/1 construction record(s) if available. For multiple 11yec1ion or non-wafer supp(v wells ONLY with the same construction/abandonment, you can suhmil one form. 6a. Well ID#: IW7-1 to 7-3 6b. Total well depth: _2_5 ______ (ft.) 6c. Borehole diameter: _2_.5 ______ (in.) 6d. Water level below ground surface: _1_4 _______ (ft.) 6e. Outer casing length (if known}: _________ (ft.) 6f. Inner casing/tubing length (if known): ______ (ft.} 6g. Screen length (if known): ___________ (ft.) I For Internal Use ONLY: WELL ABANDONMENT DETAILS 7a. Number of wells being abandoned: _3 ______ ~_ For multiple injection or non-water supp~v wells ONLY with the same consLnictiow'ahandonmenl, you can submit one form. 7b. Approximate volume of water remaining in well(s): 0 (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: ________________ _ 7d. Amount of disinfectant used: ______________ _ 7e. Sealing materials used (check all that apply): □ Neat Cement Grout ~ Bentonite Chips or Pellets □ Sand Cement Grout □ Dry Clay □ Concrete Grout □ Drill Cuttings □ Specialty Grout □ Gravel □ Bentonite Slurry □ Other ( explain under 7 g) 7f. For each material selected above, provide amount of materials used: one bag 7g. Provide a brief description of the abandonment procedure: Drilled borehole to refusal/rock using Geoprobe Injected HRC through drill rods from bot of borehole to about 14 feet bgs. Removed rods and poured and packed bentonite from Oto 14 ft • e DN: cn=Mike Tynan, o, ou, 8 t{·• . Digitally signed by Mike Tynan M1 ~ Ty n a n email=mat@terrasonicinternational.com, c=US Date: 2015.06.02 20:21 :37 -04'00' Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the welf(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wrlls: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. FormGW-30 North Carolina Department of Environment and Natural Resources -Division of Water Resources Revised August 20 I 3 Permit Number Program Category Deemed Ground Water Permit Type WI0400391 Injection Deemed In-situ Groundwater Remediation Well Primary Reviewer michael.rogers Coastal SWRule Permitted Flow Facility Facility Name Fiber Dynamics ( Location Address 200 S W Point Ave High Point Owner Owner Name Fiber Dynamics Inc Dates/Events NC Orig Issue 4/14/2015 App Received 3/27/2015 Regulated Activities Groundwater remediation Outfall Waterbody Name 27263 Draft Initiated Scheduled Issuance Public Notice Central Files: APS SWP 4/14/2015 Permit Tracking Slip Status Active Version 1.00 Project Type New Project Permit Classification Individual Permit Contact Affiliation Major/Minor Minor Region Winston-Salem County Guilford Facility Contact Affiliation Owner Type Non-Government Owner Affiliation Jeffrey L. Gerlock GL 306 Eden Ter Archdale Issue 4/14/2015 Effective 4/14/2015 NC 27263 Expiration Requested /Received Events Additional information requested Additional information received Streamlndex Number Current Class 4/1/15 4/13/15 Subbasin Ro gers, Michael From: Rogers, Michael Sent: Tuesday, April 14, 2015 2:07 PM To: Cc: 'Jeff Gerlock'; 'jamesaheery@gmail.com' Basinger, Corey; Knight, Sherri Subject: WI0400391 NOi -RE: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC Thank you for submitting the Notice of Intent to Construct or Operate Injection Wells (NOi} at the Fiber Dynamics Facility. This facility is located at 200 South West Point Ave., High Point, Guilford County, NC 27261. We received your complete NOi on April 13, 2015. Please remember to submit the following regarding this injection activity: 1} Well Construction R~cords (GW-1) and Abandonment Records (GW-30) when completed. Please provide copies of the GW-ls and GW-30s if not already submitted (originals go the address printed on the form). NOTE: Direct push or Geoprobe wells are considered wells and require construction (GW-1} and abandonment forms (GW-30). If well construction/abandonment information is the same for the wells, only one form needs to be completed-just indicate total number of injection points in the Comments/Remarks section of form. These forms can be found on our website at http://portal.ncdenr.org/web/wq/aps/gwpro/reporting-forms. 2) Injection Event Records (IER). All injections, including air and passive systems require an IER. The IER can be modified for air sparge wells (e.g., air flow 'continuous' for date or rate of injection, etc.). You can scan and send these forms directly to me at michael.ro gers @ncdenr.gov. send by fax to my attention at 919- 807-6406, or via regular mail to address below. When submitting the above forms, you will need to enter the nine-digit alpha-numeric number on the form (i.e., WI0XXXXXX) that has been assigned to the injection activity at this site. This notification has been given the deemed permit number WI0400391. This number is also referenced in the subject line of this email. You may if you wish, scan and send back as attachments in re p ly to this email, as it will already have the assigned deemed permit number in the subject line. Thank you for your cooperation. Michael Rogers, P.G. (NC & FL} Hydrogeologist NCDENR-DWR Water Quality Regional Operations Section 1636 Mail Service Center Raleigh, NC 27699 Direct No. 919-807-6406 http:ljportal.ncdenr.org/web/wq/aps/gwpro/reporting-forms NOTE: Per Executive Order No. 150, all e-mails sent to and from this account are subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Jeff Gerlock [mailto:jeff.gerlock@gmail.com] Sent: Monday, April 13, 2015 1:16 PM To: Rogers, Michael · Cc: Slusser, Thomas Subject: Re: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC 1 here is a summary table to help show you the information. let me know if you need anything else. On Mon, Apr 13, 2015 at 11:49 AM, Jeff Gerlock <jeff.gerlock@gmail.com> wrote: Good morning