Loading...
HomeMy WebLinkAbout20070741 Ver 2_Pre-Filing Request Review_20210503DWR Pre -Filing Meeting Request Form ID#* Regional Office* Reviewer List* 20070741 Version * 2 Asheville Regional Office - (828) 296-4500 Kaylie Yankura Pre -Filing Meeting Request submitted 5/3/2021 Contact Name * Contact Email Address* Project Name* Project Owner* Project County* Victor Lofquist, PE victor.lofquist@frontier.com Replacement of Potable Water & Sanitary Sewer Stream Crossing Mains Wade Hampton POA Jackson Owner Address: Street Address Wade Hampton POA, Inc. Address Line 2 Post Office Box 2286 aty State / Rovince / Region Cashiers NC Fbstal / Zip Code Country 28717 Jackson Is this a transportation project?* r Yes (' No Type(s) of approval sought from the DWR: fJ 401 Water Quality Certification - I— 401 Water Quality Certification - Regular Express I— Individual Permit I— Modification I— Shoreline Stabilization Does this project have an existing project ID#?* r Yes (' No Do you know the name of the staff member you would like to request a meeting with? Kaylie Yankura Please give a brief project description below and include location information. * This project is being completed to replace sections of existing sewer and water mains which are elevated crossings of an UT of Silver Run Creek (Stream Index No. 4-14-1) with subsurface stream crossing mains. The existing sections of above ground stream crossings are subject to damage and freezing. The project is located on NC Highway 107 south of the Cashiers cross roads at approximate Lat 35.08483, Long -83.06956 and is located between Jackson County NC tax parcel numbers 7581-13- 5823 and 7581-20-0657. Please give a couple of dates you are available for a meeting. 5/11/2021 5/18/2021 5/18/2021 6/3/2021 6/8/2021 Please attach the documentation you would like to have the meeting about. Fig 1-Location - Wade Hampton Utility 1.83MB Crossing.pdf Fig 2-Site Plan - Wade Hampton Utility 761.25KB Crossing.pdf Fig 3- Cross Section - Wade Hampton Utility 333.95KB Crossing.pdf pdf only By digitally signing below, I certify that I have read and understood that per the Federal Clean Water Act Section 401 Certification Rule the following statements: • This form completes the requirement of the Pre -Filing Meeting Request in the Clean Water Act Section 401 Certification Rule. • I understand by signing this form that I cannot submit my application until 30 calendar days after this pre -filing meeting request. • I also understand that DWR is not required to respond or grant the meeting request. Your project's thirty -day clock started upon receipt of this application. You will receive notification regarding meeting location and time if a meeting is necessary. You will receive notification when the thirty -day clock has expired, and you can submit an application. Signature E�r'Crt eviif' Submittal Date 5/3/2021 Reviewer Meeting Request Decision Is a meeting required or is there more info needed?* r Yes (7 No If rrore information is needed, please add comrents for the errail notification below. ,�•1.-A, ��ri�.il I� `� PRELIMINARY- DO NOT USE FOR CONSTRUCTION THIS PLAN IS NOT �� �' INTENDED TO IN ANY WAY TO REPRESENT A DETAILED CONSTRUCTION *10rirro"per , DOCUMENT AND IS INTENDED FOR USACE NATIONWIDE PERMIT SUBMITTALP. 4. ft; rac4 r -EL Art, ir Amon oft:* tuvatAk Worco44- .