Loading...
HomeMy WebLinkAboutWM0701248_Application_20210506NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1. Date: April 23, 2021 2. County: Currituck 3. 4. Applicant: Oak Trail Solar, LLC FOR OFFICE USE ONLY PERMIT NO. ISSUED DATE What type of well are you applying for? (monitoring or recovery): monitoring well (1) Telephone: (281) 509-6248 Applicant's Mailing Address: 800 Town and Country Boulevard, Suite 500, Houston, TX 77024 Applicant's Email Address (if available): 5. Contact Person (if different than Applicant): Chris Pruneau Telephone: (910) 231-2955 Contact Person's Mailing Address: 5710 Oleander Drive, Suite 110, Wilmington, NC 28403 Contact Person's Email Address (if available): Chris.pruneau@woodplc.com 6. Property Owner (if different than Applicant): FPI Carolinas LLC Telephone: (720) 452-2713 Property Owner's Mailing Address: 4600 S SYRACUSE ST STE 1450, DENVER, CO 80237 Property Owner's Email Address (if available): 7. Property Physical Address (Including PIN Number) PIN: 1100000010000 (off Puddin Ridge Rd.) City Moyock County Currituck Zip Code 27958 8. Reason for Well(s): Baseline groundwater monitoring (ex: non -discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed: solar energy facility (ex: non -discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). No 11. Type of contaminants being monitored or recovered: No known contamination is present (ex: organics, nutrients, heavy metals, etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many? No Existing Monitoring or Recovery Well Construction Permit No(s).: 13. Distance from proposed well(s) to nearest known waste or pollution source (in feet): N/A 14. Are there any water supply wells located less than 500 feet from the proposed well(s)? None known If yes, give distance(s): 15. Well Contractor: Regional Probing Services Certification No.: 3322 Well Contractor Address: PO Box 1161 Wake Forest NC 27588 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons c. Screen intervals g. Well head completion details d. Sand/gravel pack intervals Continued on Reverse PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated material: 1 3. Number of wells to be constructed in bedrock: N/A 4. Total Number of wells to be constructed: 1 (add answers from 2 and 3) 5. How will the well(s) be secured? Locking steel cover, cemented into concrete pad 6. Estimated beginning construction date: 5/15/21 7. Estimated construction completion date: 5/31/21 1. ADDITIONAL INFORMATION As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. c. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant hereby agrees that the proposed well(s) will be constructed in accordance with approved specifications and conditions of this Well Construction Permit as regulated under the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C) and accepts full responsibility for compliance with these rules Dm cam. 46Bud z% - Authorized Signatory Signature of Applicant or *Agent Title of Applicant or *Agent Omar Aboudaher * If signing as Agent, attach authorization agreement stating Printed name of Applicant or *Agent that you have the authority to act as the Agent. If the property is owned by someone other than the applicant, the property owner hereby consents to allow the applicant to construct wells as outlined in this Well Construction Permit application and that it shall be the responsibility of the applicant to ensure that the .well(s) conform to the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C). Signature of Property Owner (if different than Applicant) FPI Carolinas LLC Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources' Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 3800 Barrett Drive Raleigh, NC 27609 Phone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 Wilmington, NC 28405 Phone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 01/4 it .i� Wil ngron GW-22MR Rev. 3-1-2016 Raleigh Regional Office Wilmington Regional Office 127 Cardinal Drive Extension GW-22M (Rev. 5/11) DocuSign Envelope ID: OBEE85CC-FF19-4043-972B-5702EB4C20E1 IYVR I rI VNRVLIIYr► UCrNR 11Y1CIY I .jr- CIY V 11WIJMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1. Date: April 23, 2021 2. County: Currituck 3. 