Loading...
HomeMy WebLinkAboutWQ0028847_Application (FTSE)_20210426Permit Number WQ0028847 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWRule Permitted Flow 15,000 Facility Facility Name Parker Ventures Inc Public Sewer Location Address Owner Owner Name Cape Fear Public Utility Authority Central Files: APS _ SWP 4/8/2021 Permit Tracking Slip Status Project Type In review Major modification Version Permit Classification B Individual Permit Contact Affiliation Major/Minor Region Minor Wilmington County New Hanover Facility Contact Affiliation Owner Type Government - Municipal Owner Affiliation James R. Flechtner PE 235 Government Center or Dates/Events Wilmington NC 28403 Scheduled Orig Issue App Received Draft Initiated Issuance 6/3/2005 3/26/2021 Regulated Activities Domestic, other Restaurant DWR State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: VR_ _ (to be completed by DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: 1. Applicant's name: Cane Fear Public Utility Authority (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State(County ❑ Municipal ® Other 3. Signature authority's name: Frank Steers per 15A NCAC 02T .0106ib) Title: Deputy Executive Director 4. Applicant's mailing address: 235 Government Center Drive City: Wilmington State: NC Zip: 28403-_ 5. Applicant's contact information: Phone number: (910) 332-6670 Email Address: Frank.stvers@,cfpua.or¢ 11. PROJECT INFORMATION: I gilt 1. Project name: Castle Havne Sewer Expansion W%w q T 2. Application/Project status: JProposed (New Permit) / JSExisting Pennit/Pmjectt If a modification, provide the existing permit number: W000_ and issued date: b 1V —\,� If new construction but part of a master plan, provide the existing permit number: W000_ 3. County where project is located: New Hanover 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.351°Longitude: -77.9000 5. Parcel ID (if applicable): R01 t 00-014-005-000 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Leonard McBrvde License Number: 036163 Firm: WithersRavenel Mailing address: 219 Station Road, Suite 101 City: Wilmington State: NC Zip: 28405-_ Phone number: (919) 228-0424 Email Address: lmcbrvde(riwithersravenel.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: North Side Wastewater Treatment Facility Permit Number: #1NC0023965 Owner Name: Cam Fear Public Utility Authority V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ_ Downstream (Receiving) Sewer Size: 18 inch System Wide Collection System Permit Number(s) (if applicable: WQCS00012 Owner Name(s): Cape Fear Public Utility Authority FORM: FTA 04-16 Pagel of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's 0 crational Agreement (FORM: DEV 1 been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association has an Operational Agreement (FORK HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply) ® Residential Owned ® Retail (stores, centers, malls) ❑ Car Wash ® Residential Leased ® Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ® Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ® Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial _% Industrial (See 15A NCAC 02T .0103(20)) [ I•Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114 ( ? ❑ Yes ❑ No ➢ If yes. provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 021.0114(fl) Daily Design Flow No. of Units Flow gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total GPD a See 15A NCAC 02T .0114(b) (d) (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-41. b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T 01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 021 .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ® Flow has already been allocated in Permit Number: WO0028938 ® Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VH. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC 1GraviR Sewers1: I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 85 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable)—02T.0305 & NIDC 1Pumo Stations/Force Nfains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Parker 2. Approximate Coordinates (Decimal Degrees): Latitude: 34.351, Longitude:-77.900° 3. Design flow of the pump station: 0.144 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 100 gallons per minute at 157 feet total dynamic head (I'DH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 4 396 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)11): ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(hxl)(B)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(hx l)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(l XQ: ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(t)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305t R & lei ® Yes [:]No ➢ 15A NCAC 02T.0305( I) contains minimum senaratinnc that shall he nrn.dd..i rn. ­, ........,� Setback Parameter; S —aration Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 Feet "Any private or public water supply source, including any wells, W S-I waters of Class 1 or Class B impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or fide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building: foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305(el contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ "Stream classifications can be identified using the Division's NC Surface Water Classifications weboaee D If noncompliance with 02T.0305(11 or M. see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) []Yes ❑ No ®N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per I5A NCAC 02B .0200? ❑ Yes ❑ No ® N/A ➢ This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permilting Branch 5. Does project comply with 15A NCAC 02T.0105(cH61(additional permits/certifications)? ®Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 XL CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version). and the Gravity Sewer Minimum Design Criteria I latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Altemative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supoortiop documents 2. Professional Engineer's Certification: 1 — Leonard McBryde III, PE attest that this application for (Professional Engineer's name from Application Item BI.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: •.•• �{ C A !_ -_ a 3/24/2021 ••,0y% 114E •••qRD McOE;� 3. Applicant's Certification per 15A NCAC 02T .0106(b): L i N i- G . '5 T YE 25 D� PU Y EfEGvrtVE f7r2 a� that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be retuned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: t/ Date: 317-#01 FORM: FTA 04-16 Page 5 of 5 � V r��CtlP Navne�, h GRAPHIC SCALE 1 inch = 1000 ft. w F PROJECT LOCATION �, ��. •,\` J HOLLY SyrL r CE rpVE LN ASTS / Lollo � �, I I, •`, x Cis . 10, CASTLE HAYNE 1! WithersRavenel SEWER EXPANSION USGS TOPO MAP Engineers ee s i Ptannersi s nnyo rs CASTLE HAY AEW N"VER COUW WRTH CAROIPp GRAPHIC SCALE r i'� N 1� q •+ -1 inch = 500 ft WU, ynn.Me f aGa Pstl_?:gye _ lHolfyShefierand _ � s ��:�•pPary,Rd® - �olly 5t 1 i4,7 f n L ash#St j q._ ` s r�r *' s'Garden Place Dr R°iv,r>ari Dr o � 1 1 lor �� �,p� 0/1 c 10 WithersRavenel March 26, 2021 Department of Environmental Quality® !Y j Wilmington Regional Office— Water Quality Section NIAiQ 2 5 2021 127 Cardinal Drive Ext Wilmington, NC 28405 Attn: Dean Hunkele RE: Castle Hayne Sewer Expansion Dear Mr. Hunkele: Enclosed you will find the Fast Track Application for the Castle Hayne Sewer Expansion Project. There will be no flow requested with this application. The Castle Hayne Sewer Expansion Project consists of the installation of a new duplex submersible pump station approximately 150 feet north of the intersection of Castle Hayne Road and Prince George Avenue. In addition, the project includes approximately 85 LF of 8-inch gravity sewer pipe and approximately 396 LF of 4-inch force main. The force main will travel east, cross US 117 by bore and jack and then head south along US 117 to connect with existing force main at Ash Street. Included items: - One paper copy of signed and sealed FTA 04-16 Form - One paper copy of USGS Topographic and Aerial Site Map - $480 Application Fee Please contact me if you have any questions or need any additional information. Thank you, /1 Leonard McBryde III, PE Senior Project Manager WithersRavenel 919-238-0424 direct 984-365-0528 cell 219 Station Road, Suite 101 I Wilmington, NC 28405 t: 910.256.9277 1 f: 910.255.2534 1 wwnro.withersravene1.corn ! License No. C-0832 Asheville Cary I Greensboro Pittsboro 1 Raleigh I Wilmington