Mike; hope you had a nice weekend. just wanted to check in with you on your email request for info on the proposed injection at Fiber Dynamics in High Point. the information requested in your email on April 1st is included in our application (page 3). Geoprobe borings will be drilled to auger refusal / top of rock expected at 11 to 21 feet ·and then HRC will be injected through the rods from the bottom of each boring to the water surface. intervals are shown in the application. we will use the recommended 6 lbs per foot of HRC at each borehole. there is no water added to the HRC. a schematic of the geoprobe locations / areas and depths is shown on the cross section attached to the application. we may also inject 3-D ME into the bottom 10 foot of well DW-1 at a rate of2.4 gallons per foot or 24 gal / 200 lbs total of material at a 10 % dilution rate therefore we will mix the 3D ME with 240 gallons of water. MSDS forms for the two chemicals are attached. let me know if you need me to prepare a table, figure, or provide other information for the proposed work at the site. On Wed, Apr 1, 2015 at 3:15 PM, Rogers, Michael <michael.rogers@ncdenr.2:ov> wrote: Would you please provide a total estimated average on the total amount of injectant plus chase water you are going to inject at each proposed Geoprobe (in gallons), and at DW-1. Additionally, would you proved a schematic of proposed Geoprobe with total depth. We realize this is proposed and actual depth will vary a little at each point. Thanks From: Jeff Gerlock [mailto:jeff.gerlock@gmail.com] Sent: Monday, March 30, 2015 12:56 PM To: Rogers, Michael Cc: Slusser, Thomas Subject: Re: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC I understand -we were not planning to do the work for about a month or so. just wanted to make sure you have all the paperwork and answers you need to process. On Mon, Mar 30, 2015 at 12:54 PM, Rogers, Michael <michael.ro 2.ers c ,ncdenr.iw v> wrote: NO, not yet. We need to review and process, enter project into our system, and forward a copy to the regional office for their review. That's why we require a 2-week notice before injection activities. 2 Ro gers , Michael From: Rogers, Michael Sent: To: Tuesday, April 14, 2015 2:05 PM Basinger, Corey; Knight, Sherri Subject: Attachments: FW: WI0400391 NOi -Fiber Dynamics 20150414133417149.pdf Please find attached a NOi for the above project. -----Original Message----- From: Michael Rogers [mailto:michael.rogers @ncdenr.gov) Sent: Tuesday, April 14, 2015 1:34 PM To: Rogers, Michael Subject: This E-mail was sent from "RNPAC7DD0" (Aficio 2075). Scan Date: 04.14.2015 13:34:17 (-0400) Queries to: robin.markham@ncdenr .go v 1 Ro gers, Michael From: Sent: To: Cc: Subject: Attachments: Jeff Gerlock <jeff.gerlock@gmail.com> Monday, April 13, 2015 1: 16 PM Rogers, Michael Slusser, Thomas Re: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC Fiber-Injection lnfo.pdf here is a summary table to help show you the information. letme know if you need anything else. On Mon, Apr 13, 2015 at 11 :49 AM, Jeff Gerlock <jeff.gerlock@ gmail.com> wrote: Good morning Mike; hope you had a nice weekend. just wanted to check in with you on your email request for info on the proposed injection at Fiber Dynamics in High Point. the information requested in your email on April 1st is included in our application (page 3). Geoprobe borings will be drilled to auger refusal/ top of rock expected at 11 to 21 feet and thenHRC will be injected through the rods from the bottom of each boring to the water surface. intervals are shown in the application. we will use the recommended 6 lbs per foot of HRC at each borehole. there is no water added to the HRC. a schematic of the geoprobe locations / areas and depths is shown on the cross section attached to the application. we may also inject 3-D ME into the bottom 10 foot of well DW-1 at a rate of2.4 gallons per foot or 24 gal/ 200 lbs total of material at a 10 % dilution rate therefore we will mix the 3D ME with 240 gallons of water. MSDS forms for the two chemicals are attached. let me know if you need me to prepare a table, figure, or provide other information for the proposed work at the site. On Wed, Apr 1, 2015 at 3:15 PM, Rogers, Michael <michael.ro e:ers(@ncdenr.rzo v> wrote: Would you please provide a total estimated average on the total amount of injectant plus chase water you are going to inject at each proposed Geoprobe (in gallons), and at DW-1. Additionally, would you proved a schematic of proposed Geoprobe with total depth. We realize this is proposed and actual depth will vary a little at each point. Thanks From: Jeff Gerlock [mailto:jeff.gerlock@gmail.com] Sent: Monday, March 30, 2015 12:56 PM To: Rogers, Michael Cc: Slusser, Thomas Subject: Re: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC 1 I understand -we were not planning to do the work for about a month or so. just wanted to make sure you have all the paperwork and answers you need to process. On Mon, Mar 30, 2015 at 12:54 PM, Rogers, Michael <michael.ro gers @ncdenr.gov> wrote: NO, not yet. We need to review and process, enter project into our system, and forward a copy to the regional office for their review. That's why we require a 2-week notice before injection activities. From: Jeff Gerlock [mailto:jeff.gerlock@gmail.com] Sent: Monday, March 30, 2015 10:14 AM To: Slusser, Thomas; Rogers, Mike; Rogers, Michaer Subject: Re: Request for Approval of Small~Scale Injection Operation -Fiber Dynamics, High Point, NC sounds good. so is everything complete and all look fine to order the materials and proceed with our pilot test? On Mon, Mar 30, 2015 at 10:08 AM, Slusser, Thomas <thomas.slusser@.ncdenr.gov> wrote: Greetings Jeff, Thanks for the submittal. Mike Rogers, copied on this email, will be your project contact for this one. Take care, -Thomas Slusser, L.G. Underground Injection Control Program Manager thomas.slusser@ncdenr.gov I ph# 919-807-6412 I fax# 919-807-6496 Mailing Address: NCDENR Division of Water Resources I 1636 Mail Se:i;vice Center I Raleigh, NC 27699-1636. Physical Address: Room 640M, Archdale Building, 512 N. Salisbury St., Raleigh, NC 27604. Internet Address: http://portal.ncdenr.org/web/wq/aps/gwpro . 