Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW6210402_Calcs (Outlets)_20210504
OUTLET PROTECTION DATEDESIGN PHASE DESIGN 02-25-21PRELIM/ / PROJECT NAMEPROJECT NOCONSTR/ X / Woodhaven Subdivision1721REVISION/ / LOCATIONBYRECORD/ / Hoke County, North CarolinaCEKOTHER/ / CHECKED BY(SPECIFY) CSB Storm Outlet Structure 10/Qfull = FES No.=FES-4Q0.98 Pipe Dia=18 inV/Vfull = 1.14 Q 10=8.87 cfsV =5.8fps Qfull =9.01 cfs Vfull = 5.09 fps From Fig. 8.06.b.1:Zone=2 D 50 From Fig. 8.06.b.2:=8 in D MAX =12 in Riprap Class=B Apron Thickness=18 in Apron Length=9.0 ft Apron Width @ Outlet=4.5 ft Apron Width @ End=10.5 ft Storm Outlet Structure FES No.=FES-11Q 10/Qfull =1.01 Pipe Dia=18 inV/Vfull = 1.14 Q 10=9.46 cfsV =6.0fps Qfull =9.33 cfs Vfull =5.27 fps From Fig. 8.06.b.1:Zone=2 From Fig. 8.06.b.2:D 50=8 in D MAX=12 in Riprap Class=B Apron Thickness=18 in Apron Length=9.0 ft Apron Width @ Outlet=4.5 ft Apron Width @ End=10.5 ft Storm Drainage for Spread.xlsLATEST REVISION: 5/4/2021 9:24 AMPAGE 1 OF 3 OUTLET PROTECTION DATEDESIGN PHASE DESIGN 02-25-21PRELIM/ / PROJECT NAMEPROJECT NOCONSTR/ X / Woodhaven Subdivision1721REVISION/ / LOCATIONBYRECORD/ / Hoke County, North CarolinaCEKOTHER/ / CHECKED BY(SPECIFY) CSB Storm Outlet Structure Q 10/Qfull =0.99 FES No.=FES-19 Pipe Dia=36 inV/Vfull = 1.14 Q 10=38.24 cfsV =6.2fps Qfull =38.51 cfs Vfull = 5.44 fps From Fig. 8.06.b.1:Zone=3 From Fig. 8.06.b.2:D 50=10 in D MAX=15 in Riprap Class=1 Apron Thickness=22.5 in Apron Length=24.0 ft Apron Width @ Outlet=9 ft Apron Width @ End=27.0 ft Storm Outlet Structure 10/Qfull = FES No.=FES-26Q0.43 Pipe Dia=18 inV/Vfull = 0.96 Q 10= 3.12 cfsV =3.9fps Qfull =7.28 cfs Vfull =4.11 fps From Fig. 8.06.b.1:Zone=2 50 From Fig. 8.06.b.2:D=8 in D MAX =12 in Riprap Class=B Apron Thickness=18 in Apron Length=9.0 ft Apron Width @ Outlet=4.5 ft Apron Width @ End=10.5 ft Storm Drainage for Spread.xlsLATEST REVISION: 5/4/2021 9:24 AMPAGE 2 OF 3 OUTLET PROTECTION DATEDESIGN PHASE DESIGN 02-25-21PRELIM/ / PROJECT NAMEPROJECT NOCONSTR/ X / Woodhaven Subdivision1721REVISION/ / LOCATIONBYRECORD/ / Hoke County, North CarolinaCEKOTHER/ / CHECKED BY(SPECIFY) CSB Storm Outlet Structure Q 10/Qfull =0.91 FES No.=FES-31 Pipe Dia=18 inV/Vfull = 1.13 Q 10=8.24 cfsV =5.8fps Qfull =9.06 cfs Vfull = 5.12 fps From Fig. 8.06.b.1:Zone=2 From Fig. 8.06.b.2:D 50=8 in D MAX=12 in Riprap Class=B Apron Thickness=18 in Apron Length=9.0 ft Apron Width @ Outlet=4.5 ft Apron Width @ End=10.5 ft Storm Outlet Structure 10/Qfull = FES No.=FES-35Q0.59 Pipe Dia=18 inV/Vfull = 1.04 Q 10= 4.85 cfsV =4.8fps Qfull =8.18 cfs Vfull =4.63 fps From Fig. 8.06.b.1:Zone=2 50 From Fig. 8.06.b.2:D=8 in D MAX =12 in Riprap Class=B Apron Thickness=18 in Apron Length=9.0 ft Apron Width @ Outlet=4.5 ft Apron Width @ End=10.5 ft Storm Drainage for Spread.xlsLATEST REVISION: 5/4/2021 9:24 AMPAGE 3 OF 3