Loading...
HomeMy WebLinkAboutWQ0031857_Compliance Evaluation Inspection_20210427DocuSign Envelope ID: 895B6506-7918-4030-89A4-B4CC7353DF58 ROY COOPER Governor DIONNE DELLI-GATTI Secretary S. DANIEL SMITH NORTH CAROLINA Director Environmental Quality April 27, 2021 Mark Moore Town of Oak Island 4601 E Oak Is Dr Oak Island, NC 28465-7608 SUBJECT: Compliance Inspection Report Oak Island Satellite WRF Non -discharge Permit No. WQ0031857 Brunswick County Dear Mr. Moore: The North Carolina Division of Water Resources conducted an inspection of the Oak Island Satellite WRF on 4/22/2021. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0031857. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and the facility was found to be in compliance with the permit. If you should have any questions, please do not hesitate to contact Megan Faulkner with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at megan.faulkner@ncdenr.gov. Sincerely, E DocuSigned by: W►�((a S. 64 E3ABA14ACIDC414... Morelia Sanchez -King, Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Wilmington Regional Office - Enforcement File o`Oan1e1 EnYiD ��� North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 1127 Cardinal Drive Extension I Wilmington, North Carolina 28405 910.796.7215 DocuSign Envelope ID: 895B6506-7918-4030-89A4-B4CC7353DF58 Compliance Inspection Report Permit: WQ0031857 Effective: 08/16/17 Expiration: 07/31/22 Owner: Town of Oak Island SOC: Effective: Expiration: Facility: Oak Island Satellite WRF County: Brunswick 5209 E Yacht Dr Region: Wilmington Oak Island NC 28465 Contact Person: Mark Moore Title: Wastewaster Superintendent Phone: 910-201-8023 Directions to Facility: Enter onto Oak Island on SH 133. Turn right (west) on Oak Island Dr. Take Oak Island Dr west to 54th St. Turn right (north) on 54th St. WWTP is at corner of 54th St and Yacht Dr. System Classifications: WW2, Primary ORC: Bobby S. Poarch Certification: 12971 Phone: 910-457-4722 Secondary ORC(s): On -Site Representative(s): Related Permits: WQ0023693 Brunswick County - West Brunswick Regional WRF Inspection Date: 04/22/2021 Entry Time 10:OOAM Exit Time: 11:30AM Primary Inspector: Megan D Faulkne by4/27/2021 Phone: 910-796-7245 Secondary Inspector(s): CD—Signed ,669BAD1gE364 �b Uocu Igoe v 4/28/2021 Helen I Perez Er` r� 1D645B4A39694BE... Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Reclaimed Water Facility Status: Compliant ❑ Not Compliant Question Areas: Treatment Flow Measurement -Effluent Treatment Flow Measurement -Water Use Records Treatment Filters Treatment Disinfection Treatment Return pumps (See attachment summary) Treatment Flow Measurement -Influent Miscellaneous Questions Treatment Treatment Barscreen Record Keeping End Use -Infiltration End Use -Reuse Treatment Activated Sludge Treatment Flow Measurement Standby Power Page 1 of 7 DocuSign Envelope ID: 895B6506-7918-4030-89A4-B4CC7353DF58 Permit: WQ0031857 Owner - Facility: Town of Oak Island Inspection Date: 04/22/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Megan Faulkner and Helen Perez from NCDEQ DWR performed a compliance inspection on April 22, 2021. They met with Bobby Poarch, the ORC, on site. The ORC was able to provide all records requested and explained how the system operates. After reviewing records and all components of the system, it was determined that is is compliant with the permit. Infiltration is working well for this system now, and they have not needed to utilize the Oak Island Recreational Fields yet. They had to remove grass clippings/vegetation recently from the infiltration basins. Maps were available of all GW MW on the golf course. Page 2 of 7 DocuSign Envelope ID: 895B6506-7918-4030-89A4-B4CC7353DF58 Permit: WQ0031857 Owner - Facility: Town of Oak Island Inspection Date: 04/22/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Activated Sludge Spray, LR ❑ Single Family Spray, LR ❑ Lagoon Spray, LR ❑ Activated Sludge Drip, LR ❑ Activated Sludge Spray, HR ❑ Single Family Drip ❑ Recycle/Reuse ❑ Infiltration System Reuse (Quality) Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑ Comment: Treatment Flow Measurement -Influent Yes No NA NE Is flowmeter calibrated annually? ❑ ❑ 0 ❑ Is flowmeter operating properly? ❑ ❑ ❑ Does flowmeter monitor continuously? ❑ ❑ ❑ Does flowmeter record flow? ❑ ❑ ❑ Does flowmeter appear to monitor accurately? ❑ ❑ ❑ Comment: Treatment Flow Measurement -Water Use Records Yes No NA NE Is water use metered? ❑ ❑ ❑ Are the daily average values properly calculated? ❑ ❑ 0 ❑ Comment: Treatment Flow Measurement -Effluent Yes No NA NE Is flowmeter calibrated annually? ❑ ❑ ❑ Is flowmeter operating properly? ❑ ❑ ❑ Does flowmeter monitor continuously? ❑ ❑ ❑ Does flowmeter record flow? ❑ ❑ ❑ Does flowmeter appear to monitor accurately? ❑ ❑ ❑ Comment: Flowmeter calibration due in May of 2021 Standby Power Yes No NA NE Is automatically activated standby power available? ❑ 0 ❑ ❑ Page 3 of 7 DocuSign Envelope ID: 895B6506-7918-4030-89A4-B4CC7353DF58 Permit: WQ0031857 Owner - Facility: Town of Oak Island Inspection Date: 04/22/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine Is generator tested weekly by interrupting primary power source? ❑ 0 ❑ ❑ Is generator operable? 0 ❑ ❑ ❑ Does generator have adequate fuel? 0 ❑ ❑ ❑ Comment: The generator is tested weekly, but not by interrupting the primary power because of the upset it would cause to the system. The generator needs to be manually activated. Generator is servicec 2x Der vear and tested under load. Treatment Barscreen Yes No NA NE Is it free of excessive debris? ❑ ❑ ❑ Is disposal of screenings in compliance? ❑ ❑ ❑ Are the bars spaced properly? ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Rotary screen 0.2mm small Treatment Activated Sludge Yes No NA NE Is the aeration mechanism operable? ❑ ❑ ❑ Is the aeration basin thoroughly mixed? ❑ ❑ ❑ Is the aeration equipment easily accessed? ❑ ❑ ❑ Is Dissolved Oxygen adequate? ❑ ❑ ❑ Are Settleometer results acceptable? ❑ ❑ ❑ Is activated sludge an acceptable color? ❑ ❑ ❑ Comment: Treatment Return pumps Yes No NA NE Are they in place? 0 ❑ ❑ ❑ Are they operational? 0 ❑ ❑ ❑ Comment: RAS is pumped back into the anoxic chamber. Sludge is wasted to West Brunswick WWTF Treatment Filters Yes No NA NE Is the filter media present? ❑ ❑ ❑ Is the filter media the correct size and type? ❑ ❑ ❑ Is the air scour operational? 0 ❑ ❑ ❑ Is the scouring acceptable? ❑ ❑ ❑ Is the clear well free of excessive solids? ❑ ❑ ❑ Is the mud well free of excessive solids and filter media? ❑ ❑ ❑ Does backwashing frequency appear adequate? ❑ ❑ ❑ Comment: Treatment Disinfection Yes No NA NE Is the system working? 0 ❑ ❑ ❑ Page 4 of 7 DocuSign Envelope ID: 895B6506-7918-4030-89A4-B4CC7353DF58 Permit: WO0031857 Owner - Facility: Town of Oak Island Inspection Date: 04/22/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine Do the fecal coliform results indicate proper disinfection? Is there adequate detention time (>=30 minutes)? Is the system properly maintained? If gas, does the cylinder storage appear safe? Is the fan in the chlorine feed room and storage area operable? Is the chlorinator accessible? If tablets, are tablets present? Are the tablets the proper size and type? Is contact chamber free of sludge, solids, and growth? If UV, are extra UV bulbs available? If UV, is the UV intensity adequate? # Is it a dual feed system? Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1 000-- ) If yes, then when was the RMP last updated? Comment: Liquid sodium hypochlorite is used for disinfection. Finished reclaimed water sits in holding tank before being distributed. Record Keeping Yes No NA NE Is a copy of current permit available? ❑ ❑ ❑ Are monitoring reports present: NDMR? ❑ ❑ ❑ NDAR? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are application rates adhered to? ❑ ❑ ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? ❑ ❑ ❑ Are all samples analyzed for all required parameters? ❑ ❑ ❑ Are there any 2L GW quality violations? ❑ ❑ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ❑ Is effluent sampled for same parameters as GW? ❑ ❑ ❑ Do effluent concentrations exceed GW standards? ❑ ❑ ❑ Are annual soil reports available? ❑ ❑ ❑ # Are PAN records required? ❑ ❑ ❑ # Did last soil report indicate a need for lime? ❑ ❑ ❑ If so, has it been applied? ❑ ❑ ❑ Are operational logs present? ❑ ❑ ❑ Page 5 of 7 DocuSign Envelope ID: 895B6506-7918-4030-89A4-B4CC7353DF58 Permit: WQ0031857 Owner - Facility: Town of Oak Island Inspection Date: 04/22/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine Are lab sheets available for review? 