2 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties udess Me content is exempt by statute or other regulation. From: Jeff Gerlock [mailto:jeff.gerlock@gmail.com] Sent: Friday, March 27, 2015 5:42 PM To: Slusser, Thomas Subject: Re: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC Good afternoon Thomas. hope you are having a good Friday. attached is our revised NOi for injection at the site. please review and call if you have any questions and/or if you need any clarification or other information. thanks. Note -please respond to let me know that you received this email and the attachments. On Thu, Mar 12, 2015 at 1:56 PM, Slusser, Thomas <thomas.slusser@p cdenr.1:mv> wrote: Thanks Jeff for the update. Let me know if you have any questions for me as you move forward with this. Take care, -Thomas Slusser, L.G. Underground Injection Control Program Manager thomas.slusser@ncdenr.gov I ph# 919-807-6412 I fax# 919-807-6496 Mailing Address: NCDENR Division of Water Resources I 1636 Mail Service Center I Raleigh, NC 27699-1636. Physical Address: Room 640M, Archdale Building, 512 N. Salisbury St., Raleigh, NC 27604. Internet Address: http://portal.ncdenr.org/web/wq/aps/gwpro E-mal1 correspondence to and from this address may be subject to the North Carolina Public Records Law and may be discloser/ to third parties unless the content is exempt by statute or other regulation. 3 From: Jeff Gerlock [mailto:jeff .gerlock@gmail.com] Sent: Thursday, March 12, 2015 11:16 AM To: Slusser, Thomas Subject: Re: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC sorry I forgot to get back with you on this matter. I have recently revised our remediation plan and injection strategy after further discussions with my supplier. I will make the change you suggested and our changes and resubmit the plan this week. thanks for your follow up! On Tue, Mar 3, 2015 at 12:52 PM, Slusser, Thomas <thomas.slusser(a),ncdenr.2ov> wrote: Greetings Jeff, I have not yet received the revised NOI for this project. Have you submitted it yet? Thanks, -Thomas Slusser, L.G. Underground Injection Control Program Manager thomas.slusser®ncdenr.gov I ph# 919-807-6412 I fax# 919-807-6496 Mailing Address: NCDENR Division of Water Resources I 1636 Mail Service Center I Raleigh, NC 27699-1636. Physical Address: Room 640M, Archdale Building, 512 N. Salisbury St., Raleigh, NC 27604. Internet Address: http://portal.ncdenr.org/web/wq/aps/gwpro E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation From: Slusser, Thomas Sent: Tuesday, February 17, 20151:40 PM To: Jeff Gerlock Subject: RE: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC 4 Greetings Jeff, I looked at the submittal and everything looks good, but I did not see a table or diagram of well construction information as asked for in Part K(2). Otherwise, everything is fine. Thank you, ~ Thomas Slusser, LG. Underground Injection Control Program Manager NC Division of Water Resources ph# 919-807-6412 http://portal.ncdenr.org/web/wg/aps/gwpro 1636 Mail Service Center Raleigh, NC 27699-1636 E-mail correspondence to and from this address may be subject to the North carolina Public Records Law and may be disclosed to third parties. From: Jeff Gerlock [jeff.gerlock@gmail.com] Sent: Monday, February 16, 2015 5:10 PM To: Slusser, Thomas Subject: Request for Approval of Small-Scale Injection Operation -Fiber Dynamics, High Point, NC Thomas, per our conversation this morning attached is our application/ NOi for the project. please review and let me know if we need to modify or include additional information. thanks for your help. Note -please respond to let me know that you received it. Jeff Gerlock Blue Ridge Geological Services 306 Eden Terrace, Suite C Archdale, NC 27263 336-431-5454 office phone and fax Jeff Gerlock 5 Blue Ridge Geological Services 306 Eden Terrace, Suite C Archdale, North Carolina 27263 336-431-5454 office phone and fax www.blueridge geo.com Jeff Gerlock Blue Ridge Geological Services 306 Eden Terrace, Suite C Archdale, North Carolina 27263 336-431-5454 office phone and fax www.blueridge geo.com Jeff Gerlock Blue Ridge Geological Services 306 Eden Terrace, Suite C Archdale, North Carolina 27263 336-431-5454 office phone and fax www.blueridge geo.com 6 NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES NOTIFICATION OF INTENT TO CONSTRUCT OR OPERATE INJECTION WELLS The following are "permitted by rule" and do not require an individual permit when constructed in accordance with the rules of ISA NCAC 02C .0200. This form shall be submitted at least 2 weeks prior to iniection. AQUIFER TEST WELLS (1 5A NCAC 02c .0220) These wells are used to inject uncontaminated fluid into an aquifer to determine aquifer hydraulic characteristics. IN SITU REMEDIATION (1 5A NCAC 02C .0225) or TRACER WELLS <ISA NCAC 02C .0229): 1) Passive Injection S y stems -In-well delivery systems to diffuse injectants into the subsurface. Examples include ORC socks, iSOC systems, and other gas infusion methods. 