** atlas/ ,s bigpi rft".4 "I" 00 0114 - 10/4.,kle* re / or 'ikV rig ,01 St ®Lofquist & Associates, Inc. PLANNING ENGINEERING DESIGN 11 Citrus Drive Silva, NC 28779 (8281 586-1424 victor.daJquist##,Iimatier.cmrr Firm License # C - 2288 UPDATED 3/5/21 (2021 UT OF SILVER RUN CREEK Classification: C;Tr Classification Date: 07/01/73 Stream Index No. 4-14-1 ATITU D E: 35.08483 ONGITUDE: -83.06956 :n1 MAI WADE HAMPTON GOLF CLUB PROPOSED REPLACEMENT OF POTABLE WATER & SANITARY SEWER STREAM CROSSING MAINS PREPARED FOR: WADE HAMPTON POA, INC. JACKSON COUNTY, NORTH CAROLINA \ 0 v v s \ \ \ \ \ \ \ \ \ \ \\\ \ EXISTING FORCE MAIN TO BE WET -TAPPED AT LOW POINT WITH 2" DUCTILE IRON BODY \ TAPPING SADDLE AND 2" FULL PORT BRONZE \ BALL VALVE WITH APPROPRIATE ADAPTOR TO DRAIN FORCE MAIN BY PERMITTED SEPTAGE \ PUMP TRUCK PRIOR TO TIEING IN NEW \ SUBSURFACE FORCE MAIN SECTION. NO DISCHARGES OF SEWAGE ALLOWED. \ \\ \ \ \ \\ \ \\ \\ EXISTING WATER MAIN TO BE WET -TAPPED AT LOW POINT WITH 2" DUCTILE IRON BODY TAPPING SADDLE AND 2" FULL PORT BRONZE BALL VALVE WITH APPROPRIATE ADAPTOR TO BLOW OFF AND DRAIN WATER MAIN PRIOR TO TIEING IN NEW SUBSURFACE FORCE MAIN SECTION. NO DISCHARGES OF CHLORINATED WATER TO SI REAM OR GROUND SURFACE. USE APPROVED TABLET CHLORINATOR WI I H DIFFUSER TO UECHLORINA I E ANL) DISCHARGE Si REAM IN 1 HE AIR AWAY FROM SI REAM. \ ' '/ \ \ EXISTING DEADEND GRAVEL DRIVE TO WELL BUILDING \\ \ \ \ \\ \�@ \ \ \ \ \\ \\ \ \\ \\ \ \\ \ \\ \\ \\ \\ \ \ \ \\\\\�\ \ \ \ \\\ \ \ \ \ \ \ \ \ A V A \ \ \ \ \ \\ \ \ ''y, A • \ \ \ EXISTING SEWAGE FORCE MAIN \ \ V ABOVE GROUND STREAM CROSSING \ ,v, \VA \ \; \ , \ \\\\ \ ! `� \\\ \ \„ \ \\\ \\. \ \\ \ \ \\\ •\• A \' \\ V A\ �-0\\ I \\\\\\e,, \•�.\ 1\\\ L � \\\\/ \ \\ \ \ 1 0 T H A NOTES: 1. PRELIMINARY- DO NOT USE FOR CONSTRUCTION.THIS PLAN IS NOT INTENDED TO IN ANY WAY TO REPRESENT A DETAILED CONSTRUCTION DOCUMENT AND IS INTENDED FOR USACE NATIONWIDE PERMIT SUBMITTAL. 2. SURVEY BY JOHNSON LAND SURVEYING, INC. DWG NO. 20-038T, 9-21-20. GRID NORTH NAD 83 (2011) 2010.0000, NAVD 88 3. POST CONSTRUCTION STREAM CHANNEL MUST BE RESTORED TO PRECONSTRUCTION CONFIGURATION AND DIMENSIONS. 10 5 0 10 20 APPROXIMATE EDGES OF WATER (UT OF SILVER RUN CREEK) \ r- \ \\ \ \ \ \ Cr \ - PROPOSED 4" DUCTILE IRON PIPE, INTERNALLY RESTRAINED SUBSURFACE WATER MAIN TO REPLACE EXISTING ABOVE GROUND SECTION OF WATER MAIN STREAM CROSSING. .-McKee Development Inc. Deed Book 1726, Page 859 PIN 7581-20-0657 \\\\\ \\\ \ \\\\ 1 INCH = 10 FT PROPOSED RIP RAP SCOUR PROTECTION ON BOTH STREAM CHANNEL BANKS. TO BE KEYED INTO EXISTING GRADE TO MATCH EXISTING CHANNEL DIMENSIONS AND CONFIGURATION. SEE SECTION VIEW. EXISTING 4" PVC AND DUCTILE IRON ABOVE GROUND PORTION OF SANITARY SEWER FORCE MAIN TO BE REPLACED. 410 \ \ \ \ \`\\\ \ \ \. \ \ \\� �\ \ / FMB PROPOSED 4" DUCTILE IRON PIPE, INTERNALLY RESTRAINED SUBSURFACE FORCE MAIN TO REPLACE EXISTING ABOVE GROUND SECTION OF FORCE MAIN STREAM CROSSING. Mo Mo MO McKee Development In Deed Book 1879, Page 291 Plat Cab. 5, Slide 590 PIN -. "-13-5823 PL- \ McKee Development Inc. Deed Book 2183, Page 871 Plat Cab. 18, Slide 350 7581-30-1692 \ EXISTING 4" DUCTILE IRON ABOVE GROUND PORTION OF WATER \ MAIN TO BE REPLACED. \�`�\\ \ \ \\ \ . \ EXISTING WATER MAIN ABOVE GROUND STREAM CROSSING ®Lofquist & Associates, Inc. PLANNING ENGINEERING DESIGN 11 Citrus Drive Sjdva, NC 28779 (8281 586-1424 victor.daJquist##,Iimatier.cmrr Firm License # C - 2288 UPDATED 3/5/21 02021 PROJECT SITE PLAN WADE HAMPTON GOLF CLUB PROPOSED REPLACEMENT OF POTABLE WATER & SANITARY SEWER STREAM CROSSING MAINS PREPARED FOR: WADE HAMPTON POA, INC. JACKSON COUNTY, NORTH CAROLINA FIGURE NUMBER 2 of 3 NOTES: 1. PRELIMINARY- DO NOT USE FOR CONSTRUCTION.THIS PLAN IS NOT INTENDED TO IN ANY WAY TO REPRESENT A DETAILED CONSTRUCTION DOCUMENT AND IS INTENDED FOR USACE NATIONWIDE PERMIT SUBMITTAL. 