HomeMy WebLinkAboutWQ0032019_Regional Office Historical File Pre 2018Michael F. Easley, Crowfoot - 'William G. Ross fr., Secretary North Carolina Department of Environment arid Natural Resources Coleen H. Sullins, Director Division or Water Quality July 31, 2007 Mr. Mick Berry, City Manager City of Hickory PO Box 398 Hickory, NC 28603 Subject: Permit No. W00032019 21st Street Lane Sewer Extension Wastewater Collection System Extension Catawba County, North Carolina Dear Mr, Berry, In accordance with your application received on July 19, 2007, we are forwarding herewith Permit No, WQ0032019, dated July 31, 2007, to the City of Hickory for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This corer letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T ,0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T, 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein, Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215,6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Nlooresville Regional Office 61.()1ast Center Aye,„ Suite. 3(l1 Mooresville, NC 281 Internet www.nornwaterquality„org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmatve Action Employer - 50% Recycled/10% Post Consumer Paper Phone., (704) 663-1.699 Fax, (704) 663-6040 Onc ithCaraliria 7aturally Mr, Berry Page 2 Ally 31, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Hickory for the construction and operation of approximately 622 linear feet of 8- inch gravity sewer and the discharge of 0 gallons per day of collected domestic wastewater into the City of Hickory existing sewerage system, pursuant to the application received July 19, 2007, and in conformity with 15A NCAC 2T, the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources arid considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Hickory VWVTP (NPDES No. NC0020401) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning his matter, please contact Dee Browder at (704) 663-1699. Sincerely, /2f tor Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit File Jeff McCluskey, Mc@ Engineering, Inc. Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1, This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data, 3 The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L 0200 or the surface water standards in 15A NCAC 2B .0200, b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year), Pump stations that are connected to a telemetry system shall be inspected at least once per week, e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 28 .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable., In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved, 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6, Per 15A NCAC 2T ,0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form, A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities, 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T, the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215,6C 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H ,0500, 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc., or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice marl messages or faxed information is permissible, but shall not be considered as he initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) - 3 8 or ( 1 ) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form S- (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part l of Form -S (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 31stday of July, 2007, NORTH CAROLINA ENVIRONMENTAL ANAGEMENT COCOMMISSION fax Coleen I"-1. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commr tis on t NuNumber WQ0032019 Fast Track Engineering Certification Permit No. WQ0032019 Jury 31, 2007 OwnerPvVQCSNWVTP Mick Berry, City Manager Hickory, NC 28603 PO Box 398 Hickory, NC 28603 PE Jeff McCluskey Mc2 Engineering, Inc. 2110 Ben Craig Drive, S te 400 Charlotte, NC 28262 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater coUection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. I I ENGINEER'S CERTIFICATION Partial Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (LI periodically, El weekly, LI full time) the construction of 21st Street Lane Sewer Extension, a Catawba County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking ail partial certifications up until a final certification is received; Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 0 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) Owner, la, City of Hickory Full Legal Name (company, municipality, HOA, utility, etc.) b. Mick W. Berry, City Manager -Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) lc. The legal entity who will own this system is: 0 Individual 0 Federal Municipality 0 State/County 0 Private Partnership 0 Corporation 0 Other (specify) ld. PO Box 398 le. Hickory Mailing Address City if NC ig. 28603 State Zip Code 1h k_828) 323-7427 1i KN8) 322-1405 Telephone Facsimile O 2 Project (Facility) Information 2a 21st Street Lane Sewer Extension 0- Brief Project Name (pemiit wth refer to thisname) County Where Project is Located eg 3 Contact Person: 3a JeffMcCluskey - Project Civil Engineer 1j. E-mail 2b, Catawba z Name and Affiliation of Someone Who Can Answer Questions About this A plication 3b. (7041510-9797 3c, Je c2eng.corn Phone Number E-mail 1 Project is E New 0 Modification (of an existing permit) If