2) Small-Scale In jection Operations -Injection wells located within a land surface area not to exceed 10,000 square feet for the purpose of soil or groundwater remediation or tracer tests. An individual permit shall be required for test or treatment areas exceeding 10,000 square feet. 3) Pilot Tests -Preliminary studies conducted for the purpose of evaluating the technical feasibility of a remediation strategy in order to develop a full scale remediation plan for future implementation, and where the surface area of the injection zone wells are located within an area that does not exceed five percent of the land surface above the known extent of groundwater contamination. An individual permit shall be required to conduct more than one pilot test on any separate groundwater contaminant plume. 4) Air Injection Wells -Used to inject ambient air to enhance in-situ treatment of soil or groundwater. Print Clearly or Type Information. Rlegible Submittals Will Be Returned As Incomplete. DATE: March 25 , 2015_ PERMIT NO. 1 _j r O y oo ) q / (to be filled in by DWR) ~ ~ A. WELL TYPE TO BE CONSTRUCTED OR OPERATED (1) ___ Air Injection Well. ..................................... Complete sections B-F, K, N (2) --~Aquifer Test Well ....................................... Complete sections B-F, K, N (3) --~Passive Injection System ............................... Complete sections B-F, H-N (4) X __ Small-Scale Injection Operation ...................... Complete sections B-N (5) ___ Pilot Test ................................................. Complete sections B-N (6) ___ Tracer Injection Well ................................... Complete sections B-N B. STATUS OF WELL OWNER: Business/Organization C. WELL OWNER -State name of entity and name of person delegated authority to sign on behalf of the business or agency: Name: ---=F~ib~e=r=D__.y:rumu=· ==·c=s~. =In=c~. -~C~Je=ff~G~e=rl=o=ck~of~B==lu=e~Ri=·=d=ge~a=u=th~to~si.._.gn~o=n~b=eh=a=l~fo=f~F~i=b=er~) __ _ Mailing Address: 200 South WestPoint Avenue City: High Point State: _NC_ Zip Code: 27261 County: Guilford Day Tele No.: 336-886-7111 Cell No.: 336-382-6849 Jeff EMAIL Address: jamesaheery@gmail.com Fax No.: _______ _ VIC/In Situ Remed. Notification (Revised 11/19/2013) Page 1 March 25, 2015 Mr. Thomas Slusser NCDENR Division of Water Resources — UIC Program 1636 Mail Service Center Raleigh, North Carolina 27699-1636 Subject: Revised Notice of Intent for injection Fiber Dynamics, Inc. 200 South West Point Avenue High Point, Guilford County, North Carolina NCDENR Site ID#NON CD 0002854 Dear Mr. Slusser: On behalf of Fiber Dynamics, Inc., Blue Ridge Geological Services, Inc. (Blue Ridge) is planning to perform additional environmental activities at the subject site in 2015. Attached are a Notice of Intent (NOD application form and the required attachments for performing injection activities at the site. Per our discussion we plan to drill boreholes and inject material through hollow drill rods of a Geoprobe and then abandon the boreholes. We do not plan to install any injection wells at this time, We may also inject media into existing well DW-1. Please contact the undersigned if you have any questions and / or if you need any additional information. We appreciate your review of this information. Sincerely, Jeffrey L. Gerlock, L.G. NC Licensed Geologist #1141 Registered Environmental Consultant #149 Attachments —NOI Form, Figures, DW-1 construction record cc: Mr. Jim Heery, Fiber Dynamics 306 Eden Terrace, Suite C, Archdale, NC 27263 * Phone/Fax: 336-431-5454 D. PROPERTY OWNER (if different than well owner) Name: ---~s=am~e =a~s =ab=o~v~e _______________________ _ Mailing Address:-------------------------------- City: ____________ State: __ Zip Code: _______ County: _____ _ Day Tele No.: ___________ _ Cell No.: __________ _ EMAIL Address: _____________ _ Fax No.: __________ _ E. PROJECT CONTACT -P_erson who can answer technical questions about the proposed injection project. Name: ___ .,c.Je=f=f -=G=e=rl=o=ck=,..:B=l=u=-e =Ri=·d=-g:,.;::e:....;G=eo=lo=e=i=ca=l-=S=e-=--rv'-"i=ce=s"--, =In=c"-. ______________ _ Mailing Address: 306 Eden Terrace Suite C City: Archdale State: _NC_ Zip Code:~2=7=2=6~3 ___ County: Randolph Day Tele No.: 336-431-5454 Cell No.: __ ~3~3~6~-3~8=2-~6~84~9~--- EMAIL Address:jeff.gerlock@gmail.com Fax No.: ---=-3~36~-4~3~1~-5~4=5~4 ___ _ F. PHYSICAL LOCATION OF WELL SITE (1) (2) Physical Address: ---"2=0=0'-"S=o=u=th=-..W"-'e=s:.:..t -=-P=om=· :=..t _,,_,Ac_,_v,=en=u=e,_____ ______________ _ _______________________ County: ___ G~m=lfi=o=rd~-- City: High Point State: NC Zip Code: ~2~72=6~1 _____ _ Geographic Coordinates: Latitude**: N __ ~3~5° 56_' 47_" or Longitude**: W __ ~8~0° __QQ' 47 _,, or 0 0 Reference Datum: MW-4 p lume ctr Accuracy: _______ _ Method of Collection: Google Earth and GPS **FOR AIR INJECTION AND AQUIFER TEST WELLS ONLY: A FACILITY SITE MAP WITH PROPERTY BOUNDARIES MAY BE SUBMITTED IN LIEU OF GEOGRAPHIC COORDINATES. G. TREATMENT AREA Land surface area of contaminant plume:~1=3.=6~00~ ___ square feet Land surface area ofinj . well network: 3 000 square feet (:5 10,000 ft2 for small-scale injections) Percent of contaminant plume area to be treated: 25 (must be::; 5% of plume for pilot test injections) H. INJECTION ZONE MAPS -Attach the following to the notification. (1) Contaminant plume map(s) with isoconcentration lines that show the horizontal extent of the contaminant plume in soil and groundwater, existing and proposed monitoring wells, and existing and proposed injection wells; and (2) Cross-section(s) to the known or projected depth of contamination that show the horizontal and vertical extent of the contaminant plume in soil and groundwater, changes in lithology, existing and proposed monitoring wells, and existing and proposed injection wells. UIC/ln Situ Remed. Notification (Revised 11/19/2013) Page2 DESCRIPTION OF PROPOSED INJECTION ACTIVITIES — Provide a brief narrative regarding the purpose, scope, and goals of the proposed injection activity. We plan to drill sail borings to the top of rock (expected at 11 to 21 feet bgs) near wells MW-3, MW-5. MW- 6. and MW-7 and then inject media (HRC) into the groundwater through the hollow rods of the Geoprobe rise (no wells will be installed). As shown on the attached figure. we nlan to inject at approximately 17 locations. The media will be injected from the bottom of boring to the groundwater surface (about 11 to 14 feet vertically in each borehole). Injection intervals at well areas are as follows: MW-3 (4 to 21),_MW-5 (3 to 14), M W-6 t4 to 181, MW-7 (14 to 25). The purpose of the work is to attempt to degrade the contaminants (primarily PCE) in the shallow groundwater to below the 2L action levels to attempt to get site closure. We also plan to inject HRC and/or 3-D Microemulsion (3DME) into well DW-1 to attempt to remediate the PCE in the rock. J. U' JECTANTS — Provide a MSDS and the following for each injectant_ Attach additional sheets if necessary. NOTE: Approved injectants (tracers and remediation additives) can be found online at hur.:, portal.ncdenr.orgfwebrwglaysigwpro. All other substances must be reviewed by the Division of Public Health, Department of Health and Human Services. Contact the UIC Program for more info (919-807-6496). Injectant: 3-D Microemulsion Volume of injectant: 24 gal per pointplus water Concentration at point of injection: DW-1 -122 ug L Percent if in a mixture with other injectants: 1O% dilution rate - injectant linjectant plus water) Injectant: HRC Volume of injectant: 61bs / ft of injection at each borehole/injection point Concentration at point of injection: 7.1 to 61.2 ualL (as shown an figures) Percent if in a mixture with other injectants: lnjectant: Volume of injectant: Concentration at point of injection: Percent if in a mixture with other injectants: K. WELL CONSTRUCTION DATA (1) Number of injection wells: 18 points Proposed U Existing • - (2) Provide well construction details for each injection well in a diagram or table format. A single diagram or line in a table can be used for multiple wells with the sarne construction details. Well construction details shall include the following: (a) (b) (c) well type as permanent, direct -push, or subsurface distribution system (infiltration gallery) depth below land surface of grout, screen, and casing intervals well contractor name and certification number U!C11n Situ Rcrneel, Notification (Revise411111912013) Page 3 L. SCHEDULES — Briefly describe the schedule for well construction and injection activities. Plan to inject over a two dal period startinc in mid to late April 2015 M. MONITORING PLAN — Describe below or in separate attachment a monitoring plan to be used to determine if violations of groundwater quality standards specified in Subchapter 02L result from the injection activity. We plan to collect groundwater from on -site and off -she downgradient wells following the injection aetivin. We will analyze the samples for VOCS by. Method 8260. We will provide a summary report to the NCDENR. N. SIGNATURE OF APPLICANT AND PROPERTY OWNER APPLICANT: "1 hereby certify, under penalty of law, that 1 am familiar with the information submitted in this document and all attachments thereto and that, based on my inquiry of those individuals immediately responsible for obtaining said information, 1 believe that the information is true, accurate and complete. 1 am aware that there are significant penalties, including the passibility of fines and imprisonment, for submitting false information. I agree to construct, operate, maintain, repair, and if applicable, abandon the injection well and all related appurtenances in accordance with the 1.5A NCAC 02C 0200 Rules." Jeffrey L. Gerlock (agent for Fiber[ leant Print or Type Full Name PROPERTY OWNER (if the property is not owned by the permit applicant): "As owner of the property on which the injection well(s) are to be constructed and operated 1 hereby consent to allow the applicant to construct each injection well as outlined in this application and agree that it shall be the responsibility of the applicant to enure that the injection we11(s) conform to the Well Construction Standards (1 SA NCAC 02C .0200). " `Owner" means any person who holds the fee or other property rights in the well being constructed. A well is real property and its construction on land shall be deemed to vest ownership in the land owner, in the absence of contrary agreement in writing, Signature* of Property Owner (if different from applicant) Print or Type Full Name • An access agreement between the applicant and property owner may be submitted in lieu of a signature on this form. Submit one copy of the completed notification package to: DWR — U1C Program 1636 Mail Service Center Raleigh, NC 27699-1636 Telephone: (919) 807-6464 U1C1an Situ Remed. Notification (Revised 1 I/ 9/2013) Page 4 G Gate w- I / *tiff/ Sludge RolloflArea Legend: • ' Monitoring Well 513.9 Tetrachloroethene (PCE) in Groundwater (micrograms per liter) on 1/14/2014 (NS- Not Sampled) N '°'4 Gravel / / ` 4.Parking Lot I ': 1 / f kPr C ea Asphalt / 4I Parking Lot �,v,� I q;° �r NI 47.12 Fulmer sludge Id Rolloff Nib Ccnncr of Budding - Basrnient W-5 06 30. 