Loading...
HomeMy WebLinkAboutWQ0013505_Permit (Issuance)_19970310State of North Carolina . Depgrtment of Environment, Health and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director Mr. Thomas S Taylor, Town Administrator Town of Angier P.O. Box 278 Angier, North Carolina 27501 March 10, 1997 0 MAR 131997 FAYETTEVILLE REG. OFFICE Subject: Permit No. WQ0013505 Town of Angier Cambridge Subdivision Wastewater Collection System Harnett County Dear Mr. Taylor: In accordance with your application received February 26, 1997, attached is Permit No. WQ0013505, dated March 10, 1997, to the Town of Angier for the construction and operation of the subject wastewater collection extension. This permit shall be effective from the date of issuance until rescinded and you shall be subject to the conditions and limitations as specified in the North Carolina Gravity Sewer Design Criteria adopted February 12, 1996 and the attached permit. In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 3,125 linear feet of 8 inch gravity sewer to serve 55-three bedroom homes in Cambridge Subdivision and the discharge of 19,800 GPD of collected domestic wastewater into the Town of Angier's existing sewerage system, pursuant to the application received February 26, 1997, and in conformity with the North Carolina Gravity Sewer Design Criteria. The sewage and wastewater collected by this system shall be treated in the Town of Angier Wastewater Treatment Facility (NPDES Permit No. NC0082597) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone (919) 733-5083 FAX (919) 733-0719 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper If you need additional information concerning this matter, please contact Ms. Thelma Williams at . (919) 733-5083 extension 524. 4 Sincerely, afi1, Preston Howard, Jr., P.E. cc: Harnett County Health Department Fayetteville Regional Office, Water Quality Section Godwin, Jordan, Tew, & Associates, P.A. • NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES RALEIGH GRAVITY SEWER COLLECTION SYSTEMS PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of the Division of Water Quality Gravity Sewer Design Criteria adopted February 12, 1996. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The facilities must be properly maintained and operated at all times. 4. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of this permitted facility, a certification and a copy of the record drawings (i.e., as constructed plans) must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the Division of Water Quality Gravity Sewer Design Criteria adopted February 12, 1996, and other supporting materials. Mail the Certification and one (1) copy of the "Record Drawings" to the Water Quality Permits and Engineering Unit, P.O. Box 29535, Raleigh, NC 27626-0535. 7. A copy of the Record Drawings shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. 8. Failure to abide by the conditions and limitations contained in this general sewer permit or the North Carolina Gravity Sewer Design Criteria may subject the Permittee to an enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6(a) to 143- 215.6(c). 9. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater collection facilities. 1 10. Noncompliance Notification: The Permittee shall report by telephone to the Fayetteville Regional Office, telephone number (910) 486-1541, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five (5) days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 10th day of March, 1997. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION cL.L 7- i( Preston H ward, Jr., P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0013505 2 * Permit No. WQ0013505 March 10, 1997 ENGINEER'S CERTIFICATION , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, , for the Project Name Location Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit, the certificate of coverage, the North Carolina Gravity Sewer Minimum Design Manual, and other supporting materials. Signature Registration No. Date The above Engineer's Certification must be completed and submitted to the address below with one (1) copy of the "Record Drawings" (i.e., as -constructed plans) of the wastewater collection system This project shall not be considered complete and allowed to operate until this Engineer's Certification and the "Record Drawings" plans have been submitted. Any wastewater flow made tributary to the wastewater collection system prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 RALEIGH, NORTH CAROLINA 27626-0535 3 I- I -(- P. 1 Approval: •* * FILE MODE OPTION * COMMUNICATION RESULT REPORT ( MAR. 7.1997 3:22PM ) * * * TTI ENVIRONMENTAL MGMT RESULT PAGE ADDRESS (GROUP) 932 MEMORY TX 19197330719 OK P. 1/1 REASON TO FOR ERROR E-1) HANG UP OR LINE FAIL E-3) NO ANSWER umm-r- t F-ax : 919-733-0719 Feb 27 '97 13:45 P.01/01 Procedure 4 Request Form FROM: Michael Wicker, Water Quality Supervisor • E-2) BUSY E-4) NO FACSIMILE CONNECTION Fayetteville Regional Office, Water Quality Section FROM: Thelma Williams State Telepho(Engineering) 3 Review3 extension 524 Application Number 14 A Db 1350 S Applicant: ' 1. Project Name: Da+eREIERf,ED FAX (919) 733F07Y4 7 1997' FAYETTEVILLE County: 410 • , - REG. OFFICE Receiving Pacil,iry; „ I - �-- Permit Number: Flow Volume; GPb Flow Type: X Domestic Commercial Industrial Ellefi AMA 'NO Comments: Regional Signature; Application Number: Applicant: 1 Aft County: Project Name: Receiving Facility: Flow Vnhm,.• Permit Number. DEM-P & E I Fax:919-733-0719 Feb 27 '97 13:45 Procedure 4 Request Form TO FROM: Michael Wicker, Water Quality Supervisor Fayetteville Regional Office, Water Quality Section TO FROM: Thelma Williams State Engineering Review Group Telephone (919) 733-5083 extension 524 Application Number: 1,0 Q i 1350 5- Applicant: 'DIOR\ +r Anoilm Project Name: 01Lrv&6eigPf� 5(46 ►J.5; 0n or. Receiving Facility: inil Flow Volume: (ctl tO GPD Flow Type: County: P.01/01 DptieREEWED FAX (919) 733-0` 19 71997, FAYETTEVILLE REG. OFFICE elf Permit Number:/1('.6h s97 Domestic Commercial Industrial Approval: X Denial: Comments: Regional Signature: 3/0V/ 97 Application Number: County: Applicant: Project Name: Receiving Facility: Permit Number. Flow Volume: GPD Flow Type: Domestic Commercial Industrial Approval: Denial: &' ; neeR , Comments: Regional Signature: Application Number: County: Applicant: Project Name: Receiving Facility: Flow Volume: GPD Flow Type; Permit Number: Domestic Commercial Industrial Approval: Denial:i Comments: I Regional Signature: C1<F'X88/ P COMPLIANCE: EVALUATION ANALYSIS REPORT • 0,3/04i 97 PAGE •i PERMIT--NC0082597 PIP&.......001 . REPORT PERIOD: 9601 -96 t 2 LOC_- -E s 'ACIL.xtY--._ANGIER WWTP. TOWN QF DESIGN FLOW-- .5000 CLASS._- .'L.I: CA'TIO 7-•ANG :L'E; REGION/COUNTY---06 HARNETT 50050 00310 00530 ' 00610 :31616 50060 0 400 00010 MONTH 4 /MG I) BOD REsi 'T SS NH3-fit FEC CQL. x CHLORINE )0 -TEMP F .5000 F 24.0E F 30.0 r: 4.00 F 200.0 Not NOL 6 01 .340p 2. 80 1 7- .01 " 2. 4 15.789 10.69 10.56 96./02 .3937 • 5.25 7.6 .23 6.4 - 15.238 9.71 10.62 96/03 .3699 . 