Loading...
HomeMy WebLinkAboutWQ0042417_Application (FTSE)_20210326DocuSlgn Envelope ID: 2E7AFC28-7BO94880-BC2C-72E95526ED85 State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Dlvlslon of Water Resources F-TA 04-16 & SUPPORTING DOCUMENTATION Application Number: 0001AMI (lobe complcicd by DWR) All items must be completed or the anplication will he returned I. APPLICANT INFORMATION: . Applicant's name: Town of Fuquav-Varina (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual [I Corporation ❑ General Partnership ❑ Privately -Owned Public ]Jti.ity ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Jay Meyers, PE per I SA NCAC 02T .0106(b) Title: Town of Fuquay-Varina Public Utilties Director 4. Applicant's mailing address: 134 N main St. City: Fuquav-Varina State: NC Zip: 27526 5. Applicant's contact information: Phone number: 9(,_19) 567-3911 Email Address: jmeyers aQfuauay-varina.org H. PROJECT INFORMATION: 1. Project name: South Lakes, SF-8 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number; WQ00 . 01 3. County where project is located: Wake u 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.582127' Longitude:-78.742587' 4 5. Parcel ID (if applicable): 0676669690 (or Parcel ID to closest downstream sewer) M. CONSULTANT INFORMATION: c� Q_— I. Professional Engineer: Debra Fenn License Number: 28892 4 .� u 40 Firm: WithersRavencl, Inc. A ti U Mailing address: 115 MacKenan Dr. City: C_ Ary State: NC Zip: 27511- Phone number: 9( 19) 469-3340 Ismail Address. dfcrm@—withersravenel.com IV. WASTEWATER TREATIMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Terrible Creek WWTP Permit Number: NCO00066516 Owner Name: Town of Fuquav-Varina V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): W 00Q 39812 Downstream (Receiving) Sewer Size; 8" inch System Wide Collection System Permit Number(s) (if applicable): WQCSWj 13 Owner Name(s): Fuguay-Varina FORM: FTA 04-16 Page ' oF5 DocuSign Envelope ID: 2E7AFC28-7B094BB0•BC2C-72E95526ED85 VI. GENERAL REQUIRE, ENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [:]No ®NIA 2. If the Applicant is a Developer of lots to be sold, has a Developer's. Operational Agreement (FORM: DEVI been attached? ❑ Yes ❑No ®NIA 3. If the Applicant is a Home/Property,Owners' Association has an Operational A eement FORM: 1IOA been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparadon/service ❑ Hotel and/or Motels ❑ School / preschool I day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Horne ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAtr 02T .0103(20)) 4 Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f)? 0. Yes ❑ No If yes, provide a cony of flow reduction approval letter 7. Summarize wastewater generated by project: Estab�lishntent'rype (see 02T.01140 Daily Design Flow °.b No. of Units Flow i i3 WrivA sin le. 75*3.5 gal/bdr 65 17,063 GPD gall GPD gall GPD gall GPD gal/ GPD gall GPD Total 17,063 GPD a See 15A NCAC 02T ,0I 14 b d e 1 and e 2 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 1 SA NCAC 02T.01141 shall be detennined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. S. Wastewater generated by project; 17,063 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number; ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): NORM: F`I'A 04-16 Page 2 of 5 DocuSlgn Envelope ID: 2E7APC28-7Bo9-4BB0-BC2G72E95526ED85 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 2,628 PVC D Section H & III of #lie MDC f'or Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewcr(s) D Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VII1. PUMP STATION DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT Pump station number or name: South Lakes. SF-8 2. Approximate Coordinates (Decimal Degrees): Latitude: 35.558212' Longitude:-78.742587:' 3. Design flow of the pump station: 0.1656 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): l 15 gallons per minute at 97 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 4" 4,793 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_ ➢ Required for a:I pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - I5A NCAC 02T .0305(it)(1)(C): D It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage_ FORM: PTA 04-16 Page 3 of 5 DocuSign Envelope ID: 2E7AFC28-7B094B80-BC2C-72E95526ED85 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & (g) ❑ Yes ❑ No ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet "Any private or public water supply source, including