0.7 p N / MW-1a MW-4 nw-.a,' '' w•1 • S `1 12'-* 1 ~ �42.5 I — N ` \ • oA L • I1 10 1M [, MW-2 <I /ND NS >� I I / co / / • / b / /9 �n� f • Groundwater Flow Direction 0 Proposed Injection Point REF.: Survey by Triad Land Surveying Dared July 2009 amended Nov 2012. MW-7 7,I * F M W-9 • -1 Residence 0 M W-8 NS* 1 Ennis Street Scale: 1 inch = 50 feet 1- -Si c It I-.II�t i Prop used Inj eciion Areas Fiber Dynamics 200 South West Point Avenue Iligh Point,North Carolina March 2U75 Figure 1 00 595 — 190 585 180 575 570 165 160 ¢55 — 150 S45 140 535 130 125 120 515 110 505 100 A (NORTHWEST) MW-1 MW-1 AR MONITOR WELL & SCREEN INTERVAL 651 75.6 PCE ITOTAL VOC (ug!L) CONCENTRATION IN GROUNDWATER ND NOT DETECTED AR AUGER REFUSAL BT BORING TERMINATED r DEPTH TO WATER (FT BGS) IN JAN 2014 FILL/ RESIDUUM ► ► ► ► HIGHLY WEATHERED ROCK ► ND\ FRACTURED ROCK 1 10 PCE ISOCONCENTRATION IN GROUNDWATER PROPOSED INJECTION POINTS (verllcel blue hogs) DW-1 AR HIGHLY WEA7 BT ▪ '. • 1a ND " ED HOCK _- 1421132.5 ti/f� s' ! MW-6 DW-2 1.58 AR MW-2 A' (SOUTHEAST) 90: Property Line ATER TABLE Flu.! RESIDUUM 1 r 19.1 r 1 r 1 AR HIGHLY WEATHERED ROCK Fractures �l UNFRACTURED BEDROCK 20 BT NOTES: 1) MONITORING WELLS SAMPLED IN AUG 2012{MW1, MW6) S JAN 2014(MW2, MW5, MW7, DWI, DW2). 2) SEE SITE PLAN FOR CROSS SECTION LOCATIONS. Q APPROXIMATE SCALE 40 3} ELEVATIONS ARE REFERENCED TO NATIONAL GEODETIC VERTICAL DATUUM (NGVD). 3b1 FEET FRACTURED ROCK ! 1 ! • • 19!24.,9f' ✓ '� r • UNFRACTURRO BEDROCK 1 ■ ...ram MW-7 I 1 1 1 I I ■ 1 ND 89E 89r_ 8s; 86C 85: 85C 84i 84C 835, 83t 82". 82C 81: 81( 80: 80( Cross Sec A - Prop I nj ection Areas Fiber Dynamics 200 South West Point Avenue High Point, North Carolina Mar 2015 Figure 2 Fiber Dynamics, High Point -Proposed Injection Information Approx HRC Mixing DTW DT Rock Injection Interval Vertical interval No borings/ (lbs) Water Area {feet bgs) {feet bgs) (feet bgs) length (ft) injection points Total footage @Glbs/ft (gallons) Well MW-5 3 14 3 to 14 11 5 55 330 0 Well MW-6 3.5 18 3.5 to 18 14.5 4 58 348 0 Well MW-3 3.5 21 3.5 to 21 17.5 5 87.5 525 0 Property line 14 25 14 to 25 11 3 33 198 0 near MW7 TOTALS 17 233.5 1401 0 3-D ME Mixing (gallons) Water Well 2.4 gal/ft (gallons) I DW-1 I I I 45 to 55 I 10 I inject in well I 10 24 240 1 ■ ON ESIDE_ TIAL WELL CONSTRUCTION RECORD North Carolina Department of Environment and Natural Resources - Division of Water Quality WELL CONTRACTOR CERTIFICATION # 2580 4. WELL CONTRACTOR: JASON MANTAK Well Cmtracter (lrrdiuidual) Name GEOLOGIC EXPLORATION, INC. Wei[ Contractor Company Name STREET ADDRESS 176 COMMERCE BLVD STATESVILLE NC 28625 City or Town State Zip Cade ( T04 }. 872-7686 Area code- Phone rxvr6er Z WELL INFORMATION: SITE WELL ID #(lr applicable) DW-1 STATE WELL PERMIT$(irappticabte) DWQ or OTHER PERMIT #(i► applicable) WELL USE (Check Applicable Box) Monitoring ] Municipal/Public 0 lndusleallCmmerciaf p Agricultural 0 Recovery o Injection D Irrigation❑ Other 0 (list use) DATE DRILLED 02fa8110- 02/09/14 TIME COMPLETED AM ❑ PM Q 3 WELL LOCATION: CITY: HIGH POINT 200 S WEST POINT AVENUE 27250 COUNTY GUILFORD (Street Name, Number, Community, Subdivision, Lot No., Panel, 2 p Code) TOPOGRAPHIC LAND SETTING: ❑Slope ❑Valley LJFiat ❑Ridge ❑ Other (check appropnate box) LATITUDE LONGITUDE Latitude/longitude source: oGPS ❑Topographic map (location of well must be shown on a USGS tapo :nap and attached to this form Inca using GAS) 4. FACILITY- to the name e1 the business where we well is located. FACILITY ID #(if applicable) NAME OF FACILITY FIBER DYNAMICS, INC May be in degas, minutes, seconds or in a decimal format STREET ADDRESS 200 S WEST POINT AVENUE HIGH POINT NC 27260 City c r Town State CONTACT PERSON FIBER DYNAMICS, INC Zip Code MAILING ADDRESS 200 S WEST POINT AVENUE HIGH POINT NC 27260 City or Tom State Area code - Phone number 5. WELL DETAILS: a. TOTAL DEPTH: 55.0 FEET Zip Code b. DOES WELL REPLACE EXISTING WELL? YES © NO KI c. WATER LEVEL Below Tap of Casing: 5.0 FT, (Use'+" if Above Top of Casing) d. TOP OF CASING IS 0,0 FT. Above Land Surface' 'Top of casing terminated allot mow land surface may require a valance in accordance with 15A NGAC 2C .0118. a YIELD (gpm): NIA METHOD OF TEST NIA f. DISINFECTION: Type NIA Amount NIA g. WATER ZONES (depth): From To From To From To From To From To From To 6. CASING: Depth or From 0.0 To 50.0 Ft, 4"I'n From 0.0 To 20.0 Ft. B 1M INCH From To Ft. 7. GROUT: Depth Materiel From 9.0 To 41.0 Ft Portland benlcnite Frrxn 0.0 7o 20.0 Ft. Portland begrime/ From To FL Thickness/ PMVaterial .198 ascwwaEu 8. SCREEN: Depth From 50-0 To 55.0 Diameter Ft.2.0 in. From To Ft. in. Fram To Ft. in. 9. SAND/GRAVEL PACK: Depth From 49.0 To 55.0 Ft. 20-40 FINE SILICA SAND Frorn To Ft. From To FL Method SLURRY SLURRY Slot Size Material ,010 in• PVC in. 10. DRILLING LOG From To 0.0 1.0 1.0 10.0 48.0 50.0 10.0 46.0 50.0 55_0 Size Material Formation Description CONCRETE/GRAVEL GRAY/GREEN CLAY TAN WEAThiERED ROCK GRAY FRACTURED ROCK GRAY ROCK 14. REMARKS: BENTONITE SEAL FROI4 41.0 TO 49,0 FT I DP HEREBY 15A NCAC RECORD F+ RTIFY THAT TM$S WELL WAS r' • STRUCTED IN ACCORDANCE WITH EU-CONSTRU •N S. AND THAT ACOPY OF THIS EN tr. OWNER 021o9/1'0 SIGNAT E OF CERTIFIED WELL CONTRACTOR J • ON MP.NTAK DATE PRINTED NAME OF PERSON CONSTRUCTING THE WELL Submit the original to the Division of Water Quality within 30 days. Attn: Information Mgt., 1617 Mail Service Center,- Raleigh, NC 27699-1517 Phone No. (919) 733-7015 ext 568. Form GW-1 b Rev. 7105 3-D Microemulsion (3DMeYrm MATERIALS SAFETY DATA SHEET Last Revised: March 26, 2007 Section 1-- Material Identification Supplier: .:). REGENESIS 1011 Calle Sombra San Clemente, CA 92673 Phone: 949366.8000 Fag: 949366.8090 E-mail: info@regenesis.com • Glycerides, di-, mono [2-[2-[2-(2-hydroxy-1 -oxopropoxy)-1-oxopropoxyl]-1- oxo propoxy] propanoates] Chemical Name(s): • Propanoic acid, 2-[2-[2-(2-hydroxy-l-oxopropoxy)-1-oxopropoxy]-1- oxopropoxy]-1,2,3-propanetriyl ester • Glycerol Chemical Family: Organic Chemical Trade Name: 3-D Microemulsion (3DMe)TM Synonyms: HRC AdvancedTM HRC-PED (Hydrogen Release Compound — Partitioning Electron Donor) Product Use: Used to remediate contaminated groundwater (environmental applications) Section 2 — Chemical Identification CAS# Chemical 823190-10-9 61790-12-3 or 112-80-1 201167-72-8 HRC-PED Fatty Acids (neutralized) Glycerol Tripolylactate 56-81-5 