2. POST CONSTRUCTION STREAM CHANNEL MUST BE RESTORED TO PRECONSTRUCTION CONFIGURATION AND DIMENSIONS. PROPOSED 4" DIA. INTERNALLY RESTRAINED CL. 51 DUCTILE IRON PIPE SUBSURFACE STREAM CROSSINGS TO REPLACE EXISTING ABOVE GROUND WATER MAIN AND SEWAGE FORCE MAIN STREAM CROSSINGS MIN. 24" THICK, NCDOT CL. 1 CLEAN RIP -RAP z 1 USE FULL LENGTH 20 FT SECTIONS OF 4" DIP TO MINIMIZE THE NEED FOR IN LINE JOINTS IN STRAIGHT SECTIONS OF PIPING. WHERE REQUIRED, IN LINE JOINTS ARE TO HAVE INTERNALLY RESTRAINED GASKET SYSTEM. INSTALL RIPRAP ON FILTER FABRIC, MIRAFI 140N OR APPROVED EQUAL NOTES: KEY RIP -RAP INTO SLOPE AND STREAM BED, RESTORING STREAM CHANNEL TO PRECONSTRUCTION ELEVATIONS, GRADES AND GEOMETRY. TYPICAL. NORMAL CREEK WATER LEVEL v NO JOINTS ALLOWED IN 4" DIP SECTION UNDER STREAM BED AND FOR A MINIMUM OF 2 FT BEYOND THE EDGE OF WATER ON BOTH SIDES OF STREAM. BACKFILL TRENCH WITH NATURAL STREAMBED MATERIALS REMOVED FROM STREAMBED (COBBLES, GRAVELS & SANDS) FOR PIPE INSTALLATION NATURAL CREEK BED x x x INTERNALLY RESTRAINED — MECHANICAL JOINT COUPLING AND FITTINGS AT CONNECTIONS TO EXISTING PIPING. PROVIDE INTERNALLY RESTRAINED BENDS, FITTINGS & JOINTS AS REQUIRED PER PLAN AND AS NEEDED FOR SITE SPECIFIC CONDITIONS PROPOSED 4" DIP SUBSURFACE STREAM CROSSING PIPING TO REPLACE EXISTING ABOVE GROUND WATER MAIN AND SEWAGE FORCE MAIN STREAM CROSSINGS 1. CREEK CROSSING UTILITY INSTALLATIONS SHALL BE IN ACCORDANCE WITH REGULATORY REQUIREMENTS FOR A SITE SPECIFIC INSTALLATION. 2. INSTALL PROPERLY SIZED TEMPORARY HDPE CULVERT IN STREAM (CENTERED ON PROPOSED UTILITY CREEK CROSSING) AND COMPLETELY DIVERT STREAMFLOW THROUGH CULVERT USING TEMPORARY SAND BAGS. EXCAVATE BENEATH THE TEMPORARY CULVERT AND INSTALL THE UTILITY AT THE PROPER DEPTH BELOW THE TEMPORARY CULVERT AT THE PROPER DEPTH. BACKFILL THE STREAM BED PORTION OF THE UTILITY TRENCH WITH CLEAN, NATURAL STREAM BED MATERIALS CONSISTING OF COBBLES, FINE GRAVELS AND SANDS FREE FROM ORGANIC MATERIALS. USE A TEMPORARY HDPE CULVERT AND SANDBAGS TO DIVERT STREAM FLOW TO COMPLETE RIP RAP SLOPE PROTECTION ON BOTH STREAMBANKS AS SHOWN ON PLAN, KEYING INTO NATURAL GRADE. THE TEMPORARY CULVERT AND SANDBAGS MUST BE REMOVED AT THE END OF EACH WORK DAY AND UNDER THE THREAT OF RAIN EVENTS AS NEEDED TO PREVENT IMPACT THE FLOOD HEIGHTS AND AS NEEDED TO PREVENT EROSION DAMAGE. UPON COMPLETION OF ALL PIPE INSTALLATION, COMPLETELY REMOVE THE TEMPORARY CULVERT AND SAND BAGS AND RESTORE THE STREAM CHANNEL TO PRECONSTRUCTION DIMENSIONS AND CROSS SECTIONS. WATER MAIN OR SEWAGE FORCE MAIN REPLACEMENT STREAM CROSSING SECTION NOT TO SCALE Lofquist & Associates, Inc. PLANNING ENGINEERING DESIGN 11 Citrus Drive Sjdva, NC 28779 (8281 586-1424 victor.daJquist##,Iimatier.cmrr Fir"t License # C - 2288 UPDATED 3/5/21 02021 TYPICAL REPLACEMENT SUBSURFACE PIPE INSTALLATION CROSS SECTION WADE HAMPTON GOLF CLUB PROPOSED REPLACEMENT OF POTABLE WATER & SANITARY SEWER STREAM CROSSING MAINS PREPARED FOR: WADE HAMPTON POA, INC. JACKSON COUNTY, NORTH CAROLINA FIGURE NUMBER 3 of 3