any wells, WS-I waters of Class I or r Class II impounded reservoirs used as a source of drinking water *'"Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SR from normal high water Lor tide elevation and wetlands see item IX.2 100 feet 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any buil ing foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains Any swimming pools - 5 feet 10 feet j Final earth grade (vertical) 36 inches D 15A tiC AfLQ2T.03P5W contains aiternatives where separations in 02T.0305(f) cannot be achieved. D **Stream classifications can be identified using the Division's NC Surface Water Classifications webnage ➢ If noncompliance with 02T.0305(�f or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes [:]No ❑ N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ❑ NIA ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does (lie project require coverage,'authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Pen-nittiniz Branch 5. Does project comply with 15A NCAC 02T.0105(c)(61(additional permits?certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained, issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to strearnbanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ MA ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall he inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 DocuSign Envelope ID: 2E7AFC28-7B09-4B80-BC2C-72E95526ED65 X. CERTIFICATIONS: I. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations_ and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the VariancerAlternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the renuest is renuired prior to submittal of the Fast Track Application and supporting; documents. 2. Professional Engineces Certification: Debbi Ferm, P. E. attest that this application for (Professional Engineer's name from Application Item III.I .) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the mast -Track Permitting of Pump Stations and force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0 [ 06(b): T Maven, --L name & title from Application Item 1.3.) C A R �oeOOO e'°vaeeeeeaes F'SS/pyet Q �o n SEAL e e b C � 028892 f o °b O GG 0 b +G I N e _puaoao9pp0<° that (his application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will resuit in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: I? Mock &m FORM: FTA 04-16 Page 5 of 5 State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (F TSE 10-18) Entity Requesting Allocation: Townf Fuquay-Varina Project Name for which flow is being requested: South Lakes SF-8 Single Family More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for al! pump stations along the route of the proposed wastewaterJlow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Terrible Creek WWTP b. WWTP Facility Permit #: NCO066516 All flows are in MGD c. WWTP facility's permitted flow 3.000 d. Estimated obligated flow not yet tributary to the WWTP 0.925 e. WWTP facility's actual avg. flow 1.152 £ Total flow for this specific request 0.017 g. Total actual and obligated flows to the facility 0.942 h. Percent of permitted flow used 69.80% Il. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx_ Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No, MGD MGD Flow, MGD MGD Flow Capacity*** Eastern n0017887 n „r 1.800 0.720 0.256 0.157 0.413 0.307 Holly 0.432 0.173 0.094 0.090 0.184 -0.021 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): South Lakes SF-8 (infrastructure - zero Downstream Permit Number: 39812 Page 1 of 6 FTSE 10- I 8 III. Certification Statement: I JM T Meyers, PE certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the [low from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Title of Signing Official Page 2 of 6 ):TSE 10-18 PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section Il where Available Capacity is 0. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily FIow (C) accounts for 52% % and 0.090 MGD of the Available Capacity (E) in Pump Station Holly Ridge PS ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0.045 M G D per year; and that c. A funded Capital Project that will provide the required planned capacity, namely Holly Ridge Pump Station Upgrade is in design or under construction with planned completion in 202I ; and/or d. The following applies: The Holly Sprites Pump Station Upgrade is currently under construction to expand pumping capacity to a firm capapcity of 860 gallons per minute, or 0.495 mgd average day. The project is anticipated to be completed during the summer of 2021. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143- 215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. I,Z(14L ZOZ Date Page 3 of 6 FTSF 10-18 State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Gregory J. Thorpe, Ph.D., Acting Director November7, 2001 Mr. Michael A. Allway, Assistant Town Manager Town of Fuquay-Varina 401 Old Honeycutt Road Fuquay-Varina, North Carolina 27526 Subject: Dear Mr. Allway_ NCDENR NORTH CAROUNA DEPARTMENT OF ENVIRONMENT ANO NATURAL_ RESOURCES '. W, tf um of PALw-da" Town of Fuquay-Varina Flow Reduction Approval Wake County On Septem-er 10. 2001. the Division of Water Qua:iry Non Discharge Permitting Unit received your flow reduction request for future and present, but not yet tributary, single-family dwellings in the Town of Fuquay-Varina_ The letter requests approval of a residential flow value of 220 GPD/residence for these dwellings. The information provided water use information for 2000 and actual daily waste water flow recordings for their peak month of May. Other supporting data was provided. The evaluation covered 90 homes that are representative of the subdivisions in Fuquay-Varina in accordance with 15A NCAC 2H .0219(1)(3). Based on the information submitted, the Division hereby approves the use of 75 GPD per bedroom per dwelling for residential units (225 GPD per three bedroom home) in all applicable non -discharge permit applications for future sewer line extensions and present, but not yet tributary projects for the Town of Fuquay- Varina. The Division did note that the average flow per residence in February 2000 was 271 GPD. Regardless of the adiusted desien daiiv wastewater flow rate. at no time shall the wastewater flows exceed the effluent limits defined in the Town's NPDES nermit for the treatment facility or exceed the ca acity of the sewers downstream of any new sewer extension Please submit a separate letter to the Raleigh Regional Office that requests flow reductions for specific previously permitted projects (indicate permit number, Project name, ermitted flow, new flow we under reduction and the difference beten them). If you have any questions or comments regarding this matter, please contact Marie Doklovic at (919)733-5083 ext. 371. S ince , L' Gregory J. Thorpe, Ph.D. cc: Raleigh Regional Office Flow Reduction File 1617 Mail Service Center. Raleigh, North Carolina 27699-1617 Telephone 9 19-733-5083 Fax 919-715 6048 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper Io WithersRavenel .. Our People. Your Success. March 26, 2021 NC DEQ 1628 Mail Service Center Raleigh, NC 27699-1628 RE: South Lakes SF-8 Sewer Permit Dear Sir or Madam: This letter is to serve as a request to permit the collection system of a residential development in Fuquay- Varina in Wake County. The proposed development consists of 65 single family homes in the South Lakes development located at the intersection of Old Honeycutt Road and Kennebec Road in Fuquay-Varina, NC. Approximately 2,628 LF of 8-inch PVC sanitary sewer lines that will tie into the downstream collection system already permitted in WQ0039812. The proposed flow is 17,063 gpd and is 300 gpd for 3.5 bedroom (75gpd/br) based on the Town's standards. Attached please find the application with fee, an original and a copy of the FTA04-16, FTSE 04-16, and site maps for your review and approval. If you have any questions or need any additional information, please feel free to contact me at 919-469-3340. Sincerely WithersRavenel Debra Ferm Project Manager 115 MacKenan Drive I Cary, NC 27511 t: 919.469.33401 f: 919.467.6008 www.withersravenel.com I License No. C-0832 Cary I Greensboro Pittsboro I Raleigh I Wilmington ::WfthersRavenel Our Peop(e. Your Success 115 Mackenan Drive Cary NC 27511 I n* z%rda7Yi1 3800 Barrett Drive Raleigh, NC WE ARE SENDING YOU Letter of Transmittal •� NCDEQ South Lakes SF-8 - Sewer Anolication THE FOLLOWING ITEMS: ®Documents ❑Plans ❑CD ❑Flash Drive OCheck No. 1 Cover Letter C� 1 Submittal Packet: FTSE 10-18, FTSA 04-16, flow reduction letter o4 Ay 1 Watershed Classification 1 USGS map L�` Q. 1 $480 check aC 4G 1 Aerial Map c, THESE ARE TRANSMITTED as checked below: ®For approval ❑Far your use ❑As requested ❑For review and comment ❑Other REMARKS: COPY TO: _ SUBMITTED BY: QA/QC REVIEWER: If enclosures are not as noted, kindly notify us upon receipt.