Loading...
HomeMy WebLinkAboutWQ0024282_Regional Office Historical File Pre 2018Michael U 'Task.). Clovernor ‘Villinin G. Ross Jr.. Secretary North Carolillil Department of Env' onmeni and Natural Resources Alan W, Klimck, E. Dirccior Div is i(111 Of WIIICT Quality September 1, 2004 Mr. Lloyd Beasley, City Manager City of Conover Post Office Box 549 Conover, North Carolina 28613 Subject: Permit No. WQ0024282 City of Conover East Way Lane Sewer Extension Wastewater Collection System Extension Catawba County, North Carolina Dear Mr. Beasley: In accordance with your application received on August 16, 2004, and additional information received on September 1, 2004, we are forwarding herewith Permit No, WQ0024282, dated September 1, 2004, to the City of Conover for the construction and operation of the subject wastewater collection system extension, This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference, Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H ,0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H ,0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Rcgional Office 919 North Main Street Mooresville, NO 28.1.15 Internet h2o,enr,state.naus Customer Service: 1.-877-623-(748 An Equal Opportutty/Affirmative Action Employer — 50% Recycled110% Post ConsurnerPaper Phone: (704) 663-1699 Fax: (704) 663-6040 Cr Northearoltimi ,Vaturally Mr, Lloyd Beasley Page 2 September 1, 20D4 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Conover for the construction and operation of approximately 115.75 linear feet of 8-inch gravity sewer to serve a single family residence as part of the East Way Lane Sewer Extension project, and the discharge of 360 gallons per day of collected domestic wastewater into the City of Conover's existing sewerage system, pursuant to the application received August 16, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Newton's Clark Creek WWTP (NPDES No. NC0036196) prior to being discharged into the receiving stream. This permit shall become voidable unless the agreement between the City of Conover and the City of Newton for the collection and final treatment of wastewater is in full force and effect. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1508 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Williams at (704) 663-1699. Sincerely, ;;7) for Alan W. Klimek, P.E. cc: Catawba County Health Department Mooresville Regional Office, Water Quality Section (VVVVTF Permit No. NC0036196) R. Carroll Williams, PE Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C, 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the North Carolina Department of Environment and Natural Resources, Water Quality, 919 North Main Street, Mooresville, N.C. 28115. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500, Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a, Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permlt issued this the 1st day of September, 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. KlimFKP.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0024282 Fast F:nqineerimq Certification . Permit No. VVQOO24282 Complete and submit this form to the permit issuing regional office with the ����� ° One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point` available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted espart ofthis project � Changes tothe projectshould beclearly identified onthe record drawings or|n modifications are raquined.for anYchonqpa,eso|tinq|nnon-compliance minimum desiqncriteria. ensummary form. Permit IDit.reQu}otionmor This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received bythe Division. Therefore, itishighly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial Final |. . as a duly registered Professional Engineer in the State of North Caro|ina, having been authorized to observe (17 periodically, 7 weekly, El full time) the construction of the East Way Lane Sewer Ex1enmion, Catawba County project for the Permittee hereby state that, to the beat ofmyabilities, due :are and diligence was used in the observation of the construction such that the construction was observed tobebuilt within substantial compliance ofthis permit; 15A NCAC 2H .0200; the Division ofWater Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12. 1996 as applicable; the Division's Mmirnunn Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineers date - SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TQTHE FOLLOWING ADDRESS K8OORESVILLEREGIONAL OFFICE 918N.MAIN STREET A8ODRESV|LLENC 28115 ATTN:OEEBFKOVVOER The Permbtowisresponsible for tracking all partial certifications upuntil a final certification isreceived, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate z 1b. rz 0 0 CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS USE THE TAB KEY TO MOVE FROM FIELD TO FIELD? 1. Owner: la. Full Legal Name r.l..� PAGE 3 Application Number: (to be completed by DWQ) �24 27. ny, municipality, i-i A utility, etc.) acaste M4Ai~,i Ate, Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing offici The legal entity who will own this system is: 0 Individual ❑ Federal Municipality ❑ Stet County ❑ Private Partnership 0 Corporation ❑ Other (specify): ld. a I Street Address C, 1g State 1h. 4 - 4.44- tici 1 1i. Telephone Facsimile 2. Project (Facility!) Information: 2a. .A5-r J, 1 L. Ai E. 4E.(?, "m 1 tc r 2b. Brief Project Name (permit will refer to this name) 3. Contact Person; Zip Code E-mail ounty Where Project is Located 3a. L\ i. Mh `{ LA RV., Cc :.2, t 04r c" rz, c, - 1' i?"Lt t. \ et .. Ls Name and Affiliation of Some ane Who Can Answer Questions About this Application 3b. ` 2 — 4 (.4- 4-% c Phone Number E-mail 1. Project is New ❑ Modification of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is F;t Public (skip to Item B(3)) ❑ Private (go to item 2(a)) 2a, If private, applicant will be: Retaining Ownership (i,e, store, church, single office, etc.) or ❑ Leasing units (lots, townhomes, etc. - skip to Item 8(3)) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) 2b. If sold, facilities owned by a (must choose one) ❑ Public Utility (Instruction III) ❑ Homeowner Assoc./Developer (Instruction IV) Owner of Wast Name of WWTF WWTF Permit No,. Z 5a. ` rt C.c.m, 5b, 5c. Na'r Owner of Downstream Sewer Receiving Sewer Size Permit Number of Downstream Sew er Treatment Facility (WWIiTF) Treating Wastewater From This Project 6. The origin of this wastewater is (check all that apply): Residential Subdivision ❑ Apartments/Condominiums El Mobile Home Park ❑ School ❑ Restaurant • Office Ej Car Wash Institution ❑ Hospital El Church ❑ Nursing Home ❑ Other (specify): 7. Volume of wastewater to be permitted in this project: gallons per day if known 44, DomesticlCommercial % industrial % Other (specify): 8. If the permitted flow is zero, indicate why: • Interceptor Line - Flow will be permitted is subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected PFICATION 0 VCK APPLICATION PUMP STATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below, Values other than that in 15A NCAC 2H .0219(IX1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(1X3). ° C.' b Rhok '3 4) 0 LI k> 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 0 0 ENTER TOTAL LINE LENGTH IN MILES 0 Length (feet) Gravity or Force Main (use the pull down menu) I 5 . IZ-Ag ti7 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3- plans for cross-reference) (MGD) GPM @ TDH portable generator w/telemetry; 4-wet well storage) t\,( 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force CO Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? Yes 0 No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13 Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certificaton D Yes D No N/A Sedimentation and Erosion Control Plan? 0 Yes 0 No P N/A 0 Yes 0 No N/A Stormwater9 PLICATIO 0 TATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS) to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, z 0 A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: I, SIGNING OFFICIAL NAME, attest that this application for PROJECT NAME has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215, 6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation. la. Signing Official Signatu e 2. Professional Engineer's Certification: 8/4.40) Date attest that this application for has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement,' representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation, 2a. 0 Professional Engineer Name 2b. (A 2�LL Engineering Firm 2c. 11...:$3 4-0 ti, _ Address 2d. 14 c. 2e. e 2f es; cl City State Zip 2g. SZ, --1.1Z - 2h. SIA PI 2_ 2i. Telephone Facsimile E-mail Seal, Signature & Date The Web's Topographic Map 0.3 0.6 ©.9 1.2 1.5 kA 8 0.2 OA ©.6 0.8 1 m i Map center is UTM 17 478185E 3950278N (WGS84/NAD83) Newton quadrangle Projection is UTM Zone 17 NAD83 Datum Page 1 of 1 http://www.topozonecom/print. asp? z= 17&n=3954278.00009489&e=478 1 85&s=54&size... 8/10/2004 Michael F. Easley„ Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, RE, Director Division of Water Quality August 25, 2004 Mr, Lloyd Beasley, City Manager City of Conover Post Office Box 549 Conover, North Carolina 28613 Subject: Additional Information Request Application No, WQOO24282 East Way Lane Sewer Extension Wastewater Collection System Extension Catawba County, North Carolina Dear Mr, Beasley: The Division of Water Quality's Mooresville Regional Office has conducted a preliminary review of the subject permit application package. Additional information is required before we may continue our review. Please address the following items no later than September 22, 2004. A flow acceptance letter was not provided by the owner of the downstream sewers and/or the owner of the receiving wastewater treatment facility as is required by Instruction V of the application, Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted and name and permit number of the receiving wastewater treatment facility. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the application date. Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific flow acceptance letter. Please be aware that you are responsible for meeting all requirements set forth in North Carolina rules and regulations. Any oversights that occurred in the review of the subject application package are still the responsibility of the applicant. In addition, any omissions made in responding to the above items may result in future requests for additional information, Please reference the subject application number when providing the requested information. Two copies of all revised and/or additional documentation should be submitted to my attention at the address below. Please note that failure to provide this additional information on or before the above requested date may result in your application being returned as incomplete. Mooresville Regional Office 919 North Main Street Mooresville, NC 28115 Phonir (7()4) 663-1699 Fax: (704) 663-6040 Internet: h2o,enr.state.nc.us Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50% Recycled/10% Post Consumer Paper NorthCarotina Naturally 1od Beasley Page August , 2004 f you should have any questions regarding the acceptance of your application, please do not ate to contact me t (704) 3- . Thank you for your cooperation. No enclosures So a Consultant cc. R.C. Williams, PE, 4 North Center Street, Hickory NC 60 FT Application File No enc our) Per it Number Pr Catepow Pon -discharge 0 24282 Permit Type Fast Track k Gravity Sewer Extension, Pump Stetirano, Pressure Sewer Extensions Primary Reviewer sonja.williarns Permitted Flow 0 Fdnii Facility Name East Way Lane Sewer ExtenExtension Location Address Owner Owner Name City of Conover Dates/Events Permit Tracking iip Status Proiect Tyrie In review New Project Version t Cont nor OngIssue App Received 08416/04 Repute Activities Subdivision Wastewater tewater co Ie tia Outtall NULL 25/04 Permit lossifieetien Individual t ion nor f e ion Mooresville Faculty etatee unty' awba n Owner Type Government r Municipal Owner Affiliation Lloyd Beasley, PO Box Conover Scheduled Initiated issuance Public Notice Issu+ NC '1 Effective Expitmti Requested/Received Events Addition information received AdditionaM information requested rady Name St ea Index Number 02 0 Current Class SutCdasirr Mr, or Mrs. R. C. NCDL 2011388 •1810 N. Center s 11v'h©rp, NC 28601 F' V to the Srat AUG A i} V-:3 1- .i t=v 4 0 x 55 �T C'F CATA 'A COU TY" 08/31/04 To Whom It May Concern: Newton, N 28658 • i82814 5-7400 Michael Fox with the City of Conover forwarded information to me today indicating that a sewer tap at 1024 Easrway Lane SW is 1"r° m one subdivided lot and wservice one domestic residence only. The addition of 360 gpd flow to the Clark Creek Facility 4vi11 not cause any. NPDES over allocations. If you have any questions please do not hesitate to contact me at 828 695.4346, Respectfully, Danny znan WWTP Superintendent