Modification, Permit No,: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le, adding another phase, changing line sizeilength, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2, Owner is 1 Public (skip to Item 8(3)) 0 Private (go to item 2(a)) 2a. If private, applicant will be: 0 Retaining Ownership (i,e, store, church, single office, etc) or 0 Leasing units (lots, townhomes, etc, - skip to Item 8(3)) 0 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) 3 City of Hickory Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a, City of Hickory,Henry Fork WWTP 4b. NC0040797 o Name ofWWTF WWTF Permit No LL 5a. City of Hickory Utility 5b 8" Gravity Z Owner of Downstream Sewer Receiving Sewer Size 0 Force Main -- 6 The origin of this wastewater is (check all that apply): 2b. If sold, facilities owned by a (must choose one) 0 Public Utility (Instruction III) 0 Homeowner Assoc./Developer (Instruction IV) ni 0 Residential Subdivision 0 Apartments/Condominiums 0 Mobile Home Park 0 School Restaurant 0 Office Permit Number of Downstream Sewer (if known El Car Wash 0 Institution 0 Hospital 0 Church 0 Nursing Home Other (specify). Commercial/Retail 100 % Domestic/Commercial % Industrial % Other (specify): 7, Volume of wastewater to be allocated for this particular project: 0 (Ex, Pump station to be Abandoned) gallons per day *Do not include previously permitted allocations 8, If the permitted flow is zero, indicate why: Interceptor Line - Flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. Rehabilitation or replacement of existing sewer with no new flow expected (Same o only vs, PTA )2/03 - Rev. 3 04105 APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PACE 4 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(t)(3). 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8°" 621.94 ENTER TOTAL LINE LENGTH IN MILES 0.1178 0 11, Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Gravity or Force Main (use the pull down menu) Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator MATS; 3- plans for cross-reference) (MGD) GPM @ TDH portable generator witelemetry; 4-wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force. Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable'? Yes 0 No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits certifications been submitted for approval WetlandfStream Crossings - General Permit or 401 Certification? ❑ Yes © No El N/A Sedimentation and Erosion Control Plan? © Yes 0 No N/A Stormwater? 0 Yes LI No Z NIA 14. Does this project involve aerial lines or siphons? Check if yes. LI These lines will be considered hoah onority and must be checked once every six mnonths 15. Does this project have gravity sewer lines designed at minimum slopes? [_.] Be aware that the Division will not accept installed lines more than 1 O% flatter than the minimum slope. Lines installed outside thi corrected prior to submitting the final engineering certification.. erance should be ETA (12/0 a - Rev. 3 04/05 APPLICATION for GRAVITY SEWERS, P1 P STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS) to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: Z A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope 17— water -body; AND, El A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody, 2 0 Location ID on Map (self chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification Submit the 8.5°' x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicants Certification: Mick W Berry, attest that this application for 21st Street Lane Sewer Extension has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete, Note: In accordance with North Carolina Genera/ Statutes 143-215.6A and 143-215. 6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation. la Professional Engineer's Certification Date I Jeffrey D. McCluskey, attest that this application for 21st Street Lane Sewer Extension has been reviewed by me and is accurate, complete and consistent with the information in the engineenng plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Jeffrey D. McCluskey, PE Professional Engineer Name 2b. Mc2 Eligneeringr Inc, Engineering Firm 2c. 2110 Ben Craig Dr,, Suite 400 Mailing Address 2d. Charlotte City 2e NC 2f 28262 State Zip 2g. 704.510.9797 2h, 704.510.9787 2i, Jeffarpc2eng,com Telephone Facsimile E-mail Seal, Signature & Date 1TA 02/03 - Rev. 3 04/05 Permit Number WQ0032019 Cerdrai Fiiesi APS SWF_ 07/30/07 Permit Tracking SIM Program Category Non -discharge Permit Type Fasf, Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dee browder Permitted Flow 0 facility Facility Name 21st Street Lane Sewer Extension Location Address Pwner Status Project Type In review New Project Version Permit Classification A Individual Permit Contact Affiliation tiAajoriMinor Region Minor Mooresville County Catawba Facility Contact Affiliation Owner Nagle Owner Type City of Hickory Government - Municipal Pates/Events Owner Affiliation Mick Berry PO Box 398 Hickory Orig issue Agri Received Draft Initiated 07/31/07 07/19/07 Scheduled Issuance NC 286010398 Public Notice issue Effective Expiration 07/31/07 07/31/07 Renalated Activities Reauesteclifttelyed Events Office Resteurani Retail kNastesdater collection Outlet! NUL1 Addleor)al information receded Aceiftional informaeon requested Waterbody Name Stream index Number Current Class Subbasin IHE2b9"' OE1-1O2,02:F "2000E50:' aq,E202t.,� 141