4. Applicant: Oak Trail Solar, LLC FOR OFFICE USE ONLY PERMIT NO. ISSUED DATE What type of well are you applying for? (monitoring or recovery): monitoring well (1) Telephone: (281) 509-6248 Applicant's Mailing Address: 800 Town and Country Boulevard, Suite 500, Houston, TX 77024 Applicant's Email Address (if available): 5. Contact Person (if different than Applicant): Chris Pruneau Telephone: (910) 231-2955 Contact Person's Mailing Address: 5710 Oleander Drive, Suite 110, Wilmington, NC 28403 Contact Person's Email Address (if available): Chris.pruneau@woodplc.com 6. Property Owner (if different than Applicant): Karen Jarvis a/k/a Karen Lea Jarvis Telephone: (252) 435-3942 Property Owner's Mailing Address: 301 LYNDEN LN, NEW BERN, NC 28560 Property Owner's Email Address (if available): 7. Property Physical Address (Including PIN Number) PIN: 1000000110000 (Puddin Ridge Rd.) City Moyock County Currituck Zip Code 27958 8. Reason for Well(s): Baseline groundwater monitoring (ex: non -discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed: solar energy facility (ex: non -discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). No 11. Type of contaminants being monitored or recovered: No known contamination is present (ex: organics, nutrients, heavy metals, etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many? No Existing Monitoring or Recovery Well Construction Permit No(s).: 13. Distance from proposed well(s) to nearest known waste or pollution source (in feet): N/A 14. Are there any water supply wells located less than 500 feet from the proposed well(s)? None known If yes, give distance(s): 15. Well Contractor: Regional Probing Services Certification No.: 3322 Well Contractor Address: PO Box 1161 Wake Forest NC 27588 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons c. Screen intervals g. Well head completion details d. Sand/gravel pack intervals Continued on Reverse DocuSign Envelope ID: OBEE85CC-FF19-4043-972B-5702EB4C20E1 rr<vrvomu VVIM 0 i mUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated material: 1 3. Number of wells to be constructed in bedrock: N/A 4. Total Number of wells to be constructed: 1 (add answers from 2 and 3) 5. 6. 7. Estimated construction completion date: How will the well(s) be secured? Locking steel cover, cemented into concrete pad Estimated beginning construction date: 5/15/21 5/31/21 1. ADDITIONAL INFORMATION As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. c. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant hereby agrees that the proposed well(s) will be constructed in accordance with approved specifications and conditions of thi lgiL,ge t6}iction Permit as regulated under the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C) and accepts full responsibility for compliance with these rules V kto.,44.1nu- 0F17E7D8513343E... Signature of Applicant or *Agent Omar Aboudaher Printed name of Applicant or *Agent Authorized Signatory Title of Applicant or *Agent * If signing as Agent, attach authorization agreement stating that you have the authority to act as the Agent. If the property is owned by someone other than the applicant, the property owner hereby consents to allow the applicant to construct Ikcggoitlicied in this Well Construction Permit application and that it shall be the responsibility of the applicant to ensure that the conform to the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C). 2234E7C2B85C49C... Karen Jarvis a/k/a/ Karen Lea Jarvis Signature of Property Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources' Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 3800 Barrett Drive Raleigh, NC 27609 Phone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 kei al .4 I Wilmington, NC 28405 Phone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 k\4. *�a a111'—'7' 414 ngtan GW-22MR Rev. 3-1-2016 Raleigh Regional Office Wilmington Regional Office 127 Cardinal Drive Extension GW-22M (Rev. 5/11) DocuSign Envelope ID: 8749C73F-D46E-4D59-A602-BE634F209F51 IYVIr I rI VNrwLIIVr► UCrNR I ivi I .jr- CI9 V 11WIJMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1. Date: April 23, 2021 2. County: Currituck 3. 4. Applicant: Oak Trail Solar, LLC FOR OFFICE USE ONLY PERMIT NO. ISSUED DATE What type of well are you applying for? (monitoring or recovery): monitoring well (1) Telephone: (281) 509-6248 Applicant's Mailing Address: 800 Town and Country Boulevard, Suite 500, Houston, TX 77024 Applicant's Email Address (if available): 5. Contact Person (if different than Applicant): Chris Pruneau Telephone: (910) 231-2955 Contact Person's Mailing Address: 5710 Oleander Drive, Suite 110, Wilmington, NC 28403 Contact Person's Email Address (if available): Chris.pruneau@woodplc.com 6. Property Owner (if different than Applicant): Charles D. Jarvis Telephone: (252) 339-9662 Property Owner's Mailing Address: 1211 TOXEY RD, ELIZABETH CITY, NC 27909 Property Owner's Email Address (if available): cdj@reagan.com 7. Property Physical Address (Including PIN Number) PIN: 0010000018D0000 (Puddin Ridge Rd.) City Moyock County Currituck Zip Code 27958 8. Reason for Well(s): Baseline groundwater monitoring (ex: non -discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed: solar energy facility (ex: non -discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). No 11. Type of contaminants being monitored or recovered: No known contamination is present (ex: organics, nutrients, heavy metals, etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many? No Existing Monitoring or Recovery Well Construction Permit No(s).: 13. Distance from proposed well(s) to nearest known waste or pollution source (in feet): N/A 14. Are there any water supply wells located less than 500 feet from the proposed well(s)? None known If yes, give distance(s): 15. Well Contractor: Regional Probing Services Certification No.: 3322 Well Contractor Address: PO Box 1161 Wake Forest NC 27588 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons c. Screen intervals g. Well head completion details d. Sand/gravel pack intervals Continued on Reverse DocuSign Envelope ID: 8749C73F-D46E-4D59-A602-BE634F209F51 rrwrvomu %AMMO I rcUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated material: 1 3. Number of wells to be constructed in bedrock: N/A 4. Total Number of wells to be constructed: 1 (add answers from 2 and 3) 5. How will the well(s) be secured? Locking steel cover, cemented into concrete pad 6. Estimated beginning construction date: 5/15/21 7. Estimated construction completion date: 5/31/ 1. ADDITIONAL INFORMATION As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. c. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant hereby agrees that the proposed well(s) will be constructed in accordance with approved specifications and conditions of this tglgsg9§3rNption Permit as regulated under the Well Construction Standards (Title 15A of the North Carolina Administrative Code, MAC A bum Subchapter 2C) and accepts full responsibility for compliance with these rules 0F17E7D8513343E... Signature of Applicant or *Agent Omar Aboudaher Authorized Signatory Title of Applicant or *Agent * If signing as Agent, attach authorization agreement stating Printed name of Applicant or *Agent that you have the authority to act as the Agent. If the property is owned by someone other than the applicant, the property owner hereby consents to allow the applicant to construct wells as utlped in this Well Construction Permit application and that it shall be the responsibility of the applicant to ensure that the co � o u ignfn d by: well s� orm to the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C). S jtxvvus '-Q8Q44Q63FD174B8 Charles D. Jarvis Signature of Property Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources' Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 3800 Barrett Drive Raleigh, NC 27609 Phone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 AMMER Wilmington, NC 28405 Phone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 k\4. *�a a111'—'7' 414 ngtan GW-22MR Rev. 3-1-2016 Raleigh Regional Office Wilmington Regional Office 127 Cardinal Drive Extension GW-22M (Rev. 5/11) 1 2 3 4 5 6 7 8 9 10 A B C D E F G H J K L N/F GARRETT BROTHERS FARM INC. PARCEL # 0006000013A0000 AG COOPER GA N/F GARRETT BROTHERS FARM INC. PARCEL # 0006000013A0000 AG FLOOD CONTROL DEVICE 096 Gvi / / /L 150' BOUNDARY