Glycerol Regenesis-3-D Microemulsion MSDS Melting Point: Boiling Point: Flash Point: Density: Solubility: Appearance: Odor: Vapor Pressure: Extinguishing Media: Section 3 -Physical Data Not Available (NA) Not determined (ND) > 200 °F using the Closed Cup method 0.9 -1.1 glee Slightly soluble in acetone. Insoluble in water. Amber semi-solid. Not detectable None Section 4 -Fire and Explosion Hazard Data Use water spray, carbon dioxide, dry chemical powder or appropriate foam to extinguish fires. Water May be used to keep exposed containers cool. For large quantities involved in a fire, one should wear full protective clothing and a NIOSH approved self contained breathing apparatus with full face piece operated in the pressure demand or positive pressure mode as for a situation where lack of oxygen and excess heat are present. Acute Effects: RTECS# Irritation Data: Section 5 -Toxicological Information May be harmful by inhalation, ingestion, or skin absorption. May cause irritation. To the best of our knowledge, the chemical, physical, and toxicological properties of the 3-D Microemulsion have not been investigated. Listed below are the toxicological information for glycerol, lactic acid and fatty acid. MA8050000 Glycerol SKN-RBT 500 MG/24H MLD EYE-RBT 126 MG MLD EYE-RBT 500 MG/24H MLD 85JCAE-,207,1986 BIOFX* 9-4/1970 85JCAE-,207,1986 Regenesis -3-D Microemulsion MSDS Toxicity Data: Target Organ Data: Section 5-Toxicological Information (cont) ORL-MUS LD50:4090 MG/KG SCU-RBT LD50:100 MG/KG ORL-RAT LD50:12,600 MG/KG IHL-RAT LC50: >570 MG/M3/1H IPR-RAT LD50: 4,420 MG/KG IVN-RAT LD50:5,566 MG/KG IPR-MUS LD50: 8,700 MG/KG SCU-MUS LD50:91 MG/KG IVN-MUS LD50:4,250 MG/KG ORL-RBT LD50: 27 MG/KG SKN-RBT LD50: > 10 MG/KG IVN-RBT LD50: 53 MG/KG ORL-GPG LD50: 7,750 MG/KG FRZKAP (6),56,1977 NIIRDN 6,215,1982 FEPRA 7 4,142,1945 BIOFX* 9-4/1970 RCOCB8 56,125,1987 ARZNAD 26,1581,1976 ARZNAD 26,1579,1978 NIIRDN 6,215,1982 JAPMA8 39,583,1950 DMDJAP 31,276,1959 BIOFX* 9-4/1970 NIIRDN 6,215,1982 JIHTAB 23,259,1941 Behavioral (headache), gastrointestinal · (nausea or vomiting), Paternal effects (spermatogenesis, testes, epididymis, sperm duct), effects of fertility (male fertility index, post-implantation mortality). Only selected registry of toxic effects of chemical substances (RTECS) data is presented here. See actual entry in RTECS for complete information on lactic acid and glycerol. Fatty Acids Acute oral (rat) LD50 value for fatty acids is 10000 mg/kg. Aspiration of liquid may cause pneumonitis. Repeated dermal contact may cause skin sensitization. Section 6 -Health Hazard Data One should anticipate the potential for eye irritation and skin irritation with large scale exposure or in sensitive individuals. Product is not considered to be combustible. However, after prolonged contact with highly porous materials in the presence of excess heat, this product may spontaneously com bust. Handling: Avoid continued contact with skin. Avoid contact with eyes. In any case of any exposure which elicits a response, a physician should be consulted immediately. First Aid Procedures Inhalation: Ingestion: Remove to fresh air. If not breathing give artificial respiration. In case of labored breathing give oxygen. Call a physician. No effects expected. Do not give anything to an unconscious person. Call a Regenesis -3-D Microemulsion MSDS Skin Contact: Eye Contact: Conditions to A void: Hazardous Polymerization: Further Information: physician immediately. DO NOT induce vomiting. Section 6 -Health Hazard Data ( cont) Flush with plenty of water. Contaminated clothing may be washed or dry · cleaned normally. Wash eyes with plenty of water for at least 15 minutes lifting both upper and lower lids. Call a physician. Section 7 -Reactivity Data Strong oxidizing agents, bases and acids Will not occur. Hydrolyses in water to form lactic acid, glycerol and fatty acids. Hazardous Decomposition Thermal decomposition or combustion may produce carbon monoxide Products: and/or carbon dioxide. After Spillage or Leakage: Disposal: Section 8 -Spill, Leak or Accident Procedures Neutralization is not required. The material is very slippery. Spills should be covered with an inert absorbent and then be placed in a container. Wash area thoroughly with water. Repeat these steps if slipperiness remains. Laws and regulations for disposal vary widely by locality. Observe all applicable regulations and laws. This material may be disposed of in solid waste. Material is readily degradable and hydrolyses in several hours. No requirement for a reportable quantity (CERCLA) of a spill is known. Section 9 -Special Protection or Handling Should be stored in plastic lined steel, plastic, glass, aluminum, stainless steel, or reinforced fiberglass containers. Protective Gloves: Eyes: Ventilation: Storage: Vinyl or Rubber Splash Goggles or Full Face Shield. Area should have approved means of washing eyes. General exhaust. Store in cool, dry, ventilated area. Protect from incompatible materials. Regenesis -3-D Microemulsion MSDS Section 10 -Other Information This material will degrade in the environment by hydrolysis to lactic acid, glycerol and fatty acids. Materials containing reactive chemicals should be used only by personnel with appropriate chemical training. The information contained in this document is the best available to the supplier as of the time of writing. Some possible hazards have been determined by analogy to similar classes of material. No separate tests have been performed on the toxicity of this material. The items in this document are subject to change and clarification as more information becomes available. Last Revised: Supplier: ~ Hydrogen Release Compound (HRC®) MATERIAL SAFETY DATA SHEET (MSDS) March 23, 2012 Section 1 -Material Identification REGENESIS 1011 Calle Sombra San Clemente, CA 92673 Phone: 949.366.8000 Fax: E-mail: Chemical Name: Chemical Family: Trade Name: Product Use: CAS# 201167-72-8 56-81-5 50-21-5 Melting Point: Boiling Point: Flash Point: Density: 949.366.8090 info @regenesis.com Propanoic acid, 2-[2-[2-(2-hydroxy-1-oxopropoxy)-1- oxopropoxy ]-1-oxopropoxy]-1,2,3-propanetriyl ester Organic Chemical Hydrogen Release Compound® (HRC®) Glycerol tripolylactate and Glycerol Used to remediate contaminated soil and groundwater ( environmental applications) Section 2 -Chemical Identification Chemical Glycerol Tripolylactate Glycerol Lactic Acid Section 3 -Physical Data Not Available (NA) Not Determined (ND) ND 1.3 glee Regenesis -HRC MSDS Solubility: Appearance: Odor: Vapor Pressure: Section 3 -Physical Data ( cont) Acetone and DMSO Viscous amber gel/liquid Not detectable None Section 4 -Fire and Explosion Hazard Data Extinguishing Media: Use Water Spray, Carbon Dioxide, Dry Chemical Powder or Appropriate Foam. Water may be used to keep exposed containers cool. For large quantities involved in a fire, one should wear full protective clothing and a NIOSH approved self contained breathing apparatus with full face piece operated in the pressure demand or positive pressure mode as for a situation where lack of oxygen and excess heat are present. Acute Effects: RTECS#: Irritation data: J:\Operations\MSDS\HRC MSDS Section 5 -Toxicological Information May be harmful by inhalation, ingestion, or skin absorption. May cause irritation. To the best of our knowledge, the chemical, physical, and toxicological properties of the glycerol tripolylactate have not been investigated. Listed below are the toxicological information for glycerol and lactic acid. MA8050000 Glycerol SKN-RBT 500 MG/24H MLD 85JCAE-,207,1986 EYE-RBT 126 MG MLD EYE-RBT 500 MG/24H MLD SKN-RBT 5MG/24H SEV EYE-RBT 750 UG SEV Page2 BIOFX* 9-4/1970 85JCAE-,207,1986 85JCAE -,656,86 AJOP AA 29,1363,46 Regenesis -HRC MSDS Section 5-Toxicological Information (cont) Toxicity data: Target Organ data: RTECS#: ORL-MUS LD50:4090 MG/KG FRZKAP (6),56,1977 SCU-RBT LD50:100 MG/KG ORL-RAT LD50:12600 MG/KG IHL- RA TLC50:>570MG/M3/1HBIO FX*9-4/1970 IPR-RAT LD50: 4420MG/KG IVN-RAT LD50: 5566 MG/KG IPR-MUS LD50: 8700 MG/KG SCU-MUS LD50: 91 MG/KG IVN-MUS LD50: 4250 MG/KG ORL-RBT LD50: 27 GM/KG SKN-RBT LD50:> l0GM/KG IVN-RBT LD50: 53 GM/KG ORL-GPG LD50: 7750 MG/KG ORL-RAT LD50:3543 MG/KG SKN-RBT LD50:>2 GM/KG ORL-MUS LD50: 4875 MG/KG ORL-GPG LD50: 1810 MG/KG ORL-QAL LD50: >2250 MG/KG NIIRDN 6,215,1982 FEPRA 7 4,142,1945 RCOCB8 56,125,1987 ARZNAD 26,1581,1976 ARZNAD 26,1579,1978 NIIRDN 6,215,1982 JAPMA8 39,583,1950 DMDJAP 31,276,1959 BIOFX* 9-4/1970 NIIRDN 6,215,1982 FMCHA2-,C252,91 FMCHA2-,C252,91 FAONAU 40,144,67 JIHT AB 23,259,41 FMCHA2-,C252,91 JIHTAB 23,259,1941 Behavioral (headache), gastrointestinal (nausea or vomiting), Paternal effects (spermatogenesis, testes, epididymis, sperm duct), effects of fertility (male fertility index, post- implantation mortality). OD2800000 Lactic acid Only selected registry of toxic effects of chemical substances (RTECS) data is presented here. See actual entry in RTECS for complete information on lactic acid and glycerol. J:\Operations\MSDS\HRC MSDS Page3 Regenesis -HRC MSDS Section 6 -Health Hazard Data Handling: Avoid continued contact with skin. Avoid contact with eyes. In any case of any exposure which elicits a response, a physician should be consulted immediately. First Aid Procedures Inhalation: Ingestion: Skin Contact: Eye contact: Conditions to Avoid: Hazardous Polymerization: Further Information: After Spillage or Leakage: Disposal: Remove to fresh air. If not breathing give artificial respiration. In case of labored breathing give oxygen. Call a physician. No effects expected. Do not give anything to an unconscious person. Call a physician immediately. Flush with plenty of water. Contaminated clothing may be washed or dry cleaned normally. Wash eyes with plenty of water for at least 15 minutes lifting both upper and lower lids. Call a physician. Section 7 -Reactivity Data Strong oxidizing agents, bases and acids None known Hydrolyses in water to form Lactic Acid and Glycerol. Section 8 -Spill, Leak or Accident Procedures Neutralization is not required. This material may be burned in a chemical incinerator equipped with an afterburner and scrubber. Laws and regulations for disposal vary widely by locality. Observe all applicable regulations and laws. This material, may be disposed of in solid waste. Material is readily degradable and hydrolyses in several hours. No requirement for a reportable quantity (CERCLA) of a spill is known. J:\Operations\MSDS\HRC MSDS Page4 Regenesis -HRC MSDS Section 9 -Special Protection or Handling Should be stored in plastic lined, steel, plastic, glass, aluminum, stainless steel, or reinforced fiberglass containers. Protective Gloves: Eyes: Ventilation: Storage: Vinyl or Rubber Splash Goggles or Full Face Shield Area should have approved means of washing eyes. General exhaust. Store in cool, dry, ventilated area. Protect from incompatible materials. Section 10 -Other Information This material will degrade in the environment by hydrolysis to lactic acid and glycerol. Materials containing reactive chemicals should be used only by personnel with appropriate chemical training. The information contained in this document is the best available to the supplier as of the time of writing. Some possible hazards have been determined by analogy to similar classes of material. No separate tests have been performed on the toxicity of this material. The items in this document are subject to change and clarification as more information becomes available. J:\Operations\MSDS\HRC MSDS Page 5