Loading...
HomeMy WebLinkAboutWQ0030735_Regional Office Historical File Pre 2018Michael F. Easley, Governor William G. Ross Jr,, Secretary North Carolina Department of Environment and Natural Resources Alan W, Klirnek, P.E, Director Division of Water Quality August 31, 2006 Mr. Mick W, Berry, City Manager City of Hickory P.O. Box 398 Hickory, North Carolina 28601 Subject: Permit No, WQ0030735 Viewmont Phase III City of Hickory Wastewater Collection System Extension Catawba County, North Carolina Dear Mr. Berry: In accordance with your application received on August 25, 2006, we are forwarding herewith Permit No. WQ0030735, dated August 31, 2006, to the City of Hickory for the construction and operation of the subject wastewater collection system. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference, Please pay particular attention to Permit Condition 3, which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein, Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215,6A through §143-215,6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Internet wv.w.ncwaterquality.org Customer Service7 1-877-623-6748 An Equal OpIxtrtdnity/Affirrnalive Action Employer — 50% Recycled/10% Post Consumer Paper Phone, (704) 663-1699 Fax (704) 663-6040 NorthCaroljna ,NaturizIly Mr. Mick W. Berry Page 2 August 31, 2006 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Aqua North Carolina for the construction and operation of approximately 358 linear feet of 8-inch gravity sewer as part of the Viewmont Phase III project, and the discharge of 5,216 gallons per day of collected domestic wastewater into the City of Hickory existing sewerage system, pursuant to the application received August 25, 2006, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Hickory WWTP (Northeast WWTP NPDES No. NC0020401) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1508 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Marcia Allocco at (704) 663-1699. Sincerely, r Alan W. Klimek, P.E. cc: Mooresville Regional Office, Surface Water Protection (WWTP Permit No. NC0020401) Doug Chapman, McGill Associates, PA Surface Water Protection Central Files Mina Leach, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 21...0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week, e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc,; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility, Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur, Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 31st day of August, 2006, NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klime P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0030735 Fast Track EngineeringCeytification City of Hickory Permit No, WQ0030735 August 31, 2006 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION 0 Partial 0 Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (0 periodically, 0 weekly, 0 full time) the construction of the Viewmont Phase III, a Catawba County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H ,0200: the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable: and other supporting materials, North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. T-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 z 0 Ce 1d. 0 Z f, 0 0 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) 1. Owner. 1 a City of Hickory Full Legal Name (company, municipality, HOA, utility, etc.) lb. Mick W. Berry, City Manager _ Signing Off cial Name and Title (Please review 15A NCAC 2H ,0206(b) for authorized signing officials!) lc, The legal entity who will own this system is: 0 Individual Federal Municipality 0 State/County 0 Private Partnership Ej Corporation 0 Other (specify): Post Office Box 398 le. Hickory Street Address NC State 1 h. 828-323-7412 Telephone 2. Project (Facility) Information: 11. 828-323-7550 City lg. 28601 Zip Code 1j, mberryeci.hickory,nc.us Facsimile E-mail 2a. Viewmont Phase III 2b. Catawba. Brief Project Name (permit will refer to this name) County Where Project is Located 3. Contact Person; 3a. Doug Chapman, P,E., Mcgill Associates, PA Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 828-328-2024 3c. dchapman@mcgillengineers.com Phone Number E-mail 1. Project is New Ej Modification (of an existing permit) If Modification, Permit No,: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc,). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is E Public (skip to Item B(3)) 0 Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) 0 Retaining Ownership (i.e. store, church, single office, etc.) or UPubrc Utility (Instruction III) E] Leasing units (lots, townhomes, etc. - skip to Item B(3)) [3Homeowner AssociDeve oper (Instruction IV) r] Selling units (lots, townhomes, etc. - go to Item B(2b)) 3.City of Hickory Owner of Wastewater Treatment Facility (VVWTF) Treating Wastewater From This Project 4a. Northeast WW-11, 4b, NC0020401 Name of WWTF VWITTF Permit No, 5a, City of Hickory 5b, 8-inch gravity 5c. Information not available Owner of Downstream Sewer Receiving Sewer Size Permit Number of Downstream Sewer (if known) 8. The origin of this wastewater is (check all that apply): Residential Subdivision 0 Apartments/Condominiums • Mobile Home Park O School Restaurant 0 Office O Car Wash 0 Institution O Hospital O Church O Nursing Home , • 21 Other (specify): '60- 7, Volume of wastewater to be permitted in this project: 5,216 gallons per day 100 % Domestic/Commercial % Industrial % Other (specify): 8. If the permitted flow is zero, indicate why: Ej Interceptor Line - Flow will be perrnitted is subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 - Rev% 2 04/04 T-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9, Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219()(1-2) must be approved prior to submittal of this application, Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(1)(3). Restaurants: 80 seats @ 40 gal/seat = 3,200 gpd Stores: 16,800 ft2/ 1,000 ft2= 16.80 x 120 gal/ 1,000 ft2= 2,016 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8-inch Gravity or Force Main (use the pull down menu) 358 Gravity ENTER TOTAL LINE LENGTH IN MILES 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID Power Reliability Option re (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3- 0 plans for cross-reference) (MGD) GPM @ TDH portable generator w(telemetry; 4-wet well storage) ni N/A 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? 114 Yes 0 No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13, Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? 0 Yes 0 No 114 N/A Sedimentation and Erosion Control Plan? Z Yes 0 No 0 N/A Stormwater? Yes ID No 0 N/A FTA 02/03 - Rev. 2 04/04 T-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 0 z 0 1 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification 1 Cripple Creek Catawba Catawba 11-54-2 WS-IV Submit the 8,5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! pplicants Certification: I, Mick W. Berry, attest that this application for Viewmont Square Phase III has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215,6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, — Signing Official Signature Professional Engineer's Certification, Date I attest that this application for Viewmont Square Phase 111 has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. / further attest that to the best of my knowledge the proposed design has been prepared in accordance with the a pplicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC General Statutes 143-215.6A and 143-215,68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a Doug Chapman, P.E. Professional Engineer Name 2b, McGill Associates, PA Engineering Firm 2e. 1236 19th Street Lane NW Address 2d, Hickory 2e, NC 2f. 28601 City State Zip 2g, 828-328-2 24 2h, 828- 28-3057 2i. dchapman©mcgillengineers,com Telephone Facsimile E-mail 20622 Seaf, nature & Date ETA 02/03 - Rey. 2 04/04 Central Files, APS SWP 08/30/06 Permit Number WQ0030735 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type t c k Version Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Extensions Primary Reviewer marciaallocco Permitted Flow 5216 Facility Permit Classification Individual Permit Contact Affiliation Facility Name Viewmont Phase Location Address Owner Owner Name City of Hickory Patesicvents °rig Issue App Received 08/25/06 Regulated Activities Commercial or industrial, other Restairranl Subdivision Wastewater collection Outfall NULL Draft Initiated Scheduled Issuance Major/Minor Region Minor Mooresville County Catawba Facility Contact Affiliation Owner Type Government - Municipal Owner Affiliation Mick Berry PO Box 398 Hickory Public Notice Issue NC 286010398 Effective Expiration EasuatediReceiyed vents Additional information received Additional information requested Waterbody Name Stream Index Number Current Class Subbasin PRISM DEVELOPMENT TRUST ACCT PO BOX 729 HICKORY, NC 28603 (828)322-6800 PAY * * * * FOUR H TO THE ORDER OF 61CDENR RED Peoples Bank Vsew►nont Office Hickory, NC 28601 66-486/531 D 00/100 DOLLARS a\X C il'QQL1?Lug 1:053L04869 DATE 08/23/06 9 31188 3 50OP DATE:Q8/23/06 CK#:1171 TOTAL:$400.00***** BANK:pdtrust - Prism Development Trust Acct. PAYEE:DENR(denr) Prop/Job/Categ!Acct Invoice Description 29/29b1ockb/20000008/1181-2902 Email Sewer application fee AMOUNT $400.00***** Amount 400.00 400.00 rke l lease tnlatresed for yot 2006 lr. lichel Pa 7Ntorthicarolina. i °i ica it carat rQua 640 Past "enter refine, Suite" 1 .MooredvalletNortir t+lira Deter R `i -w mont Squat.e Center 131c ck Pr j City of Flickorw° tatvba County., North Carolina approval ine" (1) original id one (I } opy of the st `l c°act Application for the Grascity ewwTet°s, Pump a tan ns and Force ?Plains, for the above referenced project, please also find enclosed a check its the amount of 00 to, cover the tppl crrti ate fLc. Iles the in t rl ano of approxitr ately 38 linear feet of hears Center Block Project. ect. The design of the pro prepared in acccat.cl xnce ww ilh l` iCL JC 's txlininturtit design criteria for gravity sewer rocs and stations. Ate. 99 if =cant l aw e t y dug icans or rerluire additional irife)rtraatira e feel fires to give me t all at828-328-2024. poildOt Mc011 I SOCIAl°FS P.A. ER ding this a -he `eb°5 " Apo raphic Niap Page 1 of 1 0 0.3 0.6 0.9 1.2 1.5 km 0 0.2 0.4 0,6 0.8 1 i Map center is UTM 17 469377E 3956329N (WGS84/NAD83) Bethlehem quadrangle Projection is UTM Zone 17 NAD83 Datum [_-f,J.1`1:1 niprint.asp'z,-17&n-3956329.0000952&e=469377.000000001 &s... 8/17/2006