SETBACK N/F BLUE SKY REAL ESTATE LLC PARCEL # 000600000160000 AG PROPOSED SITE ACCESS ROAD N/F BLUE SKY REAL ESTATE LLC PARCEL # 000700000030000 AG N/F GILL PARCEL # 0006000009130000 AG i / PROPOSED MONITORING WELL N: 1015415.00 E: 2822272.12 / / 1 / / N/F JARVIS PARCEL # 001000000100000 AG / .j PROPOSED SITE ENTRANCE 1 LE ANDING = E.KJ4', SHINGLE J— N/F BRICKHOUSE PARCEL # 001000000150000 AG •• APPROX LOCATIO OF PCS TY P OSED SITE ENTRANCE 4 S N/F BRICKHOUSE PARCEL # 001000000150000 AG GvINE \ q M Nq` q TFRgC q C,a N/F BLUE SKY REAL ESTATE LLC PARCEL # 000700000040000 AG SITE ENTRANCE 3 N/F DAVIS PARCEL # 001000000290000 AG / / D • / / / / -X N/F BIRTELL PARCEL # 001000000160000 AG PROPOSED SITE ENTRANCE 2 N/F ROMM PARCEL # 001000000900000 AG / N/F BRICKHOUSE PARCEL # 001000001880000 AG PROPOSED ,�4'h�� SECURITY FENCE �rSo! 0 .____jcz.. m' o� e a- O N/F BURNS PARCEL # 0010000017A0000 N/F DOSHEN PARCEL # 001000001713000 N/F JOHN PARCEL # 0010000017C0000. * • "OPOSED MONITORI N: 1018975.47 E: 2823306.35 N/F GODFREY PARCEL # 0010000021A0000 N/F GODFREY PARCEL # 0010000025A0000 PROPOSED SITE ENTRANCE 5 N/F HARBBY PARCEL # 0010000009F AG N/F ROMM PARCEL # 0010000009F0000 AG qR N/F \°po oF< �' op,00N040 A° 0o ,BGppp° /1/ 1 01 01 PROPOSED DEDICATED ACCESS ROAD TO SUBSTATION AND SWITCHYARD 0 SITE BOUNDARY NG W 2 S 1./ FPI CAROLINAS INC PARCEL # 001000000190000 SFM •\ FLOOD CONTROL DEVICE 022 00o05 A SITE DATA TABLE PARCELS 001100000010000; 000600000120000; 000600000120000; 001000000130000; 001000000110000; 001 000001 8F0000; 001000001 4A0000; 001000000120000; 001000001 8D0000 ZONING AG — AGRICULTURAL ADJACENT ZONING AG — AGRICULTURAL TOTAL SITE AREA 1,126.4± AC EXIST DOMINION 230 kV TRANSMISSION CORRIDOR —PROPOSED MONITORING WELL N: 1014456.30 E: 2829698.22 41 I Irr iti# a • • 11# 10 twl : :ft" fistottottstsitsts siiiam dir N/F LINDSOY PARCEL FLOOD CONTROL DEVICE 034 AG AG \ .-_�. AGAGAG AG "7.' G F 00 t1M 0 HOLDINGS LLC 1 ooa20000z0000 AG \\ G PROPOSED N SWITCHYARD AG AG �� AG AG AG CaI rigo# Pe= UM= N. wil ale: If: um ltall = INEE• To go MI NS MA MI iIII NE mg MN INN 44/11. Se big . # D: II: ' SCE 000/111 ME IPS 110 MS Ell MIN all Me in MIN N/F LAKE VIEW LAND DEOELO EN PARCEL # 001500008 0000 SFM N/F EAGLE CR PARCEL 1," A T LLC LLC INC FLOOD CONTROL DEVICE 032 600' 300' 0 600' SCALE: 1 "=600' 1200' 1800' REV DATE REVISION DESCRIPTION BY CHK APP WOO WOOD ENVIRONMENT & INFRASTRUCTURE SOLUTIONS, INC. 4021 STIRRUP CREEK DRIVE, SUITE 100 DURHAM, NC 27703 T: 919 381 9900 I WWW.WOODPLC.COM ENGINEERING: F-1253 NC GEOLOGY: C-247 OAK TRAIL SOLAR, LLC 800 TOWN AND COUNTRY BLVD, SUITE 500 HOUSTON, TX 77024 PHONE: (281) 906-0382 TITLE: OAK TRAIL SOLAR, LLC CURRITUCK COUNTY, NORTH CAROLINA, USA PROJECT: 100 MWac NOMINAL CAPACITY SOLAR PV SYSTEM FOR P EAR? MIr1T Ir J AG SHEET TITLE: MONITORING WELL EXHIBIT PROJ. MGR. M. CROOK PROJ. ENGR. E. NEVAREZ DR. BY KMV CHK. BY XXX SCALE: PROJ. DIRECTOR TBD JOB No. SYS-00XXX PROJECT CODE OAK1 DRAWING No 1 OF 1 REV. A GREGORY THOMPSON, P.E. NC P.E. LICENSE NO. 21155 DATE THIS PRINT IS NOT TO BE USED FOR CONSTRUCTION UNLESS NOTED AND SIGNED OK FOR CONSTRUCTION ABOVE LAST REVISION. C:\Users\kenneth.veal\Desktop\nc\cad\Plans\OAK-MONITORING WELL EXHIBIT.dwg kenneth.veal Apr 19, 2021 - 2:58pm 5 Wood E&IS, Inc. Wilmington, NC W lm Oleander Drive, Suite 110 wood. Phone: (910) 452-1185 TYPE II MONITORING INSTALLATION RECORD JOB NAME TBD BACKFILL MATERIAL TORPEDO SAND JOB NUMBER TBD SCREEN SLOT SIZE 0.01 - INCH WELL NUMBER TBD SCREEN MATERIAL PVC INSTALL DATE TBD RISER MATERIAL PVC LOCATION TBD SCREEN DIAMETER 1.5 - INCH GROUND ELEVATION TBD RISER DIAMETER 1.5 - INCH REFERENCE ELEVATION TBD BOREHOLE DIAMETER 3 - INCH WOOD REPRESENTATIVE Pruneau LOCK BRAND MASTER DRILLING CONTRACTOR Regional Probing Services SIZE / MODEL NO. 4 DRILLING TECHNIQUE Geoprobe KEY CODE TBD STEEL PROTECTIVE LOCKABLE COVER HEIGHT OF STICK UP 2.5' 2' x 2' CONCRETE PAD BENTONITE/GROUT SEAL DEPTH TO TOP OF BENTONITE 16.0' SEAL DEPTH TO TOP BENTONITE SEAL OF SAND 18.0' TOTAL DEPTH OF BOREHOLE SOLID RISER PIPE 20.0' SCREEN INTERVAL SAND PACK 15.0' LENGTH OF SCREEN WELL SCREEN 5_0' WELL CAP 120.0' NOTES: REFERENCE ELEVATION = TBD CREATED BY: WJM 3/26/21