0 ❑ ❑ ❑ Do lab sheets support data reported on NDMR? 0 ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? 0 ❑ ❑ ❑ Are Operational and Maintenance records present? 0 ❑ ❑ ❑ Were Operational and Maintenance records complete? 0 ❑ ❑ ❑ Has permittee been free of public complaints in last 12 months? 0 ❑ ❑ ❑ Is a copy of the SOC readily available? 0 ❑ ❑ ❑ No treatment units bypassed since last inspection? ❑ 0 ❑ ❑ Comment: Files located in office area at the facility. Operator log was complete and ORC also provided bills from cleanout. Spoke with ORC about placing pH standards in temperature controlled office aree to possibly help with calibration issues. End Use -Infiltration # Is the application High Rate or Low Rate? Yes No NA NE High Rate Are buffers maintained? ❑ ❑ ❑ Are any supply wells within the CB? ❑ ❑ ❑ Are any supply wells within 250' of the CB? ❑ ❑ ❑ Is municipal water available in the area? ❑ ❑ ❑ Are GW monitoring wells required? 0 ❑ ❑ ❑ Are GW monitoring wells located properly w/ respect to RB and CB? 0 ❑ ❑ ❑ Are GW monitoring wells properly constructed, including screened interval? ❑ ❑ ❑ Is a usable green area maintained? ❑ ❑ ❑ Is the disposal site acceptable? ❑ ❑ ❑ Is the distribution equipment acceptable? 0 ❑ ❑ ❑ Is the disposal site free of ponding? ❑ ❑ ❑ Is the disposal site free of breakout? ❑ ❑ ❑ Are the disposal sites free of solids, algae, etc.? ❑ ❑ ❑ Do the records show that the fields are properly maintained? 0 ❑ ❑ ❑ Are the disposal sites free of vegetation? ❑ ❑ ❑ Do any surface water features appear to be adversely impacted by GW discharge? ❑ ❑ ❑ No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.? ❑ ❑ ❑ Comment: End Use -Reuse Yes No NA NE Is the acreage in the permit being utilized? ❑ ❑ ❑ Does the acreage specified in the permit correspond to the measured acreage at the site? ❑ ❑ ❑ Are all essential units provided in duplicate? ❑ ❑ ❑ Is an automatically activated standby power source available? ❑ ❑ ❑ Page 6 of 7 DocuSign Envelope ID: 895B6506-7918-4030-89A4-B4CC7353DF58 Permit: WQ0031857 Owner - Facility: Town of Oak Island Inspection Date: 04/22/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine Is the equalization capacity adequate? 0 ❑ ❑ ❑ Is aerated flow equalization present? ❑ ❑ 0 ❑ Has the turbidity meter been calibrated in the last 12 months? 0 ❑ ❑ ❑ Does the turbidity meter have recording capabilities? 0 ❑ ❑ ❑ Is all flow diverted at the appropriate times? 0 ❑ ❑ ❑ Is all upset wastewater diverted from reuse storage unit? ❑ ❑ ❑ Is all upset wastewater treated, retreated, or disposed of acceptably? ❑ ❑ ❑ Is upset wastewater treated prior to discharge to irrigation storage? ❑ ❑ ❑ Is public access restricted from irrigation area during active site use? 0 ❑ ❑ ❑ If golf course, is a sign posted in plain sight on the club house? ❑ ❑ ❑ Is the cover crop acceptable? ❑ ❑ 0 ❑ Are buffers adequate? ❑ ❑ ❑ Is the site free of ponding/runoff? ❑ ❑ 0 ❑ Is the acreage in the permit being utilized? ❑ 0 ❑ ❑ Is the application equipment acceptable? ❑ ❑ ❑ Is the application area free of limiting slopes? ❑ ❑ ❑ How close is the closest water supply well? ❑ ❑ ❑ Are any supply wells within the CB? ❑ ❑ ❑ Are any supply wells within 250' of the CB? ❑ ❑ ❑ Is municipal water available in the area? 0 ❑ ❑ ❑ Are GW monitoring wells required? 0 ❑ ❑ ❑ Are GW monitoring wells located properly w/ respect to RB and CB? 0 ❑ ❑ ❑ Are GW monitoring wells properly constructed, including screened interval? ❑ ❑ ❑ Comment: All treated effluent is being disposed of in two high rate infiltration basins. The Oak Island Recreation Fields are not being used because they are not currently needed with the demand. There is no 5 day upset pond because the plant has the ability to send any upset water to the West Brunswick WWTF if needed. Upset water that occurs now is being recirculated back through the plant to be treated again. Infiltration is working well, ORC states they had to remove grass clippings/vegetation and clean out recently. Valves automatically shut off when FB gets to 11 ". ORC then has to reroute to West Brunswick WWTF. Discussed sprinklers being marked purple and whether they function at Oak Island Recreational Fields in case this area is needed it the future. It is not currently being utilized. Turbidity meter functions bV using a laser for measurements. It read 0.04 while on site. Page 7 of 7