4.75 6..7 .00 • 5.3 16.190 10.29 11.30 1.IMIT F .5000 F 12.00 F 30.0 F. 2..00 F 200.0 NOL NOL 76/04 ,3672 1.. {5 . Oil 3.4 1 7. 61 9. 9. 39 14.80 96, ,35 .3162 2.20 0 .21 3.9 1 7.7.27 4 34 19.87 .96/06 . 231 ti 2.00 0 .30 10.8 16.000 7.95 23 96/07 .2175 2..80 .0 ..00 3..8 16.818 .'t".63 25.53 6.•'08 .3343 2.50 - 0 .0Q 2 3 1 `a . 909 7.87 2,4.80 • '5"6/09 .4091. 2.75 ..? . 12 1.9 17.500 7.84 23.71 196./' 10 .4103 2..00 .0 .20 1 '. 9 16 . 086 8 . 36 , 20 . 25 - L I. tM I t F ...5000 F 24.00 F 30.0 F . ,4 . ;10 F 200.0 NOL .NOL... 96/ 1 1 .3522 1.75. :0 . ..00, 6.6 • 18.333 9. 1 8 16.20 96.i 1 2 .4100 i1 .•7.. 20 3.0 .03 3 4.9 17.894 9.53 13.55 AVE:RAGE . 3459 2. 7.") 1.5 .09 4.4 16.758 8.89 17.91 MAXIMUM .6550 9.00 16.0 1.06 89..E ' '0. 000 1 1 .70 26.50 MINIMUM .0000 L.E S : HAN LE:SSTHAN LE :....HAiN L.E:4CTHAN 10.000 , 7,10 8.00 UNIT MGD MG/L MG,/L MG/L 1 / 1 OOML. UG/L MG/L. DEG . C } h •. �arKEX$ 8% MP 03i'Q4%? i COMPLIANCE EVALUATION ANALYSIS REPORT PA E • 2 I PERMIT'7---NCoo82597PIPE --001 REPORTPERIOD: 9601-•9612 LOC---E ff ACIL.ITY-•-r NGIER WWTP, •TOWN OF DESIGN FLOW-- - .5000 CLASS--3 . 4.QC ATIONLANGIEN • R'EGION/COUNTY•---06 HARNET T 00400 ,00600 00665' 01051 4ONTH PH TOTAL• N • PHO;i'••••'TO'T LEAD IiEI'T 9., 0 6.0 NOL NOE.. NOL 6/01 • 6.9-6. 3 1.580 1 .2400- .0000 96/02 6.876. i .1 .420 • .9060 .0000 76/03 . 6.8-6. i. .0000 TMIT 9.0 6.0 NOL NOL. NOL • 6/04 • 6.9-6.4 .640 1 .0300 i'6i 05. 7.0 -6.4 ►'6/06 7. 1 -6. 4 96i :) e' 6.9-6.4 13. 6.407. 7000 P6/08 :6. 9 -6.3 06 09 6.9-6, 3 fri6/10 6.9-6.3 10.250 1,1400 ..IMIT 9.0f 6.0 Nit NOL NOL. ?6.r 1 1 6.8-6.2 96/12 6 , 7.6.3 6VERAGE 5.506 1 .4032 .0000 3AXI!MUM 7.100 1 3.640 2.7000 MINIMUM 6.400 .640 .9060 UNIT SU MG/L ' MG./L. MG/L f . State of North Carolina .Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Govemor Wayne McDevitt, Secretary A. Preston Howard, Jr., P.E., Director THOMAS S. TAYLOR ANGIER, TOWN-CAMBRIDGE SUBDIV PO BOX 278 ANGIER, NC 27501 Dear Permittee: April 20, 1998 RECEIVED HAY 0 4 1998 FAY it iTEV! 1IE REG. OFFICE Subject: CERTIFICATE OF COMPLETION PERMIT NO. WQ0013505 ANGIER, TOWN-CAMBRIDGE SUBDIV HARNETT COUNTY On March 10, 1997 the Division of Environmental Management issued you the subject permit. One of the conditions of the subject permit read as follows: Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the requirements of this permit and the approved plans and specifications. Mail certification to the Permits and Engineering Unit, P.O. Box 29535, Raleigh N.C., 27626-0535. To date, our records show that no certification has been received for the subject permit. If the permitted facility has been constructed and placed into operation please submit the required certification immediately. Operation of the treatment system prior to submission of the required certification is in violation of your permit and is subject to enforcement action. If you have any questions, please contact consulting engineer for this project, GODWIN-JORDAN-TEW & ASSOC at (910)892-5159. If the facility has not been constructed, please contact the Fayetteville Regional Office at (910)486-1541, so that they can update their records. Thank you for your prompt attention to this matter. Sincerely, L6 / (1/(111 61 :Kim H. Colson, P.E., Supervisor State Engineering Review Group i cc: Fayetteville Regional Office File P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone (919) 733-7015 FAX (919) 733-0719 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper