Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0023552_Regional Office Historical File Pre 2018
A Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, RE., Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality February 5, 2004 Mr, Andrew Weathersbee, Manager Mountain View Marketplace, LLC P.O. Box 6149 Charlotte, North Carolina 28207 Subject: Permit No. WQ0023552 Mountain View Marketplace, LLC Mountain View Marketplace Wastewater Collection System Extension Catawba County, North Carolina Dear Mr. Weathersbee, In accordance with your application received on February 2, 2004, we are forwarding herewith Permit No. WQ0023552, dated February 5, 2004, to Mountain View Marketplace, LLC for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition '3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Purnp Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittees responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 919 N. Main Street, Mooresville, NC 28115 Internet ilttp://h2oenr.state,nousi Telephone (704) 663-1699 Fax (704) 663-6040 DENR Customer Service Center Telephone 1 877 623-6748 Mr. Andrew Weathersbee Page 2 February 5, 2004 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Mountain View Marketplace, LLC for the construction and operation of approximately 475 linear feet of 8-inch gravity sewer; a 78-gallon per minute pump station with duplex pumps, on -site audible and visual high water alarms, and a on -site generator with automatic transfer switch; as well as approximately 880 linear feet of 2-inch force main to serve a shopping center and a four -bedroom residence as part of the Mountain View Marketplace project, and the discharge of 14,680 gallons per day of collected domestic wastewater into the City of Hickory's Henry Fork WWTP (NPDES No. NC0040797) existing sewerage system, pursuant to the application received February 2, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall become voidable unless the agreement between Mountain View Marketplace, LLC arid the City of Hickory for collection and final treatment of wastewater is in full force and effect. The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and shall be a condition of this permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by North Carolina General Statutes 143-215.6A to 143-215.6C for violation of or failure to act in accordance with the terms and conditions of this pemnit. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Williams at (704) 663-1699. Sincerely, for Alan V1(< Klimek, P.E. cc: Catawba County Health Department Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0040797) Arthur Forman, Lucas -Forman, Inc. Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H ,0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B ;0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300, Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 5'h day of February, 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0023552 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, -1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215,6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 2 Fast Track Engineering Certification Permit No. WQ0023552 February 5, 2004 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineers Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (E] periodically, E] weekly, El full time) the construction of the Mountain View Marketplace, Catawba County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28116 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. iE OE NORTH CAROLINA COUNTY OF CATAWBA Permit No. DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (di) and entered into this 30,th day of January 2004, by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and Mountain View Marketplace, LLC, a limited liabili ornpatty licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: The DEVELOPER is the owner of the certain land lying in Catawba County, upon which it ereetig and will erect a commercial sho in center dwelling -units and other improvements, said development to be known as "Mountain View Market lace Shopping Center" (hereinafter the "Development") B. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter the "Disposal System") to provide sanitary sewage disposal to serve the Development on said lands. C. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143-215.1 to construct, maintain, and operate the Disposal System. D. E. The DEVELOPER he handling hand he property affairs and business of the Development F. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER, its successors and assign, do hereby mutually agree as follows: The DEVELOPER shall construct the Disposal System in accordance with the perrnit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The DEVELOPER shall not transfer ownership andfor control of the Disposal System heAssoit8isn until construction has been completed in accordance with the permit and approved plans, and the staffefthe Division of Water Quality has inspected and approved of the facilities. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. FORM: DEV 02/03 Page 1 of 2 The DEVELOPER confirms to the COMMISSION the Disposal System and appurtenances thereto afe-paft- properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The DEVELOPER certifies that i4en4ity the entire waswM4featme • Disposal System will receive the highest priority for expenditures of the Development by and local taxes and insurance. The DEVELOPER at its expense shall maintain Disposal System will -be -ma' hat he 7. if a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater unless such action requires DEVELOPER to bear the expense of purchasing easements and/or extending sewer lines over and across land not owned by the DEVELOPER.. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the "Aei4en DEVELOPER to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall pf iieBy3w444heAoeiation shall not enter into voluntary dissolution without first having transferred the Disposal System to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a permit. 9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) whcre tthe Develomet is located and in the offices of the Secretary of State of North Carolina IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: FOR THE ENVIRONMENTAL MANAGEMENT COMMISSION Alan W. Klimek,'P.E., Director d' Division of Water Quality Date: -61,TathaRY FORM: DEV 02/03 , 200 DEVELOPER: Mountain View Marketplace, LLC Andrew H. Weathersbee, manager Date: January30, 2004 Page 2 of 2 CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 0 2 0 z u_ z 0 0 0. 1- 2 0 LLz LU Application Number: (to be compieted by DWQ) , 21 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! \i'V(>2.0 i 1, Owner: la. Mountain View Marketplace, LLC Full Legal Name (company, municipality, HOA, utility, etc.) 1 b. Andrew H. Weathersbee, Manager Signing Official Name and Title (Please eview 15A NCAC 2H .0206(b) for authorized signing officials! The legal entity who will own this system is: Ej Individual 0 Federal 0 Municipality El State/County [J Private Partnership 0 Corporation X Other (specify): LLC 1 d. Post Office Box 6149 Street Address 1 f. NC State 1 h. (704) 372-0053 1 L (704) 372-0055 Telephone Facsimile 2, Project (Facility) information: 2a. Mountain View Marketplace Brief Project Name (permit will refer to this name 3. Contact Person: 3a, Arthur F. Forman, Civil Engineer 1 e Charlotte City 1g, 28207 Zip Code sweawgi@bellsouth.net E-mail 2b Catawba County Where Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 3b, (704) 527-6626 3c. affonnan@lucas-forman.com Phone Number E-mail 1. Project is X New Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is E Public (skip to item B(3)) X Private (go to Item 2(a)) 2a. If private, applicant will be; 2b. If sold, facilities owned by a (must choose one ',Retaining Ownership (i.e. store, church, single office, etc.) or 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) S Selling units (lots, townhomes, etc - go to Item B(2b)) 3. City of Hickory 0 Public Utility (Instruction lil) X Homeowner Assosc,/Developer (Instruction IV) Owner of Wastewater Treatment Facility (VVVVTF) Treating Wastewater From This Project 4a. Henry Fork 4b. NC.0040797 Name of VVWTF VVVVTF Permit No, 5a. City of Hickory 5b. 8" 5c, nla Owner of Downstream Sewer Receiving Sewer Size Permit Number of Downstream Sewer (if known) 6 The origin of this wastewater is (check all that apply): Residential Subdivision 0 Apartments/Condominiums 0 Mobile Home Park School 0 Restaurant 0 Office 0 Car Wash El Institution Li Hospital LJ Church 0 Nursing Home X Other (specify): Shopping Center 7. Volume of wastewater to be permitted in this project: 14L680 gallons per day 100 % Domestic/Commercial % Industrial % Other (specify): 8. If the permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line El Flow has already been allocated in Permit No. LJ Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 - Rev. 1 06/03 ACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H ,0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H ,0219(I)(1-2) must be approved prior to submittal of this application, Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unitr 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(1)(3). ; . 0 0 Grocery Store -Retail area 48,000 sf@l 20 gpc1/1000 sf=5,760 gpri, meat market/deli/bakery 8 emp.@25 gpallemp. and 2000 sf@ 50 gpd/100sf-71200 gpd, Restaurant -Bar 12 seats@20gpcliseat and Eating 100 seats@40 gpdlsea t=4,240 gpd, Free standing Drug Store 14,500 sf@120 gpd./1000sf=1,740 gpd, Retail Shops 12,000 sf@120 gpd11000st=1,440 gpd, One four -bedroom residence@120 gpd/bedroom-480 gpd ----------------- TOTAL Permitted Flow = 14,860 GPD P4 2 A v et (Fertv“.... t ,v2q d 10 Summary of Sewer Lines to be Pen Size (inches) 8" 2" ed (attach additional sheets if necessary) ENTER TOTAL LINE LENGTH IN MILES Length (feet) Gravity or Force Main (use the pull down menu) 475 ft Gravity 880 ft Force Main 0.257 mi ummary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (self chosen - as shown on plans for cross-reference) Design Flow (MGD) 0.372 MGD 37,150 GPD Power Reliability Option Operational Point (1- dual line feed; 2- permanent generator wIATS; 3- GPM TDH portable generator witelemetry; 4-wet well storage) 78 GPM © 82 TDH 2 — Permanent Generator 12, Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force CO Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? X Yes 0 No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? 0 Yes 0 No X N/A Sedimentation and Erosion Control Plan? Stormwater? X Yes IJNo 0 N/A XYes EJNo El NUA FT A 02 03 - Rev. 1. 06/03 z0 d z C:t 2a. Arthur F. Forman Professional Engineer Name 2b. Lucas -Forman, Inc. Engineering Firm 2c. P.O. Box 11386 Address 2d. Charlotte ACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: X A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, X A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1 Applicant's Certification: la. I, Andrew H. Weathersbee, manager attest that this application for Mountain View Marketplace, LLC has been reviewed by me and is accurate and complete to the best of my knowledge, understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note. In accordance with North Carolina General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 041 3 0 0 I - Signing Official Signature 2. Professional Engineer's Certification: Date 1 attest that this application for Mountain View Marketplace, LLC has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and ail other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design, Note: in accordance with NC General Statutes 143-215,5A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, 2e, NC 2f, 28220 City State Zip 4444N610,Holvoo 2g. (704) 527-6626 2h. (704) 527-9640 2i, afforman@lucas-forman.com Telephone Facsimile Seal, Signature & Date FTA 02/0 - Rev. 1 06/03 02104/04 Permit Number 0023552 Pe"rt Tracking IM Progratin Category Non -discharge Pe ItTst frank Gravity Sewer Extension, Punrip Stations, Pressure Sewer Extensions Primary Reviewer sonja.williams Permitted Flow 14680 Facility Facility Name Mountain View larket face Location Address Owne Status in review Protect Type New Project Version Permit Classifiestt n individual Permit Contact Affiliation Minor Region inor iooresiii County Catawba Facility Contact A tto tion Owner Name Mountain View larketpiace, LC Oat di vertu Orin 1$41.10 Apo Received 02/02/04 Regulated Activities Commercisi or industrial, abler Private residence, single family Restaurant Wastewater collection titan NULL Scheduled' ted Issuance Owner Type Mtn-Iovernrttent Owner Willett Andrew har41 Public Notice waterb dy Name Index Numb x 6149 erbee NC 28207 Requested/Received Events Additions! Information requested Additional information received Current Class Sub sin PERRIN PROPERTIES.L Fb 0 BOX 6149 CHARLOTTE, TTE NTH 28207 3AY 1'0 THE [ � t E ._. S'k'z��frwrt i FI �mi6�, �+i,t4,. a.w�yv h9aw�.4 �ru n:¢# 1'7i Y2i t3 Mini 1 View '0000 DATA : par r" C ..._2004 tate e&wLigfr Public Utilities January 29, 2004 ; * TO WHOM IT MAY CONCERN *r*:* 1421 ACM The City of Hickory does have adequate sewer capacity to serve the Min View Market Place, PIN 3701-09-054391 & 1029; 2791-12-95-8079 & 6185 & 6323; 370142-95-7395 & 8396. The average flow will he 14,860 GPO and will he going to out Henry Fork Plant, NFDES NC00=40797. Should additional information be needed, please advise Sincerely, Kevin B. Greer, PE Public Services Manager R.. ATER. PublMU TO 0 Y CONCERN The City of Hickory r does adequtoewer capacity to sere tt e tn,View Market Place, P1S # 1- - 5-1 1 & 1029; 791-1 -9 8079 & 6185 01- - - 5 The average flow will be 14,860 rP grid wii1 be going to out HenryPork Flank NPDES iv; Should additional n be needed, please advise, Sinner Kevin B, Greet, P Public Se ices Manager' Cap fight G) l9 7„ F inch, Inc. Copyright (C) 1997, Maptech, Inc. MiGK R 35"Q8l 1 httpil ww,scrctar).statc,I .us/cor r 6 NC Eame F. Marsha Secretary North Carolina DEPARTMENT OFTHE ECRETARY OF` STATE PO Brix 29622 Rita tgtro„ NC 27626-0622 (.919)807-2000 Date 2/4/2004 Click here to: View Document Filings Print a pre -populated Annual Report Fot Corporation Names File an Annual Report I Name Name Type Mountain View Marketplace, LLC Legal Cited Liability Company Information SOSID: Status: Date Formed: Citizenship: State of Inc: Registered Agent Agent Name: Registered Office Address: Registered Mailing Address: Principal Office Address: Principal Mailing Address:. 0692442 Current -Active 9/25/2003 Domestic NC Beddow, John Wm 600 South College Street Charlotte NC 28202 No Address No Address Fire° questions or comments about the / ort For questions or comments concerning the Corpurauor 2/4/2004 1:01 PM