Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0031695_Regional Office Historical File Pre 2018
Michael F. Easley, Governor William G. Rossir,, Secretary North Carolina Department of Environmera and Natural Resources Alan W. Klimek, P_E. Director Division of Water Quality May 9, 2007 Mr. Mick Berry, City Manager City of Hickory RO, Box 398 Hickory, North Carolina 28603 Subject: Permit No. WQ0031695 City of Hickory Carolina Business Park Wastewater Collection System Extension Catawba County, North Carolina Dear Mr Berry: In accordance with your application received on May 3, 2007, we are forwarding herewith Permit No. WQ0031695, dated May 9, 2007, to the City of Hickory for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein, This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference, Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T, 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein, Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, Mooresville Regional Office 610 East Center Avenue, Suite 30'1, Mooresville, NC 28115 Phone: 704-663-1699 Fax: 704-663-6040 / Internet: http'Ith2o,enrstate,nc,us ne NoOrthCarolina Naturally An Equal OpportunitylAffirmative Action Employer —50% Recycled/10%© Post Consumer Paper Mick Berry Page 2 May 9, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Hickory for the construction and operation of approximately 146 linear feet of 8- inch gravity sewer to serve 12 employees as part of the Carolina Business Park project; and the discharge of 450 gallons per day of collected domestic wastewater into the City of Hickory's existing sewerage system, pursuant to the application received May 3, 2007, and in conformity with 15A NCAC 2-1; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable: and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Hickory Henry Fork WWIP (NPDES No. NC0040797) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit, This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Basinger at (704) 663-1699. Sincerely, ,t- L for Alan W. Klimek, P.E. cc: Mooresville Regional Office, Surface Water Protection (Fast Track Sewer Ext Files) G. Cecil Clark, RE., Clark & Associates, Inc. Surface Water Protection Central Files PERCS Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1, This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable: and other supporting materials unless specifically mentioned herein, 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data, The wastewater collection facilities shall be properly maintained and operated at all times The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T ,0403, If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B ,0200 b. A map of the sewer system shall be developed and shall be actively maintained, c. An operation and maintenance plan shall be developed and implemented, d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e, 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B ,0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5 Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6, Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities, 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500, 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office. telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. !Fir Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control, 12. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is a unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation, This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case by case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. Permit issued this the 9th day of May, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION (9) for Alan Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0031695 r • Fast Track Engineering Certification Permit No, WQ0031695 May 9, 2007 Mick Berry, City Manager City of Hickory PO Box 398 Hickory, NC 28603 G. Cecil Clark, P.E. Clark & Associates, Inc. PO Box 2945 Hickory, NC 28603 Complete and submit this form to the permit issuing regional office with the 'following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected purnps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification, and all required supporting documentation, have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial E] Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (El periodically, Ej weekly, El full time) the construction of the Carolina Business Park, Catawba County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NORTH CAROLINA 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELDt Application Number: (to be completed by DWQ) ; 1. Owner 1a. City of Hickory Full Legal Name (company, municipality, HOA, utility, etc.) 0 lb MBCIt2aer Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) The legal entity who will own this system is: Individual 0 Federal Ii Municipality 0 State/County 0 Private Partnership, 0 Corporation 0 Other (specify): 1d. PO Box 398 Mailing Address 1f NC State 11 h. 828 323-7427 1 i. 828 323-740 Telephone Faesimile 12. Project (Facility) Information: 2a, Carolina Business Park le. Hickory City 1g. 28603 Zip Code lj kgreer@ci.hickory.nc.us E-mail 2b. Catawba Brief Project Name (pemfit will refer to this name)County Where Project is Located Contact Person: 3a. Cecil Clark P.E. Engineer for the Pro'ect i Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 828 345-1577 3c. 828 345-0271 Phone Number E-mail 1. Project is New 0 Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line sizeilength, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(1O-11) that has already been included in the original permit. 2. Owner is Public (skip to item B(3)) El Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) 0 Retaining Ownership (Le. store, church, single office, etc.) or 0 Public Utility (Instruction III) Z 0 Leasing units (lots, townhornes, etc. - skip to Item 8(3)) 0 Homeowner Assoc./Developer (Instruction IV) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. City of Hickory Owner of Wastewater Treatment Facility (WVVTF) Treating Wastewater From This Project 4a. Henry Fork Waste Water Treatment Plant 4b, NC 0040797 Name of WWTF ! WVVTF Permit No, 5a. City of Hickory j5b. 8 X Gravity . NC 0040797 Z Owner of Downstream Sewer Receiving Sewer Size p Force Main 1 Permit Number of Downstream Sewer (if known) 6. The origin of this wastewater is (check all that apply) 0 Residential Subdivision 0 Apartments/Condominiums Mobile Home Park 0 School Restaurant Office El Car Wash 0 Institution 0 Hospital 0 Church 0 Nursing Home 0 Other (specify): 7. Volume of wastewater to be allocated for this particular project: 450 gallons per day 8. *Do not include previously permitted allocations 100 % Domestic/Commercial % Industrial % Other (specify): If the permitted flow is zero, indicate why: E:1 Interceptor Line - Flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Perrnit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 - Rev. 3 .04/0.5 APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 CO 9 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(1)(3). Office — 12 employees @ 25 gpd/person = 300 gpdi shift + VA shift = 450 gal /day 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main (use the pull down menu 8 146 gravity ENTER TOTAL LINE LENGTH IN MILES! .027 . Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID . . Power Reliability Option (self chosen - as shown on Design Flow 1 Operational Point 1 (1- dual line feed; 2- permanent generator w/ATS; 3- I. plans for cross-reference) jmGp) i GPM @ TDH 1 portable generator w/telemetry; 4-wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? Yes D No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13, Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? LI Yes E] No N/A Sedimentation and Erosion Control Plan? Stormwater? 14. Does this project involve aerial lines or siphons? Check if yes: hese lines will tteconsidereaPiaLorioritt ani3 must tke,avecimcl_onme_v_esy. siximonttis_ 15. Does this project have gravity sewer lines designed at minimum slopes? El Be aware that the Division will not accept installed lines more than 10% flatter than the minimum slope Lines installed outside this tolerance should be corrected prior to submitting the final engineering certification Yes DNo X N/A Yes EJNo N/A ETA 02/03 - Rev. 3 04/05 APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as1 necessary) This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on Name of map for cross-reference) Waterbody el '3 Waterbody Stream Waterbody County River Basin Index Classification Submit the 8.5°' x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: /, Mick W. Berry, attest That this application for Carolina Business Path Sewer Extension has been reviewed by me a is accurate and complete to the best of my knowledge, I understand that if all required parts of this application am not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete, Note: In accordance with North Carolina General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. SifIiag 0fficia Signatui 2, Professional Engineer's Certification. Date attest that this application for Carolina Business Park Sewer Extension has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted Febroary 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these ,materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215,6B, any person who knowingly makes any false statement representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation 2a, G. Cecil Clark Professional Engineer Name 2b, Clark & Associates, Inc. Engineering Firm 2c. PO Box 2945 Mailing Address 2d, Hickory City 2g, 828 345-1577 2h, 828 345-0271 e, NC _2f, 28603 State Zip Telephone Facsimile clarkengineeringr; charterinter ruat nrArn Seal, Signature a Date FTA 02/03 - Rev, 3 04, ; srx..r r., :k a e/ r.m,01,+ar Central Files: APS SWP f15/07/07 Perrnit Number 131 695 Category har ° Permit Tracking IIp Status In review Project Type New Project Permit Type r t Version Permit Classification Gravity Sewer Extensions Pump Stations, Pressure Sewer A Individual Extensions Primary Reviewer sonj.basiner' Permitted Flow 450 Fac ty Facility Name Carolina Business Park Location Address ,Owner Owner Name City of Hickory Dates/Events Permit Contact Affiliation inor Region Mooresville County Catawba Faculty Contact Affiliation Orig issue App Received Draft Initiated 05/03/07 Regulated tivitiies Commercial or industrial, other Wastewater collection OLitiail NLIL.L Waterbody Name Scheduled Issuance Public Owner Type Government -'Municipal Owner Afflhiatidn Mick Berry PO Box Hickory NC 286010398 ice Issue Effecti Requested/Received Events Additional information received Additio & information equested St r :ant Index Number Expiration Current Class Subbasin PAY TO THE ORDER GREGORY A KIZIAH P 0 BOX 37 TAYLORVILLE, NC 28681 PH 828-632 O 995 813AT BRANCH BANKING AND TRUST COMPANY 1 -BOG-BANK B8T SEITcom Four Hundred and 0 /100 Dollars DENR A I „711 071- 0001566e 1:053101 211:000529570 SEI 2111 1566 65-1121531 DATE Apr 2'7, 200 AMOUNT • 4$4 00 00 -on Michael F. Easley, Governor William G. Ross Jr.. Secretary North Carolina Department of Environment and Natural Resources Coleen Sullins, Director Division of Water Quality January 22, 2008 Mick Berry, City Manager City of Hickory P.O, Box 398 Hickory, North Carolina 28603 SUBJECT: Carolina Business Park Permit No. WQ0031695 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for the subject project on September 26, 2007. A full review of the certification materials may or may not be conducted, It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a copy. You are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this, permit is not automatically transferable. Form PNOCF-S can be downloaded from htto://h2o.enr,state.nc.us/ndpuindouapps.htmlffSewer, if you have any questions concerning this document or the completion of Form PNCCF-S (if necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee,browder@ncmail.net, obert Krebs urface Water Protection Regional Supervisor Enclosure Cc: G. Cecil Clark, Clark & Associates, FT-. Surface Water Protection Section Central Files (certcaijon page only) One NorthCarohna laturally Pretreatment, Emergency Response and Collection Systems Unit Internet http://h2o.eninc.state.uslnripti 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer Telephone (919) 733-5083 Fax (919) 733-0059 50% recycled/10%, post -consumer paper Fast Track Engineering Certification Permit No. WQ0031695 May 9, 2007 Mick Berry, City Manager City of Hickory PO Box 398 Hickory, NC 28603 G Cecil Clark, PE, Clark & Associates, Inc. PO Box 2945 Hickory, NC 28603 DWQ-Sur ace Water Pro_ Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected purnps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineers Certification, and all required supporting documentation, have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial [n Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (J periodically, [I] weekly, El full time) the construction of the Carolina Business Park, Catawba County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit: 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. I, G. Cecil Clark SEP 2 6 20(17 NC DENR MRO North Carolina Professional Engineer's seal, signature, and date: iESs,G 8E4L fl 5156 11,,01‘ Oh L SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NORTH CAROLINA 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions